共查询到20条相似文献,搜索用时 15 毫秒
1.
A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H(-) ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H(-) ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA∕25 keV H(-) beam with an emittance of 0.3 π mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected. 相似文献
2.
Welton RF Dudnikov VG Gawne KR Han BX Murray SN Pennisi TR Roseberry RT Santana M Stockli MP Turvey MW 《The Review of scientific instruments》2012,83(2):02A725
The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent ~38 mA peak current in the linac and an availability of ~90%. H(-) beam pulses (~1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, ~60 kW) of a copper antenna that has been encased with a thickness of ~0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of ~99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of ~75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance∕installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to ~100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence. 相似文献
3.
The measurement method for some radioisotope such as 99Tc, 182Hf, 151Sm is developing in China Institute of Atomic Energy (CIAE) accelerator mass spectrometry (AMS) system, and applications in the fields of nuclear physics, geosciences, life science and materials science is carried out. The brief introduction of these methods and applications are described in this paper. 相似文献
4.
An Y Cho W Chung KJ Lee K Jang S Lee SG Hwang YS 《The Review of scientific instruments》2012,83(2):02A727
The effect of rf wave frequencies on the production of H(-) ion is investigated in a transformer coupled plasma H(-) ion source at Seoul National University. A Langmuir probe is installed to measure the plasma density and temperature, and these plasma parameters are correlated to the extracted H(-) beam currents at various frequencies. The Langmuir probe is also used to measure the density of H(-) ions at the ion source by generating photodetachment with an Nd:YAG laser. The extracted H(-) currents decrease to a minimum value until 13 MHz and then, increase as the driving frequency increases from 13 MHz while the relative H(-) population measured by photodetachment monotonically decreases as the driving rf frequency increases from 11 MHz to 15 MHz. A potential well formed at the extraction region at high frequencies of more than 13 MHz is considered responsible for the increased H(-) beam extraction even with a lower photodetachment signal. The variation in the driving rf frequency not only affects the density and temperature of the plasma but also modifies the plasma potential with the existence of a filtering magnetic field and consequently, influences the extracted H(-) current through the extraction as well as formation of H(-) ions. 相似文献
5.
Faircloth D Lawrie S Gabor C Letchford A Whitehead M Wood T Perkins M 《The Review of scientific instruments》2012,83(2):02A701
The aim of the front end test stand project is to demonstrate that chopped low energy H(-) beams of high quality can be produced. The beam line currently consists of the ion source, a 3 solenoid low energy beam transport and a suite of diagnostics. A brief status report of the radio frequency quadrupole is given. This paper details the work to optimize the ion source performance. A new high power pulsed discharge power supply with greater reliability has been developed to allow long term, stable operation at 50 Hz with a 60 A, 2.2 ms discharge pulse and up to 100 A at 1.2 ms. The existing extraction power supply has been modified to operate up to 22 kV. Results from optical spectroscopy measurements and their application to source optimization are summarized. Source emittances and beam currents of 60 mA are reported. 相似文献
6.
Cao Y Lu W Zhang WH Sha S Yang Y Ma BH Wang H Zhu YH Guo JW Fang X Lin SH Li XX Feng YC Li JY Zhao HY Ma HY Zhang XZ Guo XH Wu Q Sun LT Zhao HW Xie DZ 《The Review of scientific instruments》2012,83(2):02B726
Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper. 相似文献
7.
Lu W Xie DZ Zhang XZ Xiong B Ruan L Sha S Zhang WH Cao Y Lin SH Guo JW Fang X Guo XH Li XX Ma HY Yang Y Wu Q Zhao HY Ma BH Wang H Zhu YH Feng YC Li JY Li JQ Sun LT Zhao HW 《The Review of scientific instruments》2012,83(2):02A328
A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet. 相似文献
8.
A baseline H(-) ion source and low energy beam transport (LEBT) system have been identified for Project X. The filament-discharge H(-) ion source has been fabricated by D-Pace, Inc. and is now in operation at LBNL. The source is capable of delivering over 10 mA of H(-) beam in cw operation with normalized 4 rms emittances less than 0.7 π mm mrad. A two-solenoid magnetic lens LEBT system has been design. The design has been validated with simulations of beam transport for 5 mA 30 keV H(-) beams using various simulation codes. 相似文献
9.
The front end test stand is being constructed at the Rutherford Appleton Laboratory, with the aim of producing a 60 mA, 2 ms, 50 Hz, perfectly chopped H(-) ion beam. To meet the beam requirements, a more detailed understanding of the ion source plasma is required. To this end, an initial study is made of the optical spectrum of the plasma using a digital spectrometer. The atomic and molecular emission lines of hydrogen and caesium are clearly distinguished and a quantitative comparison is made when the ion source is run in different conditions. The electron temperature is 0.6 eV and measured line widths vary by up to 75%. 相似文献
10.
Sha S Zhao HW Guo XH Zhang ZL Fang X Guo JW Zhang WH Lu W Cao Y Ma HY Lin SH Li XX Ma BH Yang Y Wang H Wu Q Li JY Feng YC Zhao HY Zhu YH Sun LT Zhang XZ Chen XM Xie DZ 《The Review of scientific instruments》2012,83(2):02B303
A laser (Nd:YAG laser, 3 J, 1064 nm, 8-10 ns) ion source has been built and under development at IMP to provide pulsed high-charge-state heavy ion beams to a radio frequency quadrupole (RFQ) for upgrading the IMP accelerators with a new low-energy beam injector. The laser ion source currently operates in a direct plasma injection scheme to inject the high charge state ions produced from a solid target into the RFQ. The maximum power density on the target was about 8.4 × 10(12) W∕cm(2). The preliminary experimental results will be presented and discussed in this paper. 相似文献
11.
Kalvas T Welton RF Tarvainen O Han BX Stockli MP 《The Review of scientific instruments》2012,83(2):02A705
A three-dimensional ion optical code IBSimu, which is being developed at the University of Jyva?skyla?, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H(-) ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H(-) currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole. 相似文献
12.
Rodrigues G Baskaran R Kukrety S Mathur Y Kumar S Mandal A Kanjilal D Roy A 《The Review of scientific instruments》2012,83(3):033301
Plasma potentials for various heavy ions have been measured using the retarding field technique in the 18 GHz high temperature superconducting ECR ion source, PKDELIS [C. Bieth, S. Kantas, P. Sortais, D. Kanjilal, G. Rodrigues, S. Milward, S. Harrison, and R. McMahon, Nucl. Instrum. Methods B 235, 498 (2005); D. Kanjilal, G. Rodrigues, P. Kumar, A. Mandal, A. Roy, C. Bieth, S. Kantas, and P. Sortais, Rev. Sci. Instrum. 77, 03A317 (2006)]. The ion beam extracted from the source is decelerated close to the location of a mesh which is polarized to the source potential and beams having different plasma potentials are measured on a Faraday cup located downstream of the mesh. The influence of various source parameters, viz., RF power, gas pressure, magnetic field, negative dc bias, and gas mixing on the plasma potential is studied. The study helped to find an upper limit of the energy spread of the heavy ions, which can influence the design of the longitudinal optics of the high current injector being developed at the Inter University Accelerator Centre. It is observed that the plasma potentials are decreasing for increasing charge states and a mass effect is clearly observed for the ions with similar operating gas pressures. In the case of gas mixing, it is observed that the plasma potential minimizes at an optimum value of the gas pressure of the mixing gas and the mean charge state maximizes at this value. Details of the measurements carried out as a function of various source parameters and its impact on the longitudinal optics are presented. 相似文献
13.
14.
Spädtke P Lang R Mäder J Maimone F Rossbach J Tinschert K 《The Review of scientific instruments》2012,83(2):02B720
Using improved beam diagnostic tools, the structure of an ion beam extracted from an electron cyclotron resonance ion source (ECRIS) becomes visible. Especially viewing targets to display the beam profile and pepper pot devices for emittance measurements turned out to be very useful. On the contrary, diagnostic tools integrating over one space coordinate like wire harps for profile measurements or slit-slit devices, respectively slit-grid devices to measure the emittance might be applicable for beam transport investigations in a quadrupole channel, but are not very meaningful for investigations regarding the given ECRIS symmetry. Here we try to reproduce the experimentally found structure on the ion beam by simulation. For the simulation, a certain model has to be used to reproduce the experimental results. The model is also described in this paper. 相似文献
15.
本文综合介绍国外硬质膜离子镀技术的近况,分別就硬质膜的应用、新型镀膜材料的性能及其应用等方面作了说明。 相似文献
16.
Fedosseev VN Berg LE Fedorov DV Fink D Launila OJ Losito R Marsh BA Rossel RE Rothe S Seliverstov MD Sjödin AM Wendt KD 《The Review of scientific instruments》2012,83(2):02A903
The resonance ionization laser ion source (RILIS) produces beams for the majority of experiments at the ISOLDE on-line isotope separator. A substantial improvement in RILIS performance has been achieved through a series of upgrade steps: replacement of the copper vapor lasers by a Nd:YAG laser; replacement of the old homemade dye lasers by new commercial dye lasers; installation of a complementary Ti:Sapphire laser system. The combined dye and Ti:Sapphire laser system with harmonics is capable of generating beams at any wavelength in the range of 210-950 nm. In total, isotopes of 31 different elements have been selectively laser-ionized and separated at ISOLDE, including recently developed beams of samarium, praseodymium, polonium, and astatine. 相似文献
17.
Kraus W Fantz U Franzen P Fröschle M Heinemann B Riedl R Wünderlich D 《The Review of scientific instruments》2012,83(2):02B104
Large and powerful negative hydrogen ion sources are required for the neutral beam injection (NBI) systems of future fusion devices. Simplicity and maintenance-free operation favors RF sources, which are developed intensively at the Max-Planck-Institut fu?r Plasmaphysik (IPP) since many years. The negative hydrogen ions are generated by caesium-enhanced surface conversion of atoms and positive ions on the plasma grid surface. With a small scale prototype the required high ion current density and the low fraction of co-extracted electrons at low pressure as well as stable pulses up to 1 h could be demonstrated. The modular design allows extension to large source dimensions. This has led to the decision to choose RF sources for the NBI of the international fusion reactor, ITER. As an intermediate step towards the full size ITER source at IPP, the development will be continued with a half-size source on the new ELISE testbed. This will enable to gain experience for the first time with negative hydrogen ion beams from RF sources of these dimensions. 相似文献
18.
Panitzsch L Peleikis T Stalder M Wimmer-Schweingruber RF 《The Review of scientific instruments》2011,82(9):093302
In this paper we present our measurements of charge-state and current-density distributions performed in very close vicinity (15 mm) of the extraction of our hexapole geometry electron cyclotron resonance ion source. We achieved a relatively high spatial resolution reducing the aperture of our 3D-movable extraction (puller) electrode to a diameter of only 0.5 mm. Thus, we are able to limit the source of the extracted ion beam to a very small region of the plasma electrode's hole (? = 4 mm) and therefore to a very small region of the neutral plasma sheath. The information about the charge-state distribution and the current density in the plane of the plasma electrode at each particular position is conserved in the ion beam. We determined the total current density distribution at a fixed coaxial distance of only 15 mm to the plasma electrode by remotely moving the small-aperture puller electrode which contained a dedicated Faraday cup (FC) across the aperture of the plasma electrode. In a second measurement we removed the FC and recorded m/q-spectra for the different positions using a sector magnet. From our results we can deduce that different ion charge-states can be grouped into bloated triangles of different sizes and same orientation at the extraction with the current density peaking at centre. This confirms observations from other groups based on simulations and emittance measurements. We present our measurements in detail and discuss possible systematic errors. 相似文献
19.