首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Experiments were conducted to investigate the behavior of the integrated system with biofilm reactors and zero-valent iron (ZVI) process for coking wastewater treatment. Particular attention was paid to the performance of the integrated system for removal of organic and inorganic nitrogen compounds. Maximal removal efficiencies of chemical oxygen demand (COD), ammonia nitrogen (NH(3)-N) and total inorganic nitrogen (TIN) were up to 96.1, 99.2 and 92.3%, respectively. Moreover, it was found that some phenolic compounds were effectively removed. The refractory organic compounds were primarily removed in ZVI process of the integrated system. These compounds, with molecular weights either ranged 10,000-30,000 Da or 0-2000 Da, were mainly the humic acid (HA) and hydrophilic (HyI) compounds. Oxidation-reduction and coagulation were the main removal mechanisms in ZVI process, which could enhance the biodegradability of the system effluent. Furthermore, the integrated system showed a rapid recovery performance against the sudden loading shock and remained high efficiencies for pollutants removal. Overall, the integrated system was proved feasible for coking wastewater treatment in practical applications.  相似文献   

2.
We studied the pretreatment of concentrated wastewater from triazine manufacturing by coagulation, electrolysis, and internal microelectrolysis. Results show that coagulation by polyaluminum chloride at dosage of 0.5 g/L could remove up to 17.2% chemical oxygen demand (COD) from the wastewater. Electrolysis using iron electrode achieved 33.2% COD removal at current of 2A in 180 min, which was attributed to coagulation and oxidation of the organic contaminants in the wastewater by the radicals (OH and O) and oxidants (O2, O3, and H2O2) produced in electrochemical reactions. Internal microelectrolysis using iron chips and granular activated carbon (GAC) showed that up to 60.5% COD could be removed under the conditions of iron/GAC/wastewater volumetric ratio of 3:2:490, sparge ratio (ratio of air flow rate to volume of wastewater) of 2:490 min(-1), and reaction time of 132 h. COD reduction in internal microelectrolysis was attributed to a combination of chemical and physical processes, mainly oxidation by radicals and oxidants formed in electrochemical reactions, adsorption on, co-precipitation with, and enmeshment in ferrous and ferric hydroxides resulted from Fe2+ released during anode oxidation. The results suggest that internal microelectrolysis using iron chips and GAC is a promising, low-cost alternative for pretreating concentrated wastewater from pesticide manufacturing.  相似文献   

3.
Treatment of groundwater polluted by arsenic compounds by zero valent iron   总被引:2,自引:0,他引:2  
Batch experiments were carried out to study the kinetics and efficiency of inorganic arsenic removal by zero valent iron (ZVI) powder, and as well as the effects of pH, anions, and humic material (HM) on this process. Moreover, column experiment was conducted for 31 days to treat arsenate solution of 500 microg As/L using waste iron chippings as filling. Batch experiments showed that both arsenate and arsenite compounds could be removed efficiently from simulated groundwater by ZVI under aerobic and relative anaerobic conditions. Aerobic condition was favorable to arsenic removal especially for arsenate, while arsenite could be removed more rapidly than arsenate in relative anaerobic condition. Oxidation of arsenite to arsenate by iron species in aerobic environment was observed, which is thought to be an important pathway of arsenite removal. In an unsealed system, the removal efficiency of both arsenate and arsenite decreased at higher pH value. In a sealed system, acidic and alkaline condition seemed to be favorable for arsenate and arsenite removal, respectively. Phosphate and low concentration sulfate caused a decrease in arsenate removal, while high concentration sulfate as well as nitrate caused slight increase in arsenate removal. Presence of HM in solution slightly inhibited arsenic removal. Arsenic removal efficiency in column study was influenced by flow rate and work period of the column. More than 98% of arsenate could be removed stably with a hydraulic resident time of 2 h at last, and the effluent meet the drinking water standard.  相似文献   

4.
This study investigated reductive transformation of iodine by zero-valent iron (ZVI), and the subsequent detoxification of iodine-laden wastewater. ZVI completely reduced aqueous iodine to non-toxic iodide. Respirometric bioassay illustrated that the presence of iodine increase the lag phase before the onset of oxygen consumption. The length of lag phase was proportional to increasing iodine dosage. The reduction products of iodine by ZVI did not exhibit any inhibitory effect on the biodegradation. The cumulative biological oxidation associated with iodine toxicity was closely fitted to Gompertz model. When iodine-laden wastewater was continuously fed to a bench-scale activated sludge unit, chemical oxygen demand (COD) removal efficiencies decreased from above 90% to below 80% along with a marked decrease in biomass concentration. On the other hand, the COD removal efficiency and biomass concentration remained constant in the integrated ZVI-activated sludge system. Respirometric bioassay with real iodine-laden LCD manufacturing wastewater demonstrated that ZVI was effective for detoxifying iodine and consequently enhancing biodegradability of wastewater. This result suggested that ZVI pretreatment may be a feasible option for the removal of iodine in LCD processing wastewater, instead of more costly processes such as adsorption and chemical oxidation, which are commonly in the iodine-laden LCD wastewater treatment facility.  相似文献   

5.
Fluidized zero valent iron (ZVI) process was conducted to reduce hexavalent chromium (chromate, CrO(4)(2-)) to trivalent chromium (Cr(3+)) from electroplating wastewater due to the following reasons: (1) Extremely low pH (1-2) for the electroplating wastewater favoring the ZVI reaction. (2) The ferric ion, produced from the reaction of Cr(VI) and ZVI, can act as a coagulant to assist the precipitation of Cr(OH)(3(s)) to save the coagulant cost. (3) Higher ZVI utilization for fluidized process due to abrasive motion of the ZVI. For influent chromate concentration of 418 mg/L as Cr(6+), pH 2 and ZVI dosage of 3g (41 g/L), chromate removal was only 29% with hydraulic detention time (HRT) of 1.2 min, but was increased to 99.9% by either increasing HRT to 5.6 min or adjusting pH to 1.5. For iron species at pH 2 and HRT of 1.2 min, Fe(3+) was more thermodynamically stable since oxidizing agent chromate was present. However, if pH was adjusted to 1.5 or 1, where chromate was completely removed, high Fe(2+) but very low Fe(3+) was present. It can be explained that ZVI reacted with chromate to produce Fe(2+) first and the presence of chromate would keep converting Fe(2+) to Fe(3+). Therefore, Fe(2+) is an indicator for complete reduction from Cr(VI) to Cr(III). X-ray diffraction (XRD) was conducted to exam the remained species at pH 2. ZVI, iron oxide and iron sulfide were observed, indicating the formation of iron oxide or iron sulfide could stop the chromate reduction reaction.  相似文献   

6.
The effectiveness of the Fenton's reagent (H(2)O(2)/Fe(2+)) in the treatment of carpet dyeing wastewater was investigated under different operational conditions, namely, H(2)O(2) and FeSO(4) concentrations, initial pH and temperature. Up to 95% COD removal efficiency was attained using 5.5 g/l FeSO(4) and 385 g/l H(2)O(2) at a pH of 3, temperature of 50 degrees C. The H(2)O(2)/Fe(2+) ratio (g/g) was found to be between 95 and 290 for maximum COD removal. It was noteworthy that, keeping H(2)O(2)/Fe(2+) ratio constant within the range of 95-290, it became possible to decrease FeSO(4) concentration to 1.1 g/l and H(2)O(2) concentration to 96.3 g/l, still achieving nearly the same COD removal efficiency. The relative efficiencies of Fenton's oxidation and coagulation stages revealed that Fenton's coagulation removed organic compounds which were not removed by Fenton's oxidation, indicating that the Fenton's coagulation acted as a polishing step.  相似文献   

7.
In order to treat pesticide wastewater having high chemical oxygen demand (COD) value and poor biodegradability, Fenton-coagulation process was first used to reduce COD and improve biodegradability and then was followed by biological treatment. Optimal experimental conditions for the Fenton process were determined to be Fe(2+) concentration of 40 mmol/L and H(2)O(2) dose of 97 mmol/L at initial pH 3. The interaction mechanism of organophosphorous pesticide and hydroxyl radicals was suggested to be the breakage of the P=S double bond and formation of sulfate ions and various organic intermediates, followed by formation of phosphate and consequent oxidation of intermediates. For the subsequent biological treatment, 3.2g/L Ca(OH)(2) was added to adjust the pH and further coagulate the pollutants. The COD value could be evidently decreased from 33,700 to 9300 mg/L and the ratio of biological oxygen demand (BOD(5)) to COD of the wastewater was enhanced to over 0.47 by Fenton oxidation and coagulation. The pre-treated wastewater was then subjected to biological oxidation by using moving-bed biofilm reactor (MBBR) inside which tube chip type bio-carriers were fluidized upon air bubbling. Higher than 85% of COD removal efficiency could be achieved when the bio-carrier volume fraction was kept more than 20% by feeding the pretreated wastewater containing 3000 mg/L of inlet COD at one day of hydraulic retention time (HRT), but a noticeable decrease in the COD removal efficiency when the carrier volume was decreased down to 10%, only 72% was observed. With the improvement of biodegradability by using Fenton pretreatment, also due to the high concentration of biomass and high biofilm activity using the fluidizing bio-carriers, high removal efficiency and stable operation could be achieved in the biological process even at a high COD loading of 37.5 gCOD/(m(2)carrierday).  相似文献   

8.
Bactericide wastewater (BIW) contains isothiazolin-ones, high salinity, toxicity and non-biodegradable organic concentrations. In order to enhance biodegradable capacity, chemical coagulation and electrochemical oxidation were applied to pretreatment processes. FeSO(4).7H2O, pH 12 and 20 mmol/l were determined as optimal chemical coagulation condition; and 15 mA/cm2 of current density, 10 ml/min of flow rate and pH 7 were chosen for the most efficient electrochemical oxidation condition at combined treatment. The wastewater which consisted mainly of isothiazolin-ones and sulfide was efficiently treated by chemical coagulation and electrochemical oxidation. The optimal pretreatment processes showed 60.9% of chemical oxygen demand (COD), 99.5% of S(2-) and 96.0% of isothiazolin-ones removal efficiency. A biological treatment system using membrane bioreactor (MBR) adding powder-activated carbon (PAC) was also investigated. COD of the wastewater which was disposed using a MBR was lower than 100 mg/l.  相似文献   

9.
This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.  相似文献   

10.
Electrocoagulation (EC) of cattle-slaughterhouse wastewater, which is characterized by (i) high turbidity (up to 340 Nephelometric turbidity units), (ii) increased chemical oxygen demand (COD) concentration (4200 mg L(-1)), and (iii) a dark color, was investigated with the purpose of lowering the turbidity and COD concentration to levels below the permitted direct-discharge limits. Iron and aluminum were used as electrode materials. Experiments were conducted to evaluate the effects of current density, initial pH, and supporting electrolyte (Na(2)SO(4)) dosage on the performance of the system. COD removal increased with increase in current density. The original pH of wastewater (7.8) was found to be preferable for both the electrode materials. Higher concentrations of Na(2)SO(4) caused an increase in COD removal efficiency, and energy consumption was considerably reduced with increasing conductivity. Hybrid processes were applied in this work to achieve higher COD removal efficiencies. In the case of aluminum electrode, polyaluminum chloride (PAC) was used as the coagulant aid for the aforesaid purpose. COD removal of 94.4% was obtained by adding 0.75 g L(-1) PAC. This removal efficiency corresponded to effluent COD concentration of 237 mg L(-1), which meets the legal requirement for discharge from slaughterhouses in Turkey. In the case of iron electrode, EC was conducted concurrent with the Fenton process. As a result, 81.1% COD removal was achieved by adding 9% H(2)O(2). Consequently, hybrid processes are inferred to be superior to EC alone for the removal of both COD and turbidity from cattle-slaughterhouse wastewater.  相似文献   

11.
Attempts were made in this study to examine the efficiency of Fenton process combined with coagulation for treatment of water-based printing ink wastewater. Parameters affecting the Fenton process, such as pH, dosages of Fenton reagents and the settling time, were determined by using jar test experiments. 86.4% of color and 92.4% of chemical oxygen demand (COD) could be removed at pH 4, 50mg/l H(2)O(2), 25mg/l FeSO(4) and 30min settling time. The coagulation using polyaluminium chloride (PAC) and ferrous sulfate (FeSO(4)) was beneficial to improve the Fenton process treated effluent in reducing the flocs settling time, enhancing color and COD removal. The overall color, COD and suspended solids (SS) removal reached 100%, 93.4% and 87.2% under selected conditions, respectively. Thus this study might offer an effective way for wastewater treatment of water-based ink manufacturer and printing corporation.  相似文献   

12.
Municipal landfill leachate, especially mature leachate, may disrupt the performance of moderately-sized municipal activated sludge wastewater treatment plants, and likewise tend to be recalcitrant to biological pretreatment. Recently, Fenton methods have been investigated for chemical treatment or pre-treatment of mature leachate. In this paper, the results of laboratory tests to determine the roles of oxidation and coagulation in reducing the organic content of mature leachate during Fenton treatment are presented. The efficiencies of chemical oxygen demand (COD) oxidation and coagulation were tested, and the ratio of COD removal by oxidation to that by coagulation was assessed, under various operating conditions. Low initial pH, appropriate relative and absolute Fenton reagent dosages, aeration, and stepwise addition of reagents increased COD removal by oxidation and the importance of oxidation relative to coagulation. Simultaneous aeration and stepwise reagent addition allowed comparable treatment without initial acidification pH, due to the generation of acidic organic intermediates and the continuous input of CO2. On the other hand, high COD oxidation efficiency and low ferrous dosage inhibited COD removal by coagulation. At significantly high oxidation efficiency, overall COD reduction decrease slightly due to low coagulation efficiency. Under the most favorable conditions (initial pH 3, molar ratio [H(2)O(2)]/[Fe2+]=3, [H2O2]=240 mM, and six dosing steps), 61% of the initial COD was removed, and the ratio of COD removal oxidation to coagulation was 0.75. Results highlighted the synergistic roles of oxidation and coagulation in Fenton treatment of mature leachate, and the role of oxidation in controlling the efficiency of removal of COD by coagulation.  相似文献   

13.
This paper examines the use of chemical or electrocoagulation treatment process followed by ion-exchange process of the textile dye effluent. The dye effluent was treated using polymeric coagulant (cationic dye-fixing agent) or electrocoagulation (iron and aluminum electrode) process under various conditions such as various current densities and effect of pH. Efficiencies of COD reduction, colour removal and power consumption were studied for each process. The chemical or electrochemical treatment are indented primarily to remove colour and COD of wastewater while ion exchange is used to further improve the removal efficiency of the colour, COD, Fe concentration, conductivity, alkalinity and total dissolved solids (TDS). From the results chemical coagulation, maximum COD reduction of about 81.3% was obtained at 300 mg/l of coagulant whereas in electrocoagulation process, maximum COD removal of about 92.31% (0.25 A/dm2) was achieved with energy consumption of about 19.29 k Wh/kg of COD and 80% (1A/dm(2)) COD removal was obtained with energy consumption of about 130.095 k Wh/kg of COD at iron and aluminum electrodes, respectively. All the experimental results, throughout the present study, have indicated that chemical or electrocoagulation treatment followed by ion-exchange methods were very effective and were capable of elevating quality of the treated wastewater effluent to the reuse standard of the textile industry.  相似文献   

14.
As a consequence of the population growth, major efforts have been made by the Egyptian government to construct new industrial areas. Tenth of Ramadan City is one of the most important industrial cities in Egypt. The wastewater generated from various industrial activities was highly contaminated with organic matters as indicated by COD (1750-3323 mg/L), TSS (900-3000 mg/L) and oil and grease (13.2-95.5 mg/L). All overall appraisals of the analytical data from the industrial wastewater indicate that pretreatment is required for all industrial sectors to achieve compliance with the Egyptian Environmental law which requires effective pretreatment of industrial wastewater prior to its discharge into public sewers. Treatability studies via conventional and Fenton processes have been investigated. The efficiency of conventional treatment methods led to 63% COD and 44% color removal by using FeCl(3) as coagulant. Various coagulant aids and powdered activated carbon (PAC) were added to 400mg/L FeCl(3) in order to enhance the removal of color. It was found that polyacrylamide polymer, bentonite and PAC increased the efficiency of the treatments where the color removal increased to 79%, by cationic polymer, 73% by anionic polymer, 84.5% by bentonite and 95% for 0.4 g/L PAC. Fenton process was investigated which under the operating conditions (pH 3.0+/-0.2, Fe(2+) dose=400 mg/L and H(2)O(2)=550 mg/L), color removal up to 100% and more than 90% of COD removal were achieved.  相似文献   

15.
Performance of a full-scale combined treatment plant for jean-wash wastewater (JWW) was investigated. The combined process consisted of chemical coagulation, hydrolysis/acidification and Fenton oxidation. Chemical coagulation treatment with polymeric ferric sulfate (PFS)/lime alone proved to be effective in removing the COD (>70%) and part of the color (>50%) from the JWW. Fenton oxidation combined with hydrolysis/acidification as pretreatment offered a noticeable BOD removal efficiency. The average removal efficiencies for COD, BOD, SS, color and aromatic compounds of the combined process were about 95%, 94%, 97%, 95% and 90%, respectively, with the average effluent quality of COD 58 mg/L, BOD 19 mg/L, SS 4 mg/L and color 15(multiple), consistent with the national discharge limits for textile wastewater. The result indicated that the combined procedure could offer an attractive solution for JWW treatment with considerable synergistic advantages.  相似文献   

16.
This study investigates the efficiency of zero valent iron (ZVI) to remove arsenate from water. Batch experiments were carried out to study the removal kinetics of arsenate under different pH values and in the presence of low and high concentrations of various anions (chloride, carbonate, nitrate, phosphate, sulphate and borate), manganese and dissolved organic matter. Borate and organic matter, particularly at higher concentrations, inhibited the removal of arsenic. Column tests were carried out to investigate the removal of arsenate from tap water under dynamic conditions. The concentrations of arsenic and iron as well as the pH and Eh were measured in treated water. Efficient removal of arsenate was observed resulting at concentrations below the limit of 10 μg/L in treated waters.  相似文献   

17.
Electrochemical treatment of deproteinated whey wastewater produced during cheese manufacture was studied as an alternative treatment method for the first time in literature. Through the preliminary batch runs, appropriate electrode material was determined as iron due to high removal efficiency of chemical oxygen demand (COD), and turbidity. The electrochemical treatment conditions were optimized through response surface methodology (RSM), where applied voltage was kept in the range, electrolyte concentration was minimized, waste concentration and COD removal percent were maximized at 25 degrees C. Optimum conditions at 25 degrees C were estimated through RSM as 11.29 V applied voltage, 100% waste concentration (containing 40 g/L lactose) and 19.87 g/L electrolyte concentration to achieve 29.27% COD removal. However, highest COD removal through the set of runs was found as 53.32% within 8h. These results reveal the applicability of electrochemical treatment to the deproteinated whey wastewater as an alternative advanced wastewater treatment method.  相似文献   

18.
The applicability of Fenton's oxidation to improve the biodegradability of a pharmaceutical wastewater to be treated biologically was investigated. The wastewater was originated from a factory producing a variety of pharmaceutical chemicals. Treatability studies were conducted under laboratory conditions with all chemicals (having COD varying from 900 to 7000 mg/L) produced in the factory in order to determine the operational conditions to utilize in the full-scale treatment plant. Optimum pH was determined as 3.5 and 7.0 for the first (oxidation) and second stage (coagulation) of the Fenton process, respectively. For all chemicals, COD removal efficiency was highest when the molar ratio of H(2)O(2)/Fe(2+) was 150-250. At H(2)O(2)/Fe(2+) ratio of 155, 0.3M H(2)O(2) and 0.002 M Fe(2+), provided 45-65% COD removal. The wastewater treatment plant that employs Fenton oxidation followed by aerobic degradation in sequencing batch reactors (SBR), built after these treatability studies provided an overall COD removal efficiency of 98%, and compliance with the discharge limits. The efficiency of the Fenton's oxidation was around 45-50% and the efficiency in the SBR system which has two reactors each having a volume of 8m(3) and operated with a total cycle time of 1 day, was around 98%, regarding the COD removal.  相似文献   

19.
采用低温等离子体技术处理含聚丙烯酰胺(PAM)废水,研究了放电电压、放电时间、溶液pH对不同浓度PAM溶液化学需氧量(COD)降解率的影响规律,同时还研究了不放电条件下PAM溶液pH以及放电条件下放电时间对不同浓度PAM溶液黏度去除率的影响,考察了放电条件下pH对质量浓度1.0g/L PAM溶液黏度去除率的影响规律。通过正交试验确定影响PAM溶液COD降解率的主次顺序为:放电时间>放电电压>溶液浓度>溶液pH。在放电时间5h、放电电压40kV、PAM溶液质量浓度1.0g/L、pH=1.5时,COD降解率最佳,可达85.74%。  相似文献   

20.
The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (+/-0.2) and a total COD of 12,100 (+/-910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32+/-2 degrees C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m3day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe2+ and H2O2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H2O2 and Fe2+ dosages, and the ratio of H2O2/Fe2+. Preliminary tests conducted with the dosages of 100 mg Fe2+/L and 200 mg H2O2/L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe2+ and H2O2 were investigated. Under the condition of 400 mg Fe2+/L and 200 mg H2O2/L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe2+/L and 1200 mg H2O2/L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号