首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Label-free electrochemical detection for aptamer-based array electrodes   总被引:9,自引:0,他引:9  
Xu D  Xu D  Yu X  Liu Z  He W  Ma Z 《Analytical chemistry》2005,77(16):5107-5113
An electrochemical impedance spectroscopy method of detection for aptamer-based array electrodes is reported in which the binding of aptamers immobilized on gold electrodes leads to impedance changes associated with target protein binding events. Human IgE was used as a model target protein and incubated with the aptamer-based array consisting of single-stranded DNA containing a hairpin loop. To increase the binding efficiency for proteins, a hybrid modified layer containing aptamers and cysteamine was fabricated on the photolithographic gold surface through molecular self-assembly. Atomic force microscopy analysis demonstrated that human IgE could be specifically captured by the aptamer and stand well above the self-assembled monolayer (SAM) surface. Compared to immunosensing methods using anti-human IgE antibody as the recognition element, impedance spectroscopy detection could provide higher sensitivity and better selectivity for aptamer-modified electrodes. The results of this method show good correlation for human IgE in the range of 2.5-100 nM. A detection limit of 0.1 nM (5 fmol in a 50-microL sample) was obtained, and an average of the relative standard deviation was <10%. The method herein describes the first label-free detection for arrayed electrodes utilizing electrochemical impedance spectroscopy.  相似文献   

2.
Aptamer-based assays represent a modern and attractive approach in bioanalytical chemistry. The DNA thrombin aptamer has been extensively investigated, and the coupling of this aptamer to different transduction principles has demonstrated the wide applicability of aptamers as bioreceptors in bioanalytical assays. The goal of this work was to critically evaluate all the parameters that can influence the sensor performances by using the thrombin aptamer immobilized onto piezoelectric quartz crystals. The optimization of the immobilization and the binding protocol was of paramount importance, and improvements in analytical performances could be obtained by optimizing simple steps in immobilization and assay conditions. Moreover, the work demonstrated the possibility of using aptamer-based sensors in complex matrixes, opening the possibility of a real application to diagnostics or medical investigation.  相似文献   

3.
Sensors--an effective approach for the detection of explosives   总被引:4,自引:0,他引:4  
The detection of explosives and explosive related illicit materials is an important area for preventing terrorist activities and for putting a check on their deleterious effects on health. A number of different methods, based on different principles, have been developed in the past for the detection of explosives. Sensors are one of those methods of detection which have capability to mimic the canine system and which are known to be the most reliable method of detection. The objective of this review is to provide comprehensive knowledge and information on the sensors operating on different transduction principles, ranging from electrochemical to immunosensors, being used for the detection of explosives as they pose a threat for both health and security of the nation. The review focuses mainly on the sensors developed in the recent 5 years and is prepared through summary of literature available on the subject.  相似文献   

4.
The objective of this paper is to provide a comprehensive review of explosive detection by chemiluminescence (CL) through a summary of the relevant literature in the last 5 years and a synopsis of current research topics and developments. The literature reviewed is specially addressed for the detection of a group of high explosives, containing nitrogen compounds. Most explosives compounds contain either nitro or nitrate groups which make possible their detection and quantification using detection systems based on chemiluminescent reactions. Practical considerations and experimental requirements are indicated, and the possibilities and limitations are evaluated.  相似文献   

5.
We report label-free protein detection using a microfabricated cantilever-based sensor that is functionalized with DNA aptamers to act as receptor molecules. The sensor utilizes two adjacent cantilevers that constitute a sensor/reference pair and allows direct detection of the differential bending between the two cantilevers. One cantilever is functionalized with aptamers selected for Taq DNA polymerase while the other is blocked with single-stranded DNA. We have found that the polymerase-aptamer binding induces a change in surface stress, which causes a differential cantilever bending that ranges from 3 to 32 nm depending on the ligand concentration. Protein recognition on the sensor surface is specific and has a concentration dependence that is similar to that in solution.  相似文献   

6.
This paper presents a new signal transduction method, called label-acquired magnetorotation (LAM), for the measurement of the concentration of proteins in solution. We demonstrate the use of LAM to detect the protein thrombin using aptamers, with a limit of detection of 300 pM. LAM is modeled after a sandwich assay, with a 10 μm nonmagnetic "mother" sphere as the capture component and with 1 μm magnetic "daughter" beads as the labels. The protein-mediated attachment of daughter beads to the mother sphere forms a rotating sandwich complex. In a rotating magnetic field, the rotational frequency of a sandwich complex scales with the number of attached magnetic beads, which scales with the concentration of the protein present in solution. This paper represents the first instance of the detection of a protein using LAM.  相似文献   

7.
Highly sensitive detection of proteins is essential to biomedical research as well as clinical diagnosis. However, so far most detection methods rely on antibody-based assays and are usually laborious and time-consuming with poor sensitivity. Here, we develop a simple and sensitive method for the detection of a biomarker protein, platelet-derived growth factor BB (PDGF-BB), based on aptamer-based target-triggering two-stage amplification. With the involvement of an aptamer-based probe and an exponential amplification reaction (EXPAR) template, our method combines strand displacement amplification (SDA) and EXPAR, transforming the probe conformational change induced by target binding into two-stage amplification and distinct fluorescence signal. This detection method exhibits excellent specificity and high sensitivity with a detection limit of 9.04 × 10(-13) M and a detection range of more than 5 orders of magnitude, which is comparable with or even superior to most currently used approaches for PDGF-BB detection. Moreover, this detection method has significant advantages of isothermal conditions required, simple and rapid without multiple separation and washing steps, low-cost without the need of any labeled DNA probes. Furthermore, this method might be extended to sensitive detection of a variety of biomolecules whose aptamers undergo similar conformational changes.  相似文献   

8.
We describe a new methodology for the trace detection of organic explosives containing nitro functionalities. Conventional gas chromatography separates the components of an explosive mixture. Effluent from the gas chromatograph is pyrolyzed by passage over a heated Nichrome wire. Nitric oxide produced on pyrolysis of a nitroorganic compound is then detected by ultraviolet absorption spectroscopy between 180 and 240 nm, using a deuterium lamp as the light source. Nitric oxide exhibits a sharply banded, characteristic spectrum in this region, enabling detection of nitroorganics. The system is tested using the explosive simulants nitrobenzene and 2,4-dinitrotoluene, and with the nitramine explosive tetryl. Detection limits are 25 ng for nitrobenzene and 50 ng for 2,4-dinitrotoluene. Tetryl is detected with a detection limit of 50 ng. The system is both easy to implement and could be built as a compact, low-power device.  相似文献   

9.
Wang XL  Li F  Su YH  Sun X  Li XB  Schluesener HJ  Tang F  Xu SQ 《Analytical chemistry》2004,76(19):5605-5610
Currently, methods for protein detection are not as sensitive and specific as methods for detection of specific nucleic acid sequences. Here, we present an analogous technique for detection of proteins using aptamers as ligands for target binding. We have named this method the aptamer-based exonuclease protection assay. We applied a special oligonucleotide probe containing a thrombin aptamer, which has the capacity to recognize thrombin with high affinity and specificity. The aptamer probe is a 22-base-long single-strand oligonucleotide with the thrombin aptamer sequence at the 3'-terminus and 7 additional nucleotides at the 5'-terminus, which is able to bind thrombin with high affinity and specificity. In the exonuclease protection assay, thrombin binds the aptamer and thereby protects it from degradation by exonuclease I, whereas any unbound aptamer probe is degraded by exonuclease I. Subsequently, the aptamer probes that were protected from exonuclease I by thrombin act as linkers to join two free connectors, which contain sequences matching the probe. The joined products, which reflect the identity and amount of the target protein, are amplified by PCR. The exonuclease protection assay is extremely sensitive, since it is based on PCR amplification. This method can detect as few as several hundred molecules of target protein without using washes or separations. In addition, this new method for protein detection is simple and inherits all the advantages of aptamers. The mechanism, moreover, may be generalized and used for other forms of protein analysis.  相似文献   

10.
Significant security threats posed by highly energetic nitroaromatic compounds in aquatic environments and the demilitarization and pending cleanup of areas previously used for munitions manufacture and storage represent a challenge for less expensive, faster, and more sensitive systems capable of analyzing groundwater and seawater samples for trace levels of explosive materials. Presented here is an inexpensive high throughput microfluidic immunosensor (HTMI) platform intended for the rapid, highly selective quantitation of nitroaromatic compounds in the field. Immunoaffinity and fluorescence detection schemes were implemented in tandem on a novel microfluidic device containing 39 parallel microchannels that were 500 μm tall, 250 μm wide, and 2.54 cm long with covalently tethered antibodies that was engineered for high-throughput high-volume sample processing. The devices were produced via a combination of high precision micromilling and hot embossing. Mass transfer limitations were found in conventional microsystems and were minimized due to higher surface area to volume ratios that exceeded those possessed by conventional microdevices and capillaries. Until now, these assays were limited to maximum total volume flow rates of ~1 mL/min due in part to kinetics and high head pressures of single microchannels. In the design demonstrated here, highly parallelized microchannels afforded up to a 100-fold increase in total volume flow rate while maintaining favorable kinetic constraints for efficient antigen-antibody interaction. The assay employed total volume throughput of up to 6 mL/min while yielding signal-to-noise ratios of >15 in all cases. In addition to samples being processed up to 60 times faster than in conventional displacement-based immunoassays, the current system was capable of quantitating 0.01 ng/mL TNT samples without implementing offline preconcentration, thereby, demonstrating the ability to improve sensitivity by as much as 2 orders of magnitude while decreasing total analysis times up to 60-fold.  相似文献   

11.
A new electrochemical methodology is reported for monitoring in homogeneous solution the enantiospecific binding of a small chiral analyte to an aptamer. The principle relies on the difference of diffusion rates between the targeted molecule and the aptamer/target complex, and thus on the ability to more easily electrochemically detect the former over the latter in a homogeneous solution. This electrochemical detection strategy is significant because, in contrast to the common laborious and time-consuming heterogeneous binding approaches, it is based on a simple and fast homogeneous binding assay which does not call for an aptamer conformational change upon ligand binding. The methodology is here exemplified with the specific chiral recognition of trace amounts of l- or d-tyrosinamide by a 49-mer d- or l-deoxyribooligonucleotide receptor. Detection as low as 0.1% of the minor enantiomer in a nonracemic mixture can be achieved in a very short analysis time (<1 min). The assay finally combines numerous attractive features including simplicity, rapidity, low cost, flexibility, low volume samples (few microliters), and homogeneous format.  相似文献   

12.
A novel electrochemical technique for the general assay of lipase activity is described. The method utilizes a solid-supported lipase substrate, which is formed by dripping and drying a small amount of an ethanol solution of 9-(5'-ferrocenylpentanoyloxy)nonyl disulfide (FPONDS) onto gold modified by a hexanethiol self-assembled monolayer. The redox ferrocene group of FPONDS generates the electrochemical signal, the intensity of which is proportional to the number of FPONDS molecules at the interface. Electrochemical and surface-enhanced infrared absorption spectroscopic data, as well as control experiments with an engineered, deactivated mutant enzyme, demonstrate that the wild-type lipase from Thermomyces lanuginosus is capable of cleaving the ester bonds of FPONDS molecules via an enzymatic hydrolysis mechanism, which includes the adsorption of the lipase onto the substrate surface. The hydrolysis liberates the ferrocene groups from the interface triggering a decay of the electrochemical redox signal. The rate of the electrochemical signal decrease is proportional to the lipase activity/concentration. These data suggest a general method for the direct measure of enzymatic activity of lipases.  相似文献   

13.
Ion mobility spectrometry (IMS) has become the most widely used technology for trace explosives detection. A key task in designing IMS systems is to balance the explosives detection performance with size, weight, cost, and safety of the instrument. Commercial instruments are, by and large, equipped with radioactive (63)Ni ionization sources which pose inherent problems for transportation, safety, and waste disposal regulation. An alternative to a radioactive source is a corona discharge ionization source, which offers the benefits of simplicity, stability, and sensitivity without the regulatory problems. An IMS system was designed and built based on modeling and simulation with the goal to achieve a lightweight modular design that offered high performance for the detection of trace explosives using a corona ionization source. Modeling and simulations were used to investigate design alternatives and optimize parameters. Simulated spectra were obtained for 2,4,6-trinitrotoluene (TNT) and cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) and showed good agreement with experimentally measured spectra using a corona ionization source. The reduced mobilities for TNT and RDX obtained with corona ionization were 1.53 and 1.46 cm(2)/(V s), respectively, and this agreed well with literature values.  相似文献   

14.
A commercialized thermal neutron analysis (TNA) sensor has been developed to confirm the presence of buried bulk explosives as part of a multi-sensor anti-tank landmine detection system. Continuing improvements to the TNA system have included the use of an electronic pulsed neutron generator that offers the possibility of applying fast neutron analysis (FNA) methods to improve the system's detection capability. This paper describes an investigation into the use of FNA as a complementary component in such a TNA system. The results of a modeling study using simple geometries and a full model of the TNA sensor head are presented, as well as preliminary results from an experimental associated particle imaging (API) system that supports the modeling study results. The investigation has concluded that the pulsed beam FNA approach would not improve the detection performance of a TNA system for landmine or buried IED detection in a confirmation role, and could not be made into a practical stand-alone detection system for buried anti-tank landmines. Detection of buried landmines and IEDs by FNA remains a possibility, however, through the use of the API technique.  相似文献   

15.
A novel approach based on fluorescence quenching is presented for the analysis of nitrated explosives. Seventeen common explosives and their degradation products are shown to be potent quenchers of pyrene, having Stern-Volmer constants that generally increase with the degree of nitration. Aromatic explosives such as 2,4,6-trinitrotoluene (2,4,6-TNT) are more effective quenchers than aliphatic or nitramine explosives. In addition, nitroaromatic explosives are found to have unique interactions with pyrene that lead to a wavelength dependence of their Stern-Volmer constants. This phenomenon allows for their differentiation from other nitrated explosives. The fluorescence quenching method is then applied to the determination of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine(HMX), 2,4,6-TNT, nitromethane, and ammonium nitrate in various commercial explosive samples. The samples are separated by capillary liquid chromatography with post-column addition of the pyrene solution and detection by laser-induced fluorescence. The indirect fluorescence quenching method shows increased sensitivity and selectivity over traditional UV-visible absorbance as well as the ability to detect a wider range of organic and inorganic nitrated compounds.  相似文献   

16.
A novel electrochemical immunosensing strategy for the detection of atrazine based on magnetic beads is presented. Different coupling strategies for the modification of the magnetic beads with the specific anti-atrazine antibody have been developed. The immunological reaction for the detection of atrazine performed on the magnetic bead is based on a direct competitive assay using a peroxidase (HRP) tracer as the enzymatic label. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magnetosensor made of graphite-epoxy composite, which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate and mediator for the enzyme HRP. The electrochemical approach is also compared with a novel magneto-ELISA based on optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked real orange juice samples. The detection limit for atrazine using the competitive electrochemical magnetoimmunosensing strategy with anti-atrazine-specific antibody covalent coupled with tosyl-activated magnetic beads was found to be 6 x 10(-3) microg L(-1) (0.027 nmol L(-1)). This strategy offers great promise for rapid, simple, cost-effective, and on-site analysis of biological, food, and environmental samples.  相似文献   

17.
高晓进 《声学技术》2019,38(5):526-531
新型机翼、弹翼等结构已采用金属夹心碳纤维增强(Carbon Fiber Reinfored Polymer,CFPR)复合材料结构。针对该类复合材料结构的材料组成和结构特点,分析和对比常用的超声穿透法和超声反射法能否对金属夹心CFPR复合材料内部质量进行检测,提出了先采用超声C扫穿透法确定缺陷的平面位置,然后采用高分辨率超声A扫反射法确定复合材料中分层缺陷及采用超声相位法确定复合材料与金属间的脱粘缺陷的方法。采用提出的方法检测带有预置缺陷的试样和实际产品。检测结果表明,提出的方法可准确检测试样中大小为5 mm×5 mm的预置人工分层和脱粘,且能准确检测实际产品中的缺陷。  相似文献   

18.
A sequential injection analysis lab-on-valve (SIA-LOV) system was developed for the specific detection of single-stranded nucleic acid sequences via sandwich hybridization of specific DNA probes to the target sequence. One DNA probe was tagged with fluorescein; the other was biotinylated and immobilized to streptavidin-coated porous beads. The system was optimized with respect to buffer composition, length of hybridization and wash steps, and volumes and concentrations of components used. On-bead oligonucleotide hybridization was studied using UV detection at 260 nm, while a final dose response curve was quantified using fluorescence detection. A dynamic range of 1-1000 pmol was obtained for a synthetic DNA sequence that was homologous to a segment in the B. anthracis atxA mRNA. A within-day variation of 7.2% and a day-to-day variation of 9.9% was observed. Each analysis was completed within 20 min. Subsequently, the system was applied to the detection of atxA mRNA expressed in a surrogate organism and amplified using NASBA. The SIA-LOV will find its application in routine laboratory-based analysis of specific single-stranded DNA/RNA sequences. Future improvements will include the integration of dye-encapsulating liposomes for signal enhancement used in lieu of the single fluorophore-labeled probe in order to lower the limit of detection.  相似文献   

19.
A fluorescent polymer sensor array (FPSA) was made from commercially available fluorescent polymers coated onto glass beads and was tested to assess the ability of the array to discriminate between different analytes in aqueous solution. The array was challenged with exposures to 17 different analytes, including the explosives trinitrotoluene (TNT), tetryl, and RDX, various explosive-related compounds (ERCs), and nonexplosive electron-withdrawing compounds (EWCs). The array exhibited a natural selectivity toward EWCs, while the non-electron-withdrawing explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) produced no response. Response signatures were visualized by principal component analysis (PCA), and classified by linear discriminant analysis (LDA). RDX produced the same response signature as the sampled blanks and was classified accordingly. The array exhibited excellent discrimination toward all other compounds, with the exception of the isomers of nitrotoluene and aminodinitrotoluene. Of particular note was the ability of the array to discriminate between the three isomers of dinitrobenzene. The natural selectivity of the FPSA toward EWCs, plus the ability of the FPSA to discriminate between different EWCs, could be used to design a sensor with a low false alarm rate and an excellent ability to discriminate between explosives and explosive-related compounds.  相似文献   

20.
We present a Raman spectroscopic method for the noninvasive detection of liquid explosives within bottles, and other packaging, of substantially higher sensitivity and wider applicability than that currently available via conventional Raman spectroscopy. The approach uses a modification of the spatially offset Raman spectroscopy (SORS) concept, which permits the interrogation of a wide range of containers, including transparent, colored, and diffusely scattering plastic and glass beverage, medicine, and cosmetic bottles, with no change in experimental geometry. The enhanced sensitivity is achieved by the technique's inherent ability to effectively suppress fluorescence and Raman contributions originating from the wall of the container. The application is demonstrated on the noninvasive detection of hydrogen peroxide solution, a critical component of a number of liquid explosives. In contrast to conventional Raman spectroscopy, the modified SORS concept enables the detection of concealed hydrogen peroxide solution in all the studied cases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号