1.
We have fabricated label-free protein biosensors based on aptamer-modified carbon nanotube field-effect transistors (CNT-FETs) for the detection of immunoglobulin E (IgE). After the covalent immobilization of 5'-amino-modified 45-mer aptamers on the CNT channels, the electrical properties of the CNT-FETs were monitored in real time. The introduction of target IgE at various concentrations caused a sharp decrease in the source-drain current, and a gradual saturation was observed at lower concentrations. The amount of the net source-drain current before and after IgE introduction on the aptamer-modified CNT-FETs increased as a function of IgE concentration. The detection limit for IgE was determined as 250 pM. We have also prepared CNT-FET biosensors using a monoclonal antibody against IgE (IgE-mAb). The electrical properties of the aptamer- and antibody-modified CNT-FETs were compared. The performance of aptamer-modified CNT-FETs provided better results than the ones obtained using IgE-mAb-modified CNT-FETs under similar conditions. Thus, we suggest that the aptamer-modified CNT-FETs are promising candidates for the development of label-free protein biosensors.  相似文献   

2.
Label-free electrochemical detection for aptamer-based array electrodes   总被引:9,自引:0,他引:9  
Xu D  Xu D  Yu X  Liu Z  He W  Ma Z 《Analytical chemistry》2005,77(16):5107-5113
An electrochemical impedance spectroscopy method of detection for aptamer-based array electrodes is reported in which the binding of aptamers immobilized on gold electrodes leads to impedance changes associated with target protein binding events. Human IgE was used as a model target protein and incubated with the aptamer-based array consisting of single-stranded DNA containing a hairpin loop. To increase the binding efficiency for proteins, a hybrid modified layer containing aptamers and cysteamine was fabricated on the photolithographic gold surface through molecular self-assembly. Atomic force microscopy analysis demonstrated that human IgE could be specifically captured by the aptamer and stand well above the self-assembled monolayer (SAM) surface. Compared to immunosensing methods using anti-human IgE antibody as the recognition element, impedance spectroscopy detection could provide higher sensitivity and better selectivity for aptamer-modified electrodes. The results of this method show good correlation for human IgE in the range of 2.5-100 nM. A detection limit of 0.1 nM (5 fmol in a 50-microL sample) was obtained, and an average of the relative standard deviation was <10%. The method herein describes the first label-free detection for arrayed electrodes utilizing electrochemical impedance spectroscopy.  相似文献   

3.
4.
Aptamer-enhanced laser desorption/ionization for affinity mass spectrometry   总被引:5,自引:0,他引:5  
Dick LW  McGown LB 《Analytical chemistry》2004,76(11):3037-3041
The thrombin-binding DNA aptamer was used for affinity capture of thrombin in MALDI-TOF-MS. The aptamer was covalently attached to the surface of a glass slide that served as the MALDI surface. Results show that thrombin is retained at the aptamer-modified surface while nonspecific proteins, such as albumin, are removed by rinsing with buffer. Upon application of the low-pH MALDI matrix, the G-quartet structure of the aptamer unfolds, releasing the captured thrombin. Following TOF-MS analysis, residual matrix and protein can be washed from the surface, and buffer can be applied to refold the aptamers, allowing the surface to be reused. Selective capture of thrombin from mixtures of thrombin and albumin and of thrombin and prothrombin from human plasma was demonstrated. This simple approach to affinity capture, isolation, and detection holds potential for analysis, sensing, purification, and preconcentration of proteins in biological fluids.  相似文献   

5.
Zhao Q  Li XF  Le XC 《Analytical chemistry》2008,80(10):3915-3920
A capillary chromatography technique was developed for the separation and detection of proteins, taking advantage of the specific affinity of aptamers and the porous property of the monolith. A biotinylated DNA aptamer targeting cytochrome c was successfully immobilized on a streptavidin-modified polymer monolithic capillary column. The aptamer, having a G-quartet structure, could bind to both cytochrome c and thrombin, enabling the separation of these proteins from each other and from the unretained proteins. Elution of strongly bound proteins was achieved by increasing the ionic strength of the mobile phase. The following proteins were tested using the aptamer affinity monolithic columns: human immunoglobulin G (IgG), hemoglobin, transferrin, human serum albumin, cytochrome c, and thrombin. Determination of cytochrome c and thrombin spiked into dilute serum samples showed no interference from the serum matrix. The benefit of porous properties of the affinity monolithic column was demonstrated by selective capture and preconcentration of thrombin at low ionic strength and subsequent rapid elution at high ionic strength. The combination of the polymer monolithic column and the aptamer affinities makes the aptamer-modified monolithic columns useful for protein detection and separation.  相似文献   

6.
In this study, we demonstrated the aptamer-based biosensor (apta-biosensor) using CNT-FET devices for label free detection of allergy diagnosis by IgE detection. In order to detect the IgE, two kinds of receptor (monoclonal IgE antibody and anti-IgE aptamer)-modified CNT-FET devices were fabricated. The binding event of the target IgE onto receptors was detected by monitoring the gating effect caused by the charges of the target proteins. Since the CNT-FET biosensors were used in buffer solution, it was crucial to use small-size receptors like aptamers than whole antibodies so that the charged target IgE could approach the CNT surface within the Debye length distance to give a large gating effect. The results show that CNT-FET biosensors using monoclonal IgE antibody had very low sensitivity (minimum detectable level 1000 ng/mL), while those based on anti-IgE aptamer could detect 50 ng/mL. Moreover, the aptamer-modified CNT-FET herein could successfully block non-target proteins and could selectively detect the target protein in an environment similar to human serum electrolyte. Therefore, aptamer-based CNT-FET devices enable the production of label-free ultrasensitive electronic biosensors to detect clinically important biomarkers for disease diagnosis.  相似文献   

7.
Piezoelectric-excited, millimeter-sized cantilever (PEMC) sensors having high-mode resonance near 1 MHz are shown to exhibit mass change sensitivity of 1-300 ag/Hz. Gold-coated PEMC sensors immobilized with 15-mer single-stranded DNA (ssDNA) were exposed to 10-mer complementary strands at concentrations of 1 fM, 1 pM, and 1 microM, both separately and sequentially at 0.6 mL/min in a sample flow cell housing the sensor. Decrease in resonance frequency occurred as complementary strands hybridized to the immobilized probe DNA on the sensor surface. Hybridization in three background matrixes--buffer, buffer containing 10,000 times higher noncomplementary strands, and 50% human plasma--were successfully tested. Sensor hybridization responses to 1 fM, 1 pM, and 1 microM complementary strand were nearly the same in magnitude in all three matrixes, but the hybridization rates were different. In each case, the sensor detected the presence of 2 amol of complementary 10-mer strand. The extent of hybridization calculated from resonance frequency change did not decrease in serum. The findings suggest ssDNA can be detected at 2 amol without a sample preparation step and without the use of labeled reagents.  相似文献   

8.
Liu Y  Yan J  Howland MC  Kwa T  Revzin A 《Analytical chemistry》2011,83(21):8286-8292
We report the development of a microdevice for detecting local interferon gamma (IFN-γ) release from primary human leukocytes in real time. Our microdevice makes use of miniature aptamer-modified electrodes integrated with microfluidics to monitor cellular production of IFN-γ. The aptamer species consists of a DNA hairpin molecule with thiol groups on the 3'-end for self-assembly onto Au electrodes. A redox reporter is covalently attached at the 5'-end for electrochemical sensing. This aptasensor has excellent sensitivity for IFN-γ (<60 pM detection limit) and responds to the target analyte in real time without additional washing or labeling steps. Aptamer-functionalized electrode arrays are fabricated on glass slides containing poly(ethylene glycol) (PEG) hydrogel patterns designed to expose glass regions adjacent to electrodes while protecting the remainder of the surface from nonspecific adsorption. The micropatterned substrates are integrated with PDMS microfluidic channels and incubated with T-cell-specific antibodies (Ab) (anti-CD4). Upon injection of blood, leukocytes are bound to Ab-modified glass regions in proximity to aptasensors. Cytokine release from captured cells is triggered by mitogenic activation and detected at the aptamer-modified electrodes using square wave voltammetry (SWV). The IFN-γ signal is monitored in real time with signal appearing as early as 15 min poststimulation from as few as 90 T cells. The observed IFN-γ release profiles are used to calculate an initial IFN-γ production rate of 0.0079 pg cell(-1) h(-1) upon activation. The work described here represents an important step toward development of aptasensors for immune cell analysis and blood-based diagnostics.  相似文献   

9.
The ability to detect sub-nanomolar concentrations of ricin using fluorescently tagged RNA aptamers is demonstrated. Aptamers rival the specificity of antibodies and have the power to simplify immunoassays using capillary electrophoresis. Under nonequilibrium conditions, a dissociation constant, Kd, of 134 nM has been monitored between the RNA aptamer and ricin A-chain. With use of this free-solution assay, the detection of 500 pM (approximately 14 ng/mL) or 7.1 amol of ricin is demonstrated. The presence of interfering proteins such as bovine serum albumin and casein do not inhibit this interaction at sub-nanomolar concentrations. When spiked with RNAse A, ricin can still be detected down to 1 nM concentrations despite severe aptamer degradation. This approach offers a promising method for the rapid, selective, and sensitive detection of biowarfare agents.  相似文献   

10.
FITC-labeled peptide (Pep-FITC) containing the cleavage site of matrix metalloproteinase-9 (MMP9) was non-covalently or covalently linked to graphene oxide (GO) to form non-covalent or covalent nanoprobes (nGO/Pep-FITC and nGO-Pep-FITC) for MMP9 detection. nGO-Pep-FITC was prepared by formation of amide bonds between the carboxyl groups of c-nGO and the amine groups on Pep-FITC with the addition of 1-ethyl-3-(dimethylaminopropyl)-carbodiimide (EDC). Pep-FITC was physically adsorbed onto the surface of c-nGO through π-π stacking and electrostatic interactions to produce nGO/Pep-FITC. Both nGO/Pep-FITC and nGO-Pep-FITC exhibited good selectivity for MMP9 detection. nGO/Pep-FITC and nGO-Pep-FITC showed 29.61 and 32.53 pM of detection limits for MMP9, respectively. nGO-Pep-FITC was much more resistant to bovine serum albumin (BSA) than nGO/Pep-FITC, thus may be applicable to analyze clinical samples especially containing proteins.  相似文献   

11.
Two mycocardial infarction biomarkers, myoglobin (MG) and cardiac troponin I (cTnI), were quantified at biological levels and in undiluted serum without sample pretreatment using surface plasmon resonance (SPR) sensors. To achieve detection of biomarkers in undiluted serum (72 mg/mL total protein concentration), minimization of the nonspecific signal from the serum protein was achieved by immobilizing the antibody for the biomarkers on an N-hydroxysuccinimide activated 16-mercaptohexadecanoic acid self-assembled monolayer. This monolayer reduces the nonspecific signal from serum proteins in such a manner that short exposure of the sensor to serum prior to analysis prevents any further nonspecific adsorption during analysis. Thus, sensing of MG and cTnI was achieved on the basis of the difference between signals from the active sensor and a reference sensor that captured background interference. This resulted in direct measurement of these biomarkers in undiluted serum. Detection limits for both markers were below 1 ng/mL, which is below the threshold needed to detect myocardial infarction. Detecting biomarkers in the low ng/mL range without signal amplification in such a complex matrix as serum corresponds to a selectivity of 108. The root-mean-square-error (RMSE) of calibration was below 2 ng/mL.  相似文献   

12.
Li H  Qiang W  Vuki M  Xu D  Chen HY 《Analytical chemistry》2011,83(23):8945-8952
An ultrasensitive protein assay method was developed based on silver nanoparticle (AgNP) hybrid probes and metal-enhanced fluorescence. Two aptamer based silver nanoparticles, Aptamer/Oligomer-A/Cy3-modified AgNPs (Tag-A) and Aptamer/Oligomer-B/Cy3-modified AgNPs (Tag-B) were hybridized to form a silver nanoparticle aggregate that produced a red shift and broadening of the Localized Surface Plasmon Resonance (LSPR) peak. The enhanced fluorescence resulted from the increased content of Cy3 molecules and their emission resonance coupled to the broadened localized surface plasmon (LSP) of AgNP aggregate. The separation distance between Cy3 and AgNPs was 8 nm which was the most optimal for metal enhanced fluorescence and the separation distance between adjacent AgNPs was about 16 nm and this was controlled by the lengths of oligomer-A and oligomer-B. The protein array was prepared by covalently immobilizing capture antibodies on aldehyde-coated slide. After addition of protein IgE sample, two kinds of aptamer-modified AgNPs (Tag-A and Tag-B) were employed to specifically recognize IgE and form the AgNP aggregate on the arrays based on their hybridization. The detection property of the aptamer-modified AgNP aggregate was compared to two other modified aptamer-based probes, aptamer-modified Cy3 and Tag-A. The modified AgNP hybrid probe (Tag-A and Tag-B) showed remarkable superiority in both sensitivity and detection limit due to the formed AgNP aggregate. The new hybrid probe also produced a wider linear range from 0.49 to 1000 ng/mL with the detection limit reduced to 40 pg/mL (211 fM). The presented method showed that the newly designed strategy of combining aptamer-based nanomaterials to form aggregates results in a highly sensitive optical detection method based on localized surface plasmon.  相似文献   

13.
Wang J  Li J  Baca AJ  Hu J  Zhou F  Yan W  Pang DW 《Analytical chemistry》2003,75(15):3941-3945
Gold nanoparticle/streptavidin conjugates covered with 6-ferrocenylhexanethiol were attached onto a biotinylated DNA detection probe of a sandwich DNA complex. Due to the elasticity of the DNA strands, the ferrocene caps on gold nanoparticle/streptavidin conjugates are positioned in close proximity to the underlying electrode modified with a mixed DNA capture probe/hexanethiol self-assembled monolayer and can undergo reversible electron-transfer reactions. A detection level, down to 2.0 pM (10 amol for the 5 microL of sample needed) for oligodeoxynucleotide samples was obtained. The amplification of the voltammetric signals was attributed to the attachment of a large number of redox (ferrocene) markers per DNA duplex formed. The ferrocene oxidation current increased with the target concentration and began to level off at a target concentration of 10 nM. An Excellent linearity was found within the range between 6.9 and 150.0 pM and reasonable relative standard deviations (between 3.0 and 13.0%) were obtained. The amenability of this method to the analyses of polynucleotides (i.e., PCR products of the pre-S gene of hepatitis B virus in serum samples) was also demonstrated. The method is shown to be simple, selective, reproducible, and cost-effective and does not require labeling of the DNA targets.  相似文献   

14.
Huang YF  Chang HT 《Analytical chemistry》2007,79(13):4852-4859
This paper describes the use of aptamer-modified gold nanoparticles (Apt-AuNPs) as selective probes and AuNPs as the surface-assisted laser desorption/ionization (SALDI) matrixes for the determination of adenosine triphosphate (ATP) by mass spectrometry (MS). The aptamers were covalently attached to the surface of AuNPs to form Apt-AuNPs that provided selectivity toward ATP. However, Apt-AuNPs are less efficient laser desorption/ionization (LDI) matrixes when compared to AuNPs. By using Apt-AuNPs as selective probes and AuNPs as LDI matrixes, the MS approach provided the limit of detection (LOD) for ATP at a signal-to-noise ratio of 3 of 0.48 microM. When compared to conventional organic matrixes (e.g., 2,5-dihydroxybenzoic acid), AuNPs as LDI matrixes provide a number of advantages, including ease of preparation, selectivity, sensitivity, and repeatability. Sequential analysis of ATP and GSH in human cell lysates by SALDI with negative and positive MS modes, respectively, using Apt-AuNPs and AuNPs has been demonstrated. The present results demonstrate the practicality of the approach for monitoring the bioactivity of cells through determinations of the concentrations of ATP and GSH.  相似文献   

15.
Here, we describe the coordinated use of two antibodies with different affinities in a single immunoassay to extend the dynamic range and to enable detection of multiple analytes. The combination of dual antibodies was permitted with a flow-based assay at the antibody concentration below the dissociation constant, enabling affinity to govern the antibody-antigen binding. Both high and low affinity antibodies to estriol were used in combination to extend the range. The binding of each antibody was mutually independent and individually occurred over concentration ranges of 10 pM(-1) nM and 100 pM(-1) microM. The wide dynamic range of 10 pM(-1) microM was thus achieved as summation of the proportional signals to the total binding. When a combination of antibodies toward different antigens was used, it effectively detected multiple analytes within a mixture. In simultaneous analysis of a mixture of estradiol and estriol, the total signal was the sum of the binding signals from anti-estradiol and anti-estriol antibodies. In a further refinement, the individual antibodies were flowed through the flow cell sequentially, allowing the quantification of each binding signal within the combination. With this sequential format, measurement of the individual hormones in the range of 1.6 pM(-1) nM was shown. Furthermore, the same flow format was successfully applied to assay estriol and estradiol hormones in mixtures of six related compounds.  相似文献   

16.
Early detection of cancer is vital for the successful treatment of the disease. Hence, a rapid and sensitive diagnosis is essential before the cancer is spread out to the other body organs. Here we describe the development of a point-of-care immunosensor for the detection of the cancer biomarker (total prostate-specific antigen, tPSA) using surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) sensor platforms in human serum samples. K(D) of the antibody used toward PSA was calculated as 9.46 × 10(-10) M, indicating high affinity of the antibody used in developing the assay. By performing a sandwich assay using antibody-modified nanoparticles concentrations of 2.3 ng mL(-1) (Au, 20 nm) and 0.29 ng mL(-1) (8.5 pM) (Au, 40 nm) tPSA in 75% human serum were detected using the developed assay on an SPR sensor chip. The SPR sensor results were found to be comparable to that achieved using a QCM sensor platform, indicating that both systems can be applied for disease biomarkers screening. The clinical applicability of the developed immunoassay can therefore be successfully applied to patient's serum samples. This demonstrates the high potential of the developed sensor devices as platforms for clinical prostate cancer diagnosis and prognosis.  相似文献   

17.
In this study, we prepared surface plasmon resonance (SPR) sensor using the molecular imprinting technique for myoglobin detection in human serum. For this purpose, we synthesized myoglobin imprinted poly(hydroxyethyl methacrylate-N-methacryloyl-l-tryptophan methyl ester) [poly(HEMA-MATrp)] nanofilm on the surface of SPR sensor. We also synthesized non-imprinted poly(HEMA-MATrp) nanofilm without myoglobin for the control experiments. The SPR sensor was characterized with contact angle measurements, atomic force microscopy, X-ray photoelectron spectroscopy, and ellipsometry. We investigated the effectiveness of the sensor using the SPR system. We evaluated the ability of SPR sensor to sense myoglobin with myoglobin solutions (pH 7.4, phosphate buffer) in different concentration range and in the serum taken from a patient with acute myocardial infarction. We found that the Langmuir adsorption model was the most suitable for the sensor system. The detection limit was 87.6 ng/mL. In order to show the selectivity of the SPR sensor, we investigated the competitive detection of myoglobin, lysozyme, cytochrome c and bovine serum albumin. The results showed that the SPR sensor has high selectivity and sensitivity for myoglobin.  相似文献   

18.
We describe here a new strategy for isolating target proteins from complex biological samples based on an aptamer-modified self-propelled microtube engine. For this purpose, a thiolated thrombin or a mixed thrombin-ATP aptamer (prehybridized with a thiolated short DNA) was coassembled with mercaptohexanol onto the gold surface of these microtube engines. The rapid movement of the aptamer-modified microtransporter resulted in highly selective and rapid capture of the target thrombin, with an effective discrimination against a large excess of nontarget proteins. Release of the captured thrombin can be triggered by the addition of ATP that can bind and displace the immobilized mixed thrombin-ATP aptamer in 20 min. The rapid loading and unloading abilities demonstrated by these selective microtransporters are illustrated in complex matrixes such as human serum and plasma. The new motion-driven protein isolation platform represents a new approach in bioanalytical chemistry based on active transport of proteins and offers considerable promise for diverse diagnostic applications.  相似文献   

19.
Online preconcentration of human serum albumin (HSA) and its immunocomplex with a monoclonal antibody by on-chip transient isotachophoresis is reported. An 800-fold signal enhancement was achieved following the preconcentration on standard cross-channel microchips made of poly (methyl methacrylate). Sample injection, preconcentration, and separation were done continuously and controlled solely by a sequential voltage switching program. The preconcentration was followed by on-chip nondenaturing gel electrophoresis in methylcellulose solution. The method was applied to microchip electrophoresis immunoassay of HSA. Baseline separation of HSA and its immunocomplex was achieved in 25 s in the first 1 cm of the microchannel. In a direct immunoassay, the minimum detectable concentration of fluorescent labeled HSA by laser-induced fluorescence detection was 7.5 pM.  相似文献   

20.
Fused-silica capillary LC columns (25-microm i.d.) with 3-microm-i.d. integrated electrospray emitters interfaced to a quadrupole ion trap mass spectrometer were evaluated for high-sensitivity LC-MS2. Column preparation involved constructing frits by in situ photopolymerization of glycidyl methacrylate and trimethylolpropane trimethacrylate, preparing the electrospray emitter by pulling the column outlet to a fine tip with a CO2 laser puller, and slurry-packing the column with 5-microm reversed-phase particles. Large-volume injections were facilitated by an automated two-pump system that allowed high-flow rates for sample loading and low-flow rates for elution. Small electrospray emitters, low elution flow rates, and optimization of gradient steepness allowed a detection limit of 4 amol, corresponding to 2 pM for 1.8 microL injected on-column, for a mixture of peptides dissolved in artificial cerebral spinal fluid. The system was coupled on-line to microdialysis sampling and was used to monitor and discover endogenous neuropeptides from the globus pallidus of anesthetized male Sprague-Dawley rats. Time-segmented MS2 scans enabled simultaneous monitoring of Met-enkephalin, Leu-enkephalin, and unknown peptides. Basal dialysate levels of Met-enkephalin and Leu-enkephalin were 60 +/- 30 and 70 +/- 20 pM while K+-stimulated levels were 1,900 +/- 500 and 1,300 +/- 300 pM, respectively (n = 7). Data-dependent and time-segmented MS2 scans revealed several unknown peptides that were present in dialysate. One of the unknowns was identified as peptide I(1-10) (SPQLEDEAKE), a novel product of preproenkephalin A processing, using MS2, MS3, and database searching.  相似文献   