首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.  相似文献   

2.
BACKGROUND: Experimental studies suggest that the antiproliferative effect of heparin after arterial injury is maximized by pretreatment. No previous studies of restenosis have used a pretreatment strategy. We designed this study to determine whether treatment with nadroparin, a low-molecular-weight heparin, started 3 days before the procedure and continued for 3 months, affected angiographic restenosis or clinical outcome after coronary angioplasty. METHODS AND RESULTS: In a prospective multicenter, double-blind, randomized trial, elective coronary angioplasty was performed on 354 patients who were treated with daily subcutaneous nadroparin (0.6 mL of 10,250 anti-Xa IU/mL) or placebo injections started 3 days before angioplasty and continued for 3 months. Angiography was performed just before and immediately after angioplasty and at follow-up. The primary study end point was angiographic restenosis, assessed by quantitative coronary angiography 3 months after balloon angioplasty. Clinical follow-up was continued up to 6 months. Clinical and procedural variables and the occurrence of periprocedural complications did not differ between groups. At angiographic follow-up, the mean minimal lumen diameter and the mean residual stenosis in the nadroparin group (1.37+/-0.66 mm, 51.9+/-21.0%) did not differ from the corresponding values in the control group (1.48+/-0.59 mm, 48.8+/-18.9%). Combined major cardiac-related clinical events (death, myocardial infarction, target lesion revascularization) did not differ between groups (30.3% versus 29.6%). CONCLUSIONS: Pretreatment with the low-molecular-weight heparin nadroparin continued for 3 months after balloon angioplasty had no beneficial effect on angiographic restenosis or on adverse clinical outcomes.  相似文献   

3.
OBJECTIVES: We assessed the safety and efficacy of stent placement in patients with poorly controlled hypertension and renal artery stenoses, which are difficult to treat with balloon angioplasty alone. BACKGROUND: Preliminary experience with stent placement suggests improved results over balloon angioplasty alone in patients with atherosclerotic renal artery stenosis. METHODS: Balloon-expandable stents were placed in 100 consecutive patients (133 renal arteries) with hypertension and renal artery stenosis. Sixty-seven of the patients had unilateral renal artery stenosis treated and 33 had bilateral renal artery stenoses treated with stents placed in both renal arteries. RESULTS: Angiographic success, as determined by quantitative angiography, was obtained in 132 (99%) of 133 lesions. Early clinical success was achieved in 76% of the patients. Six months after stent placement, the systolic blood pressure was reduced from 173 +/- 25 to 147 +/- 23 mm Hg (p < 0.001); the diastolic pressure from 88 +/- 17 to 76 +/- 12 mm Hg (p < 0.001); and the mean number of antihypertensive medications per patient from 2.6 +/- 1 to 2.0 +/- 0.9 (p < 0.001). Angiographic follow-up at a mean of 8.7 +/- 5.0 months in 67 patients revealed restenosis (>50% diameter narrowing) in 15 (19%) of 80 stented vessels. CONCLUSIONS: Renal artery stenting is an effective treatment for renovascular hypertension, with a low angiographic restenosis rate. Stent placement appears to be a very attractive therapy in patients with lesions difficult to treat with balloon angioplasty such as renal aorto-ostial lesions and restenotic lesions, as well as after a suboptimal balloon angioplasty result.  相似文献   

4.
OBJECTIVES: The Probucol Angioplasty Restenosis Trial was a prospective, randomized, controlled study that investigated the effectiveness of probucol therapy in reducing the rate of restenosis after percutaneous transluminal coronary angioplasty (PTCA). BACKGROUND: Antioxidants have an inhibitory effect on smooth muscle cell growth in experiments in vitro and in vivo, which suggests a possible pharmacologic effect on restenosis after PTCA. METHODS: One hundred one patients were randomly assigned to receive 1,000 mg/day of probucol or control (no lipid-lowering) therapy 4 weeks before PTCA. After 4 weeks of premedication, both groups underwent PTCA. Probucol was continued until follow-up angiography 24 weeks after PTCA. Angiographic results were analyzed at a core laboratory by quantitative coronary angiography. RESULTS: Dilation was successful in 46 of 50 patients in the probucol group and 45 of 51 in the control group. At follow-up angiography 24 weeks after angioplasty, angiographic restenosis occurred in 9 (23%) of 40 patients in the probucol group and 22 (58%) of 38 in the control group (p = 0.001). Minimal lumen diameter was 1.49 +/- 0.75 mm (mean +/- SD) in the probucol group and 1.13 +/- 0.65 mm in the control group (p = 0.02). Percent diameter stenosis at follow-up angiography in the probucol group was significantly lower than that in the control group (43.9% vs. 56.4%, p = 0.009). The late loss was 0.37 +/- 0.69 mm in the probucol group and 0.60 +/- 0.62 mm in the control group (p = 0.13). The loss/gain ratio was 0.32 +/- 0.74 in the probucol group and 0.56 +/- 0.81 in the control group (p = 0.059). Net gain was greater in the probucol group than in the control group (0.77 +/- 0.70 vs. 0.48 +/- 0.59 mm, p = 0.053). CONCLUSIONS: Probucol administered beginning 4 weeks before PTCA appears to reduce restenosis rates.  相似文献   

5.
OBJECTIVES: This study was designed to examine whether oversized implantation of the new, less shortening Wallstent provides a more favorable long-term clinical and angiographic outcome in chronic total occlusions than does conventional coronary balloon angioplasty. BACKGROUND: Restenosis and reocclusion remain major limitations of balloon angioplasty for chronic total occlusions. Enforced mechanical remodeling by implantation of the oversized Wallstent may prevent elastic recoil and improve accommodation of intimal hyperplasia. METHODS: Lumen dimension was measured by a computer-based quantitative coronary angiography system (CAAS II). These measurements (before and after intervention and at 6-month follow-up) were compared between the groups with Wallstent implantation (20 lesions, 20 patients) and conventional balloon angioplasty (266 lesions, 249 patients) for treatment of chronic total occlusion. Acute gain (minimal lumen diameter after intervention minus that before intervention), late loss (minimal lumen diameter after intervention minus that at follow-up) and net gain (acute gain minus late loss) were examined. RESULTS: Wallstent deployment was successful in all patients. High pressure intra-Wallstent balloon inflation (mean +/- SD 14 +/- 3 atm) was performed in all lesions. Although vessel size did not differ between the Wallstent and balloon angioplasty groups, acute gain was significantly greater in the Wallstent group (2.96 +/- 0.55 vs. 1.61 +/- 0.34 mm, p < 0.0001). Although late loss was also significantly larger in the Wallstent group (0.81 +/- 0.95 vs. 0.43 +/- 0.68 mm, p < 0.05), net gain was still significantly greater in this group (2.27 +/- 1.00 vs. 1.18 +/- 0.69 mm, p < 0.0001). Angiographic restenosis (> or = 50% diameter stenosis) occurred at 6 months in 29% of lesions in the Wallstent group and in 45% of those in the balloon angioplasty group (p = 0.5150). CONCLUSIONS: Implantation of the oversized Wallstent, with full coverage of the lesion length, ensures resetting of the vessel size to its original caliber before disease and allows greater accommodation of intimal hyperplasia and chronic vessel recoil. Wallstent implantation provides a more favorable short- and long-term clinical and angiographic outcome than does conventional balloon angioplasty for chronic total occlusions.  相似文献   

6.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

7.
BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.  相似文献   

8.
OBJECTIVES: This study sought to evaluate preintervention and postintervention intravascular ultrasound studies for potential predictors of angiographic restenosis and to use ultrasound predictors of restenosis to enhance our understanding of the pathophysiology of the restenosis disease process. BACKGROUND: Restenosis remains the major limitation of percutaneous transcatheter coronary revascularization. Although its mechanisms remain incompletely understood, numerous studies have identified some of the clinical, anatomic and procedural risk factors for restenosis. Intravascular ultrasound imaging of target lesions before and after catheter-based treatment consistently demonstrates more target lesion calcium, more extensive reference segment atherosclerosis, smaller final lumen dimensions, significant residual plaque burden and a greater degree of tissue trauma than is evident by angiography. METHODS: Intravascular ultrasound studies were performed in 360 nonstented native coronary artery lesions (final diameter stenosis 18 +/- 11%) in 351 patients for whom follow-up angiographic data were available 6.4 +/- 3.6 months later. Hospital charts were reviewed, and qualitative and quantitative coronary angiographic and intravascular ultrasound analyses were performed by independent core laboratories. Four dependent angiographic end points were tested: restenosis as a binary definition (> or = 50% diameter stenosis at follow-up) was the primary end point; follow-up diameter stenosis, late lumen loss and follow-up minimal lumen diameter were the secondary end points. RESULTS: Reference vessel size, the preintervention quantitative coronary angiographic assessment of lesion severity and the postintervention intravascular ultrasound cross-sectional measurements predicted the late angiographic results. In particular, the intravascular ultrasound postintervention cross-sectional narrowing (plaque plus media cross-sectional area divided by external elastic membrane cross-sectional area) predicted the primary end point (restenosis) and two of the three secondary end points (follow-up diameter stenosis and late lumen loss) and was therefore the most consistent predictor of restenosis. CONCLUSIONS: Intravascular ultrasound variables are more powerful and consistent predictors of angiographic restenosis than currently accepted clinical or angiographic risk factors.  相似文献   

9.
Restenosis remains a major limitation of coronary angioplasty in spite of major advances in techniques and technology. Recent studies have demonstrated that ionizing radiation may limit the degree of this problem. Gamma radiation has been shown to be effective in reducing in stent restenosis in humans, and beta radiation following encouraging results in animals has been shown to be feasible in humans. The objective of this study was to assess the feasibility of a 5 F non-centered catheter to deliver beta radiation emitting seeds to the lesion site post angioplasty and its effect on restenosis. Following successful angioplasty, patients were randomized to treatment with 12, 14 or 16 Gy at the angioplasty site. This was delivered with a 5 F non-centered catheter. Twelve beta radiation emitting seeds (90Sr/Y) were delivered to an area 3 cm in length to cover the angioplasty site. Angiographic follow-up was performed at 6 months. Baseline and follow-up angiograms were performed by blinded investigators at a core laboratory. This interim report comprises the first 35 patients to complete 6-month angiographic follow-up. There were no major radiation incidents. Four patients had evidence of angiographic restenosis. The MLD (mm) and percent stenosis were 0.77 +/- 0.27/72.5 +/- 8.6 pre angioplasty, 2.08 +/- 0.4/25.7 +/- 9.8 post angioplasty and radiation and 2.05 +/- 0.59/25.7 +/- 19.8 at follow-up respectively. CONCLUSION: Beta radiation can be feasibly and safely delivered post coronary angioplasty with a very encouraging reduction of restenosis.  相似文献   

10.
OBJECTIVE: This study sought to compare two strategies of revascularization in patients obtaining a good immediate angiographic result after percutaneous transluminal coronary angioplasty (PTCA): elective stenting versus optimal PTCA. A good immediate angiographic result with provisional stenting was considered to occur only if early loss in minimal luminal diameter (MLD) was documented at 30 min post-PTCA angiography. BACKGROUND: Coronary stenting reduces restenosis in lesions exhibiting early deterioration (>0.3 mm) in MLD within the first 24 hours (early loss) after successful PTCA. Lesions with no early loss after PTCA have a low restenosis rate. METHODS: To compare angiographic restenosis and target vessel revascularization (TVR) of lesions treated with coronary stenting versus those treated with optimal PTCA, 116 patients were randomized to stent (n=57) or to optimal PTCA (n=59). After randomization in the PTCA group, 13.5% of the patients crossed over to stent due to early loss (provisional stenting). RESULTS: Baseline demographic and angiographic characteristics were similar in both groups of patients. At 7.6 months, 96.6% of the entire population had a follow-up angiographic study: 98.2% in the stent and 94.9% in the PTCA group. Immediate and follow-up angiographic data showed that acute gain was significantly higher in the stent than in the PTCA group (1.95 vs. 1.5 mm; p < 0.03). However, late loss was significantly higher in the stent than the PTCA group (0.63+/-0.59 vs. 0.26+/-0.44, respectively; p=0.01). Hence, net gain with both techniques was similar (1.32< or =0.3 vs. 1.24+/-0.29 mm for the stent and the PTCA groups, respectively; p=NS). Angiographic restenosis rate at follow-up (19.2% in stent vs. 16.4% in PTCA; p=NS) and TVR (17.5% in stent vs. 13.5% in PTCA; p=NS) were similar. Furthermore, event-free survival was 80.8% in the stent versus 83.1% in the PTCA group (p=NS). Overall costs (hospital and follow-up) were US $591,740 in the stent versus US $398,480 in the PTCA group (p < 0.02). CONCLUSIONS: The strategy of PTCA with delay angiogram and provisional stent if early loss occurs had similar restenosis rate and TVR, but lower cost than primary stenting after PTCA.  相似文献   

11.
Registries of excimer laser coronary angioplasty have reported good results in the treatment of complex coronary artery disease, including total or subtotal coronary occlusions. One hundred three patients (103 lesions) with a functional or total coronary occlusion were included in a randomized trial (Amsterdam-Rotterdam [AMRO] trial, total of 308 patients), 49 patients were allocated to laser angioplasty and 54 patients to balloon angioplasty. The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomized segment during a 6-month follow-up period. The primary angiographic end point was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by an automated contour-detection algorithm. Laser angioplasty was followed by balloon angioplasty in all procedures. The angiographic success rate was 65% in patients treated with excimer laser-assisted balloon angioplasty compared with 61% in patients treated with balloon angioplasty alone. No deaths occurred. There were no significant differences between the laser angioplasty group and the balloon angioplasty group in the incidence of myocardial infarctions (1 patient vs 3, respectively, p = 0.36), coronary bypass surgery (4 patients vs 2, respectively, p = 0.34), repeat angioplasty (10 patients vs 8, respectively, p = 0.46) or primary clinical end point (15 patients vs 12, respectively, p = 0.34). The net gain in minimal lumen diameter and restenosis rate (>50% diameter stenosis at follow-up) were 0.81 +/- 0.74 mm and 66.7%, respectively, in patients treated with laser angioplasty compared with 1.04 +/- 0.68 mm and 48.5%, respectively, in patients treated with balloon angioplasty (p = 0.59 and p = 0.15, respectively). Excimer laser-assisted balloon angioplasty demonstrated no benefit over balloon angioplasty with respect to initial and long-term clinical and angiographic outcome in the treatment of patients with functional or total coronary occlusions of >10 mm in length.  相似文献   

12.
Management of in-stent restenosis has become a significant challenge in interventional cardiology. The results of balloon angioplasty have been disappointing due to the high recurrence of restenosis at follow-up. Debulking of the restenotic tissue within the stents using directional coronary atherectomy (DCA) may offer a therapeutic advantage. We report the immediate clinical and angiographic outcomes and long-term clinical follow-up results of 45 patients (46 lesions), mean age 63+/-12 years, 73% men, with a mean reference diameter of 2.9+/-0.6 mm, treated with DCA for symptomatic Palmaz-Schatz in-stent restenosis. DCA was performed successfully in all 46 lesions and resulted in a postprocedural minimal luminal diameter of 2.7+/-0.7 mm and a residual diameter stenosis of 17+/-10%. There were no in-hospital deaths, Q-wave myocardial infarctions, or emergency coronary artery bypass surgeries. Four patients (9%) suffered a non-Q-wave myocardial infarction. Target lesion revascularization was 28.3% at a mean follow-up of 10+/-4.6 months. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and repeat target lesion revascularization) was 71.2% and 64.7% at 6 and 12 months after DCA, respectively. Thus, DCA is safe and efficacious for the treatment of Palmaz-Schatz in-stent restenosis. It results in a large postprocedural minimal luminal diameter and a low rate of both target lesion revascularization and combined major clinical events at follow-up.  相似文献   

13.
BACKGROUND: The new, less shortening, self-expanding Wallstent is characterized by longitudinal flexibility, a protective membrane, a low profile, and a customized range of diameters (3.5 to 6.0 mm). The recent modification of the braiding angle of the Wallstent has resulted in a new device with less shortening on expansion and a concomitant reduction in radial force. We hypothesized that the enforced mechanical remodeling produced by the selection of an oversized Wallstent might result in improved accommodation of subsequent reactive intimal hyperplasia and prevention of chronic recoil of the vessel. METHODS AND RESULTS: To prove this hypothesis, we recently implanted 44 new, less shortening Wallstents in 35 native coronary arteries in 35 patients with acute or threatened closure after balloon angioplasty, according to a strategy of oversizing of Wallstent diameter and complete coverage of the lesion length. The initial and 6-month follow-up angiograms were analyzed with a computer-based quantitative coronary angiography (QCA) system. Acute gain (minimal luminal diameter [MLD] post minus MLD pre) and late loss (MLD post minus MLD at follow-up) were examined. Stent deployment was successful in 44 of 44 attempts (100%). Nominal stent diameter used was 1.40 mm larger than the maximal vessel diameter. One patient (3%) with a dilated but unstented lesion proximal to the stented segment sustained a subacute occlusion on day 1 associated with myocardial infarction. Event-free survival at 30 days after stent implantation was 97% (34 of 35 patients). Of the 34 patients eligible for 6-month angiographic follow-up, 3 who were asymptomatic declined repeat angiography. MLD (and percent diameter stenosis [% DS]) changed from 0.83 +/- 0.50 mm (72%) pre through 3.06 +/- 0.48 mm (15%) post to 2.27 +/- 0.74 mm (28%) at follow-up. Acute gain was 2.23 +/- 0.63 mm, and late loss was 0.78 +/- 0.61 mm. Angiographic restenosis ( > 50% DS) was observed in 5 of 31 patients (16%) at 6 months, all of whom underwent repeat angioplasty. Thus, the overall event-free survival at 6-month follow-up was 83% (29 of 35 patients). CONCLUSIONS: The oversized Wallstent implantation with complete coverage of the lesion length conveyed a favorable 6-month clinical and angiographic outcome. The large acute gain obtained by the Wallstent afforded greater accommodation of the subsequent late loss. The enforced mechanical remodeling by oversized new Wallstents may result in prevention of acute and chronic recoil of the vessel wall and subsequently a lower restenosis rate at follow-up.  相似文献   

14.
Catheter-based radiotherapy to inhibit restenosis after coronary stenting   总被引:1,自引:0,他引:1  
BACKGROUND: In animal models of coronary restenosis, intracoronary radiotherapy has been shown to reduce the intimal hyperplasia that is a part of restenosis. We studied the safety and efficacy of catheter-based intracoronary gamma radiation plus stenting to reduce coronary restenosis in patients with previous restenosis. METHODS: Patients with restenosis underwent coronary stenting, as required, and balloon dilation and were then randomly assigned to receive catheter-based irradiation with iridium-192 or placebo. Clinical follow-up was performed, with quantitative coronary angiographic and intravascular ultrasonographic measurements at six months. RESULTS: Fifty-five patients were enrolled; 26 were assigned to the iridium-192 group and 29 to the placebo group. Angiographic studies were performed in 53 patients (96 percent) at a mean (+/-SD) of 6.7+/-2.2 months. The mean minimal luminal diameter at follow-up was larger in the iridium-192 group than in the placebo group (2.43+/-0.78 mm vs. 1.85+/-0.89 mm, P=0.02). Late luminal loss was significantly lower in the iridium-192 group than in the placebo group (0.38+/-1.06 mm vs. 1.03+/-0.97 mm, P=0.03). Angiographically identified restenosis (stenosis of 50 percent or more of the luminal diameter at follow-up) occurred in 17 percent of the patients in the iridium-192 group, as compared with 54 percent of those in the placebo group (P= 0.01). There were no apparent complications of the treatment. CONCLUSIONS: In this preliminary, short-term study of patients with previous coronary restenosis, coronary stenting followed by catheter-based intracoronary radiotherapy substantially reduced the rate of subsequent restenosis.  相似文献   

15.
BACKGROUND: Diabetes is a major risk factor for restenosis after coronary balloon angioplasty. Recent studies have shown that coronary stenting significantly reduces restenosis compared with balloon angioplasty alone. However, limited information is available on the effect of coronary stenting in diabetic patients. METHODS AND RESULTS: We designed this study to analyze the effect of diabetes on restenosis in patients treated with either balloon angioplasty or coronary stenting who were enrolled in a 6-month angiographic follow-up program. Three hundred consecutive patients, 19% of whom were diabetics, who underwent coronary stent implantation during a single-vessel procedure on native coronary vessels and who had 6-month angiographic follow-up constituted the study group (stent group). Three hundred consecutive patients who underwent 6-month angiographic follow-up after single-vessel conventional balloon angioplasty served as control patients (balloon group). Preprocedural, postprocedural, and follow-up angiograms were analyzed with quantitative angiography. In the balloon group, the restenosis rate was almost twofold higher in diabetic than in nondiabetic patients (63% versus 36%; P=.0002) owing to both a greater late loss (0.79+/-0.70 versus 0.41+/-0.61 mm, respectively; P<.0001) and a higher rate of late vessel occlusion (14% versus 3%, respectively; P<.001). In the stent group, restenosis rates were similar in diabetics and nondiabetics (25% versus 27%, respectively). Furthermore, in the stent group, late loss (0.77+/-0.65 versus 0.79+/-0.57 mm, respectively) and the rate of late vessel occlusion (2% versus 1%, respectively) did not differ significantly between diabetic and nondiabetic patients. CONCLUSIONS: Although diabetics have increased rates of restenosis and late vessel occlusion after simple balloon angioplasty, they have the same improved outcome with coronary stenting that has been documented in nondiabetic patients.  相似文献   

16.
Aggressive balloon dilatation is currently performed to assure full stent expansion and minimize the risk of stent thrombosis. It is not known if aggressive stent expansion leads to further increases in intimal proliferation and restenosis. A retrospective analysis was performed of 688 consecutive coronary narrowings in which stents were implanted. Angiographic follow-up was performed and quantitative coronary angiographic measurements were obtained using electronic calipers. Patients were divided into 2 groups. Group A (212 narrowings) had stents implanted before 1993, before the routine use of aggressive stent expansion techniques. Group B (476 narrowings) had stents implanted after 1993, when oversized balloons or high-pressure inflations were performed inside stents. Comparisons were made between angiographic changes and clinical outcomes between the 2 groups. Group B lesions had less favorable characteristics due to longer lengths of lesions. Despite this there was less angiographic and clinical restenosis in this cohort. There was no difference in late loss between the 2 groups. Thus, aggressive stent implantation techniques were not associated with increased late loss or restenosis.  相似文献   

17.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

18.
Secondary to the low attrition rate of internal mammary artery grafts, limited data are available on the clinical and angiographic outcome of patients who have undergone balloon angioplasty of an internal mammary artery stenosis. This study examined a consecutive series of 68 patients who underwent balloon angioplasty of an internal mammary artery graft over a 9-year period. Procedural success was achieved in 60 of 68 (88%) patients. The primary reason for procedural failure was extreme vessel tortuosity. There were no major in-hospital complications. Angiographic follow-up was obtained in 78% of the patients with an angiographic restenosis rate of 19%. The overall event-free survival in patients with an initially successful procedure was 92%. In conclusion, internal mammary artery balloon angioplasty has both an excellent initial success rate as well as a low incidence of restenosis and repeat target lesion revascularization.  相似文献   

19.
With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.  相似文献   

20.
OBJECTIVES: We sought to determine predictors of restenosis after coronary stenting (CS) in a consecutive series of patients. BACKGROUND: Although stenting in highly selected patient groups reduces restenosis, the results of stenting in a heterogeneous patient group and the effects of clinical and procedural factors on stent restenosis are currently unclear. METHODS: We analyzed the 6-month angiographic outcome of 500 lesions in 463 consecutive patients undergoing successful CS. Clinical, qualitative and quantitative angiographic variables were correlated with restenosis assessed as both a binary and a continuous variable. RESULTS: Restenosis, defined as the presence of >50% diameter stenosis in the dilated segment, was present in 105 (26%) of the 405 lesions with angiographic follow-up. The mean late lumen loss during the follow-up period was 0.79+/-0.64 mm. Implantation of multiple stents (p < 0.0001) and a high acute gain (p < 0.0002) were independently associated with a higher late lumen loss. In contrast, the use of high inflation pressure (p < 0.02) and Palmaz-Schatz stents (p < 0.005) was independently associated with a lower late lumen loss. When restenosis was defined as a qualitative variable, implantation of multiple stents (p < 0.001), stenosis length (p < 0.01), small reference diameter (p < 0.02) and stent type other than Palmaz-Schatz (p < 0.01) were independent predictors of restenosis. None of the clinical variables tested was associated with restenosis. CONCLUSIONS: Coronary stenting in an unselected patient group is associated with an acceptable restenosis rate. Although some risk factors were identified, the risk of restenosis was not related to most of the variables tested. This suggests that the superiority of CS over balloon angioplasty, in terms of restenosis, might also apply to subgroups of patients that were not included in the recent randomized studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号