首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from an industrial park operated as Taiwan's center of metallurgical industries were investigated. The characteristics of mean PCDD/F I-TEQ concentrations, congener profiles and emission factors of each source were studied over samples of stack flue gases of individual sources. Different characteristics of congener profiles and large variations of emission factors of secondary aluminum smelters (ALSs) were observed. The mean emission factors of electric arc furnaces were comparable to those for ALSs and much greater than those of municipal solid waste incinerators and sinter plants, but still less than that of clinical waste incinerators. Annual PCDD/F emission contribution of each source was estimated, raising critical concerns over the overall PCDD/F emissions from metallurgical processes. The metallurgical industries altogether contributed approximately 98.1% of the total annual emissions, while waste incinerators only 1.9%. The contributions by sinter plants and metallurgical industries to the total annual emissions of the Park were much higher than the corresponding national averages of Taiwan. The combined dioxin emissions from the entire metallurgical processes and their controls should be seriously envisaged by industrial parks devoted to metal productions.  相似文献   

2.
While the sources of releasing dioxins have received much attention, the health risks of incinerators are studied considerably more than those of other sources, such as metallurgical industry. Furthermore, risk assessments focus primarily on the effects of single sources; few have addressed the aggregate risks from multiple sources in a region. When many sources of dioxins exist in an area, such as the Industrial Park located in the densely populated district—Siaogang District in southern Taiwan where 17 primary known PCDD/F stationary emission sources are clustered, is the aggregate exposure to these sources imposing high risks even though individual sources comply with emission standards? The study combined the multimedia and multiple pathway exposure modeling and site-specific exposure scenario to assess dioxin risks contributed by the 17 emission sources in the District, including municipal waste incinerators, medical waste incinerators, sinter plants, electric arc furnace, secondary aluminum smelters, cement kilns, etc. The average cancer risk of a resident living in the District was found to be 3.43E−04 under the site-specific exposure scenario. The top emission source is the sinter plant, followed by the electric arc furnace. The information has driven the local government to conduct more complete assessment and at the same time to consider enforcing a stricter local standard of dioxin emissions in the Siaogang District.  相似文献   

3.
In southern Taiwan, two areas (L- and Y-) with/without biomass open burning were selected to compare the PCDD/F concentrations and their congener profiles in the ambient air. The results of this study indicate that biomass (rice straw) open burning exhibited a significant impact on the PCDD/F concentration level in the ambient air. During the biomass burning season, the total PCDD/F I-TEQ concentrations in the ambient air of L- and Y-areas were approximately 4 and 17 times higher than those without biomass open burning, respectively. When 10% mass fraction of rice straw was burned, the contribution fraction of biomass burning on annual total PCDD/F I-TEQ emission was 3.28 and 8.11% for KC County and for Taiwan, respectively; however, when the calculation was on a weekly basis, the contribution fraction of biomass burning on weekly total PCDD/F I-TEQ emission was 30.6 and 53.4% for KC County and for Taiwan, respectively. The results of this study imply that during the week of biomass burning, it appears to be the most significant source of total I-TEQ PCDD emission. The results of this research can be applied to the study of other agricultural areas.  相似文献   

4.
To our best knowledge, this study is the first research which investigates whether the PCDD/F memory effect could also be caused by bag filters. In this study, the PCDD/F characteristics of the flue gases in front of and behind the bag filters of one municipal solid waste incinerator (MSWI) and two electric arc furnaces (EAFs) were investigated to clarify the memory effect of PCDD/Fs and their influence on emissions. After the bag filters were operated for over four years, the PCDD/F concentrations in the stack flue gases were all higher than those prior to the aged bag filter, rendering a negative PCDD/F removal. This memory effect is because gaseous phase PCDD/Fs are released from the contaminated filters of the aged bag filters. The release of 2,3,7,8-TeCDF, 1,2,3,7,8-PeCDF and 2,3,4,7,8-PeCDF from the contaminated filters of the EAFs increased the PCDD/F concentration and their fractions in the stack flue gases. In contrast, the MSWI exhibited increasing fractions of 1,2,3,4,6,7,8-HpCDD, OCDD after flue gases passed through its aged bag filter. The activated carbon of the MSWI adsorbed more lower chlorinated-substituted PCDD/Fs in the raw flue gases, and the remaining higher chlorinated congeners gradually accumulated on the aged filters, and were released in lower PCDD/F concentration conditions.  相似文献   

5.
Different approaches were carried out in this work to assess environmental impacts of a municipal solid waste incinerator. A total of seven sites in the vicinity of the facility were chosen to collect air, banyan leaf and soil samples for analyses of PCDD/Fs by high-resolution gas chromatography/high-resolution mass spectrometry. Based on the PCDD/F concentrations of the three matrices determined at sites upwind, downwind and area of maximum ground concentration, it was found that the environmental impact of the MSWI was not obvious. PCDD/F concentration isopleths of the three environmental compartments coupled with wind rose of the region proved that the influence of the MSWI on the environment was also rather limited. It clarified emission sources by confirming that the PCDD/F concentrations originated mostly from the existing stationary emission sources in the vicinity. Through principal component and cluster analyses on congener profiles, the influence of metallurgical facilities and medical waste incinerators on the ambient air was assessed. Moreover, the modeling of ISCST3 demonstrated also that the contribution of the MSWI to ambient atmospheric PCDD/Fs was minimal. The approaches studied have led to identical conclusions, and thus are useful to cross-evaluate the environmental impact of an MSWI.  相似文献   

6.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the surrounding environment (outdoor) and workplace air of two municipal solid waste incinerators (MSWIs, T and M) were characterized and compared. T and M represented two typical municipal solid waste incinerators in the north of Taiwan, which have different processes for controlling the PCDD/F emissions. The results of this study are summarized as follows. (1) The total PCDD/F and the total PCDD/F WHO-TEQ concentrations in the workplace air were 5-13 and 5-15 times higher than those in the outdoor air, respectively. Obviously, it is worthwhile to explore more on health risk assessment for exposure of PCDD/Fs emitted from MSWIs, particularly in the workplace air. (2) Mean total PCDD/F I-TEQ concentrations in the outdoor air ranged between 0.0216 and 0.155 pg I-TEQ/Nm(3) and averaged 0.0783 pg I-TEQ/Nm(3) (0.0828 pg WHO-TEQ/Nm(3)) during two seasons for two MSWIs, which were 6.5-fold higher than that of a remote site (0.0119 pg I-TEQ/Nm(3) or 0.0132 pg WHO-TEQ/Nm(3)) in Taiwan. However, the above outdoor air concentration levels in the MSWIs were still much lower than the air quality limitation of PCDD/Fs (0.6 pg I-TEQ/Nm(3)) in Japan []. (3) PCDFs were the primary toxicity distributors for PCDD/Fs in the outdoor air, since the ratios of PCDDs/PCDFs (I-TEQ) at all sampling sites ranged from 0.180 to 0.492 and were less than unity. (4) The OCDD, OCDF, 1,2,3,4,6,7,8-HpCDD and 1,2,3,4,6,7,8-HpCDF were the four dominant species in both workplace and outdoor air near MSWIs. (5) By spraying water on and wetting both the fly and bottom ashes, the mean total PCDD/F I-TEQ concentration in the workplace air was reduced 86.9% in the T MSWI. The above results indicate an appropriate improving action did inhibit the fugitive emission of PCDD/Fs and reduce the health risk of workers during work handling ashes in MSWIs.  相似文献   

7.
The concentrations of 17PCDD/F congeners as well as tetra- to octa-homologues were determined in 33 soil samples collected within a radius of 7 km from a municipal solid waste (MSW) incineration plant that is equipped with three fluidized bed incinerators (FBIs) of co-firing MSW with coal in Hangzhou, China. The total PCDD/F concentrations ranged from 0.39 to 5.04 pg I-TEQ g(-1) (54-285 pg g(-1)), with an average and a median value of 1.22 and 0.84 pg I-TEQ g(-1) (105 and 86 pg g(-1)), respectively. A systematic decrease of PCDD/F levels was observed with the increasing distances and with the decreasing downwind frequencies from the plant. The comparisons of homologue and congener patterns and multivariate analysis of soil and flue gas samples strongly indicated that most of the soil samples were influenced by the FBIs. Apart from the incineration plant, historical PCDD/F emissions of hazardous waste incinerator (HWI) and motor vehicles as well as the application of 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP) seemed to play an important role in soil samples adjacent to these potential sources.  相似文献   

8.
Different from most previous studies with quantity-limited data, this paper presents PCDD/F content characterization in the fly ash discharged from sixteen large-scale commercial MSWIs. From the results with over hundreds of data using periodically sampling and analysis, it was found that the PCDD/F contents in the fly ash were from 9.07 to 46.68 ng/g, d.w., and if based on international toxicity equivalent quantity, they were from 0.78 to 2.86 ng I-TEQ/g, d.w. The higher chlorinated PCDDs likely dominated more than lower chlorinated PCDDs, but this tendency was not for PCDFs. The OCDD had the highest contribution to the total PCDD/F content, but if based on I-TEQ content, 2,3,4,7,8-PeCDF is the PCDD/F congener with the highest toxicity contribution. Moreover, the PCDD/F characteristic index (DCI) is suggested using the representative congener content of 2,3,4,7,8-PeCDF to characterize the fly ash. The DCI is 0.875 ± 7.6% for the fly ash discharged from the MSWI with the APCD assembly of SD, AC and BF. The findings obtained in this work provide overview information on the PCDD/F content characterization in fly ash. They will provide PCDD/F fingerprint information to distinguish from other PCDD/F sources, like steel refinery industry, hazardous waste incinerators, or cement kilns, and thus be applied to fly ash management in the environment.  相似文献   

9.
Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in water and suspended particulate matter (SPM) collected from the Xijiang River, China, were measured by the quarter from September 2005 to June 2006. Total PCDD/F concentration ranged from 2.659 to 4.596pg/L for water and from 562.4 to 3259.5pg/g for SPM. Concentrations were high in summer and low in winter. I-TEQ values in water and SPM were low, ranging from 0.012 to 0.075pg/L, with a mean value of 0.039pg/L. Calculated annual loadings of total PCDD/Fs and I-TEQ were 8.55kg and 0.026kg, respectively. Composition and homologue distribution of PCDD/Fs were varied because of large seasonal differences in discharge from the Xijiang River into the South China Sea. Comparison of the PCDD/Fs homologue and congener profiles of atmospheric deposition, soil, and water revealed that soil was the dominant source of PCDD/Fs in the Xijiang River. Industrial effluents were also possible sources of PCDD/Fs. A good correlation between logK(oc) and logK(ow) was observed for 2,3,7,8-substituted PCDDs and PCDFs and correlation coefficients were 0.71 and 0.84, indicating organic matter in SPM played a dominant role in PCDD/Fs partition between SPM and water.  相似文献   

10.
We measured the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from the flue gas and the ambient atmosphere of a power plant fueled by heavy oil in northern Taiwan. The mean emission concentration and I-TEQ concentration of total PCDD/Fs were 0.292 ng/Nm(3) and 0.016 ng I-TEQ/Nm(3), respectively. All PCDD/F emission concentrations in the flue gas were supposed to meet the Environmental Protection Administration Executive Yuan, R.O.C. standard (1.0 ng I-TEQ/Nm(3) from 2008). Furthermore, the mean I-TEQ concentration in the ambient atmosphere was 0.011 pg I-TEQ/Nm(3), which was much lower than the environmental quality standards for dioxins in Japan (0.6 pg TEQ/Nm(3)). Also, the PCDD/F emission factor was 0.188 ng I-TEQ/L fuel, which was comparable to the data issued in US EPA [EPA, Locating and estimating air emissions from sources of dioxins and furans, Office of Air Quality Planning and Standards, Research Triangle Park, NC, DCN No. 95-298130-54-01, 1997] (0.2 ng I-TEQ/L of fuel). Also, the result of the correlations of PCDD/Fs and operational parameters illustrated that the positively significant correlation (r=0.502, p=0.048) was found only between PCDD/Fs (I-TEQ) and the flue gas emission temperature (125-157 degrees C). However, PCDD-TEQ/PCDF-TEQ ratios were statistically significantly associated with the decreased flue gas flow (r=-0.659, p=0.006), moisture (r=-0.612, p=0.012) and flue gas temperature (r=-0.503, p=0.047). For proper environmental management of dioxins, it is necessary to establish a complete emission inventory of PCDD/Fs, and, in particular, the government should pay more attention to power plants to address the information shortage.  相似文献   

11.
Hair samples collected from e-waste recycling workers (n=23 males, n=4 females) were analyzed to assess occupational exposures to polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) at a large e-waste recycling facility in Taizhou, eastern China. Hair samples from a reference population composed of residents of Shanghai (n=11) were analyzed for comparison. The mean concentration of ∑PBDEs (range, 22.8-1020 ng/g dw; mean, 157 ng/g dw) found in hair samples from e-waste recycling workers was approximately 3 times higher than the mean determined for the reference samples. The congener profiles of PBDEs in hair from e-waste recycling workers were dominated by BDE 209, whereas the profiles in the reference-population samples showed comparable levels of BDE 47 and BDE 209. Total PCDD/F concentrations in hair from e-waste workers (range, 126-5820 pg/g dw; mean, 1670 pg/g dw) were approximately 18-fold greater than the concentrations measured in hair from the reference population. Concentrations of PCDFs were greater than concentrations of PCDDs, in all of the hair samples analyzed (samples from e-waste and non-e-waste sites). Tetrachlorodibenzofurans (TCDFs) were the major homologues in hair samples. Overall, e-waste recycling workers had elevated concentrations of both PBDEs and PCDD/Fs, indicating that they are exposed to high levels of multiple persistent organic pollutants.  相似文献   

12.
The PCDD/DFs and coplanar PCBs (co-PCBs) in sediment samples from Gwangyang Bay in South Korea was investigated. The total concentration of dioxins and their toxic equivalent quantity (TEQ; calculated with the WHO 2005 Toxic Equivalency Factors) value in the surface sediment of the outer site (261 pg g(-1) TOC, 4.4 pg-TEQ g(-1)) were 3-fold higher than the inner site (90 pg g(-1) TOC, 1.1 pg-TEQ g(-1)) in the Bay. The dioxin in the sediment samples was found to come from a mixture of the impurities of pentachlorophenol (PCP), chloronitrofen (CNP) and combustion based on the result of hierarchical cluster analysis (HCA). These dioxin sources have been influenced by the characterization associated with this region which was both an agricultural-centered and industrial-centered area. According to principal component analysis (PCA) related to the Kow values for the congener-specific composition of co-PCBs in the sediment core, the Kanechlor (KC)-500 and the atmospheric deposition were identified as the possible sources. The maximum burden in the sediment core was 1.3 kg for 1967-1974 and the total burdens of PCDD/DFs and co-PCBs in the sediment core were estimated to be 6.6 kg during the past 50 years. The cumulative burdens of dioxin are still increasing in Gwangyang Bay.  相似文献   

13.
This study focuses on the atmospheric dry deposition flux of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the vicinity of the two municipal solid waste incinerators (MSWIs) located in southern Taiwan. PCDD/Fs in ambient air were taken and analyzed for seventeen 2,3,7,8-substituted PCDD/Fs during November 2004 and July 2005. Results show that the mean concentrations of PCDD/Fs in the ambient air near MSWI-GS and MSWI-RW were 0.090 and 0.097pg I-TEQ/Nm(3), respectively. Dry deposition fluxes of total PCDD/Fs were 18.0 and 23.5pg I-TEQ/(m(2)d) in the ambient air near MSWI-GS and MSWI-RW, respectively, which were considerably higher than that measured in Guangzhou, China. Annual dry deposition fluxes of total PCDD/Fs in the ambient air near MSWI-GS and MSWI-RW were 189 and 217ng/(m(2)year), respectively, which were also much higher than dry deposition of total PCDD/Fs to the Atlantic Ocean. The results of the present study strongly suggest that exposure to PCDD/Fs in this area should be reduced. In addition, parametric sensitivity shows that dry deposition flux of PCDD/Fs is most sensitive to dry deposition velocity of the particle-phase, followed by air temperature and concentration of total suspended particulate but least sensitive to dry deposition velocity of the gas-phase.  相似文献   

14.
Since the "Toxic Egg Event" broke out in central Taiwan, the possible sources of the high content of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in eggs have been a serious concern. In this study, the PCDD/F contents in different media (feed, soil and ambient air) were measured. Evaluation of the impact from electric arc furnace dust treatment plant (abbreviated as EAFDT plant), which is site-specific to the "Toxic Egg Event", on the duck total-PCDD/F daily intake was conducted by both Industrial Source Complex Short Term model (ISCST) and dry and wet deposition models. After different scenario simulations, the worst case was at farm A and at 200 g feed and 5 g soil for duck intake, and the highest PCDD/F contributions from the feed, original soil and stack flue gas were 44.92, 47.81, and 6.58%, respectively. Considering different uncertainty factors, such as the flow rate variation of stack flue gas and errors from modelling and measurement, the PCDD/F contribution fraction from the stack flue gas of EAFDT plant may increase up to twice as that for the worst case (6.58%) and become 13.2%, which was still much lower than that from the total contribution fraction (86.8%) of both feed and original soil. Fly ashes contained purposely in duck feed by the farmers was a potential major source for the duck daily intake. While the impact from EAFDT plant has been proven very minor, the PCDD/F content in the feed and soil, which was contaminated by illegal fly ash landfills, requires more attention.  相似文献   

15.
为治理城市的燃煤污染和降低二氧化碳的排放量,我国需要开发大型清洁能源。核能是可供选择的清洁能源之一,核能不仅可以用于发电,而且可以替代燃煤为城市供热。在我国现在池式研究堆技术的基础上,设计出的常压供热反应堆,可以满足城市供热的需要,具有高度的安全性和可靠性,是一种技术现实和经济可行的解决方案。在我国发展城市集中供热的条件下,采用这种大型热源,将会以较大的规模来改善大气环境和降低温室气体的排放。  相似文献   

16.
In a long-term program polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) as well as dioxin-like polychlorinated biphenyls (DL-PCBs) were analyzed in the muscle tissue of eels (Anguilla anguilla), bream (Abramis brama), European chub (Leuciscus cephalus) and ide (Leuciscus idus) from the river Elbe and its tributaries Mulde and Saale. The variation of the PCDD/F and DL-PCB concentrations in all fish samples is very large, whereby the DL-PCBs predominate in comparison to the PCDD/Fs. In the eels, the concentrations (pg WHO-TEQ/g ww) for the PCDD/Fs lie in the range of 0.48-22 and for the DL-PCBs between 8.5 and 59. In the whitefish, the concentration range is 0.48-12 for the PCDD/Fs and 1.2-14 for the DL-PCBs. Statistical analysis using relative congener patterns for PCDD/Fs allow spatial correlations to be examined for sub-populations of eels and whitefish. The results are compared to the maximum levels laid down in the European Commission Regulation (EC) No. 466/2001 and the action levels of the European Commission Recommendation 2006/88/EC. Eels caught directly after the major flood in August 2002 as well as eels near Hamburg (years 1996 and 1998) show high concentration peaks. Compared to the eels whitefish is less contaminated with PCDD/Fs and DL-PCBs.  相似文献   

17.
Polybrominated diphenyl ether (PBDE) concentrations of outdoor and indoor organic films on window glasses were measured at different locations (offices, laboratories, and homes in urban, suburban, rural, and industrial sites) in Izmir, Turkey. ∑(7)PBDE concentrations were dominated by technical penta and deca-BDE mixture components. Average total outdoor PBDE (∑(7)PBDE) concentrations for suburban, urban, and industrial sites were 43.5, 45.5, and 206 ng m(-2), respectively. This spatial gradient (industrial>urban>suburban concentrations) was similar to one observed for ambient air concentrations recently in Izmir, Turkey. The highest concentrations measured in the industrial area were attributed to the significant PBDE emissions from several steel plants located in the area. Air-organic film partitioning modeling results have suggested that organic films can be used in conjunction with the dynamic uptake model to approximate the gas-phase ambient air concentrations. Modeling results have also indicated that congeners in the gas-phase with very large octanol-air partition coefficients (i.e., BDE-154, -153, and -209) will require several months to approach equilibrium with the surface films. This finding may have important implications for gas-particle and gas-film partitioning, transport, and photolytic degradation of atmospheric PBDEs.  相似文献   

18.
The distribution and concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs, also called co-PCBs) in a typical area of eastern China were evaluated by analysis of 21 soil and 6 sediment samples. The range of WHO-TEQ values for the PCDD/Fs and dioxin-like PCBs in 17 soil samples representing the background investigation in the study area was 0.017-5.04 pg g(-1) (dry weight, dw), with a mean value 0.967(+/-1.361)pg g(-1) and medium value 0.348 pg g(-1), which indicates that the levels of PCDD/Fs and dioxin-like PCBs over the major part of this district were low. However, the WHO-TEQ values (6.52-16.7 pg g(-1) dw) for PCDD/Fs and dioxin-like PCBs in soil samples to the leeward of a known contaminated disassembly industrial park were much higher than that of the background investigation, and the levels of sediment samples downstream of this area were in the range 2.25-34.6 pg g(-1) (dw). The levels of WHO-TEQ in soil and sediment samples decreased with an increase in distance from the researched pollution source. The principal component analysis demonstrated that the PCDD/Fs and dioxin-like PCBs in major part of contaminated sediment and soil samples derived from the correlative matrix. Yet the different distribution patterns of them in part of sediment samples strongly indicate that other potential sources may be exist, further researches should be done to get more information about the sources and the distributions of the PCDD/Fs and PCBs.  相似文献   

19.
Postnatal exposure to dioxins in breastfed infants occurs mainly during breast-feeding. The exposure to a substantial amount of endocrine disruptors in the early days of life may cause long-term health effects. Test subjects were healthy and primiparous mothers with a mean age of 28 (S.D. = 3.8) in 2001. The PCDD/F congeners were analyzed in the breast milk using gas chromatograph/high resolution mass spectrometry. The mean level of PCDD/Fs was 7.4 pg-WHO-TEQ/g lipid, which is significantly lower than the level found in individuals from other countries. The total PCDD WHO-TEQ levels in breast milk had a significant positive association with maternal age and a slightly negative association with perinatal BMI (body mass index of the period before and after the delivery). The estimated daily intake of 10.5 pg-WHO-TEQ/kg/day from individual breast milk was predicted for a breastfed infant at 6 months of age with proper assumption of 8 kg body weight, 854 milk per day of consumption, 95% of dioxin absorption rate, and linear decline of dioxin during lactation. Based on the lower WHO-TEQ levels in the breast milk, breast-feeding should still be encouraged and continued in Taiwan.  相似文献   

20.
Fly ash from municipal solid waste (MSW), medical waste (MW) and electrical power plant (EPP) incinerators were analyzed for polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The study showed that the PCDD/F levels in fly ash were EPP < MSW < MW. The homologue profiles of PCDD/Fs in fly ash produced from waste incinerators were similar. However, the homologue profiles of PCDD/Fs in fly ash from electrostatic precipitator (ESP) of electrical power plant were different from that from waste incinerator. The strong correlation was found between the concentration of 2,3,4,7,8-PeCDF and the I-TEQ value of fly ash regardless of the different fly ashes sources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号