首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 69 毫秒
1.
The combined generation of electricity by wind and solar energy is a very attractive solution for isolated regions with high levels of yearly wind energy and insolation. A computer model is developed for the simulation of the electricity system of a Mediterranean island, including a wind power plant, a photovoltaic power plant and a storage system. In order to obtain an overall view of the system performance and economic aspects, the model also incorporates a number of diesel generators. Daily simulations for the Greek island Kythnos show that such a combined system of moderate size can provide a large fraction of the electrical energy requirements. Various parameters calculated in the simulation can be used to improve the configuration of the system and to estimate the cost of the electrical energy unit.  相似文献   

2.
In this work, a combined system which is produced electrical energy from both solar radiation via solar cells and wind energy by using wind turbine was studied. For wind energy, measurements of wind velocities at 12 m height were taken. Then, these values were calculated for 42 m by using Hellmann equation. After that, wind energy converted to the electrical energy. However, value of solar radiation from solar cells was taken at the optimum slope angle of collector which provided higher energy production for each 1 h during this application. Thus, obtained data from each system were used together for finding total energy. For this study, measurements, which would be used in calculation of wind energy and solar energy were taken for four years between 1995 and 1998 in Izmir. As a result, energy of the combined system could support each other when one of them produces energy insufficiently.  相似文献   

3.
Understanding the variability of wind power costs   总被引:1,自引:0,他引:1  
Wind power has a significant contribution to make in efforts to abate CO2 emissions from global energy systems. Currently, wind power generation costs are approaching parity with costs attributed to conventional, carbon-based sources of energy but the economic advantage still rests decidedly with conventional sources. Therefore, there is an imperative to ensure that wind power projects are developed in the most economically optimal fashion. For wind power project developers, shaving a few tenths of a cent off of the kilowatts per hour cost of wind power can mean the difference between a commercially viable project and a non-starter. For civic authorities who are responsible for managing municipally supported wind power projects, optimizing the economics of such projects can attenuate stakeholder opposition. This paper attempts to contribute to a better understanding of how to economically optimise wind power projects by conflating research from the fields of energy economics, wind power engineering, aerodynamics, geography and climate science to identify critical factors that influence the economic optimization of wind power projects.  相似文献   

4.
In this paper, the optimum temperature of operation of a solar concentrator and thus the maximum power obtained from a solar thermal power plant has been calculated. Results are plotted graphically and discussed.  相似文献   

5.
This is Part II of two papers evaluating the feasibility of providing all energy for all purposes (electric power, transportation, and heating/cooling), everywhere in the world, from wind, water, and the sun (WWS). In Part I, we described the prominent renewable energy plans that have been proposed and discussed the characteristics of WWS energy systems, the global demand for and availability of WWS energy, quantities and areas required for WWS infrastructure, and supplies of critical materials. Here, we discuss methods of addressing the variability of WWS energy to ensure that power supply reliably matches demand (including interconnecting geographically dispersed resources, using hydroelectricity, using demand-response management, storing electric power on site, over-sizing peak generation capacity and producing hydrogen with the excess, storing electric power in vehicle batteries, and forecasting weather to project energy supplies), the economics of WWS generation and transmission, the economics of WWS use in transportation, and policy measures needed to enhance the viability of a WWS system. We find that the cost of energy in a 100% WWS will be similar to the cost today. We conclude that barriers to a 100% conversion to WWS power worldwide are primarily social and political, not technological or even economic.  相似文献   

6.
The cogeneration of electricity and potable water utilising solar energy is studied, assuming solar tower power plants with the open volumetric PHOEBUS receiver. The results for alternative plant configurations show that the water production cost is about the same or even lower than the cost of water produced by conventionally fired systems. Furthermore, the integration offers a reduction of CO2-emissions related to the water production of up to 50%, additionally to the environmental benefits of solar electricity production.  相似文献   

7.
Climate change, pollution, and energy insecurity are among the greatest problems of our time. Addressing them requires major changes in our energy infrastructure. Here, we analyze the feasibility of providing worldwide energy for all purposes (electric power, transportation, heating/cooling, etc.) from wind, water, and sunlight (WWS). In Part I, we discuss WWS energy system characteristics, current and future energy demand, availability of WWS resources, numbers of WWS devices, and area and material requirements. In Part II, we address variability, economics, and policy of WWS energy. We estimate that ∼3,800,000 5 MW wind turbines, ∼49,000 300 MW concentrated solar plants, ∼40,000 300 MW solar PV power plants, ∼1.7 billion 3 kW rooftop PV systems, ∼5350 100 MW geothermal power plants, ∼270 new 1300 MW hydroelectric power plants, ∼720,000 0.75 MW wave devices, and ∼490,000 1 MW tidal turbines can power a 2030 WWS world that uses electricity and electrolytic hydrogen for all purposes. Such a WWS infrastructure reduces world power demand by 30% and requires only ∼0.41% and ∼0.59% more of the world's land for footprint and spacing, respectively. We suggest producing all new energy with WWS by 2030 and replacing the pre-existing energy by 2050. Barriers to the plan are primarily social and political, not technological or economic. The energy cost in a WWS world should be similar to that today.  相似文献   

8.
Energy generated from wind turbine depends to a great extent on the wind speed at its inlet. The use of thermosyphon solar tower is an attempt to increase the air velocity at inlet of the wind turbine and of course to increase its power. The wind speed in a certain location changes always with time and with the height above ground surface. In this work, the effect of wind speed at the top of the tower on the performance as well as on the energy generated from thermosyphon solar turbine was studied theoretically. One location in Egypt was chosen for this study. The calculations were achieved mainly with the solar turbine located at tower bottom. For the purpose of comparison, the energy generated from the solar turbine was compared with that generated from free wind turbine at tower height with the absence of solar tower. It was found that, the wind speed at the top of the tower results in a pressure drop which affects the performance of the thermosyphon solar turbine. This pressure drop increases with the rise in wind speed and will be zero only when the wind speed at the top of the tower reaches zero. It was found also that, there is an increase in friction losses through the tower and a decrease in both temperature difference between inlet and outlet of the tower and in heat losses from tower walls with the rise in wind speed in location. The inlet air velocity to the solar turbine and consequently its specific power were found to be increased with the increase in wind speed at the top of the tower. Therefore, the effect of wind speed at the top of the tower must be taken into account during thermosyphon solar tower calculations. By comparing the performance of solar turbine and the free wind turbine located at tower height with the absence of thermosyphon solar tower, it was found that the mean inlet air velocity to the solar turbine located at tower bottom and consequently its specific power are higher than these values for free wind turbine. The mean inlet air velocity to the solar turbine is found to be 117% of its value for a free wind turbine. The yearly specific energy generated from solar turbine is expected to be 157% of its value for free wind turbine.  相似文献   

9.
H. Lund  E. Münster 《Renewable Energy》2003,28(14):2179-2193
This paper presents the energy system analysis model EnergyPLAN, which has been used to analyse the integration of large scale wind power into the national Danish electricity system. The main purpose of the EnergyPLAN model is to design suitable national energy planning strategies by analysing the consequences of different national energy investments. The model emphasises the analysis of different regulation strategies and different market economic optimisation strategies.At present wind power supply 15% of the Danish electricity demand and ca 50% is produced in CHP (combined heat and power production). The model has been used in the work of an expert group conducted by the Danish Energy Agency for the Danish Parliament. Results are included in the paper in terms of strategies, in order to manage the integration of CHP and wind power in the future Danish energy supply in which more than 40% of the supply is expected to come from wind power.  相似文献   

10.
This paper forecasts the supply curve of non-conventional renewable technologies such as wind and solar generating stations in Argentina, Brazil, Chile and Mexico using technological and economic parameters. It also estimates the additional investment costs in solar and wind generation for reaching the renewable energy target in each of these countries. To assess the power supply profile from 1 axis tracking PV and horizontal axis wind turbine (three blade) stations, two different scenarios are developed for 2014 and 2025. Scenario 1 estimates the PV and wind annual electricity yield by using polycrystalline silicon (cSi poly) as semiconductor material for PV cells and a Vestas 90–3.0 MW turbine for the wind for 2014.Scenario 2 assumes a more efficient technology, such as CPV. In fact, the model employs 45% efficiency triple junction cells using ∼3500 m2 for each 1 MW installed capacity in 2025. Moreover, this scenario also assumes a more powerful type of turbine, i.e. Vestas 112–3.075 MW. The biggest potential for wind power is found to be in Argentina, followed by Brazil, Mexico and Chile. In addition, a 550 MW installed capacity CPV power station, using triple junction cells could generate up to 4 TWh in Chile in 2025.  相似文献   

11.
Power production from renewable sources is identified as one of the tools to attain sustainable development in economic and social terms in Brazil. Awareness of how to prioritize renewable energy sources and technologies becomes increasingly important. Solar and wind energy have been highlighted in this context as being clean, safe and also relatively mature technologies. In addition, they are also renowned for having great energy potential and allowing different mounting options for energy harvesting systems. This article seeks to contribute to the knowledge of the effects that the key attributes, location, area and shape, of a site can have on the potential of renewable generation. In order to incorporate these attributes into an integrated analysis, a comparison method is developed and subsequently applied in a case study for two Brazilian cities. Results indicate that the amount of energy obtained by a given power generation system can undergo large variations depending on the characteristics of attributes such as site location, area and shape. This variation may ultra-pass 200%, in some cases, which demonstrates the importance of a better understanding of the role of these attributes in determining energy production.  相似文献   

12.
A demonstrative study for the wind and solar hybrid power system   总被引:1,自引:0,他引:1  
In March 1995, a small scale wind and solar hybrid power system was installed at Ashikaga Institute of Technology. Until now, the authors have acquired the data of the output of the hybrid power plant along with wind speed, wind direction, and the solar radiation, in order to demonstrate a complementary relationship between solar energy and wind energy.After nine months operation of the system, the authors confirmed that there exists a complementary relationship between solar energy and wind energy. We also found, however, that the power output by wind does not have much prospect compared to that by solar cell especially in summer season in Ashikaga area.  相似文献   

13.
Daily values of solar and wind energy have been used (i) to study renewable energy availability at various times of year, (ii) to test the level of persistence for inferences about the practicality of energy storage and (iii) to examine the complementary behaviour of these two daily time series on both seasonal and daily bases. Results for the station studied (central Iowa) show a bimodal distribution for winter solar energy, whereas non-winter solar and wind (all seasons) show unimodal distributions. Wind and solar energy were observed to be highly complementary on an annual basis, but only slightly complementary on a daily basis.  相似文献   

14.
The term integrated solar combined-cycle (ISCC) has been used to define the combination of solar thermal energy into a natural gas combined-cycle (NGCC) power plant. Based on a detailed thermodynamic cycle model for a reference ISCC plant, the impact of solar addition is thoroughly evaluated for a wide range of input parameters such as solar thermal input and ambient temperature. It is shown that solar hybridization into an NGCC plant may give rise to a substantial benefit from a thermodynamic point of view. The work here also indicates that a significant solar contribution may be achieved in an ISCC plant, thus implying substantial fuel savings and environmental benefits.  相似文献   

15.
Afghanistan has a need for increased access to energy to enable development. In this paper we analyze the potential for large-scale grid-connected solar photovoltaic (PV) and wind power plants in two of Afghanistan's most populous provinces (Balkh and Herat) to meet a large fraction of growing electricity demand. The results presented here represent the first quantitative analysis of potential capacity factors and energy yields of power plants in the country using measured wind speed and typical solar radiation data. Variability of resources is also investigated by comparing temporal profiles with those of electricity demand, using residual load duration curves to determine penetration and curtailment levels for various demand scenarios. We show that solar PV and wind power plants in two provinces could achieve penetration levels of 65%–70% without significant curtailment, which in turn would mean less reliance on unpredictable and unstable power purchase agreements with neighboring countries, longer life of limited domestic fossil fuel resources, and lower imports of diesel fuel, thus avoiding rising costs and detrimental environmental impacts. Our results point to an alternative development pathway from that of previous recommendations for conventional thermal power plants, controversial hydroelectric projects, and a significant dependence on imported power.  相似文献   

16.
A review of energy storage technologies for wind power applications   总被引:1,自引:0,他引:1  
Due to the stochastic nature of wind, electric power generated by wind turbines is highly erratic and may affect both the power quality and the planning of power systems. Energy Storage Systems (ESSs) may play an important role in wind power applications by controlling wind power plant output and providing ancillary services to the power system and therefore, enabling an increased penetration of wind power in the system. This article deals with the review of several energy storage technologies for wind power applications. The main objectives of the article are the introduction of the operating principles, as well as the presentation of the main characteristics of energy storage technologies suitable for stationary applications, and the definition and discussion of potential ESS applications in wind power, according to an extensive literature review.  相似文献   

17.
While wind and solar have been the leading sources of renewable energy up to now, waves are increasingly being recognized as a viable source of power for coastal regions. This study analyzes integrating wave energy into the grid, in conjunction with wind and solar. The Pacific Northwest in the United States has a favorable mix of all three sources. Load and wind power series are obtained from government databases. Solar power is calculated from 12 sites over five states. Wave energy is calculated using buoy data, simulations of the ECMWF model, and power matrices for three types of wave energy converters. At the short horizons required for planning, the properties of the load and renewable energy are dissimilar. The load exhibits cycles at 24 h and seven days, seasonality and long-term trending. Solar power is dominated by the diurnal cycle and by seasonality, but also exhibits nonlinear variability due to cloud cover, atmospheric turbidity and precipitation. Wind power is dominated by large ramp events–irregular transitions between states of high and low power. Wave energy exhibits seasonal cycles and is generally smoother, although there are still some large transitions, particularly during winter months. Forecasting experiments are run over horizons of 1–4 h for the load and all three types of renewable energy. Waves are found to be more predictable than wind and solar. The forecast error at 1 h for the simulated wave farms is in the range of 5–7 percent, while the forecast errors for solar and wind are 17 and 22 percent. Geographic dispersal increases forecast accuracy. At the 1 h horizon, the forecast error for large-scale wave farms is 39–49 percent lower than at individual buoys. Grid integration costs are quantified by calculating balancing reserves. Waves show the lowest reserve costs, less than half wind and solar.  相似文献   

18.
This paper presents an experimental study of a standalone hybrid microgrid system. The latter is dedicated to remote area applications. The system is a compound that utilizes renewable sources that are Wind Generator (WG), Solar Array (SA), Fuel Cell (FC) and Energy Storage System (ESS) using a battery. The power electronic converters play a very important role in the system; they optimize the control and energy management techniques of the various sources. For wind and solar subsystem, the speed and Single Input Fuzzy Logic (SIFL) controllers are used respectively to harvest the maximum power point tracking (MPPT). To maintain a balance of energy in the hybrid system, an energy management strategy based on the battery state of charge (SOC) has been developed and implemented experimentally. The AC output voltage regulation was achieved using a Proportional Integral (PI) controller to supply a resistive load with constant amplitude and frequency. According to the obtained performances, it was concluded that the proposed system is very promising for potential applications in hybrid renewable energy management systems.  相似文献   

19.
Critical evaluation of solar chimney power plant performance   总被引:5,自引:0,他引:5  
This paper evaluates the influence of a recently developed convective heat transfer equation, more accurate turbine inlet loss coefficient, quality collector roof glass and various types of soil on the performance of a large scale solar chimney power plant. Results indicate that the new heat transfer equation reduces plant power output considerably. The effect of a more accurate turbine inlet loss coefficient is insignificant, while utilizing better quality glass enhances plant power production. Models employing Limestone and Sandstone soil produce virtually similar results to a Granite-based model. The plant collector height is found to differ from previously obtained optimal values.  相似文献   

20.
Simon Shun  Noor A. Ahmed   《Renewable Energy》2008,33(6):1392-1397
Wind and solar energy are currently used to power many building ventilation devices. Such devices rely exclusively on either solar or wind energy, which limits their usefulness. A low-cost hybrid ventilation device that utilizes both wind and solar energy as power sources was designed to overcome some of the shortcomings of these devices. Wind tunnel testing conducted at the aerodynamics laboratory of the University of New South Wales revealed that the hybrid device had improved operational and performance benefits compared with conventional commercial roof top ventilators, particularly at zero to low wind speeds. This represents a significant step forward and will have an immediate impact in promoting the use of clean energy for the purposes of building ventilation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号