首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Osseointegration is a histometric process that occurs gradually over a period of time. The load that an implant is able to bear depends upon, among other parameters, the quality of the bone-implant contact. For 8 years the damping capacity of 1,182 Br?nemark implants inserted consecutively in 315 patients was measured using the Periotest method. The following clinical observations were made: (1) a relationship was found between implants with a specific Periotest value range that, at the moment of the transepithelial connection, were considered to be clinically stable, asymptomatic, and whose radiograph image was not radiolucent; (2) a relationship was found between clinically nonintegrated implants with a different Periotest value range; (3) variations in the Periotest value were related to the type of bone in which the implant was placed; (4) a small percentage of borderline implants with a Periotest value between the osseointegrated and the nonosseointegrated Periotest values was detected; (5) the percentage of secondary failures was related to an initial Periotest value corresponding to a borderline implant; (6) the healing time of each implant was individualized in accordance with the successively obtained Periotest value; (7) the load and the design of the prosthesis were individualized; (8) early detection of failing implants before fabrication of prostheses is possible; (9) communication was improved between the surgeon and the prosthodontist; and (10) variations in Periotest value were related to bone remodeling. The sensitivity of the principal clinical test in evaluating osseointegration is discussed regarding the moment of its application. The use of Periotest values as an initial success criteria of an implant is proposed.  相似文献   

2.
The objective of this study was to analyze the efficacy and correlation between clinical and histologic parameters used to evaluate oral implants. After extraction of the premolars and a healing time of 4 months in 16 Dutch goats, four Br?nemark implants were placed in the maxillary left and right premolar regions. After a healing time of 6 months, followed by another 4 months with the permucosal abutments, the goats were sacrificed and the jaws were block-resected. Before histologic preparation, long-cone radiographs were made and Periotest scores of the implants were recorded. Bone level measured histomorphometrically were found to be 0.85 mm more apically, compared to that measured radiologically (P = .001). Furthermore, statistically significant correlations (P > 0.2) were not found between the Periotest values of the calcium-phosphate-coated and uncoated implants for (1) the first thread in contact with bone, or (2) with the total number of threads in contact with bone. It was concluded that the radiologic data overscored the real marginal bone level around screw-shaped oral implants, and that the Periotest device is neither able to discriminate between the first thread nor between the total number of threads in contact with bone.  相似文献   

3.
The purpose of this prospective study was to investigate the clinical outcome and marginal bone resorption of three different endosseous implants placed in the anterior mandibles of 15 elderly patients. Eleven women and 4 men (ranging from 65 to 80 years, mean 71 years) had three different endosseous implants placed in the anterior mandible; one titanium plasma-sprayed cylinder implant (4-mm diameter), one titanium cylinder implant with hydroxyapatite coating (4-mm diameter), and one standard threaded titanium implant (3.75-mm diameter). Three months later, at the second-stage surgical procedure, ball abutments were connected and an overdenture was placed. At 12, 24, and 36 months, marginal bone resorption and Periotest values were recorded. None of the implants was lost in this period. An analysis of variance with repeated measurement was performed annually to test the existence of significant differences between the implants. When differences appeared, paired t tests were used to identify which differences were significant. Bonferroni multipliers were used to adjust for multiple testing. When marginal bone resorption was concerned, threaded titanium and hydroxyapatite-coated implants had significantly better scores than titanium plasma-sprayed cylinder implants. Periotest values for hydroxyapatite-coated implants were significantly better than test values for the other implants after 2 years. After 3 years significance was obtained between hydroxyapatite and screw-shaped implants only (P < .05). It was concluded that titanium plasma-sprayed cylinder implants have a less favorable prognosis than the other implants used in this study.  相似文献   

4.
Limited bone height restricts the use of long dental implants, so short implants may be selected in these situations. Recent reports on clinical results with short implants have been negative, however, and have suggested that indications for the use of these implants are limited. To verify these findings, a multicenter study of short ITI implants was carried out. In a 6-year period 253 short implants with a length of 6 mm were placed into 126 patients, who were followed up from 1 to 7 years. Altogether 7 implants were removed; 6 of these were located in the maxilla and 1 in the mandible. The quality of survival was comparable with the clinical results of longer implants from the same implant system. Although the clinical results of these short implants were favorable, it is recommended that they be used in combination with longer implants, especially when used in the less dense bone that is often seen in the maxilla.  相似文献   

5.
PURPOSE: This article reviews the current knowledge about the influence of surgical factors on implant failure in routine cases and in those where implants have been used in conjunction with bone augmentation procedures. MATERIALS AND METHODS: Clinical reports published in major scientific journals served as the basis for this review. RESULTS: With few exceptions, most clinical reports were on screw-shaped titanium implants. High failure rates are associated with poor bone quality and the use of short implants in the athrophic maxilla, irradiation, and bone-grafting procedures of the athrophic maxilla. Evidence for high long-term failure rates of press-fit cylinders was found. Moreover, limited clinical experience, lack of preoperative antibiotics, and smoking may lead to higher failure rates. CONCLUSION: There is a need for further research to increase the success rates in the severely resorbed maxilla. Because of a lack of proper documentation with respect to the great majority of currently used oral implant designs, the influence of different factors and their long-term results remain unknown.  相似文献   

6.
Clinical evaluations of a new porous-surfaced implant concept (Endopore) in a large population of fully and partially edentulous patients are reported, and a technique of spreading buccal and lingual plates with osteotomes to place these implants in proximity to the sinus of the posterior maxilla is described. Three-dimensional, interconnecting pores on this implant's bone interface surface give a great surface area for bone engagement. When the maxilla is prepared by this spreading procedure, these implants can be successfully placed in areas having limited available bone. Our success rates are 97.0% for implants stabilizing a mandibular overdenture and 94.8% for implants placed in partially edentulous patients. Many times, sinus lift or other augmentation procedures can be avoided in the maxilla and mandible, allowing for less patient morbidity and for an implant reconstruction that is more affordable for the patient.  相似文献   

7.
RA Horowitz 《Canadian Metallurgical Quarterly》1997,18(5):441-7, 450-2; quiz 454
The placement of endosseous dental implants is often hampered by the loss of alveolar bone. In the posterior maxilla, the presence of the maxillary sinus and less-dense bone present additional obstacles to successful implant placement. Existing methods of subantral augmentation require extensive surgical manipulation, often including a second surgical site for harvesting autogenous bone. The development of surgical osteotomes has facilitated the placement of implants in areas of minimal alveolar bone height in the posterior maxilla. This article describes the osteotome technique for sinus augmentation at the time of implant placement and presents a short-term evaluation of 34 implants placed in 18 patients.  相似文献   

8.
The aim of present study was to correlate the changes in the peri-implant tissues occurring after functional loading of non-submerged titanium implants and assessed by radiographic, clinical and mobility measurements. 11 patients with distal extension situations received 18 implants of the ITI Dental Implant System. After a healing period of 3 months, the suprastructures were fabricated and seated 5 months post-surgically. For the assessment of peri-implant bone changes, standardized vertical bitewing radiographs with reproducible exposure geometry were evaluated using computer assisted densitometric image analyses (CADIA) and bone height measurements. Since the radiographic evaluations were performed at mesial and distal sites only, the clinical parameters from these implant aspects were included in the analysis. Clinical periodontal parameters modified for the use around implants were obtained, damping characteristics were expressed as Periotest readings and standardized radiographs were obtained at 1, 3, 6, 12 and 24 months after loading. In addition, radiographs were also taken at the start of functional loading. The data obtained from this small sample of implants demonstrated a wide range of different tissue alterations when using radiographic, clinical and mobility assessments. The parameters of probing attachment level (PAL) in combination with radiographic parameters obtained at 1, 3, and 6 months after loading were good predictors for the peri-implant tissue status at 2 years. This was shown by means of multiple stepwise regression analyses. Mobility measurements did not reveal valuable predictive information with the statistical models applied. Assessments of probing attachment levels using periodontal probes rendered information on peri-implant tissue alterations, which were closely correlated to the radiographically measurable peri-implant bone changes.  相似文献   

9.
The possibility of placing endosseous implants in the edentulous maxilla is frequently reduced by inadequate bone volume of the residual ridge. In totally edentulous maxillae with knife-edge conformation, insufficient thickness is frequently associated with insufficient height of the residual ridge in the posterior maxilla because of pneumatization of the maxillary sinuses. This surgical method combines grafting of the maxillary sinuses, onlay grafts on the buccal side of maxillary posterior segments, and sagittal osteotomy of the anterior maxilla with interpositional bone grafts. Five to six months after maxillary reconstruction, Br?nemark implants were placed and, after osseointegration occurred, implant-supported dental prostheses were fabricated. Three patients have been treated with this method and 22 implants have been placed. The mean follow-up after final prosthetic rehabilitation has been 16 months; survival rate has been 100%. Despite the small number of patients and the short follow-up, preliminary results have shown very promising results.  相似文献   

10.
STATEMENT OF PROBLEM: The surgical and restorative procedures at the posterior region of the maxilla and the mandible present a complex task in the treatment of partially edentulous patients. PURPOSE: The purpose of this study was to investigate the applicability of short hydroxylapatite-coated dental implants to the posterior mandible of partially edentulous patients. MATERIAL AND METHODS: Eight and 11 mm implants were evaluated as to their cumulative survival rate, clinical status (plaque index, gingival index, probing depth), and marginal bone loss over a 5-year period. RESULTS AND CONCLUSIONS: The verified overall cumulative survival rate was 94% for implants and 91% for prostheses. These results suggest predictable success for the application of short implants to the posterior mandible.  相似文献   

11.
DA Cottrell  LM Wolford 《Canadian Metallurgical Quarterly》1998,56(8):935-41; discussion 941-2
PURPOSE: This prospective study was designed to evaluate the long-term clinical and radiographic results of porous block hydroxyapatite (PBHA) used as a synthetic bone graft in orthognathic surgery and craniofacial augmentation. PATIENTS AND MATERIALS: A total of 245 consecutive patients were treated initially. Inclusion criteria for this study included a minimum clinical and radiographic follow-up of 5 years. In addition, all patients with known implant failures were included regardless of whether they met the study criteria. There were 111 patients that met the criteria for inclusion in this study. All patients had undergone orthognathic surgery with rigid fixation and had had inlay or onlay PBHA implants placed. Ninety-six percent of the implants were placed through an intraoral approach. Long-term postoperative radiographs were visually compared with immediate postoperative radiographs for implant position, stability, resorption, and other significant radiographic changes. The clinical examination evaluated for signs and symptoms of infection, wound dehiscence, implant exposure, implant displacement, changes in the overlying mucosa, and development of oronasal or oroantral fistulae. RESULTS: Four hundred seventy-one implants were placed: 403 in the maxilla, 44 in the mandible, and 24 in the periorbital region. There were 289 implants placed in direct communication with the maxillary sinus. The average follow-up time was 7.2 years (range, 5.0 to 10.3 years). Twenty-three implants (4.9%) were removed during the evaluation period. Lateral maxillary wall grafting had 95.7% success, with nine implants being lost in three patients. One chin implant was removed because of dissatisfaction with the aesthetics. Seven (14%) midpalatal implants used for maxillary expansion were lost, primarily because of exposure of the implant to the oral or nasal cavity at the time of surgery. When PBHA was used for alveolar cleft grafting, there was a 100% failure rate. CONCLUSION: The use of PBHA as a bone graft substitute in orthognathic surgery and for facial augmentation showed a high percentage of success and efficacy. However, adequate soft tissue coverage in the nasal floor and on the palate are paramount for success of midpalatal implants. PBHA should not be used for alveolar cleft grafting. Rigid fixation for inlay implants in the maxilla is important to provide stress shielding of the material and minimize micromovement during the initial healing phase.  相似文献   

12.
Early in the development of implant technology it became apparent that conventional dental imaging techniques were limited for evaluating patients for implant surgery. During the treatment planning phase, the recipient bed is routinely assessed by visual examination and palpation, as well as by periapical and panoramic radiology. These two imaging modalities provide a two-dimensional image of mesial-distal and occlusal-apical dimensions of the edentulous regions where implants might be placed. When adequate occlusal-apical bone height is available for endosteal implants, the buccal-lingual width and angulation of the available bone are the most important criteria for implant selection and success. However, neither buccal-lingual width nor angulation can be visualized on most traditional radiographs. Although clinical examination and traditional radiographs may be adequate for patients with wide residual ridges that exhibit sufficient bone crestal to the mandibular nerve and maxillary sinus, these methods do not allow for precise measurement of the buccolingual dimension of the bone or assessment of the location of unanticipated undercuts. For these concerns, it is necessary to view the recipient site in a plane perpendicular to a curved plane through the arch of the maxilla or mandible in the region of the proposed implants. Implant dentists soon recognized that, for optimum placement of implants, cross-sectional views of the maxilla and mandible were the ideal means of providing necessary pre-operative information. Today, the two most often employed and most applicable radiographic studies for implant treatment planning are the panoramic radiograph and tomography. Although distortion can be a major problem with panoramic radiographs, when performed properly they can provide valuable information, and are both readily accessible and cost efficient. To help localize potential implant sites and assist in obtaining accurate measurements, it is recommended that surgical stents be used with panoramic radiographs. In simple cases, where a limited number of implants are to be placed, panoramic radiography and/or tomography may be used to obtain a view of the arch of the jaw in the area of interest. For complex, cases, where multiple implants are required, the CT scan imaging procedure is recommended. Because of its ability to reconstruct a fully three dimensional model of the maxilla and mandible, CT provides a highly sophisticated format for precisely defining the jaw structure and locating critical anatomic structures. The use of CT scans in conjunction with software that renders immediate "treatment plans" using the most real and accurate information provides the most effective radiographic modality currently available for the evaluation of patients for oral implants. To follow patients after implant surgery, DSR can be helpful by addressing the limitations of other radiographic modalities in detecting postoperative changes. By eliminating unchanged information, DSR allows the clinician's eye to focus on actual changes that have occurred between the recordings of two images.  相似文献   

13.
The aim of this study was to evaluate the clinical function and long-term prognosis of overdentures retained by a small number of implants in the maxilla and mandible using one of two different attachment systems. Included in the study were all patients referred to specialty clinics in J?nk?ping and Link?ping, Sweden, during the treatment period who needed an overdenture and could be provided with a minimum number of two bilaterally-placed implants. Excluded were patients with bone-grafted jaws, irradiated cancer patients, heavy bruxers, and patients who had lost a fixed prosthesis because of implant losses. The patients were randomly assigned to receive one retentive system, either a round 2-mm-diameter bar with clips or ball attachments (Nobel Biocare). Eighteen overdentures were placed in maxillae and 32 in mandibles, supported by a total of 115 Br?nemark implants. Of the implants placed, 86.1% were continuously osseointegrated. The cumulative implant survival rates after 7 years of loading were 75.4% in the maxillae and 100% in the mandibles. There was no difference in implant survival rate between the attachment systems. Patients with implant losses were characterized by severely resorbed maxillary ridges and inferior bone quality, together with unfavorable loading circumstances such as short implants combined with long leverages. Complications and prosthetic adjustments were mostly resolved early and easily.  相似文献   

14.
The term "peri-implantitis" is used to describe the formation of deep mucosal pockets around dental implants, inflammation of the peri-implant mucosa, and increased resorption of peri-implant bone. It has been speculated that when left untreated, peri-implantitis can result in implant failure. This retrospective study examines a possible correlation between smoking and the appearance of peri-implantitis. The clinical and radiographic observations of 366 implants in 107 patients who smoke were compared with those of a group of 1000 implants in 314 nonsmoking patients. Despite the retrospective nature of this study, a comparison between the two groups was possible. The mean follow-up period, mean patient age, implant locations, and percentages of fixed partial dentures and overdentures were consistent in both groups. There was no significant difference in the mean maxillary and mandibular hygienic indices between the group of smokers and that of nonsmokers. However, the group of smokers showed a higher score in the bleeding index, the mean peri-implant pocket depth, the degree of peri-implant mucosal inflammation, and radiographically discernible bone resorption mesial and distal to the implant. In the maxilla of the smoking group, these observations were significantly higher than both the mandibular observations for smokers and the maxillary observations of the group of nonsmokers (p < 0.01). No differences between the two groups were observed in the mandible. Aside from the systemic effects of tobacco smoking on the human organism, local cofactors seem to be responsible for the higher incidence of peri-implantitis in smokers and have a particularly negative effect on the maxilla. These findings confirm that smokers treated with dental implants have a greater risk of development of peri-implantitis.  相似文献   

15.
Because of the frequent lack of bone in the posterior maxilla, sinus augmentation has become a commonly practiced treatment modality. Many different materials have been used for augmenting the sinus, and the ideal graft is yet to be found. The present article reports the results of sinuses grafted with calcium sulfate in 2 patients. Bone biopsies were harvested 9 months after the augmentation procedure. In the first patient, 3 titanium threaded-cylinder implants were placed in the grafted area after 9 months, while in the second, 1 acid-etched, screw-shaped titanium implant was placed simultaneously with the graft. Light microscopic evaluation revealed new bone formation with ongoing remodeling and progressive lamellar maturation in the specimens. No remnants of the alloplastic material were detectable in any section, either within the bone or in the medullary tissue. When reevaluated at the uncovering procedure, the implants were radiographically and clinically judged to be osseointegrated. These observations suggest that, when used in the appropriate form and with the proper technique, calcium sulfate is a promising graft material for sinus augmentation, producing adequate quantity and quality of new bone for implant placement.  相似文献   

16.
The aim of the present study was to evaluate the capability of the Periotest device in detecting and monitoring functional changes in the periodontal as well as in the pari-implant damping characteristics. In the first part of this study, 107 teeth were splinted by means of 40 full acrylic fixed prostheses (AFP) and another 37 teeth were splinted by means of 14 ceramometallic fixed prostheses (C-MFP). The Periotest measurements of individual teeth were done the day the fixed prostheses were cemented temporary (PTV 1), and again after a mean observation period of 27.4 days (PTV 2). In the 2nd part, 78 osseointegrated two-stage implants were splinted by means of 23 full acrylic fixed prosthesis (AFP) and other 18 implants were left without it. Using the same abutment length, Periotest measurements were performed, at abutment connections and before installation of the final prosthesis. In a 3rd part, using both implants and teeth as abutments, 29 osseointegrated implants were connected with 25 abutment teeth by means of 7 AFP. The measurements were performed at the beginning of the prosthetic treatment and 2, 4 and 6 weeks later. After splinting teeth by means of AFP for the observation period, no statistically significant reduction in PTVs was found. When on the other hand, a C-MFP was used, PTV 2 showed a significant reduction. The PTVs at abutment connection went down after a period of time, during which some implants were interconnected by means of an AFP and others were not.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
The posterior maxilla has traditionally been one of the most difficult areas to successfully place dental implants due to poor bone quality and close approximation to the maxillary sinus. Sinus augmentation procedures have become a viable means of assuring adequate bone for the placement of dental implants in this area. However, with the techniques currently employed, a considerable variation in the quality of bone attained with the sinus augmentation procedure exists. The purpose of this in vivo study was to evaluate the healing response and bone formation stimulated by 3 doses of recombinant human osteogenic protein-1 (rhOP-1), 0.25, 0.6, and 2.5 mg OP-1 per gram of collagen matrix; natural bone mineral; or collagen matrix alone (control) placed in the maxillary sinus of adult chimpanzees. Results were assessed using clinical, histologic, and radiographic techniques. Radiographic analysis of the computed tomography scans taken at 1 week, and 2.5, 4.5, and 6.5 months revealed a more rapid mineralization with the 2.5 mg OP-1/g collagen matrix and natural bone mineral treatment groups. The incremental bone mineral density (BMD) increase for these 2 treatments from 1 week to 2.5 months was over 2.5 times the increase found with the collagen matrix alone; these 2 treatments also had a higher BMD at the most superior slices evaluated when compared to the other 3 groups. Biopsy specimens were taken at 3.5, 5.5, and 7.5 months and for all 5 treatment groups bone formation was observed at all time points in the majority of the specimens. At 7.5 months the 2.5 and 0.6 mg OP-1/g collagen matrix treatment groups had an increase in the percent bone area when compared to the matrix alone control. In conclusion, these results demonstrate that sinus augmentation with natural bone mineral or 2.5 mg OP-1/g collagen matrix induce comparable radiographic and histologic evidence of bone formation and that both of these treatments performed superior to the control group of collagen matrix alone based upon all methods of evaluation.  相似文献   

18.
This pilot study analyzed the bone reactions to early loaded titanium plasma-sprayed implants. A total of 24 titanium plasma-sprayed implants (12 in the maxilla and 12 in the mandible) (Primary Healing Implant, Legnano) were inserted into four Macaca fascicularis monkeys with instruments specially designed to obtain a precise fit of the implant in the bone socket. A metal superstructure was cemented into 10 mandibular and 10 maxillary implants 15 days after implant insertion. The four remaining implants were used as controls. Eight months after implant placement, a block section was carried out, the defect was filled with nonresorbable hydroxyapatite, and all 24 implants were retrieved. The implants were treated to obtain thin ground sections that were examined under normal and polarized light. Histologic analysis showed that bone was observed around the implant surface in all implants. Morphometric analysis demonstrated that bone lined 67.2% (SD = 3.1%) of the maxillary implant surface, and 80.71% (SD = 4.6%) of the mandibular implant surface. No differences were found in the percentage of bone-implant contact in the control implants. In the loaded implants, however, the bone around the implants had a more compact appearance. The study demonstrated that it is possible to obtain a high percentage of bone-implant contact in early loaded titanium plasma-sprayed implants.  相似文献   

19.
Osseointegrated implants can be used to facilitate retention stability and support for facial and intraoral prostheses used to restore head and neck defects. Preliminary studies indicate that in nonirradiated maxillectomy patients the success rates are about 75%. In the reconstructed mandible the results appear to be more favorable--over 90% for implants placed in free nonvascularized bone grafts and over 90% for free revascularized bone grafts. Similar high success rates have been observed for most sites used to support facial prostheses. Success rates for auricular sites exceed 95% and for floor of nose sites success rates exceed 90%. Success rates have been lower (77%) for implants placed in the frontal bone for retention of orbital prostheses. Success rates for irradiated bone sites have been lower and range from 60.4% in the maxilla to 68.6% in facial bone sites. Of greater concern is that most implants placed in irradiated sites are beginning to show signs of impending failure.  相似文献   

20.
The efficacy of a bone-graft substitute (bovine-derived bone protein in a carrier of natural coral) in the healing of a segmental defect of a weight-bearing long bone was evaluated. Twenty dogs, divided into two groups, underwent bilateral radial osteotomies with creation of a 2.5 cm defect. On one side of each dog, the defect was filled with autogenous cancellous bone graft. Contralateral defects received, in a blinded randomized fashion, cylindrical implants consisting of natural coral (calcium carbonate) or calcium carbonate enhanced with a standard dose of bovine-derived bone protein (3.0 mg/implant; 0.68 mg bone protein/cm3). The limbs were stabilized with external fixators, and all animals underwent monthly radiographs. They were killed at 12 (group 1) or 24 (group 2) weeks, and regenerated bone was studied by biomechanical testing and histology. Radiographic union developed in all 20 radii with autogenous cancellous bone grafts and in all 10 of the radii with the composite implants. None of the radii with implants of calcium carbonate alone showed radiographic evidence of union. This represented a statistically significant difference between implant types. In addition, calcium carbonate implants both with and without bone protein demonstrated radiographic evidence of near total resorption of the radiodense carrier by 12 weeks. This resorption facilitated radiographic evaluation of healing. Mean values for biomechanical parameters of radii with the composite implants exceeded those for the contralateral controls at 12 and 24 weeks; the difference was statistically significant at 12 weeks. Histology revealed scant residual calcium carbonate carrier at either time in the defects with calcium carbonate implants; however, a moderate amount was present in defects with the composite implants. In these specimens, the residual carrier was completely surrounded by newly formed bone that may have insulated the calcium carbonate from further degradation. The present study used a carrier of granular calcium carbonate reconstituted with bovine type-I collagen to deliver an osteoinductive protein to the defect site. This carrier is of nonhuman origin (eliminating the risk of disease transmission or antigenicity) and resorbs rapidly. In this model, bovine-derived bone protein in a natural coral carrier performed consistently better than the gold standard autogenous cancellous bone graft in terms of the amount of bone formation and strength of the healed defect. This may have implications for removal of hardware or resumption of weight-bearing in certain clinical situations. These data also indicate that coralline calcium carbonate alone represents a poor option as a bone-graft substitute in this critical-sized segmental defect model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号