首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Direct steam generation (DSG) is the process by which steam is directly produced in parabolic trough fields and supplied to a power block. This process simplifies parabolic trough plants and improves cost effectiveness by increasing the permissible temperature of the working fluid. Similar to all solar‐based technologies, thermal energy storage is needed to overcome the intermittent nature of solar. In the present work, an innovative DSG‐based parabolic trough collector (PTC) plant hybridized with a biomass boiler is proposed and analyzed in detail. Two additional configurations comprising indirect steam generation PTC plants were also analyzed to compare their energy and exergy performance. To consider a wide range of operation, the share of biomass input to the hybridized system is varied. Energy and exergy analyses of DSG are conducted and compared with an existing indirect steam generation PTC power plants such as Andasol. The analyses are conducted on a 50 MW regenerative reheat Rankine cycle. The results obtained indicate that the proposed DSG‐based PTC plant is able to increase the overall system efficiency by 3% in comparison with indirect steam generation when linked to a biomass boiler that supplies 50% of the energy.  相似文献   

2.
Parabolic trough power plants are currently the most commercially applied systems for CSP power generation. To improve their cost-effectiveness, one focus of industry and research is the development of processes with other heat transfer fluids than the currently used synthetic oil. One option is the utilization of water/steam in the solar field, the so-called direct steam generation (DSG).Several previous studies promoted the economic potential of DSG technology (Eck et al., 2008b, Price et al., 2002, Zarza, 2002). Analyses’ results showed that live steam parameters of up to 500 °C and 120 bars are most promising and could lead to a reduction of the levelized electricity cost (LEC) of about 11% (Feldhoff et al., 2010). However, all of these studies only considered plants without thermal energy storage (TES).Therefore, a system analysis including integrated TES was performed by Flagsol GmbH and DLR together with Solar Millennium AG, Schott CSP GmbH and Senior Berghöfer GmbH, all Germany. Two types of plants are analyzed and compared in detail: a power plant with synthetic oil and a DSG power plant. The design of the synthetic oil plant is very similar to the Spanish Andasol plants (Solar Millennium, 2009) and includes a molten salt two-tank storage system. The DSG plant has main steam parameters of 500 °C and 112 bars and uses phase change material (PCM) for the latent and molten salt for the sensible part of the TES system. To enable comparability, both plants share the same gross electric turbine capacity of 100 MWel, the same TES capacity of 9 h of full load equivalent and the same solar multiple of the collector field of about two.This paper describes and compares both plants’ design, performance and investment. Based on these results, the LEC are calculated and the DSG plant’s potential is evaluated. One key finding is that with currently proposed DSG storage costs, the LEC of a DSG plant could be higher than those of a synthetic oil plant. When considering a plant without TES on the other hand, the DSG system could reduce the LEC. This underlines the large influence of TES and the still needed effort in the development of a commercial storage system for DSG.  相似文献   

3.
Parabolic trough power plants are currently the most commercial systems for electricity generation. In this study, a transient numerical simulation of a solar power plant was developed by using direct steam generation (DSG) technology. In this system, condensate water from a Rankine cycle is pumped directly to solar parabolic trough collectors. The pressurized water is heated and evaporated before being superheated inside the solar collectors and directed back to the steam turbines, where the Rankine cycle is a reheated‐regenerative cycle. The plant performance with saturated steam production is compared with the performance of a superheated plant. A mathematical model of each system component is presented, with the solar power cycle modeled by the TRNSYS‐17 simulation program. Annual transient performance, including plant power and efficiency, is presented for both plants. As expected, the power of the superheated plant outperforms the saturated plant by approximately 45%, whereas the efficiency decreases by approximately 10%. Furthermore, the power of such plants is considerably improved under the weather of Makkah, 22.4°N, and it is approximately 40 MW for both the spring and autumn seasons. The annual generated energy is approximately 8062 MWh. The levelized electricity cost (LEC) was estimated for both the DSG and the corresponding synthetic oil plants. The DSG plant has an approximately 3% higher LEC than a synthetic oil plant with heat storage and an approximately 11.2% lower LEC than an oil plant if the plant has no storage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
Global concern for depleting fossil fuel reserves have been compelling for evolving power generation options using renewable energy sources. The solar energy happens to be a potential source for running the power plants among renewable energy sources. Integrated Solar Combined Cycle(ISCC) power plants have gained popularity among the thermal power plants. Traditional ISCC power plants use Direct Steam Generation(DSG) approach. However, with the DSG method, the ISCC plant’s overall thermal efficiency does not increase significantly due to variations in the availability of solar energy. Thermal Energy Storage(TES) systems when integrated into the solar cycle can address such issues related to energy efficiency, process flexibility, reducing intermittency during non-solar hours. This review work focuses and discusses the developments in various components of the ISCC system including its major cycles and related parameters. The main focus is on CSP technologies, Heat Transfer Fluid(HTF), and Phase Change Material(PCM) used for thermal energy storage. Further, study includes heat enhancement methods with HTF and latent heat storage system. This study will be beneficial to the power plant professionals intending to modify the solar-based Combined Cycle Power Plant(CCPP) and to retrofit the existing Natural Gas Combined Cycle(NGCC) plant with the advanced solar cycle.  相似文献   

5.
Direct steam generation (DSG) in parabolic trough collectors causes an increase to competitiveness of solar thermal power plants (STPP) by substitution of oil with direct steam generation that results in lower investment and operating costs. In this study the integrated solar combined cycle system with DSG technology is introduced and techno-economic assessment of this plant is reported compared with two conventional cases. Three considered cases are: an integrated solar combined cycle system with DSG technology (ISCCS-DSG), a solar electric generating system (SEGS), and an integrated solar combined cycle system with HTF (heat transfer fluid) technology (ISCCS-HTF).This study shows that levelized energy cost (LEC) for the ISCCS-DSG is lower than the two other cases due to reducing O&M costs and also due to increasing the heat to electricity net efficiency of the power plant. Among the three STPPs, SEGS has the lowest CO2 emissions, but it will operate during daytime only.  相似文献   

6.
Solar energy is an attractive renewable energy source because the sun's energy is plentiful and carbon-free. However, solar energy is intermittent and not suitable for base load electricity generation without an energy backup system. Concentrated solar power (CSP) is unique among other renewable energy options because it can approach base load generation with molten salt thermal energy storage (TES). This paper describes the development of an engineering economic model that directly compares the performance, cost, and profit of a 110-MW parabolic trough CSP plant operating with a TES system, natural gas-fired backup system, and no backup system. Model results are presented for 0–12 h backup capacities with and without current U.S. subsidies. TES increased the annual capacity factor from around 30% with no backup to up to 55% with 12 h of storage when the solar field area was selected to provide the lowest levelized cost of energy (LCOE). Using TES instead of a natural gas-fired heat transfer fluid heater (NG) increased total plant capital costs but decreased annual operation and maintenance costs. These three effects led to an increase in the LCOE for PT plants with TES and NG backup compared with no backup. LCOE increased with increasing backup capacity for plants with TES and NG backup. For small backup capacities (1–4 h), plants with TES had slightly lower LCOE values than plants with NG backup. For larger backup capacities (5–12 h), plants with TES had slightly higher LCOE values than plants with NG backup. At these costs, current U.S. federal tax incentives were not sufficient to make PT profitable in a market with variable electricity pricing. Current U.S. incentives combined with a fixed electricity price of $200/MWh made PT plants with larger backup capacities more profitable than PT plants with no backup or with smaller backup capacities. In the absence of incentives, a carbon price of $100–$160/tonne CO2eq would be required for these PT plants to compete with new coal-fired power plants in the U.S. If the long-term goal is to increase renewable base load electricity generation, additional incentives are needed to encourage new CSP plants to use thermal energy storage in the U.S.  相似文献   

7.
This study analyzes a renewable energy‐driven innovative multigeneration system, in which wind and solar energy sources are utilized in an efficient way to generate several useful commodities such as hydrogen, oxygen, desalted water, space cooling, and space heating along with electricity. A 1‐km2 heliostat field is considered to concentrate the solar light onto a spectrum splitter, where the light spectrum is separated into two portions as reflected and transmitted to be used as the energy source in the concentrated solar power (CSP) and concentrated photovoltaics (CPV) receivers, respectively. As such, CSP and CPV systems are integrated. Wind energy is proposed for generating electricity (146 MW) or thermal energy (138 MW) to compensate the energy need of the multigeneration system when there is insufficient solar energy. In addition, multiple commodities, 46 MW of electricity, 12 m3/h of desalted water, and 69 MW of cooling, are generated using the Rankine cycle and the rejected heat from its condenser. Further, the heat generated on CPV cells is recovered for efficient photovoltaic conversion and utilized in the space heating (34 MW) and proton exchange membrane (PEM) electrolyzer (239 kg/h) for hydrogen production. The energy and exergy efficiencies of the overall system are calculated as 61.3% and 47.8%, respectively. The exergy destruction rates of the main components are presented to identify the potential improvements of the system. Finally, parametric studies are performed to analyze the effect of changing parameters on the exergy destruction rates, production rates, and efficiencies.  相似文献   

8.
Dye‐sensitized solar cell (DSSC) attracts immense interest in the last few decades due to its various attractive features such as low production cost, ease of fabrication and relatively high conversion efficiency, which make it a strong competitor to the conventional silicon‐based solar cell. In DSSC, photo‐anode performs two important functions, viz. governs the collection and transportation of photo‐excited electrons from dye to external circuit as well as acts as a scaffold layer for dye adsorption. The photo‐anode usually consists of wide band gap semiconducting metal oxides such as titanium dioxide (TiO2) and zinc oxide (ZnO) deposited on the transparent conducting oxide substrates. The morphology and composition of the semiconductor oxides have significant impact on the DSSC photovoltaic performance. Therefore, enormous research efforts have been undertaken to investigate the influences of photo‐anode modifications on DSSC performance. The modifications can be classified into three categories, namely interfacial modification through the introduction of blocking and scattering layer, doping with non‐metallic anions and metallic cations and replacing the conventional mesoporous semiconducting metal oxide films with one‐dimensional or two‐dimensional nanostructures. In the present review, the previously mentioned modifications on photo‐anode are summarized based on the recent findings, with particular emphasis given to published works for the past 5 years. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

9.
The combination of desalination technology into concentrating solar power (CSP) plants needs to be considered for the planned installation of CSP plants in arid regions. There are interesting synergies between the two technologies, like the possibility of substituting the condenser of the power cycle for a thermal desalination unit. This paper presents a thermodynamic evaluation of different configurations for coupling parabolic-trough (PT) solar power plants and desalination facilities in a dry location representing the Middle East and North Africa (MENA) region. The integration of a low-temperature multi-effect distillation (LT-MED) plant fed by the steam at the outlet of the turbine replacing the condenser of the power cycle has been simulated and compared with the combination of CSP with a reverse osmosis (RO) plant. Furthermore, an additional novel concept of concentrating solar power and desalination (CSP+D) has been evaluated: a LT-MED powered by the steam obtained from a thermal vapour compressor (TVC) using the exhaust steam of the CSP plant as entrained vapour and steam extracted from the turbine as the motive vapour of the ejector. This new concept (LT-MED-TVC) has been analyzed and compared with the others, evaluating its optimization for the integration into a CSP plant by considering different extractions of the turbine.  相似文献   

10.
Sun is an inexhaustible source of energy capable of fulfilling all the energy needs of humankind. The energy from the sun can be converted into electricity or used directly. Electricity can be generated from solar energy either directly using photovoltaic (PV) cells or indirectly using concentrated solar power (CSP) technology. Progress has been made to raise the efficiency of the PV solar cells that can now reach up to approximately 34.1% in multi‐junction PV cells. Electricity generation from concentrated solar technologies has a promising future as well, especially the CSP, because of its high capacity, efficiency, and energy storage capability. Solar energy also has direct application in agriculture primarily for water treatment and irrigation. Solar energy is being used to power the vehicles and for domestic purposes such as space heating and cooking. The most exciting possibility for solar energy is satellite power station that will be transmitting electrical energy from the solar panels in space to Earth via microwave beams. Solar energy has a bright future because of the technological advancement in this field and its environment‐friendly nature. The biggest challenge however facing the solar energy future is its unavailability all‐round the year, coupled with its high capital cost and scarcity of the materials for PV cells. These challenges can be met by developing an efficient energy storage system and developing cheap, efficient, and abundant PV solar cells. This article discusses the solar energy system as a whole and provides a comprehensive review on the direct and the indirect ways to produce electricity from solar energy and the direct uses of solar energy. The state‐of‐the‐art procedures being employed for PV characterization and performance rating have been summarized . Moreover, the technical, economic, environmental, and storage‐related challenges are discussed with possible solutions. Furthermore, a comprehensive list of future potential research directions in the field of direct and indirect electricity generation from solar energy is proposed.  相似文献   

11.
Selecting a site that meets the technical requirements for a concentrating solar power plant (CSP) is a very critical exercise. This paper points out crucial factors and provides guidelines regarding the selection of suitable sites. It especially focuses on Sahelian countries which have their own climatic peculiarities. These countries, characterized by low access to electricity, are well endowed in solar resources. They are potentially good locations for concentrating solar power plants since their mean daily solar radiation exceeds 5.5 kWh/m2. CSP presents therefore, a good opportunity for them to increase in a sustainable manner, their energy supply. The guidelines developed in this paper are applied to Burkina Faso as a case study.  相似文献   

12.
Solar radiation can be converted into electrical energy and generate electric power that can be utilized in multiple ways. The technological improvements have provided enormous solutions to the mankind for utilizing the solar energy although photovoltaic's (PV) by consuming sunlight. Photovoltaic is popularly known by the process of converting light to electricity. The current estimated growth by producing global power around 368 GW in 2017 and projecting 3000 to 10 000 GW by 2030. Looking at all the available solar cells, it has been observed that the dye‐sensitized solar cell (DSSC) when compared to mono‐Si or poly‐Si has been effective in its performance and also reduces production cost to a great extent. The power conversion efficiency (PCE) of DSSC has reached to a better extent and been discussed in the paper. There are other mechanisms through which the efficiency can be improved like applying the antireflection coating. Reflection is a usual phenomenon that happens when light incident from one medium to another varies in refractive index. This reflection is one of the important reasons for the loss of power in the PV Cell. So to improve the PCE, the Mono‐Si or DSSC PV Cells can be applied with a thin film antireflection coating by the nanocomposite film consisting of single‐ or multi‐wall carbon nanotubes with TiO2 and other efficient nanoparticles. This paper discusses on different kinds of nanocomposite materials, and their functionalities has been clearly given. Remarkable improvements have been recorded in the last 1 year by applying the antireflection coating; the PCE has further been increased enormously when compared to the uncoated solar cell for both DSSC and Mono‐Si PV cells.  相似文献   

13.
The effect on the cost of electricity from concentrating solar power (CSP) plants of the solar multiple, the capacity factor and the storage capacity is studied. The interplay among these factors can be used to search for a minimal-cost objective that can serve as a technical criterion to guide in the design of economic incentives for CSP plants. The probability-density function of irradiation is used in conjunction with screening models to evaluate the performance characteristics and costs of concentrating solar power plants. Two technologies have been analyzed in this study: parabolic-trough and tower plants. The results provide information to define the optimal operational range as a function of the desired objective. Thus, it is possible to derive a technical criterion for the design of CSP plants which optimizes the solar electricity produced and its generation cost. The methodology is applied to Spain, and the analysis of the results shows that a solar energy production of 37 kWh/m2/year for tower plants and 66 kWh/m2/year for parabolic-trough ones define the approximate optimal working conditions for the mean DNI in Spain.  相似文献   

14.
Dish‐Stirling concentrated solar power (DS‐CSP) system is a complex system for solar energy‐thermal‐electric conversion. The dish concentrator and cavity receiver are optical devices for collecting the solar energy in DS‐CSP system; to determine the geometric parameters of dish concentrator is one of the important steps for design and development of DS‐CSP system, because it directly affects the optical performance of the cavity receiver. In this paper, the effects of the geometric parameters of a dish concentrator including aperture radius, focal length, unfilled radius, and fan‐shaped unfilled angle on optical performance (ie, optical efficiency and flux distribution) of a cavity receiver were studied. Furthermore, the influence of the receiver‐window radius of the cavity receiver and solar direct normal irradiance is also investigated. The cavity receiver is a novel structure that is equipped with a reflecting cone at bottom of the cavity to increases the optical efficiency of the cavity receiver. Moreover, a 2‐dimensional ray‐tracking program is developed to simulate the sunlight transmission path in DS‐CSP system, for helping understanding the effects mechanism of above parameters on optical performance of the cavity receiver. The analysis indicates that the optical efficiency of the cavity receiver with and without the reflecting cone is 89.88% and 85.70%, respectively, and former significantly increased 4.18% for 38 kW XEM‐Dish system. The uniformity factor of the flux distribution on the absorber surface decreases with the decreases of the rim angle of the dish concentrator, but the optical efficiency of the cavity receiver increases with the decreases of the rim angle and the increase amplitude becomes smaller and smaller when the rim angle range from 30° to 75°, So the optical efficiency and uniformity factor are conflicting performance index. Moreover, the unfilled radius has small effect on the optical efficiency, while the fan‐shaped unfilled angle and direct normal irradiance both not affect the optical efficiency. In addition, reducing the receiver‐window radius can improve the optical efficiency, but the effect is limited. This work could provide reference for design and optimization of the dish concentrator and establishing the foundation for further research on optical‐to‐thermal energy conversion.  相似文献   

15.
Portugal has a high potential for concentrated solar power and namely for atmospheric air volumetric central receiver systems (CRS). The solar multiple and storage capacity have a significant impact on the power plant levelized electricity cost (LEC) and their optimization and adequate control strategy can save significant capital for the investors. The optimized proposed volumetric central receiver system showed good performance and economical indicators.For Faro conditions, the best 4 MWe power plant configuration was obtained for a 1.25 solar multiple and a 2 h storage. Applying control strategy #1 (CS#1) the power plant LEC is 0.234 €/kWh with a capital investment (CAPEX) of € 22.3 million. The capital invested has an internal rate of return (IRR) of 9.8%, with a payback time of 14 years and a net present value (NPV) of € 7.9 million (considering an average annual inflation of 4%). In the case of better economical indicators, the power plant investment can have positive contours, with an NPV close to € 13 million (annual average inflation of 2%) and the payback shortened to 13 years.  相似文献   

16.
Ocean thermal energy conversion (OTEC) is an electric power generation method that utilizes temperature difference between the warm surface seawater and cold deep seawater of ocean. As potential sources of clean‐energy supply, OTEC power plants' viability has been investigated. However, The OTEC system has problems of low efficiency and high investment cost because the temperature difference between the surface and the deep sea is small and it has a long pipe line and high pumping cost for using cold deep water. Therefore, in this present study, the OTEC system is combined with a solar system. It evaluated the thermodynamic performance of Solar‐OTEC Convergence System for the simultaneous production with electric power and desalinated water. The performance analysis of Solar‐OTEC Convergence System was carried out as the fluid temperature, saturated temperature difference and pressure of flash evaporator under equivalent conditions. The results showed that the performance of solar‐open OTEC system is the highest at the flash evaporator pressure of 10 kPa. At this time, the system efficiency, electric power and desalination production enhancement ratios were approximately 3.9, 13.9 and 5.1 times higher than that of the base open OTEC system respectively. Also, the performance of solar‐hybrid OTEC system is the highest at the inflow fluid temperature of evaporator of 80 °C. The system efficiency, electric power and desalination production enhancement ratios were approximately 3.5, 3.5 and 14.5 times higher than that of the base hybrid OTEC system. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
The dye‐sensitized solar cell (DSSC) is a promising alternative for the Si solar cell due to its low‐cost and easy fabrication. As a novel conductive polymer, poly(3,4‐ethylenedioxythiophene) (PEDOT) has attracted much attention for DSSCs. In this review article, the progress of PEDOT‐based counter electrodes for DSSCs is presented. First, the properties and structure of PEDOT are briefly described, and its feasibility as a DSSC counter electrode is demonstrated. Then, the effect of various treatments on the electrical conductivity and catalytic activity of PEDOT as well as its stability is examined. Furthermore, efficient and low‐cost composite counter electrodes consisting of PEDOT and other materials are deeply discussed. Finally, an outlook for PEDOT counter electrodes is provided. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Intermittent nature of solar energy and solution strategies for steam methane reforming reaction powered by concentrated solar energy over Ni/mullite and Pd/CeO2/mullite catalysts were demonstrated. The solar concentration was achieved using a parabolic mirror with a 70 cm, delivering concentrated solar flux onto a focal area that is approximately 3 cm in diameter. The solar field tests conducted on monolithic catalyst support structures were compared with the laboratory scale measurements on powdered catalysts. Despite the fluctuations in solar irradiation, CH4 conversions higher than 90% could be obtained. Coke deposition was observed over the 15%Ni/Mullite monolith. On the 1%Pd/20%CeO2/Mullite monolith, the oxidative nature of the catalyst resulted in oxidation reactions with local temperatures exceeding 1700 °C, inferred through the melting point of mullite. Numerical simulations revealed temperature gradients as large as 500 °C, over the refractory monoliths.  相似文献   

19.
Hydrogen production can be achieved via combined concentrated photovoltaic (CPV) and concentrated solar power (CSP) in which concentrated radiation is spectrally split and then converted in a photovoltaic receiver and a thermal absorber. This study thus proposes an innovative solar process design integrating both thermal and quantum components of solar energy while providing a complete assessment of its global performance to demonstrate its practical interest. A stand-alone solar-to-hydrogen path was modeled and numerically simulated, which was both electrically and thermally supplied by a solar power generation unit to feed the electrolyzer power utilization unit with enhanced solar-to-hydrogen conversion efficiency. Following balance of plant (BoP), the heliostat field and cavity receiver were designed to match the entire system in which the receiver only intercepts a definite range of infrared wavelength while the rest is converted by separately insulated PV cells. Moreover, dichroic reflectors and optimum cutoff wavelength were applied to fulfill separate optimization and heat load reduction of each solar cell. Finally, the solid oxide electrolysis cell (SOEC) was designed to utilize the generated thermal and electrical power appropriately. In best case scenario, a solar-to-hydrogen conversion efficiency of 36.5% was achieved under 899 W/m2 direct normal irradiance (DNI) and 1000 suns concentration. The solar plant outputs at this operating point were 850 g/h H2 and 6754 g/h O2. Further improvement in efficiency can be achieved through alignment in regard to the site location and annual insolation variation.  相似文献   

20.
The thermal performance of two different schemes of solar‐assisted heat‐pump systems has been theoretically studied. In first scheme, the evaporator of the heat pump is taken directly as the solar collecting plate and always maintained at the ambient temperature. As there is no heat loss from the collecting plate, the thermal efficiency of the collector is high and equals the solar absorptivity of the collecting plate. As suggested, the heat‐pump evaporator of the second scheme is placed in a novel fresh water solar pond/tank with high efficiency. Since the evaporator operates at a relatively high temperature, the COP of the heat pump can be increased. The calculated results show that the COP of a solar‐assisted heat pump using the second scheme is considerably higher than that of the first scheme. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号