首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
An experimental analysis is presented to establish the thermal performance of a latent heat thermal storage (LHTS) unit. Paraffin is used as the phase change material (PCM) on the shell side of the shell and tube‐type LHTS unit while water is used as the heat transfer fluid (HTF) flowing through the inner tube. The fluid inlet temperature and the mass flow rate of HTF are varied and the temperature distribution of paraffin in the shell side is measured along the radial and axial direction during melting and solidification process. The total melting time is established for different mass flow rates and fluid inlet temperature of HTF. The motion of the solid–liquid interface of the PCM with time along axial and radial direction of the test unit is critically evaluated. The experimental results indicate that the melting front moves from top to bottom along the axial direction while the solidification front moves only in the radial direction. The total melting time of PCM increases as the mass flow rate and inlet temperature of HTF decreases. A correlation is proposed for the dimensionless melting time in terms of Reynolds number and Stefan number of HTF. © 2013 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com/journal/htj ). DOI 10.1002/htj.21120  相似文献   

2.
基于列管式换热器具有传热面积大、结构紧凑、操作弹性大等优点,使其在相变储能领域具有广阔的应用前景。本文建立一种新型列管式相变蓄热器模型,在不考虑自然对流的情况下,利用Fluent软件对相变蓄热器进行二维储热过程的数值模拟。本文主要研究斯蒂芬数、雷诺数、列管排列方式、肋片数以及相变材料的导热系数对熔化过程的影响,并对熔化过程中固液分界面的移动规律进行了分析。模拟结果表明,内肋片强化换热效果明显,特别是对应用低导热系数相变材料[导热系数小于1 W/(m·K)]的列管式蓄热器,相对于无肋片结构,加入肋片(Nfn=2)可缩短熔化时间52.6%。  相似文献   

3.
A transient finite volume model was used to predict collection and retention of heat for rectangular cross section solar collector/storage systems when filled with water and various concentrations of phase change material (PCM) slurries with a 65 °C phase change temperature. It was found that the PCM slurry systems collected heat marginally less effectively than water filled stores. Retention of heat at higher temperatures in the PCM slurry systems may allow higher solar savings fractions to be realised depending on heat demand patterns.  相似文献   

4.
Nanoencapsulated phase change material (NPCM) slurry is a dispersion where the phase change material (PCM) is dispersed in fluid. Compared with fluid, these nanofluids have a higher heat capacity during the phase change and a possible enhancement, as a result of this phase change, in the heat transfer phenomenon. To appreciate the merits, in terms of energy, a numerical study has been carried out with fluid based on NPCM inside double pipe heat exchanger. The numerical simulation results have been validated using experimental heat transfer data. The Reynolds and Nusselt numbers have been determined using thermal conductivity and viscosity evaluated in the same conditions as those in numerical model. The results obtained show an improvement of this energetic criterion at low mass flow rate compared with the base fluid. Analysis of the numerical and analytical results reveal that higher inlet flow rate and NPCM concentration results in higher heat transfer rate. In addition, increasing NPCM slurry temperature decreases its performance due to fast melting of PCM inside the tube.  相似文献   

5.
H. Koizumi   《Applied Thermal Engineering》2004,24(17-18):2583-2600
The aim of this study is to reveal the temporal and spatial heat transfer performance of an isothermally heated sphere placed in a uniform, downwardly directed flow using a micro-foil heat flow sensor (HFS). A HFS, whose response time is about 0.02 s, was pasted on the surface of a heated copper sphere. Experiments were carried out using air with a Grashof number of 3.3 × 105 and with several Reynolds numbers (Re) up to 1800. Three flow patterns appeared: a chaotic flow at Re<240; a two-dimensional steady separated flow at 240 Re<500, and a three-dimensional unsteady separated flow at Re 500. In addition, the instantaneous and time-averaged heat transfer performance around the sphere in each of the three regions was clarified. Next, enhancement of the latent heat storage rate of a solid phase change material (PCM) in a spherical capsule was performed. The flow around the spherical capsule, in which the solid PCM was filled and placed in a heated, upwardly directed flow, is the approximate adverse flow phenomenon around the heated sphere which was placed in a downwardly directed flow. In other words, the buoyant flow and the forced flow are in the opposite directions in these two cases. Tests of latent heat storage were run for two Reynolds numbers which represented different flow characteristics in the heat transfer experiments, Re=150 and 1800. Furthermore, copper plates were inserted into the solid PCM, of which thermal conductivity was considerably low, to enhance the latent heat storage rate for the two Reynolds number flows.  相似文献   

6.
The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the heat transfer parameters. The experimental results proved that the PCM melts and solidifies congruently, and the melting and solidification front moved from the outer wall of the HTF pipe (HTFP) to the inner wall of the PCM container in radial distances as the melting front moved from the top to the bottom of the PCM container in axial distances. However, it was difficult to establish the solidification proceeding at the axial distances in the PCM. Though natural convection in the liquid phase played a dominant role during the melting process due to buoyancy effects, the solidification process was controlled by conduction heat transfer, and it was slowed by the conduction thermal resistance through the solidified layer. The results also indicated that the average heat transfer coefficient and the heat flow rate were affected by varying the Reynolds and Stefan numbers more during the melting process than during the solidification process due to the natural convection effect during the melting process.  相似文献   

7.
The present study aims to investigate the effect of the pulsed fluid flow on the thermal performance of a latent heat storage unit (LHSU). The storage unit consists of a shell-and-tube in which phase change material (PCM) occupied the shell space and the heat transfer fluid (HTF) flows in the inner tube. The present study is motivated by the need to intensify heat transfer and accelerate melting process in LHSU. A mathematical model based on the conservation equations of energy in both HTF and PCM has been developed. The finite volume approach was used for the discretization of equations. The developed model has been validated by comparing the obtained numerical results with experimental, analytical, and numerical data found in literature. The effects of the pulsation frequency and amplitude, the Reynolds and Stefan numbers on the thermal performance and behavior of the LHSU were investigated. The parametric study showed that the pulsating parameters (frequency and amplitude) affect the thermal performance of the LHSU. The results reveal reduction in the melting time for low pulsating frequency (less than 0.052) and high pulsating amplitude. For pulsating amplitude of 6 and pulsating frequency of 0.01, a reduction up to 13% (at Reynolds number of 500 and Stefan number of 0.16) was obtained. The results also showed that the Reynolds and Stefan numbers strongly affect the heat transfer rate, and the low melting time is obtained for high Reynolds and Stefan numbers.  相似文献   

8.
A novel technique for assessing heat transfer characteristics of salt‐based phase change materials (PCM) was proposed here. The method is based on solution to inverse heat conduction problem. Nanoparticles (Graphite, Graphene, and multi wall carbon nanotube [MWCNT]) were dispersed in the PCM (KNO3) to assess their respective influence on heat transfer in the PCM. Graphite added PCM offered highest heat flow values and heating rates, while the pure salt‐PCM offered the least. The probe material had a significant influence on the heat transfer rates at the PCM‐probe interface.  相似文献   

9.
A computational fluid dynamics (CFD) model was developed for the simulation of a phase change thermal energy storage process in a 100 l cylindrical tank, horizontally placed. The model is validated with experimental data obtained for the same configuration. The cold storage unit was charged using water as the heat transfer medium, flowing inside a horizontal tube bundle, and the selected phase change material (PCM) was microencapsulated slurry in 45% w/w concentration. The mathematical model is based on the three-dimensional transient Navier–Stokes equations with nonlinear temperature dependent thermo-physical properties of the PCM during the phase change range. These properties were experimentally determined using analytical methods. The governing equations were solved using the ANSYS/FLUENT commercial software package. The mathematical model is validated with experimental data for three different flow rates of the heat transfer fluid during the charging process. Bulk temperature, heat transfer rate and amount of energy stored were used as performance indicators. It was found that the PCM bulk temperatures were predicted within 5% of the experimental data. The results have also shown that the total accumulated energy was within 10% of the observed value, and thus it can be concluded that the model predicts the heat transfer inside the storage system with good accuracy.  相似文献   

10.
This paper examines experimentally the effect of jet vortex technology on enhancing the heat transfer rate within a double pipe heat exchanger by supplying the heat exchanger with water at different vortex strengths. A vortex generator with special inclined holes with different inlet angles was designed, manufactured, and integrated within the heat exchanger. In this study, four levels of Reynolds number for hot water in the annulus (Reh) were used, namely, 10,000; 14,500; 18,030; and 19,600. Similarly, four levels of Reynolds number for cold water in the inner tube (Rec) were used, namely, 12,000; 17,500; 22,500; and 29,000. As for the inlet flow angle (θ), four different levels were selected, namely, 0°, 30°, 45°, and 60°. The temperature along the heat exchanger was measured utilizing 34 thermocouples installed along the heat exchanger. It was found that increasing the inlet flow angle (θ) and/or the Reynolds number results in an increase in the local Nusselt number, the overall heat transfer coefficient, and the ratio of friction factor. It is revealed that the percentage increase in the average Nusselt number due to swirl flow compared to axial flow was 10%, 40%, and 82% for an inlet flow angle of 30°, 45°, and 60°, respectively.  相似文献   

11.
An experimental study has been conducted in dealing with natural convection heat transfer characteristics of microemulsion slurry in rectangular enclosures. The microemulsion slurry used in the present experiment was composed of water, surfactant, and fine particles of phase-change-material (PCM). The PCM mass concentration of the microemulsion slurry was varied from a maximum 30 mass% to a diluted minimum 5 mass%, and the experiments have been done separately in three subdivided temperature ranges of the dispersed PCM particles in a solid phase, two phases (coexistence of solid and liquid) and a liquid phase. The results showed that the Nusselt number increased slightly with the PCM mass concentration for the slurry in solid phase. In the phase change temperature range, the Nusselt number increased with an increase in PCM mass concentration of the slurry at low Rayleigh numbers, while it decreased with increasing PCM mass concentration of the slurry at high Rayleigh numbers. There was not much difference in natural heat transfer characteristics of the PCM slurry with low PCM concentrations (<10 mass%), however, the difference was getting greater with increasing the PCM concentration, especially for the enclosure at a lower aspect ratio (width/height of the rectangular enclosure). The enclosure height was varied from 5.5 to 24.6 mm under a fixed width and depth of 120 mm. Hence, the experiments were performed for a wide range of modified Rayleigh number from 3 × 102 to 1.0 × 107. The correlation generalized for the PCM slurry in a single phase was derived in the form of Nu=0.22(1−C1CmeC2AR)Ra1/(3n+1), where C1 and C2 were the optimum fitting constants obtained by the least square method. While the PCM was in a phase changing region, the correlation could be expressed as Nu=0.22(1−C1CmeC2AR)Ra1/(3n+1)Ste−0.25, where the Ste was the modified Stefan number.  相似文献   

12.
The phase change and heat transfer characteristics of a eutectic mixture of palmitic and stearic acids as phase change material (PCM) during the melting and solidification processes were determined experimentally in a vertical two concentric pipes energy storage system. This study deals with three important subjects. First is determination of the eutectic composition ratio of the palmitic acid (PA) and stearic acid (SA) binary system and measurement of its thermophysical properties by differential scanning calorimetry (DSC). Second is establishment of the phase transition characteristics of the mixture, such as the total melting and solidification temperatures and times, the heat transfer modes in the melted and solidified PCM and the effect of Reynolds and Stefan numbers as initial heat transfer fluid (HTF) conditions on the phase transition behaviors. Third is calculation of the heat transfer coefficients between the outside wall of the HTF pipe and the PCM, the heat recovery rates and heat fractions during the phase change processes of the mixture and also discussion of the effect of the inlet HTF parameters on these characteristics. The DSC results showed that the PA–SA binary system in the mixture ratio of 64.2:35.8 wt% forms a eutectic, which melts at 52.3 °C and has a latent heat of 181.7 J g−1, and thus, these properties make it a suitable PCM for passive solar space heating and domestic water heating applications with respect to climate conditions. The experimental results also indicated that the eutectic mixture of PA–SA encapsulated in the annulus of concentric double pipes has good phase change and heat transfer characteristics during the melting and solidification processes, and it is an attractive candidate as a potential PCM for heat storage in latent heat thermal energy storage systems.  相似文献   

13.
A latent heat thermal energy storage system using a phase change material (PCM) is an efficient way of storing or releasing a large amount of heat during melting or solidification. It has been determined that the shell‐and‐tube type heat exchanger is the most promising device as a latent heat system that requires high efficiency for a minimum volume. In this type of heat exchanger, the PCM fills the annular shell space around the finned tube while the heat transfer fluid flows within the tube. One of the methods used for increasing the rate of energy storage is to increase the heat transfer surface area by employing finned surfaces. In this study, energy storage by phase change around a radially finned tube is investigated numerically and experimentally. The solution of the system consists of the solving governing equations for the heat transfer fluid (HTF), pipe wall and phase change material. Numerical simulations are performed to investigate the effect of several fin parameters (fin spacing and fin diameter) and flow parameter (Re number and inlet temperature of HTF) and compare with experimental results. The effect of each variable on energy storage and amount of solidification are presented graphically. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
The charge/discharge rate of a spherical phase change material (PCM) capsule was assessed in consideration of phase change phenomenon and the combined effect of thermal radiation and heat convection in the charging/discharging processes. The heat transfer model was developed based on a single PCM capsule. The equivalent heat flux was evaluated by using the thermal resistance method. In consideration of the thermal radiation, the equivalent charge/discharge rate was improved, and the temperature rising of the PCM was actually much faster in the charging/discharging processes. It was indicated that the influence of the thermal radiation became more significant for PCM capsules under a small Re number (constant air velocity) and for high‐grade thermal energy storage. The analytical results showed that the highest heat flux contributed by cold thermal radiation occupied 30% and 62% of that by heat convection for PCM capsules with radius of 10 and 40 mm, respectively. This illustrated the crucial value of thermal radiation on the charge/discharge rate of PCM capsules with a large radius. However, for smaller size PCM capsules, the equivalent heat flux was larger under the same fluid flow velocity, and it decreased more promptly with time, because the heat convection that played the dominant role in charge/discharge processes was sensitively affected by the radius of the PCM capsules. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
The present paper describes the analysis of the melting process in a single vertical shell‐and‐tube latent heat thermal energy storage (LHTES), unit and it is directed at understanding the thermal performance of the system. The study is realized using a computational fluid‐dynamic (CFD) model that takes into account of the phase‐change phenomenon by means of the enthalpy method. Fluid flow is fully resolved in the liquid phase‐change material (PCM) in order to elucidate the role of natural convection. The unsteady evolution of the melting front and the velocity and temperature fields is detailed. Temperature profiles are analyzed and compared with experimental data available in the literature. Other relevant quantities are also monitored, including energy stored and heat flux exchanged between PCM and HTF. The results demonstrate that natural convection within PCM and inlet HTF temperature significantly affects the phase‐change process. Thermal enhancement through the dispersion of highly conductive nanoparticles in the base PCM is considered in the second part of the paper. Thermal behavior of the LHTES unit charged with nano‐enhanced PCM is numerically analyzed and compared with the original system configuration. Due to increase of thermal conductivity, augmented thermal performance is observed: melting time is reduced of 15% when nano‐enhanced PCM with particle volume fraction of 4% is adopted. Similar improvements of the heat transfer rate are also detected. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
The present numerical analyses are related to the cooling of a hybrid electric vehicle (HEV) battery module by water–ethanol mixture. The fluid is passed through a cold plate consisting of two rectangular channels of 0.01 m depth, 0.015 m width, and 0.15 m length. The battery module is represented by a heater placed below the cold plate. The single‐phase pressure drop and single‐phase heat transfer coefficient for water, water–ethanol mixture of mass fraction of 25%, 50%, and 75%, and ethanol are determined numerically for different heat fluxes of 10, 15, 20, and 25 kW/m2 and different Reynolds numbers 500, 1000, 1500, 2000, and 2500. To solve the Navier–Stokes equation, the pressure correction method was used and to solve the energy equation, the Lax–Wendroff explicit method is used. Numerical results obtained for water are compared with the literature correlations. The friction factor for water deviated by an average of 8.02% from the Lewis and Robertson equation. The Nusselt number for water deviated by 7.35% from the Churchill and Ozoe equation at lower Reynolds number 500 and at higher Reynolds number 2500, Nusselt number deviated by 13.68% from the Stephan equation. The results showed that the heat transfer coefficient increased with an increase in Reynolds number and heat flux. The effect of the increase in Reynolds number is more significant than the increase in heat flux. At higher ethanol mass fraction and higher Reynolds number the heat transfer coefficient increased with heat flux when compared to water. There is no significant decrease in heat transfer coefficient with an increase in ethanol mass fraction. The pressure drop increased and the heat transfer coefficient decreased with an increase in ethanol mass fraction.  相似文献   

17.
Corrugated plate heat exchangers have larger heat transfer surface area and increased turbulence level due to the corrugations. In this study, experimental heat transfer data are obtained for single phase flow (water-to-water) configurations in a commercial plate heat exchanger for symmetric 30°/30°, 60°/60°, and mixed 30°/60° chevron angle plates. Experiments were carried out for Reynolds number ranging from 500 to 2500 and Prandtl number from 3.5 to 6.5. Experimental results show significant effect of chevron angle and Reynolds number on the heat transfer coefficient. Based on the experimental data, a correlation to estimate Nusselt number as a function of Reynolds number, Prandtl number and chevron angle has been proposed.  相似文献   

18.
Lauric acid (m.p.: 42.6°C) and myristic acid (m.p.: 52.2°C) are phase change materials (PCM) having quite high melting points which can limit their use in low‐temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of lauric acid (LA) and myristic acid (MA). In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 66.0 wt% LA forms a eutectic mixture having melting temperature of 34.2°C and the latent heat of fusion of 166.8 J g?1. This study also considers the experimental establishment of thermal characteristics of the eutectic PCM in a vertical concentric pipe‐in‐pipe heat storage system. Thermal performance of the PCM was evaluated with respect to the effect of inlet temperature and mass flow rate of the heat transfer fluid on those characteristics during the heat charging and discharging processes. The DSC thermal analysis and the experimental results indicate that the LA–MA eutectic PCM can be potential material for low‐temperature solar energy storage applications in terms of its thermo‐physical and thermal characteristics. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
Heat transfer between two immiscible liquid phases in turbulent flow is of great interest in improving the residence time, compactness, and energy cost of cooling and heating processes. The high-efficiency vortex (HEV) device used here as a direct-contact heat exchanger (DCHE) is a generic multifunctional exchanger/reactor in which wall tabs generate longitudinal vortices responsible for convective radial transfer that enhance macro-mixing, phase dispersion and fast temperature homogenization in the flow.The experiments reported here concern a continuous flow of water in which an immiscible mineral oil is injected. The inlet water temperature ranges from 11 to 13 °C, and the inlet oil temperature from 40 to 48 °C; the flow Reynolds number varies between 7500 and 15 000. An algebraic one-dimensional thermal model accounting for the axial evolution of the phase temperatures coupled with drop breakup is developed and validated by the experimental thermal results in the DCHE. This model requires knowledge of the turbulent field in single-phase conditions; it can be adapted to other flow geometries and can be used as a sizing tool for engineering design.Despite the phase separation at the outlet, the DCHE is more efficient than a double-jacketed heat exchanger in terms of global Nusselt number. In addition, the HEV heat exchanger is energetically less costly than the other DCHE for the same heat-transfer capacity.  相似文献   

20.
An experimental study was conducted to investigate the melting process of a phase change material (PCM) and the associated convection heat transfer due to a U‐shaped heat source embedded in the PCM. The experiments were conducted at four input heat fluxes that varied from 3450 to 5840 W/m2. The results showed that the heat transfer behavior, interface movement, and the heat transfer coefficients differed both axially and vertically inside the chamber. The local convective heat transfer coefficient in the inner region, enclosed by the U‐tube, was found to be about 35% higher than that in the outer region over the input heat flux range, resulting in faster melting in the inner region than in the outer region. As melted domain grew vertically from 15% to 100%, it was observed that the overall h in the inner region increased by 40–55% from the lowest to highest heat flux. The melting rate was also found comparatively high up until 65–70% of the total PCM volume melted because of the higher contribution from the inner region. It was also observed that the Rayleigh number increased by approximately 23% in the inner region and 18% in the whole domain as the heat flux increased from 3450 to 5840 W/m2. A new Nusselt–Rayleigh number correlation is proposed for the heat transfer during the melting process due to a U‐shaped heat source. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号