首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
科学级CCD相机在星敏感器中的设计与应用   总被引:4,自引:3,他引:1  
星敏感器通过探测天球上不同位置的恒星来确定航天器的姿态。星相机是星敏感器的成像系统。虽然近年来CMOS成像技术快速发展,但在科学级成像领域,特别是星敏感器应用中,CCD技术较成熟。本文的研究目的是研究一种探测能力强、数据更新快的用于星敏感器的成像系统。文中主要研究了基于TH7888A科学级CCD传感器的星相机的设计和应用,说明了CCD工作原理,详细分析了该种CCD传感器的星等探测灵敏度,论述了CCD星相机的设计方案。并用成像实验、动态范围测试、星等探测能力实验等实验验证了所设计的相机的性能。设计的星相机可以用给定的小型光学系统在60 ms以内的积分时间探测6等星,相机可达到10帧/秒的图像数据更新频率,满足短积分时间进行快速星光成像的要求。  相似文献   

2.
The absorption and transport scattering coefficients of biological tissues determine the radial dependence of the diffuse reflectance that is due to a point source. A system is described for making remote measurements of spatially resolved absolute diffuse reflectance and hence noninvasive, noncontact estimates of the tissue optical properties. The system incorporated a laser source and a CCD camera. Deflection of the incident beam into the camera allowed characterization of the source for absolute reflectance measurements. It is shown that an often used solution of the diffusion equation cannot be applied for these measurements. Instead, a neural network, trained on the results of Monte Carlo simulations, was used to estimate the absorption and scattering coefficients from the reflectance data. Tests on tissue-simulating phantoms with transport scattering coefficients between 0.5 and 2.0 mm(-1) and absorption coefficients between 0.002 and 0.1 mm(-1) showed the rms errors of this technique to be 2.6% for the transport scattering coefficient and 14% for the absorption coefficients. The optical properties of bovine muscle, adipose, and liver tissue, as well as chicken muscle (breast), were also measured ex vivo at 633 and 751 nm. For muscle tissue it was found that the Monte Carlo simulation did not agree with experimental measurements of reflectance at distances less than 2 mm from the incident beam.  相似文献   

3.
Zhou ZF  Cheng YH 《Applied optics》2008,47(19):3463-3466
A visual test method for detecting microdefects under fine surfaces is described. A new MO microscope that has a laser source, a CCD camera, and an exciting coil is developed for this work. A pulse generator supplies an intermittent square pulse to the exciting coil, which can intensify eddy currents yet reduce the working temperature of the exciting coil and sample. The magnetic field variation produced by the imbedded defect causes a rotation of the polarization plane of the reflected beam. Therefore the reflected beam carries an image of the defect, which is received by a CCD camera. The optical arrangement guarantees that no light is reflected back to the laser. The system was tested with a calibrator, which has an artificial subsurface defect; such a test attains a visual detected image. To our knowledge this is the first time an image of a subsurface defect has been distinctly detected with a MO sensor system.  相似文献   

4.
设计了一种新型带有自标定的数字准直瞄准测量系统。系统采用测微准直望远镜与CCD视觉系统相结合的方式,将测微准直望远镜的目视测量视场转换成数字测量视场,进而实现在整个数字视场范围内取样测量。通过对CCD相机的角度当量和位移当量进行标定,可直接计算出线位移和角位移,实现了数字化测量。通过实验验证,该系统的定位测量不确定度优于激光跟踪仪,定向测量不确定度优于经纬仪,可用于工业大尺寸测量。  相似文献   

5.
6.
Nemoto K  Nayuki T  Fujii T  Goto N  Kanai YK 《Applied optics》1997,36(30):7689-7695
A new deformable mirror control system is developed. This system consists of a deformable mirror, a CCD camera, an image processor, a computer, and actuator drive power supplies. A genetic algorithm is adopted as a control algorithm to obtain an optimum surface profile of the deformable mirror. A circular cross-sectional Gaussian beam was transformed into a beam with a rectangular contour using this system. Although the transfer function of this system is complicated and unknown, this system can be used to obtain the optimum beam profile within the achievable limits of a deformable mirror.  相似文献   

7.
基于FPGA的卫星图像模拟源系统设计   总被引:2,自引:0,他引:2  
作为星上的有效载荷, 星载图像压缩设备必须经过严格的测试后方能投入使用. 如果在每一次的测试过程中, 压缩设备均与其前端体积庞大的 CCD 相机系统对接, 势必会造成时间和物力的浪费. 为了保证星载图像压缩设备研发和测试的顺利进行, 本文设计了一套卫星图像模拟源系统, 以模拟多路 CCD 相机数据. 系统基于 FPGA 和 LAN91C111 搭建, 可以在联网和自动两种工作模式下工作. 为了满足 17 路图像数据同时发送的要求, 采用了 MicroBlaze 和 VHDL 联合编程实现 SDRAM 的高速读写控制. 测试表明, 该图像模拟源能满足各项设计指标.  相似文献   

8.
光斑质心亚像素定位误差的实验研究   总被引:3,自引:0,他引:3  
根据误差的来源将光斑质心亚像素定位误差归类为随机误差和系统误差,提出一种简单有效的实验方法对光斑质心定位误差进行定量测试.利用高精度一维电动平移台、POINT GREY Flea2-14S3 CCD相机和LED光源构建了测试系统,对测试结果进行研究和讨论,发现了测试系统LED光斑质心定位系统误差的周期性变化规律,计算得到了基于Flea2-14S3 CCD相机的光斑质心定位随机误差为0.018 pixels,系统误差为0.06 pixels,总体误差为0.063 pixels(约1/15 pixels),能够应用于以光斑质心检测为手段的测量系统中.实验表明,该测试系统可以作为估算光斑质心定位误差大小的一种有效的手段.  相似文献   

9.
研究开发了一种具有4个发射光源和1个CCD摄像机作为接收装置的光学非接触测头.测头可以用来测量包括具有强反射表面的曲面.测头基于三角法工作原理.在恰当设计的情况下,至多只有1路从工件表面反射回来的光,能够进入CCD摄像机.通过将相应通道切断,很容易消除镜面反射光的影响.这时测头就相当于1个三发射单接收光学非接触测头.测头可以同时用来测量表面的位置和方向.对于具有很大倾斜的表面具测头仍能正常工作,采用干涉滤光片消除了环境光的影响.提出了一种系统的标定方法.通过对量块的测量证实了系统工作的正确性和有效性并给出了实验结果.  相似文献   

10.
An endoscope electronic-speckle-pattern interferometer (ESPI) camera system is presented that can be applied to examinations of technical objects as well as for in vitro and in vivo minimal invasive medical diagnostics. Integration of optical fibers for the guidance of a cw-laser beam and an endoscopic imaging system yield a compact ESPI system that opens up new possibilities for highly sensitive interferometric intracavity inspection under handheld conditions. A CCD camera in combination with a fast frame-grabber system allows dynamic image subtractions at a frequency rate of as much as 25 Hz with high fringe contrast. Results from investigations of technical objects and biological objects in vitro and in vivo are obtained. In endoscopic minimal invasive therapy this method could substitute for the missing operator's tactile contact with the treated tissue by replacing it with visual information (endoscopic taction).  相似文献   

11.
A photopolymer holographic grating is used to produce the two sheared images in an electronic speckle pattern shearing interferometer. A ground glass screen following the grating eliminates unwanted diffraction orders and removes the requirement for the CCD camera to resolve the diffraction grating's pitch. The sheared images on the ground glass are further imaged onto the CCD camera. The fringe pattern contrast was estimated to be above 90%. A validation of the system was done by comparing the theoretical phase difference distribution with the experimental data from the three-point bending test.  相似文献   

12.
A micron-precision optical alignment system (OASys) for the PHENIX muon tracking chambers is developed. To ensure the required mass resolution of vector meson detection, the relative alignment between three tracking station chambers must be monitored with a precision of 25 μm. The OASys is a straightness monitoring system comprised of a light source, lens and CCD camera, used for determining the initial placement as well as for monitoring the time dependent movement of the chambers on a micron scale.  相似文献   

13.
A novel measuring system based on a single CCD camera and two laser projectors to record images and perform three-dimensional measurement of a distant object is proposed here. Because of the alignment of the laser beams which form in parallel with the optical axis of the CCD camera, projected spots will appear on the same scan line in a CCD image. As a result processing of a single scan line rather than the whole image is only required to identify the projected spots in the CCD image. Complex computation of video signals of the whole image via either pattern recognition or image analysis methods is therefore circumvented. On the basic of an established relationship between the distance and pixel counts between the projected spots in the CCD image, the proposed system not only measures the distance from a distant object but also the length of two arbitrarily designated points on the object. To provide better accuracy, intrinsic parameters of the CCD camera are taken into consideration in the measurement. Furthermore, the effect of laser diffusion is also proved to be irrelevant to the measuring accuracy here. Experimental results have demonstrated that the proposed measuring method is capable of yielding accurate results of three-dimensional measurement for a distant object in a very responsive way.  相似文献   

14.
基准尺作为摄影测量长度基准,其精度直接影响测量结果的准确性,为了保证基准尺长度的测量精度,设计了由气体静压导轨、激光干涉仪、CCD成像系统组成的测量系统。分析了影响测量精度的因素,并对组成基准尺的标志圆成像位置、CCD相机光轴、激光干涉仪、基准尺和CCD成像系统绕自身光轴旋转的调节误差进行了计算分析,用于指导CCD成像系统、激光干涉仪和基准尺的调节。最后应用该系统对基准尺进行多次测量,结果表明基准尺长度测量的标准差可达到1 μm,满足工业摄影测量的要求。  相似文献   

15.
A method for producing stabilized interference patterns for ultraviolet interference lithography using a CCD camera as the detector element is described. Intensity data obtained from the CCD element are filtered in software to minimize speckle and detector noise effects as well as to determine the relative phase of the interfering beams. A control signal is then issued to correct the fringe drift. The system allows rapid reconfiguration of the lithography setup with minimum realignment of optical components.  相似文献   

16.
Ye C  Sundström MO  Remes K 《Applied optics》1994,33(28):6626-6637
A new technique based on transmission intensity-quotient ellipsometry has been developed for determining the fibril angle and the relative phase retardation of single, intact pulp fibers. The method uses a polarizing microscope in conjunction with a microscope video camera or CCD camera. Requiring no sample pretreatment, the new method is simple, fast, more accurate than existing methods, and nondestructive of the fiber material. To test the new method, we employed the multiwavelength measurement principle. It is based on the fact that the fibril angle is independent of wavelength, while the relative retardation is inversely proportional to the wavelength used. Measurements were carried out with single pulp fibers as samples under the illumination of different light wavelengths. The measurements and some results are described and presented.  相似文献   

17.
CCD相机的亮度和色度测试仪器凭借其一系列的测量优势已广泛应用于平板显示器的测量领域。本文在综合国内外相关计量标准技术优势的基础上,根据平板显示行业所特有的溯源需求进行校准装置的研制,基于积分球匀光和光谱测色原理,研制出CCD相机的亮度色度校准装置,并对校准装置的计量性能和特性进行研究以及对装置的测量结果进行验证。结果表明,该校准装置满足作为计量标准的技术要求,可用于CCD相机亮度和色度参数的校准。  相似文献   

18.
线列 CCD 像机交汇测量精度分析   总被引:2,自引:0,他引:2  
目的 探讨提高线列 CCD像机交汇测量精度 ,在此基础上分析了 CCD像机交汇测量的原理 .方法 采用空间虚拟的光电靶代替实物靶来实现对弹丸目标脱靶量的实时获取 .结果与结论 在分析了 CCD像机测角精度与布站方式等影响交汇测量精度的因素后 ,对光电靶面上不同位置点的 CCD像机交汇坐标测量结果进行了计算 ,最终给出了测量精度与布站的关系 .CCD像机视轴正交时系统具有最高的测量精度 .  相似文献   

19.
频率调制多普勒全场测速技术是一种基于分子滤波和多普勒频移现象的流场速度测量方法,在高速、超高速及大尺度风洞流场测量方面潜力巨大.我们设计开发了采用CCD相机作为接收探头的FM-DGV实验系统,该系统主要包括激光器、片光光学系统、碘分子滤波器、图像采集相机、频率监测单元等.基于该系统进行了谐波幅值比和转盘线速度测试实验.实验结果表明,该实验系统工作正常,速度测量误差最大值小于2m/s.  相似文献   

20.
高速高灵敏光纤传输EMCCD相机设计   总被引:6,自引:3,他引:3  
针对高帧频摄像机灵敏度较低与无法远程实时传输的难题,本文采用EMCCD器件提高其灵敏度,并利用光纤通信与USB技术实现高帧频图像的远程实时传输与记录.文章详细介绍了基于EMCCD器件CCD60建立相机的一种方法.利用CPLD器件产生EMCCD控制时序及视频同步处理控制时序,采用集成器件与分立器件相结合的方式建立EMCCD垂直驱动电路,建立EMCCD工作环境;然后,采用具有CDS功能的集成器件对CCD视频信号进行数字化,获得高帧频数字图像数据;再使用CPLD器件与光传输编解码芯片结合的方式实现高速图像数据的远程实时传输,最后采用USB2.0技术实现高速数据的实时采集.系统像素分辨率128×128,最高帧频可达1 000 fps,能应用于低照度高速图像荻取场合.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号