1.
Objective

To evaluate the feasibility of in-vivo quantitative susceptibility mapping (QSM) of the human kidney.

Methods

An axial single-breath-hold 3D multi-echo sequence (acquisition time 33 s) was completed on a 3 T-MRI-scanner (Magnetom Prisma, Siemens Healthineers, Erlangen, Germany) in 19 healthy volunteers. Graph-cut-based unwrapping combined with the T2*-IDEAL approach was performed to remove the chemical shift of fat and to quantify QSM of the upper abdomen. Mean susceptibility values of the entire, renal cortex and medulla in both kidneys and the liver were determined and compared. Five subjects were measured twice to examine the reproducibility. One patient with severe renal fibrosis was included in the study to evaluate the potential clinical relevance of QSM.

Results

QSM was successful in 17 volunteers and the patient with renal fibrosis. Anatomical structures in the abdomen were clearly distinguishable by QSM and the susceptibility values obtained in the liver were comparable to those found in the literature. The results showed a good reproducibility. Besides, the mean renal QSM values obtained in healthy volunteers (0.04?±?0.07 ppm for the right and ? 0.06?±?0.19 ppm for the left kidney) were substantially higher than that measured in the investigated fibrotic kidney (? 0.43?±?? 0.02 ppm).

Conclusion

QSM of the human kidney could be a promising approach for the assessment of information about microscopic renal tissue structure. Therefore, it might further improve functional renal MR imaging.

  相似文献   

2.
Purpose

To improve the precision of a free-breathing 3D saturation-recovery-based myocardial T1 mapping sequence using a post-processing 3D denoising technique.

Methods

A T1 phantom and 15 healthy subjects were scanned on a 1.5 T MRI scanner using 3D saturation-recovery single-shot acquisition (SASHA) for myocardial T1 mapping. A 3D denoising technique was applied to the native T1-weighted images before pixel-wise T1 fitting. The denoising technique imposes edge-preserving regularity and exploits the co-occurrence of 3D spatial gradients in the native T1-weighted images by incorporating a multi-contrast Beltrami regularization. Additionally, 2D modified Look-Locker inversion recovery (MOLLI) acquisitions were performed for comparison purposes. Accuracy and precision were measured in the myocardial septum of 2D MOLLI and 3D SASHA T1 maps and then compared. Furthermore, the accuracy and precision of the proposed approach were evaluated in a standardized phantom in comparison to an inversion-recovery spin-echo sequence (IRSE).

Results

For the phantom study, Bland–Altman plots showed good agreement in terms of accuracy between IRSE and 3D SASHA, both on non-denoised and denoised T1 maps (mean difference −1.4 ± 18.9 ms and −4.4 ± 21.2 ms, respectively), while 2D MOLLI generally underestimated the T1 values (69.4 ± 48.4 ms). For the in vivo study, there was a statistical difference between the precision measured on 2D MOLLI and on non-denoised 3D SASHA T1 maps (P = 0.005), while there was no statistical difference after denoising (P = 0.95).

Conclusion

The precision of 3D SASHA myocardial T1 mapping was substantially improved using a 3D Beltrami regularization based denoising technique and was similar to that of 2D MOLLI T1 mapping, while preserving the higher accuracy and whole-heart coverage of 3D SASHA.

  相似文献   

3.
The aim of this study was to compare conventional spin-echo (CSE)T 2-weighted (T2W) images with turbo spin-echo (TSE) T2W pulse sequences in their ability to detect focal liver lesions. Seventy-eight consecutive patients with focal liver lesions were entered into this study. All patients were imaged using the gradient-echo (GE) sequence with the breath-hold technique forT 1-weighted (T1W) images, and CSE and TSE sequences for T2W images. Qualitative evaluation included lesion detection (number of lesions detected) and conspicuity (extent of visualization of lesional borders); quantitative evaluation included the signal-to-noise (S/N) ratio and the contrast-to-noise (C/N) ratio. TSE showed the best performance in terms of lesion detection; however, the difference between TSE and CSE was significant only in the case of benign cysts (p<0.01). Conspicuity was higher with TSE and CSE, and lower with GE. The S/N and C/N ratios of the two T2W sequences were also comparable, and better than those of GE. However, the combined use of GE and TSE resulted in improved lesion detection. The results show that, because the acquisition time is greatly reduced with TSE sequences, these should be considered as first-line approach to magnetic resonance imaging of the liver for the study of focal lesions.  相似文献   

4.
Using a simple modification of a standard spin-echo sequence which enables acquisition of three breath-hold images in 15 s, dynamic enhancement of 30 histologically proven hepatocellular carcinomas (17 native tumors, 6 completely necrotic tumors after nonsurgical treatments, and 7 tumors with viable and necrotic portions) after intravenous injection of gadolinium-DTPA was evaluated. Native hepatocellular carcinomas and viable portions in treated nodules showed elective enhancement in images obtained 40 s after contrast injection. Contrast between these lesions and the normal liver decreased thereafter. No contrast uptake was seen in entirely necrotic nodules and necrotic portions of treated nodules. Because of the capability to demonstrate the elective arterial blood supply typical of hepatocellular carcinoma, breath-holdT 1-weighted spin-echo sequence should replace conventionalT 1-weighted images for the evaluation of intravenously administered gadolinium-DTPA enhancement of this tumor before and after nonsurgical treatments.  相似文献   

5.
Purpose: To evaluate the feasibility of the phase difference-based post-processing water-fat imaging method for fat suppression at low-field in imaging of arthritic joints.Materials and methods: Thirty joints (wrist, 10; elbow, 10; knee, 10) in 30 patients with rheumatoid arthritis were imaged using a 0.23TMRI unit. Contrast-enhanced Tl-weighted (Tlw) three-dimensional (3D) gradient-echo (GRE) images with and without fat suppression along with short inversion time inversion-recovery (STIR) images were evaluated by two radiologists. Contrast-enhanced Tlw 3D GRE images and corresponding post-processed fat-suppressed images were scored for conspicuity and delineation of enhancing synovial hypertrophy. The uniformity of fat suppression was evaluated between Tlw 3D GRE fat-suppressed images and STIR images, and general image quality was estimated for all of the three techniques by consensus. For a quantitative analysis, the enhancing synovial hypertrophy-to-fat contrast-to-noise (CNR) values for the T1W 3D GRE images with and without fat suppression were measured. For comparison, synovial bright signal-to-fat CNR values for the STIR images were measured.Results: The post-processing water-fat imaging technique for fat suppression was successfully applied in all examinations. Conspicuity and delineation of enhancing tissue were superior in fat-suppressed Tlw 3D GRE images compared to non-fat-suppressed images (P < 0.0001). As expected, the enhancing synovial hypertrophy tissue-to-fat CNRs were significantly higher in fat-suppressed Tlw 3D GRE images compared to non-fat-suppressed images (P < 0.0001). General image quality was assessed to be best in non-fat-suppressed images, and the difference was significant compared to fat-suppressed images (P < 0.05) and STIR images (P < 0.05).Conclusion: The phase difference-based post-processing water-fat imaging technique for fat suppression can be successfully used at low-field, and it provides high-quality fat suppression images in imaging of arthritic joints.  相似文献   

6.
A sample of 20 bovine ovaries were imaged in vitro using nuclear magnetic resonance (NMR) techniques to determine the visibility of various physiologic structures. In particular, the possibility of using NMR imaging to differentiate atretic follicles from physiologically selected and ovulatory follicles was examined. Five of the 20 ovaries were preserved in formalin, whereas the remaining 15 were preserved in a saline solution and imaged within 18 hours of death. Images weighted by T1 and T2 proton spin relaxation rates were obtained along with some three-dimensional (3-D) data sets acquired via a fast imaging with steady-state precession technique. Physiologically different structures were easily identified in the images from their morphology, especially in the 3-D images. Weighting by T1 and T2 was able to separate structures in the fresh ovaries in the following manner. Atretic and cohort follicles appear dark in T1-weighted images and bright in T2-weighted images. Ovulatory follicles appear bright in both T1-and T2-weighted images, whereas prephysiologic selection follicles present an intermediate brightness in T1-weighted images and appear dark in T2-weighted images. The corpus luteum appears bright in T1-weighted images and dark in T2-weighted images, whereas cysts in the corpus luteum appear dark in T1-weighted images and bright in T2-weighted images. The varying brightness of the follicles at different stages of development is hypothesized to be related to different hormone and protein concentrations in the follicular fluid. For example, it is known that physiologically selected preovulatory follicles contain high concentrations of estrogens in a viscous follicular fluid. The increased viscosity may occur only when the follicle fluid contains high concentrations of estrogen and contributes to bright T1-weighted images. The possibility of using nuclear relaxation-weighted NMR imaging for the study of follicular dynamics and other ovarian biology therefore shows great promise.  相似文献   

7.
Object: Demonstrating the feasibility of magnetic resonance imaging (MRI) at 1.5 T of ultrasmall particle iron oxide (USPIO)-antibody bound to tumor cells in vitro and in a murine xenotransplant model. Methods: Human D430B cells or Raji Burkitt lymphoma cells were incubated in vitro with different amounts of commercially available USPIO-anti-CD20 antibodies and cell pellets were stratified in a test tube. For in vivo studies, D430B cells and Raji lymphoma cells were inoculated subcutaneously in immunodeficient mice. MRI at 1.5 T was performed with T1-weighted three-dimensional fast field echo sequences (17/4.6/13°) and T2-weighted three-dimensional fast-field echo sequences (50/12/7°). For in vivo studies MRI was performed before and 24 h after USPIO-anti-CD20 administration. Results: USPIO-anti-CD20-treated D430B cells, showed a dose-dependent decrease in signal intensity (SI) on T2*-weighted images and SI enhancement on T1-weighted images in vitro. Raji cells showed lower SI changes, in accordance to the fivefold lower expression of CD20 on Raji with respect to D430B cells. In vivo 24 h after USPIO-anti-CD20 administration, both tumors showed an inhomogeneous decrease of SI on T2*-weighted images and SI enhancement on T1-weighted images. Conclusions: MRI at 1.5 T is able to detect USPIO-antibody conjugates targeting a tumor-associated antigen in vitro and in vivo.  相似文献   

8.
9.
Gommlich  A.  Raschke  F.  Petr  J.  Seidlitz  A.  Jentsch  C.  Platzek  I.  van den Hoff  J.  Kotzerke  J.  Beuthien-Baumann  B.  Baumann  M.  Krause  M.  Troost  E. G. C. 《Magma (New York, N.Y.)》2022,35(1):145-152
Objective

Brain atrophy has the potential to become a biomarker for severity of radiation-induced side-effects. Particularly brain tumour patients can show great MRI signal changes over time caused by e.g. oedema, tumour progress or necrosis. The goal of this study was to investigate if such changes affect the segmentation accuracy of normal appearing brain and thus influence longitudinal volumetric measurements.

Materials and methods

T1-weighted MR images of 52 glioblastoma patients with unilateral tumours acquired before and three months after the end of radio(chemo)therapy were analysed. GM and WM volumes in the contralateral hemisphere were compared between segmenting the whole brain (full) and the contralateral hemisphere only (cl) with SPM and FSL. Relative GM and WM volumes were compared using paired t tests and correlated with the corresponding mean dose in GM and WM, respectively.

Results

Mean GM atrophy was significantly higher for full segmentation compared to cl segmentation when using SPM (mean ± std: ΔVGM,full = − 3.1% ± 3.7%, ΔVGM,cl = − 1.6% ± 2.7%; p < 0.001, d = 0.62). GM atrophy was significantly correlated with the mean GM dose with the SPM cl segmentation (r = − 0.4, p = 0.004), FSL full segmentation (r = − 0.4, p = 0.004) and FSL cl segmentation (r = -0.35, p = 0.012) but not with the SPM full segmentation (r = − 0.23, p = 0.1).

Conclusions

For accurate normal tissue volume measurements in brain tumour patients using SPM, abnormal tissue needs to be masked prior to segmentation, however, this is not necessary when using FSL.

  相似文献   

10.
T 1-weighted images of the human brain obtained with the MDEFT sequence at 8 T are presented. These images are characterized by an excellent contrast and good signal to noise ratio. Importantly, results were obtained with adiabatic spin inversion and demonstrate that such pulses can be used event in the ultra high frequency (>300 MHz) range. It is thus possible to obtain high quality results at this field strength without violating SAR guidelines.  相似文献   

11.
Objectives: After I.V. administration of gadolinium-DOTA, the early contrast enhancement pattern and related signal-intensity (SI) changes in normal abdominal organs (kidney, spleen, liver) are evaluated over the first 4 min by using ultrafast spin-echo echo planar imaging (SE-EPI). Methods: On a 1.5-T magnetic resonance unit ultrafast EPI of the upper abdomen was performed in 12 patients in order to show the contrast enhancement pattern and related measurable SI changes onT 1 andT 2-weighted (w) images over the first 4 min after I.V. bolus injection of 0.1 mmol kg–1 gadolinium (Gd)-DOTA in the spleen, liver, renal cortex, and renal medulla. A TR/TE of 500/44 or 45 ms inT 1w SE-EPI and a TR/TE of 2000/80 or 100 ms inT 2-w SE-EPI were used. Results: Typical time-dependent SI changes were noticed onT 1w images: Subsequent to a SI increase in the renal cortex (starting 7 s after the I.V. injection of Gd-DOTA) SI increased first in the outer renal medulla (6 s later) and then in the inner renal medulla (21 s later). A SI increase was observed in the spleen (starting after 15 s) and in the liver (starting 7 s later). OnT 2-w images, a SI decrease in the renal cortex (starting after 14 s) was followed by migration of a dark band from the outer (after 46 s) to the inner medulla (after 70 s). Only minimal changes were noticed in the spleen and liver. Conclusions: Ultrafast SE-EPI following I.V. bolus injection of Gd-DOTA enables the observation of the very early contrast agent kinetics in various abdominal organs. The associated SI changes onT 1- andT 2- SE EPI are related to organ perfusion and contrast agent tissue concentration and biodistribution.Additional reprints of this chapter may be obtained from the Reprints Department, Chapman & Hall, One Penn Plaza, New York, NY 10119.  相似文献   

12.
Abstract

Lead-free 0.88BaTiO3–(0.12-x)BaZrO3xCaTiO3 (BT-BZ-xCT) ceramics were fabricated via solid state reaction. The effect of CaTiO3 content on crystal structure, phase transition, and electrical properties was investigated systematically. The crystal structure and phase transition of ceramics were characterized by X-ray diffraction (XRD), Raman spectra and dielectric measurement. Results show that ceramic in the composition, x?=?0.02, exhibits a rhombohedral structure. Ceramics with increasing CT content transformed from a rhombohedral to orthorhombic structure in the composition, x?=?0.04, and eventually became a tetragonal structure at the composition, x?≥?0.08. The polymorphic phase boundary (PPB) was observed at the composition, x?=?0.06, with coexistence of orthorhombic and tetragonal phases showing at almost room temperature. This PPB composition exhibited a high piezoelectric response (d33*) of 1,150?pm/V at 10?kV/cm as an electric field was applied. These results indicate that the materials studied have potential as candidates for lead-free piezoelectric ceramics.  相似文献   

13.
Abstract

The effects of sputtering conditions on the SrBi2Ta2O9 films deposited via a single-target RF-sputtering process were investigated in this study. It was found that the composition of targets significantly affected the phases and the composition of the deposited films. When the target contained high bismuth content, SrBi2Ta2O9 and a secondary Bi2O3 phase were formed. When the bismuth content in the targets was insufficient, a pyrochlore phase was produced. SEM images revealed that the composition of the targets also affected the surface morphology of the obtained films. When the target-to-substrate distance was increased, bismuth oxide was formed, which resulted in an increase in the leakage current. By optimizing the deposition conditions, the ferroelectric properties of SrBi2Ta2O9 films were improved.  相似文献   

14.
Objective

A method for Orthogonal Phase Encoding Reduction of Artifact (OPERA) was developed and tested.

Materials and methods

Because the position of ghosts and aliasing artifacts is predictable along columns or rows, OPERA combines the intensity values of two images acquired using the same parameters, but with swapped phase-encoding directions, to correct the artifacts. Simulations and phantom experiments were conducted to define the efficacy, robustness, and reproducibility. Clinical validation was performed on a total of 1003 images by comparing the OPERA-corrected images and the corresponding image standard in terms of Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR). The method efficacy was also rated using a Likert-type scale response by two experienced independent radiologists using a single-blinded procedure.

Results

Simulations and phantom experiments demonstrated the robustness and effectiveness of OPERA in reducing artifacts strength. OPERA application did not significantly change the SNR [+?4.16%; inter-quartile range (IQR): 2.72–5.01%] and CNR (+?4.30%; IQR: 2.86–6.04%) values. The two radiologists observed a total of 893 original images with artifacts (89.03% of the total images), a reduction in the perceived artifacts of 82.0% and 83.9% (p?<?0.0001), and an improvement in the perceived SNR (82.8% and 88.5%; K?=?0.714) and perceived CNR (86.9–88.9%; K?=?0.722).

Discussion

The study demonstrated that OPERA reduces MR artifacts and improves the perceived image quality.

  相似文献   

15.
Objective

To implement magnetic resonance fingerprinting (MRF) on a permanent magnet 50 mT low-field system deployable as a future point-of-care (POC) unit and explore the quality of the parameter maps.

Materials and methods

3D MRF was implemented on a custom-built Halbach array using a slab-selective spoiled steady-state free precession sequence with 3D Cartesian readout. Undersampled scans were acquired with different MRF flip angle patterns and reconstructed using matrix completion and matched to the simulated dictionary, taking excitation profile and coil ringing into account. MRF relaxation times were compared to that of inversion recovery (IR) and multi-echo spin echo (MESE) experiments in phantom and in vivo. Furthermore, B0 inhomogeneities were encoded in the MRF sequence using an alternating TE pattern, and the estimated map was used to correct for image distortions in the MRF images using a model-based reconstruction.

Results

Phantom relaxation times measured with an optimized MRF sequence for low field were in better agreement with reference techniques than for a standard MRF sequence. In vivo muscle relaxation times measured with MRF were longer than those obtained with an IR sequence (T1: 182 ± 21.5 vs 168 ± 9.89 ms) and with an MESE sequence (T2: 69.8 ± 19.7 vs 46.1 ± 9.65 ms). In vivo lipid MRF relaxation times were also longer compared with IR (T1: 165 ± 15.1 ms vs 127 ± 8.28 ms) and with MESE (T2: 160 ± 15.0 ms vs 124 ± 4.27 ms). Integrated ΔB0 estimation and correction resulted in parameter maps with reduced distortions.

Discussion

It is possible to measure volumetric relaxation times with MRF at 2.5 × 2.5 × 3.0 mm3 resolution in a 13 min scan time on a 50 mT permanent magnet system. The measured MRF relaxation times are longer compared to those measured with reference techniques, especially for T2. This discrepancy can potentially be addressed by hardware, reconstruction and sequence design, but long-term reproducibility needs to be further improved.

  相似文献   

16.
Introduction

Various research sites are pursuing 14 T MRI systems. However, both local SAR and RF transmit field inhomogeneity will increase. The aim of this simulation study is to investigate the trade-offs between peak local SAR and flip angle uniformity for five transmit coil array designs at 14 T in comparison to 7 T.

Methods

Investigated coil array designs are: 8 dipole antennas (8D), 16 dipole antennas (16D), 8 loop coils (8D), 16 loop coils (16L), 8 dipoles/8 loop coils (8D8L) and for reference 8 dipoles at 7 T. Both RF shimming and kT-points were investigated by plotting L-curves of peak SAR levels vs flip angle homogeneity.

Results

For RF shimming, the 16L array performs best. For kT-points, superior flip angle homogeneity is achieved at the expense of more power deposition, and the dipole arrays outperform the loop coil arrays.

Discussion and conclusion

For most arrays and regular imaging, the constraint on head SAR is reached before constraints on peak local SAR are violated. Furthermore, the different drive vectors in kT-points alleviate strong peaks in local SAR. Flip angle inhomogeneity can be alleviated by kT-points at the expense of larger power deposition. For kT-points, the dipole arrays seem to outperform loop coil arrays.

  相似文献   

17.
Objective

The aim of the study was to evaluate feasibility of diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) method in diagnosing Hodgkin lymphoma in pediatric patients and to compare it with 18F-FDG PET/CT as a gold standard.

Materials and methods

Eleven patients (median age 14) with newly diagnosed Hodgkin lymphoma were examined with 18F-FDG PET/CT and MRI including whole-body DWIBS sequence (b = 0, 800 s/mm2), before the oncologic treatment. About 26 locations of lymphatic tissues were evaluated visually and quantitatively using ADCmean (DWIBS) and SUVmax (18F-FDG PET/CT), respectively.

Results

All affected lymph node regions (n = 134) diagnosed in 18F-FDG PET/CT were found with DWIBS, presenting decreased diffusion. Significant correlation was found between ADC and SUV values (R2 = − 0.37; p = 0.0001). Nevertheless, additional 33 regions were recognized only by DWIBS. They were significantly smaller than regions diagnosed by both methods.

Discussion

Agreement between DWIBS and 18F-FDG PET/CT for detection and staging of malignant lymphoma is high. DWIBS can be used for the evaluation of pediatric Hodgkin lymphoma.

  相似文献   

18.
Objective

Recent work showed the feasibility of measuring velocity pulsatility in the perforating arteries at the level of the BG using 3T MRI. However, test–retest measurements have not been performed, yet. This study assessed the test–retest reliability of 3T MRI blood flow velocity measurements in perforating arteries in the BG.

Materials and methods

Two-dimensional phase-contrast cardiac gated (2D-PC) images were acquired for 35 healthy controls and repeated with and without repositioning. 2D-PC images were processed and analyzed, to assess the number of detected perforating arteries (Ndetected), mean blood flow velocity (Vmean), and velocity pulsatility index (vPI). Paired t-tests and Bland–Altman plots were used to compare variance in outcome parameters with and without repositioning, and limits of agreement (LoA) were calculated.

Results

The LoA was smallest for Vmean (35%) and highest for vPI (79%). Test–retest reliability was similar with and without repositioning of the subject.

Discussion

We found similar LoA with and without repositioning indicating that the measurement uncertainty is dominated by scanner and physiological noise, rather than by planning. This enables to study hemodynamic parameters in perforating arteries at clinically available scanners, provided sufficiently large sample sizes are used to mitigate the contribution of scanner- and physiological noise.

  相似文献   

19.
Objective

19F MRI requires biocompatible and non-toxic soluble contrast agents with high fluorine content and with suitable 19F relaxation times. Probes based on a DOTP chelate with 12 magnetically equivalent fluorine atoms (DOTP-tfe) and a lanthanide(III) ion shortening the relaxation times were prepared and tested.

Methods

Complexes of DOTP-tfe with trivalent paramagnetic Ce, Dy, Ho, Tm, and Yb ions were synthetized and characterized. 19F relaxation times were determined and compared to those of the La complex and of the empty ligand. In vitro and in vivo 19F MRI was performed at 4.7 T.

Results

19F relaxation times strongly depended on the chelated lanthanide(III) ion. T1 ranged from 6.5 to 287 ms, T2 from 3.9 to 124.4 ms, and T2* from 1.1 to 3.1 ms. All complexes in combination with optimized sequences provided sufficient signal in vitro under conditions mimicking experiments in vivo (concentrations 1.25 mM, 15-min scanning time). As a proof of concept, two contrast agents were injected into the rat muscle; 19F MRI in vivo confirmed the in vivo applicability of the probe.

Conclusion

DOTP-based 19F probes showed suitable properties for in vitro and in vivo visualization and biological applications. The lanthanide(III) ions enabled us to shorten the relaxation times and to trim the probes according to the actual needs. Similar to the clinically approved Gd3+ chelates, this customized probe design ensures consistent biochemical properties and similar safety profiles.

  相似文献   

20.
Purpose: This study assessed the value of high-resolution magnetic resonance imaging (MRI) of the distal colon by means of a dedicated endoluminal magnetic resonance receiver coil on a 1.5-T clinical scanner. Materials and Methods: To this end, single-loop, receive-only radio-frequency coils, housed in 18 F sheaths, were built. A 1.5-T clinical imager was used. A 18 French diameter internal MRI receiver coil was inserted into the distal colon in 15 New Zealand rabbits to obtain high-resolution magnetic resonance images by using T1-weighted Flash sequences with and without Fat Saturation (FS), T2-weighted True-Fisp, turbo spin-echo, and T1-weighted Flash FS after contrast media injection. Images were compared to histological sections. Results: An adequate image quality was obtained in all specimens without significant artefacts. Based on histological reports, a five-layer structure of the wall was considered normal. On different MR sequences, only two layers were identified on the images of all rabbits specimens. The nearest layer to the mucosal surface was usually seen as a hyper intense layer and likely corresponds to the mucosa. The highest difference of signal value between internal and external layers was performed on 2D Fat saturation T1 weighted gradient echo. Comparison of mean signal value between the internal and external layers was statistically different in for each sequence used in our protocol (P< 0.05). Conclusion: Dedicated endoluminal RF coil provides good spatial resolution at the region of interest. On this prospective study of in vivo rabbit, evaluation of colon walls allowed to provide detailed information.  相似文献   