首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
软X射线双频光栅设计及制作   总被引:1,自引:0,他引:1  
以软X射线双频光栅作为剪切干涉元件,研究了剪切干涉法在激光等离子体诊断实验中的应用.为提高实验成功率,研究了双频光栅栅线的平行度及光栅效率.根据软X射线双频光栅栅线平行度与剪切干涉系统的干涉图像的关系,理论计算得出光栅平行度的指标要求.在全息曝光工艺中,通过衍射光斑位置检测法和莫尔条纹法确认光栅平行性,保证光栅平行度达到0.01°.利用合肥国家同步辐射实验室计量站对双频光栅的两组-1级衍射效率进行测试.测试结果显示,光栅平行性满足系统要求,光栅的两组-1级衍射效率均达到10%.软X射线双频光栅剪切干涉实验结果表明,双频光栅平行度及衍射效率满足激光等离子体诊断实验需求.  相似文献   

2.
Three‐dimensional (3D) printing technology has the advantage of enabling specific visualization of creative ideas. Since synchrotron based images can provide high sensitivity and high resolution, they are a very useful technology to identify the 3D anatomy of microscale samples. X‐ray images using such synchrotron radiation are grafted to 3D printing technology. We can be obtained 3D images and modeling data of an ant using synchrotron radiation, and then, it were outputted with the 3D printer. A new way to identify the usefulness of the structure analysis is then found by visualizing the micro‐internal structure of diverse biomedical samples and creating an enlarged model. This study suggests methods of utilizing a 3D printed model produced through synchrotron radiation imaging in various fields such as bioengineering, medical, and education.  相似文献   

3.
Radiation beam interface contrast X‐ray microscopy provides resolution of a few dozen nanometers from fixed whole muscle biopsies, allowing better reconstruction of the microstructure of the muscle than is currently possible with classic histological techniques. Fixed soleus muscle biopsies have been evaluated from the walk‐in mouse model using phase‐contrast X‐ray microscopy, and results presented that corroborate the accuracy of the method used, and its potential for application in physiotherapy and occupational therapy studies. We believe that this method will enhance existing morphometric methods of analysis, leading to accurate reconstruction of other thick specimens that would otherwise require thin sectioning and reconstruction through deconvolution algorithms.  相似文献   

4.
This paper concerns an important aspect of current developments in medical and biological imaging: the possibility for imaging soft tissue at relatively high resolution in the micrometer range or better, without tedious and/or entirely destructive sample preparation. Structures with low absorption contrast have been visualized using in-line phase contrast imaging. The experiments have been performed at the Advanced Photon Source, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high photon flux (>10(14) photons/s) at high photon energies (5-70 keV). Thick gerbil cochlear slices have been imaged and were compared with those obtained by light microscopy. Furthermore, intact gerbil cochleae have been imaged to identify the soft tissue structures involved in the hearing process. The present experimental approach was essential for visualizing the inner ear structures involved in the hearing process in an intact cochlea.  相似文献   

5.
High resolution X‐ray computed tomography (CT), or microCT, is a promising and already widely used technique in various scientific fields. Also for histological purposes it has great potential. Although microCT has proven to be a valuable technique for the imaging of bone structures, the visualization of soft tissue structures is still an important challenge due to their low inherent X‐ray contrast. One way to achieve contrast enhancement is to make use of contrast agents. However, contrary to light and electron microscopy, knowledge about contrast agents and staining procedures is limited for X‐ray CT. The purpose of this paper is to identify useful X‐ray contrast agents for soft tissue visualization, which can be applied in a simple way and are also suited for samples larger than (1 cm)3. And 28 chemical substances have been investigated. All chemicals were applied in the form of concentrated aqueous solutions in which the samples were immersed. First, strips of green Bacon were stained to evaluate contrast enhancement between muscle and adipose tissue. Furthermore it was also tested whether the contrast agents remained fixed in the tissue after staining by re‐immersing them in water. Based on the results, 12 contrast agents were selected for further testing on postmortem mice hind legs, containing a variety of different tissues, including muscle, fat, bone, cartilage and tendons. It was evaluated whether the contrast agents allowed a clearer distinction between the different soft tissue structures present. Finally also penetration depth was measured. And 26 chemicals resulted in contrast enhancement between muscle and adipose tissue in the Bacon strips. Mercury(II)chloride (HgCl2), phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and ammonium orthomolybdate ((NH4)2MoO4) remained fixed after re‐immersion in water. The penetration tests showed that potassium iodide (KI) and sodium tungstate can be most efficiently used for large samples of the order of several tens of cm3. PMA, PTA, HgCl2 and also to a lesser extent Na2WO4 and (NH4)2MoO4 allowed a clearer distinction between the different soft tissue structures present.  相似文献   

6.
Non‐invasive imaging techniques like X‐ray computed tomography have become very popular in zoology, as they allow for simultaneous imaging of the internal and external morphology of organisms. Nevertheless, the effect of different staining approaches required for this method on samples lacking mineralized tissues, such as soft‐bodied invertebrates, remains understudied. Herein, we used synchrotron radiation‐based X‐ray micro‐computed tomography to compare the effects of commonly used contrasting approaches on onychophorans – soft‐bodied invertebrates important for studying animal evolution. Representatives of Euperipatoides rowelli were stained with osmium tetroxide (vapour or solution), ruthenium red, phosphotungstic acid, or iodine. Unstained specimens were imaged using both standard attenuation‐based and differential phase‐contrast setups to simulate analyses with museum material. Our comparative qualitative analyses of several tissue types demonstrate that osmium tetroxide provides the best overall tissue contrast in onychophorans, whereas the remaining staining agents rather favour the visualisation of specific tissues and/or structures. Quantitative analyses using signal‐to‐noise ratio measurements show that the level of image noise may vary according to the staining agent and scanning medium selected. Furthermore, box‐and‐whisker plots revealed substantial overlap in grey values among structures in all datasets, suggesting that a combination of semiautomatic and manual segmentation of structures is required for comprehensive 3D reconstructions of Onychophora, irrespective of the approach selected. Our results show that X‐ray micro‐computed tomography is a promising technique for studying onychophorans and, despite the benefits and disadvantages of different staining agents for specific tissues/structures, this method retrieves informative data that may eventually help address evolutionary questions long associated with Onychophora.  相似文献   

7.
Several dedicated commercial lab‐based micro‐computed tomography (μCT) systems exist, which provide high‐resolution images of samples, with the capability to also deliver in‐line phase contrast. X‐ray phase contrast is particularly beneficial when visualizing very small features and weakly absorbing samples. The raw measured projections will include both phase and absorption effects. Extending our previous work that addressed the optimization of experimental conditions at the commercial ZEISS Xradia 500 Versa system, single‐distance phase‐contrast imaging is demonstrated on complex biological and material samples. From data captured at this system, we demonstrate extraction of the phase signal or the correction of the mixed image for the phase shift, and show how this procedure increases the contrast and removes artefacts. These high‐quality images, measured without the use of a synchrotron X‐ray source, demonstrate that highly sensitive, micrometre‐resolution imaging of 3D volumes is widely accessible using commercially advanced laboratory devices.  相似文献   

8.
In this study, we compare two evolving techniques for obtaining high‐resolution 3D anatomical data of a mouse specimen. On the one hand, we investigate cryotome‐based planar epi‐illumination imaging (cryo‐imaging). On the other hand, we examine X‐ray phase‐contrast micro‐computed tomography (micro‐CT) using synchrotron radiation. Cryo‐imaging is a technique in which an electron multiplying charge coupled camera takes images of a cryo‐frozen specimen during the sectioning process. Subsequent image alignment and virtual stacking result in volumetric data. X‐ray phase‐contrast imaging is based on the minute refraction of X‐rays inside the specimen and features higher soft‐tissue contrast than conventional, attenuation‐based micro‐CT. To explore the potential of both techniques for studying whole mouse disease models, one mouse specimen was imaged using both techniques. Obtained data are compared visually and quantitatively, specifically with regard to the visibility of fine anatomical details. Internal structure of the mouse specimen is visible in great detail with both techniques and the study shows in particular that soft‐tissue contrast is strongly enhanced in the X‐ray phase images compared to the attenuation‐based images. This identifies phase‐contrast micro‐CT as a powerful tool for the study of small animal disease models.  相似文献   

9.
Using two levels of electron beam lithography, vapor phase deposition techniques, and FIB etching, we have fabricated an electrostatic Boersch phase plate for contrast enhancement of weak phase objects in a transmission electron microscope. The phase plate has suitable dimensions for the imaging of small biological samples without compromising the high-resolution capabilities of the microscope. A micro-structured electrode allows for phase tuning of the unscattered electron beam, which enables the recording of contrast enhanced in-focus images and in-line holograms. We have demonstrated experimentally that our phase plate improves the contrast of carbon nanotubes while maintaining high-resolution imaging performance, which is demonstrated for the case of an AlGaAs heterostructure. The development opens a new way to study interfaces between soft and hard materials.  相似文献   

10.
A thorough understanding of inner ear anatomy is important for investigators. However, investigation of the mouse inner ear is difficult due to the limitations of imaging techniques. X‐ray phase contrast tomography increases contrast 100–1,000 times compared with conventional X‐ray imaging. This study aimed to investigate inner ear anatomy in a fresh post‐mortem mouse using X‐ray phase contrast tomography and to provide a comprehensive atlas of microstructures with less tissue deformation. All experiments were performed in accordance with our institution's guidelines on the care and use of laboratory animals. A fresh mouse cadaver was scanned immediately after sacrifice using an inline phase contrast tomography system. Slice images were reconstructed using a filtered back‐projection (FBP) algorithm. Standardized axial and coronal planes were adjusted with a multi‐planar reconstruction method. Some three‐dimensional (3D) objects were reconstructed by surface rendering. The characteristic features of microstructures, including otoconia masses of the saccular and utricular maculae, superior and inferior macula cribrosae, single canal, modiolus, and osseous spiral lamina, were described in detail. Spatial positions and relationships of the vestibular structures were exhibited in 3D views. This study investigated mouse inner ear anatomy and provided a standardized presentation of microstructures. In particular, otoconia masses were visualized in their natural status without contrast for the first time. The comprehensive anatomy atlas presented in this study provides an excellent reference for morphology studies of the inner ear.  相似文献   

11.
Iodine imparts strong contrast to objects imaged with electrons and X‐rays due to its high atomic number (53), and is widely used in liquid form as a microscopic stain and clinical contrast agent. We have developed a simple technique which exploits elemental iodine's sublimation‐deposition state‐change equilibrium to vapor stain specimens with iodine gas. Specimens are enclosed in a gas‐tight container along with a small mass of solid I2. The bottle is left at ambient laboratory conditions while staining proceeds until empirically determined completion (typically days to weeks). We demonstrate the utility of iodine vapor staining by applying it to resin‐embedded tissue blocks and whole locusts and imaging them with backscattered electron scanning electron microscopy (BSE SEM) or X‐ray microtomography (XMT). Contrast is comparable to that achieved with liquid staining but without the consequent tissue shrinkage, stain pooling, or uneven coverage artefacts associated with immersing the specimen in iodine solutions. Unmineralized tissue histology can be read in BSE SEM images with good discrimination between tissue components. Organs within the locust head are readily distinguished in XMT images with particularly useful contrast in the chitin exoskeleton, muscle and nerves. Here, we have used iodine vapor staining for two imaging modalities in frequent use in our laboratories and on the specimen types with which we work. It is likely to be equally convenient for a wide range of specimens, and for other modalities which generate contrast from electron‐ and photon‐sample interactions, such as transmission electron microscopy and light microscopy. Microsc. Res. Tech. 77:1044–1051, 2014. © 2014 The Authors. Microscopy Research Technique published by Wiley Periodocals, Inc.  相似文献   

12.
In this study, we visualized the internal structures of various bio-samples and found the optimum conditions of test samples for the 7 keV hard X-ray microscope of the Pohang light source. From the captured X-ray images, we could observe the intercellular and intracellular structures of dehydrated human cells and mouse tumor tissues without using any staining materials in a spatial resolution better than 100 nm. The metastasized lung tissue, which was several tens of micrometers in thickness, was found to be very well suited to this hard X-ray microscope system, because it is nearly impossible to observe such a nontransparent and thick sample with a high spatial resolution better than 100 nm using any microscopes such as a soft X-ray microscope, an optical microscope, or an electron microscope.  相似文献   

13.
For the histological analysis of hard tissue such as bone, various acrylate‐based materials have been used as an embedding medium. However, commercial embedding media are expensive, and cutting the embedded block takes a long time. In this study, mixtures of methyl methacrylate (MMA), di‐butyl‐phthalate (DBP), and oleic acid (OA) were tested for possible application as an embedding medium for large and small undecalcified bone specimens. Mechanical properties were tested in a compressive mode. We investigated the change of hydrophilicity in the sectioned surface by measuring the contact angle depending on the OA. Crystallinity was analyzed using a X‐ray diffractometer (XRD). Surface analysis was performed using a confocal laser scanning microscope. To determine the staining efficiency of staining dyes, hamatoxylin‐eosin (H&E) and Masson's trichrome (MT) staining methods were performed for the histological analysis of bone‐implant complex. We confirmed that the investigated embedding media showed good properties such as optimal mechanical strength appropriate for cutting the embedded block and proper staining efficiency for histological analysis. Therefore, the MMA/DBP/OA mixtures can be used as an embedding media appropriate for various hard tissues and bone‐implant complex. Microsc. Res. Tech. 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

14.
Muscle damage can reduces the biological functions and lead to ultimately a disease state. For the reason, it is important to accurately check the state of an injury such as atrophy, and it is required to identify the state of fibers constituting the muscle. This study describes a novel method of analyzing single muscle fibers with injury conditions in three‐dimensions. The muscle fibers of the mice were visualized using phase‐contrast X‐ray projection the microstructure. In additions, it was possible to confirm the status by quantitatively analyzing the injury severity of muscle fibers. Significantly, the muscle conditions of multiple individuals were individually determined. This study could contributes to areas where it is very important to identify microdetailed and quantitative changes of state, such as new drug development.  相似文献   

15.
High‐resolution images of the cochlea are used to develop atlases to extract anatomical features from low‐resolution clinical computed tomography (CT) images. We compare visualization and contrast of conventional absorption‐based micro‐CT to synchrotron radiation phase contrast imaging (SR‐PCI) images of whole unstained, nondecalcified human cochleae. Three cadaveric cochleae were imaged using SR‐PCI and micro‐CT. Images were visually compared and contrast‐to‐noise ratios (CNRs) were computed from n = 27 regions‐of‐interest (enclosing soft tissue) for quantitative comparisons. Three‐dimensional (3D) models of cochlear internal structures were constructed from SR‐PCI images using a semiautomatic segmentation method. SR‐PCI images provided superior visualization of soft tissue microstructures over conventional micro‐CT images. CNR improved from 7.5 ± 2.5 in micro‐CT images to 18.0 ± 4.3 in SR‐PCI images (p < 0.0001). The semiautomatic segmentations yielded accurate reconstructions of 3D models of the intracochlear anatomy. The improved visualization, contrast and modelling achieved using SR‐PCI images are very promising for developing atlas‐based segmentation methods for postoperative evaluation of cochlear implant surgery.  相似文献   

16.
We present in this study results from X‐ray tomographic microscopy with synchrotron radiation performed both in attenuation and phase contrast modes on a limestone sample during two stages of water drying. No contrast agent was used in order to increase the X‐ray attenuation by water. We show that only by using the phase contrast mode it is possible to achieve enough water content change resolution to investigate the drying process at the pore‐scale. We performed 3D image analysis of the time‐differential phase contrast tomogram. We show by the results of such analysis that it is possible to obtain a reliable characterization of the spatial redistribution of water in the resolved pore system in agreement with what expected from the theory of drying in porous media and from measurements performed with other approaches. We thus show the potential of X‐ray phase contrast imaging for pore‐scale investigations of reactive water transport processes which cannot be imaged by adding a contrast agent for exploiting the standard attenuation contrast imaging mode.  相似文献   

17.
Vascularization is essential for many tissues and is a main requisite for various tissue‐engineering strategies. Different techniques are used for highlighting vasculature, in vivo and ex vivo, in 2‐D or 3‐D including histological staining, immunohistochemistry, radiography, angiography, microscopy, computed tomography (CT) or micro‐CT, both stand‐alone and synchrotron system. Vascularization can be studied with or without a contrast agent. This paper presents the results obtained with the latest Skyscan micro‐CT (Skyscan 1272, Bruker, Belgium) following barium sulphate injection replacing the bloodstream in comparison with results obtained with a Skyscan In Vivo 1076. Different hard and soft tissues were perfused with contrast agent and were harvested. Samples were analysed using both forms of micro‐CT, and improved results were shown using this new micro‐CT. This study highlights the vasculature using micro‐CT methods. The results obtained with the Skyscan 1272 are clearly defined compared to results obtained with Skyscan 1076. In particular, this instrument highlights the high number of small vessels, which were not seen before at lower resolution. This new micro‐CT opens broader possibilities in detection and characterization of the 3‐D vascular tree to assess vascular tissue engineering strategies.  相似文献   

18.
X‐ray computed tomography is a strong tool that finds many applications both in medical applications and in the investigation of biological and nonbiological samples. In the clinics, X‐ray tomography is widely used for diagnostic purposes whose three‐dimensional imaging in high resolution helps physicians to obtain detailed image of investigated regions. Researchers in biological sciences and engineering use X‐ray tomography because it is a nondestructive method to assess the structure of their samples. In both medical and biological applications, visualization of soft tissues and structures requires special treatment, in which special contrast agents are used. In this detailed report, molecule‐based and nanoparticle‐based contrast agents used in biological applications to enhance the image quality were compiled and reported. Special contrast agent applications and protocols to enhance the contrast for the biological applications and works to develop nanoparticle contrast agents to enhance the contrast for targeted drug delivery and general imaging applications were also assessed and listed.  相似文献   

19.
A novel differential interference contrast microscope (DICM) is proposed in this research. It is constituted by inserting a Savart shear prism between the objective and sample of a polarising microscope having a rotatable analyser as the phase‐shifter, and it is with the ability to enhance image contrast using the principle of shearing interferometry. This letter is to introduce the configuration, interpret the interference patterns and present the experimental setup of the DICM. In addition, this letter is to display the experimental results from the uses of the setup; the results demonstrate the validity and ability of the DICM.  相似文献   

20.
Soft X‐ray microscopy has excellent characteristics for imaging cells and subcellular structures. In this paper, the yeast strain, Candida utilis, was imaged by soft X‐ray microscopy and three‐dimensional volumes were reconstructed with the SART‐TV method. We performed segmentation on the reconstruction in three dimensions and identified several types of subcellular architecture within the specimen cells based on their linear absorption coefficient (LAC) values. Organelles can be identified by the correlation between the soft X‐ray LAC values and the subcellular architectures. Quantitative analyses of the volume ratio of organelles to whole cell in different phases were also carried out according to the three‐dimensional datasets. With such excellent features, soft X‐ray imaging has a great influence in the field of biological cellular and subcellular research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号