共查询到20条相似文献,搜索用时 0 毫秒
1.
U Schaudig A Hassenstein A Bernd A Walter G Richard 《Canadian Metallurgical Quarterly》1998,236(8):588-592
AIM: To study the immunohistochemical expression of the Thomsen-Friedenreich antigen (T) and its precursor, Tn, in the skin in various cancers. METHODS: T and Tn antigens were studied with monoclonal antibodies in 91 primary premalignant and malignant lesions, 13 cases of Paget's disease, and 26 carcinomas metastatic to the skin. The material had been collected over a 10 year period, formalin fixed, and paraffin embedded. Diagnoses had been made after examination of standard histological sections, supplemented when needed by appropriate immunohistochemical staining. RESULTS: 21% and 29% of the primary cutaneous premalignant and malignant epithelial tumours expressed the Tn and T antigens, respectively. By contrast, 81% of metastatic carcinomas to the skin were Tn positive, while only 23% of them expressed the T antigen. All cases of Paget's disease were Tn positive but only 15% of them expressed the T antigen. The 21 nonepithelial tumours (including melanomas) were as a rule unreactive. CONCLUSIONS: The accumulation of the precursor (Tn) antigen in tumours metastasising to the skin highlights the incomplete glycosylation of carbohydrate antigens occurring in these tumours. The predominant Tn versus T antigen expression appears to be a useful immunohistochemical feature which may aid in the differentiation of primary cutaneous carcinomas from metastatic tumours. 相似文献
2.
MR Hee CA Puliafito JS Duker E Reichel JG Coker JR Wilkins JS Schuman EA Swanson JG Fujimoto 《Canadian Metallurgical Quarterly》1998,105(2):360-370
OBJECTIVE: This study aimed to develop a protocol to screen and monitor patients with diabetic macular thickening using optical coherence tomography (OCT), a technique for high-resolution cross-sectional imaging of the retina. DESIGN: A cross-sectional pilot study was conducted. PARTICIPANTS: A total of 182 eyes of 107 patients with diabetic retinopathy, 55 eyes from 31 patients with diabetes but no ophthalmoscopic evidence of retinopathy, and 73 eyes from 41 healthy volunteers were studied. INTERVENTION: Six optical coherence tomograms were obtained in a radial spoke pattern centered on the fovea. Retinal thickness was computed automatically from each tomogram at a total of 600 locations throughout the macula. Macular thickness was displayed geographically as a false-color topographic map and was reported numerically as averages in each of nine regions. MAIN OUTCOME MEASURES: Correlation of OCT with slit-lamp biomicroscopy, fluorescein angiography, and visual acuity was measured. RESULTS: Optical coherence tomography was able to quantify the development and resolution of both foveal and extrafoveal macular thickening. The mean +/- standard deviation foveal thickness was 174 +/- 18 microns in normal eyes, 179 +/- 17 microns in diabetic eyes without retinopathy, and 256 +/- 114 microns in eyes with nonproliferative diabetic retinopathy. Foveal thickness was highly correlated among left and right eyes of normal eyes (mean +/- standard deviation difference of 6 +/- 9 microns). Foveal thickness measured by OCT correlated with visual acuity (r2 = 0.79). A single diabetic eye with no slit-lamp evidence of retinopathy showed abnormal foveal thickening on OCT. CONCLUSIONS: Optical coherence tomography was a useful technique for quantifying macular thickness in patients with diabetic macular edema. The topographic mapping protocol provided geographic information on macular thickness that was intuitive and objective. 相似文献
3.
K Kobayashi JA Izatt MD Kulkarni J Willis MV Sivak 《Canadian Metallurgical Quarterly》1998,47(6):515-523
BACKGROUND: Optical coherence tomography (OCT) is a novel technique for noninvasive cross-sectional imaging with high spatial resolution (10 to 20 microm). OCT is similar to B-mode ultrasound except that it uses infrared light rather than ultrasound. We studied OCT imaging of the gastrointestinal (GI) tract in vitro to analyze the potential of this technique for endoscopic applications. METHODS: Human gastrointestinal tissues harvested from surgical resection and autopsy specimens were used. Specimens were imaged within 5 hours of resection or snap frozen in liquid nitrogen. After imaging, OCT scan locations were carefully marked using dye microinjections, fixed, and prepared for routine histologic processing. OCT images were then compared and correlated with the histologic sections. RESULTS: OCT images demonstrated clear delineation of the mucosa and submucosa in most specimens. Furthermore, microscopic structures such as crypts, blood vessels, or esophageal glands in the submucosa and lymphatic nodules were observed. CONCLUSIONS: The resolution of OCT images of GI wall is sufficient to delineate the microscopic structure of the mucosa and submucosa. Potentially, OCT would allow in vivo imaging at endoscopy of the microstructure of the mucosa and submucosa. This would be particularly useful in the detection and staging of small lesions such as early stage cancers. 相似文献
4.
OBJECTIVE: Optic nerve head drusen often make evaluation of the nerve head difficult to interpret. In addition, visual field defects are known to occur in patients with optic disk drusen, resembling glaucomatous damage. The authors report two cases of coincident optic nerve head drusen and glaucoma, in which the use of optical coherence tomography (OCT) in evaluating the nerve fiber layer was beneficial. PARTICIPANTS: Two patients with both optic nerve head drusen and glaucoma, one with primary open angle glaucoma, the other with pseudoexfoliation glaucoma were evaluated. Both patients had asymmetric optic disk drusen, with clinically visible drusen only in one eye. INTERVENTION: Ophthalmologic examination, color and red-free photography, automated Humphrey visual field testing and OCT were performed. RESULTS: Nerve fiber layer loss as measured by OCT was found to be greater than expected by the appearance of the optic nerve head and red-free photography, with visual fields consistent with findings in case 1. In case 2, visual fields were full, despite nerve fiber layer thinning seen by OCT and red-free photography. CONCLUSIONS: There can be significant nerve fiber layer thinning in patients with both glaucoma and optic disk drusen, despite the appearance of the optic nerve head in these patients. The cup margin may be obscured by the drusen, giving rise to a falsely full-appearing disk. In such cases, OCT may provide a useful means to quantitatively measure the nerve fiber layer thickness and to aid in the management of these patients by detecting nerve fiber layer thinning earlier than would otherwise be possible. 相似文献
5.
OBJECTIVE: Intraoperative identification of brain tumors and tumor margins has been limited by either the resolution of the in vivo imaging technique or the time required to obtain histological specimens. Our objective was to evaluate the feasibility of using optical coherence tomography (OCT) as a high-resolution, real-time intraoperative imaging technique to identify an intracortical melanoma. INSTRUMENTATION: OCT is a new, noncontact, high-speed imaging technology capable of resolutions on the micrometer scale. OCT is analogous to ultrasound B-mode imaging, except that reflections of infrared light, rather than sound, are detected. OCT uses inherent tissue contrast, rather than enhancement with dyes, to differentiate tissue types. The compact, fiberoptic-based design is readily integrated with surgical instruments. METHODS: A portable handheld OCT surgical imaging probe has been constructed for imaging within the surgical field. Cadaveric human cortex with metastatic melanoma was harvested and imaged in two and three dimensions. Changes in optical backscatter intensity were used to identify regions of tumor and to locate tumor margins. Structures within the optical coherence tomographic images were compared with the histological slides. RESULTS: Two-dimensional images showed increased optical backscatter from regions of tumor, which was quantitatively used to determine the tumor margin. The images correlated well with the histological findings. Three-dimensional reconstructions revealed regions of tumor penetrating normal cortex and could be resectioned at arbitrary planes. Subsurface cerebral vascular structures could be identified and were therefore avoided. CONCLUSION: OCT can effectively differentiate normal cortex from intracortical melanoma based on variations in optical backscatter. The high-resolution, high-speed imaging capabilities of OCT may permit the intraoperative identification of tumor and the more precise localization of tumor margins. 相似文献
6.
JS Schuman T Pedut-Kloizman E Hertzmark MR Hee JR Wilkins JG Coker CA Puliafito JG Fujimoto EA Swanson 《Canadian Metallurgical Quarterly》1996,103(11):1889-1898
PURPOSE: Optical coherence tomography (OCT) is a new technology that uses near-infrared light in an interferometer to produce approximately 10-microns resolution cross-sectional images of the tissue of interest. The authors performed repeated quantitative assessment of nerve fiber layer thickness in individuals with normal and glaucomatous eyes, and they evaluated the reproducibility of these measurements. METHODS: The authors studied 21 eyes of 21 subjects by OCT. Each subject underwent five repetitions of a series of scans on five separate occasions within a 1-month period. Each series consisted of three circular scans around the optic nerve head (diameters, 2.9, 3.4, and 4.5 mm). Each series was performed separately using internal (fixation with same eye being studied) and external (fixation with contralateral eye) fixation techniques. The eye studied and the sequence of testing were assigned randomly. RESULTS: Internal fixation (IF), in general, provides a slightly higher degree of reproducibility than external fixation (EF). Reproducibility was better in a given eye on a given visit than from visit to visit. Reproducibility as measured by intraclass correlation coefficients were as follows: circle diameter (CD), 2.9 mm, 0.51/0.57 (normal/glaucoma) (IF), 0.43/0.54 (EF); CD, 3.4 mm, 0.56/0.52 (IF), 0.43/0.61 (EF); CD, 4.5 mm, 0.53/0.43 (IF), 0.42/0.49 (EF). CONCLUSIONS: Nerve fiber layer thickness can be reproducibly measured using OCT. Internal is superior to external fixation; each circle diameter tested provides adequate reproducibility. 相似文献
7.
DJ Smithies T Lindmo Z Chen JS Nelson TE Milner 《Canadian Metallurgical Quarterly》1998,43(10):3025-3044
A Monte Carlo model has been developed for optical coherence tomography (OCT). A geometrical optics implementation of the OCT probe with low-coherence interferometric detection was combined with three-dimensional stochastic Monte Carlo modelling of photon propagation in the homogeneous sample medium. Optical properties of the sample were selected to simulate intralipid and blood, representing moderately (g = 0.7) and highly (g = 0.99) anisotropic scattering respectively. For shallow optical depths in simulated intralipid (<3 scattering mean free path (mfp) units), the number of detected backscattered photons followed the extinction-single-backscatter model, and OCT was found to detect only minimally scattered photons. Within this depth range the backscatter positions of detected photons corresponded well with the nominal focus position of the probe. For propagation to deeper positions in intralipid, localization of backscattering was quickly lost due to detection of stray photons, and the number of detected photons remained constant with increasing depth in the non-absorbing medium. For strongly forward-directed scattering in simulated blood, the number of detected photons approached the extinction-single-backscatter model only for very shallow depths (<2 mfp units). However, backscattering positions for detected photons correlated well with the nominal focus position of the probe even for optical depths greater than 40 mfp units. 相似文献
8.
CA Toth DG Narayan SA Boppart MR Hee JG Fujimoto R Birngruber CP Cain CD DiCarlo WP Roach 《Canadian Metallurgical Quarterly》1997,115(11):1425-1428
OBJECTIVE: To compare the cross-sectional images of primate retinal morphology obtained by optical coherence tomography (OCT) with light microscopy to determine the retinal components represented in OCT images. METHODS: Laser pulses were delivered to the retina to create small marker lesions in a Macaca mulatta. These lesions were used to align in vivo OCT scans and ex vivum histologic cross sections for image comparison. RESULTS: The OCT images demonstrated reproducible patterns of retinal morphology that corresponded to the location of retinal layers seen on light microscopic overlays. Layers of relative high reflectivity corresponded to horizontally aligned retinal components such as the nerve fiber layer and plexiform layers, as well as to the retinal pigment epithelium and choroid. In contrast, the nuclear layers and the photoreceptor inner and outer segments demonstrated relative low reflectivity by OCT. CONCLUSIONS: Retinal morphology and macular OCT imaging correlate well, with alignment of areas of high and low reflectivity to specific retinal and choroidal elements. Resolution of retinal structures by OCT depends on the contrast in relative reflectivity of adjacent structures. Use of this tool will enable expanded study of retinal morphology, both normal and pathologic, as it evolves in vivo. 相似文献
9.
提出了基于免疫遗传算法的形态学自适应结构元素生成算法,并将其用于光学相干断层成像(optical coherence tomography,OCT)图像中视网膜组织边缘检测.首先将图像进行去噪和粗分割的预处理,并将图像划分为若干子图像;其次对每一子图利用免疫遗传算法求取自适应结构元,初始随机生成固定长度的二进制数串作为抗体,并将其转化为结构元素格式,以图像二维熵定义抗体适应度,根据子图像本身结构特征信息,寻找最优抗体结构元素;最后利用寻优得到的各结构元素对子图进行形态学边缘检测,合并各子图的分割结果,实现整体图像目标边界提取.实验结果表明了该方法在图像目标边界提取的有效性. 相似文献
10.
提出了基于免疫遗传算法的形态学自适应结构元素生成算法,并将其用于光学相干断层成像(optical coherence tomography,OCT) 图像中视网膜组织边缘检测. 首先将图像进行去噪和粗分割的预处理,并将图像划分为若干子图像; 其次对每一子图利用免疫遗传算法求取自适应结构元,初始随机生成固定长度的二进制数串作为抗体,并将其转化为结构元素格式,以图像二维熵定义抗体适应度,根据子图像本身结构特征信息,寻找最优抗体结构元素; 最后利用寻优得到的各结构元素对子图进行形态学边缘检测,合并各子图的分割结果,实现整体图像目标边界提取. 实验结果表明了该方法在图像目标边界提取的有效性. 相似文献
11.
PURPOSE: To evaluate macular thickness changes after uneventful cataract surgery using optical coherence tomography (OCT) and compare the findings with those of flare and cell measurements of the anterior chamber. SETTING: Clinique Sourdille, Nantes, France. METHODS: In this retrospective study, 41 eyes having uneventful cataract surgery with a clear corneal small incision and intracapsular fixation of a foldable intraocular lens were evaluated by OCT and laser flare and cell measurements preoperatively and 1, 8 to 12, and 30 to 60 days postoperatively. RESULTS: Some postoperative increase in macular thickness was noted in 11 eyes. This was not related to a higher postoperative flare. Visual consequences were proportional to the macular elevation. CONCLUSION: Clinical and subclinical thickness changes, without breakdown of the blood-aqueous barrier, can be detected after cataract surgery. Most of these changes resolve spontaneously, but their mid- and long-term significance is unknown. 相似文献
12.
A Becker C Becker A Knez R Haberl R Brüning M Reiser G Steinbeck 《Canadian Metallurgical Quarterly》1998,38(12):1021-1028
PURPOSE: Electron-beam computed tomography (EBCT) enables examinations with a very short acquisition time of 50 ms and thus permits cardiac imaging without motion artifacts. Utilizing eight detector rings simultaneous image acquisition in up to eight levels and complete imaging of the whole heart is possible. In studies, functional imaging with EBCT was compared to our angiocardiography, echocardiography, radionuclide, ventriculography and magnetic resonance tomography. MATERIALS AND METHODS: ECG-triggered long- and short-axis cine studies were performed with the Imatron C-150 Evolution, acquiring 160 and 156 images at 8 and 12 levels. After manual tracing of epicardial and endocardial borders, ventricular size, ejection fraction, wall-thickening and myocardial mass were calculated. RESULTS: A very high correlation between EBCT and direct determination of right and left ventricle (r = 0.98 and r = 0.99) was demonstrated. Compared to echocardiography, angiocardiography and radionuclide ventriculography, assessment of ventricular function was more precise and more reliable. DISCUSSION: EBCT allows the exact and reliable determination of left and right ventricular function. Also precise assessment of myocardial mass is possible. However, the high radiation exposure and diagnostic effort have to be considered. 相似文献
13.
Y Imai S Sone S Serizawa SH Bae N Imai M Hasegawa K Yamashita 《Canadian Metallurgical Quarterly》1995,55(8):562-568
The magnetic resonance (MR) imaging and computed tomography (CT) findings in four patients (five kidneys) with non-Hodgkin's lymphoma involving the kidneys and perirenal spaces are presented. The patterns of disease in each case were as follows: bilateral renal nodules, infiltration in the perirenal space, infiltration in the perirenal space with renal involvement, and direct invasion from contiguous retroperitoneum. On plain CT, the lesions showed slight hyperdensity (three kidneys) and isodensity (two kidneys) as compared with normal renal parenchyma. But all lesions appeared as hypodense masses with more definite margins after contrast enhancement. MR imaging findings showed iso- or slight hypointense masses on T1-weighted images and definite hypointense masses on T2-weighted images as compared with the signal intensity of the renal cortex. Dynamic imaging and conventional delayed T1-weighted imaging following Gd-DTPA injection showed no significant enhancement of the lesions. In comparison with contrast enhanced CT, despite its poorer resolution, T2-weighted MR imaging showed nearly the same accuracy in the evaluation of number and extent of the lesions without contrast medium administration. MR imaging was also useful to evaluate the patency of vessel lumen surrounded by tumor mass and to determine the location and extent of huge lesions by its multiplanar imaging capabilities. 相似文献
14.
15.
16.
Significant technologic advances have taken place in computed tomography (CT). Current-generation conventional CT scanners are able to image a slice of tissue in as little as 2 to 3 seconds and can acquire several consecutive images. Although it is a substantial improvement from the CT of 5 years ago, there remain practical limits to the utility of conventional CT imaging within the abdomen. Recently, a new type of CT gantry design ("slip-ring") and faster computers have contributed to the development of a new generation of CT scanners, the "helical" or "spiral" CT scanners. 相似文献
17.
18.
P Ponce MV Alvarez-Santullano E Otermin MA Santana MV García Lude?a 《Canadian Metallurgical Quarterly》1998,28(3):226-229
OBJECTIVES: In an effort to critically examine the antitumor activity of altretamine (hexamethylmelamine) as salvage therapy of platinum-refractory ovarian cancer, the Gynecologic Oncology Group initiated a Phase II trial of the agent administered in this clinical setting. METHODS: Altretamine was administered at a dose of 260 mg/m2 orally for 14 days in a 28-day course. Treatment was continued until disease progression or unacceptable side effects prevented further therapy. A total of 36 patients (median age: 56.5) were treated on this trial, of whom 33 were evaluable for toxicity and 30 for response. All patients had previously received either cisplatin or carboplatin and paclitaxel. RESULTS: The major side effect was emesis (grade 3-4, 7/33, 21%). The objective response rate was 10% (one complete response, two partial responses). CONCLUSION: We conclude that altretamine has limited activity in platinum-refractory ovarian cancer. 相似文献
19.
F Bénard D Sterman RJ Smith LR Kaiser SM Albelda A Alavi 《Canadian Metallurgical Quarterly》1998,114(3):713-722
BACKGROUND: The diagnosis of malignant mesothelioma is a challenging medical problem. CT often cannot differentiate between benign diffuse pleural thickening and malignant mesothelioma, while thoracentesis and CT-guided biopsies are insensitive. We have assessed the value of positron emission tomography (PET) with 2-fluoro-2-deoxy-D-glucose (FDG) in the evaluation of malignant mesothelioma. METHODS: Twenty-eight consecutive patients referred for the evaluation of suspected malignant mesothelioma were evaluated by FDG-PET imaging. Measured attenuation correction was performed in 26 of 28 cases for quantitation with the standardized uptake value (SUV) method. The results of PET imaging were compared with those of video-assisted thoracoscopy or surgical biopsies. RESULTS: Surgical biopsy specimens confirmed the presence of malignant disease in 24 patients and demonstrated benign processes in the remaining four. The uptake of FDG was significantly higher in malignant than in benign lesions (SUV=4.9+/-2.9 and SUV=1.4+/-0.6, respectively; p<0.0001). With a SUV cutoff of 2.0 to differentiate between malignant and benign disease, a sensitivity of 91% and a specificity of 100% could be achieved, although the activity in some epithelial mesotheliomas tended to be close to this threshold. FDG-PET images provided excellent delineation of the active tumor sites. Hypermetabolic lymph node involvement was noted on FDG-PET images in 12 patients, 9 of which appeared normal on CT scans. Histologic examination in six patients confirmed malignant nodal disease in five cases and indicated granulomatous lymphadenitis in one. CONCLUSION: In this highly selected population, FDG-PET imaging was a sensitive method to identify malignant mesothelioma and determine the extent of the disease process. 相似文献