1.
This paper presents a new current copier which uses a differential‐pair as its storage cell. The differential‐pair storage unit (DPSU) significantly reduces clock‐feedthrough errors and achieves high linearity, large dynamic range, and less cross‐talk noise. Therefore, the proposed high‐performance DPSU can be used to improve the speed performance of analog‐to‐digital converters which implement the proposed fully differential switched‐current technique. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

2.
采用零器技术提出了两种基于电流传输器的理想接地电感实现电路。该电路结构简单,只用两块CCⅡ及3个接地无源元件,模拟电感受CC器件的非理想因素影响小且可由3个接地无源元件独立调节。研究表明,该电路中等效电感的无源灵敏度低、对有源参数变化不敏感。将该电路应用于二阶高通滤波电路中,并进行了计算机仿真和硬件实验研究,结果证实了本文提出的理想接地电感实现方案的正确性。  相似文献   

3.
A novel fully differential digitally programmable current conveyor (DPCCII) is presented in this paper. The programmability of the proposed DPCCII is achieved using three‐bit MOS R‐2R ladder current division network. The DPCCII is used to realize a field programmable analog array (FPAA). The FPAA consists of seven configurable analog blocks arranged in a hexagonal form. The FPAA power consumption is 72.3 mW from 1 V voltage supply. A second‐order programmable universal filter is realized using the proposed FPAA as an application. All the circuits are realized and simulated using 90 nm IBM CMOS technology model under balanced supply voltage of ±0.5 V. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
研究了一种常用的恒流源电路的输出动态特性。研究发现:在负载及输出电流值不变的情况下,影响恒流源动态性能的主要因素是误差放大器积分电容的容值、反馈放大器的放大倍数等;在电路参数固定的情况下,在一定的输出电流范围内,影响系统动态性能的主要因素是负载阻值,而电流值影响很小。最后,根据实际电路设计指标,提出了改善系统动态性能的解决方案,仿真及实际电路测试证明了结论的正确性。  相似文献   

5.
用电磁暂态仿真软件PSCAD(Power Systems Computer Aided Design)进行仿真,在界面上可设置系统参数、故障距离、故障类型等相关参数,启动一次仿真计算;然后利用MATLAB(Matrix Laboratory矩阵实验室)程序读取仿真得到的数据进行判据的计算,画出差流和制动电流的波形。分析了不同运行条件下保护判据的灵敏度、可靠性以及线路电容和大过渡电阻的影响。  相似文献   

6.
在超(特)高压输电线路中接入的并联电抗器,可以适当地补偿分布电容所产生的容性电流,降低差动电流,但仍不能保证区外故障时正确动作.本文在传统的分相电流差动保护的基础上,结合电抗器的补偿作用,对传统的补偿方案进行了修正.通过ATP仿真验证,表明该方法具有较高的可靠性.  相似文献   

7.
首先利用动模实验数据验证了线路两相电流差的特性,根据此特性,提出了基于两相电流差和线电压的中低压线路自适应保护方案,该保护方案具有故障类型和运行方式自适应的特点。然后,分析了该自适应速断保护的性能,并与传统电流速断保护、距离保护以及电流闭锁电压速断保护进行分析比较,阐明了该自适应速断保护的优越性。  相似文献   

8.
光伏T接高压配电网电流差动保护研究   总被引:2,自引:1,他引:2       下载免费PDF全文
分析了光伏电站故障电流的特性,研究了两个目前常用电流差动保护判据应用在光伏T接线路上存在的问题。研究结果表明,传统T接线路差动保护判据不能同时满足内部故障的灵敏性和外部故障的可靠性。结合光伏电源故障电流特点,提出了适合于光伏T接线路电流差动保护的综合判据。对改进后的判据进行了大量的仿真试验,仿真结果表明,该判据能满足区内故障时的灵敏性和区外故障时的可靠性,并且具有很强的抗过渡电阻的能力。  相似文献   

9.
在超高压输电线路光纤电流差动保护原理基础上,结合贵州电网近期发生的光纤电流差动保护动作事故,对输电线路光纤电流差动保护误动情况与防范措施进行了较为全面的分析与探讨,为光纤电流差动保护误动事故的预防提供借鉴。  相似文献   

10.
分相电流差动保护装置中一般都配置零序差动保护 ,目的是为了提高保护装置的耐过渡电阻能力。经分析表明 ,零序差动保护并不比故障分量差动保护的灵敏度高 ,并且其整定需躲过外部三相短路时的不平衡电流。零序电流差动保护对整个保护装置的灵敏度和动作速度均没有实质性的提高  相似文献   

11.
李炜 《湖南电力》2005,25(1):19-21
分析了输电线路电容电流存在的原因以及对线路纵联差动保护的影响,并针对电容电流的影响,分析比较了2种补偿方案以及在整定计算中需要注意的问题。  相似文献   

12.
This paper presents a new compensation scheme of low‐dropout regulator (LDO) design over the conventional methodology. With only 0.3 pF on‐chip compensation capacitor, a left‐half‐plane zero is realized within the regulation loop unity‐gain bandwidth and over 56 ° phase margin is achieved under the full range of the load current. The LDO thus achieves stability without using the equivalent series resistance of the capacitor. It is proven experimentally that the proposed LDO has many attractive features such as high accuracy, low quiescent current, and smaller compensation capacitor. The measurement results show that the excellent performance can be comparable with the state of the art LDOs. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
用运算放大器构成压控恒流源的研究   总被引:15,自引:0,他引:15  
从恒流源内阻和形成输出电流误差两个方面,给出用运算放大器构成压控恒流源的分析结果。  相似文献   

14.
为避免广域电流差动保护受电容电流影响而误动的情况发生,通过对传统电流差动保护进行改进,提出一种不受电容电流影响的广域电流差动保护算法。利用微分方程计算出各线路上的电容电流,采用修正的差动电流对暂态和稳态电容电流进行有效补偿,即在传统差动电流基础上减去计算出的电容电流以使电流差动保护不再受电容电流的影响。利用PSCAD仿真实验将改进的广域电流差动保护与传统原理的电流差动保护进行了比较。结果表明,该保护不受电容电流影响,外部故障时可靠不动作,验证了此保护算法的可行性和有效性。  相似文献   

15.
全差分高速低电压锁存比较器的设计   总被引:1,自引:1,他引:1  
全差分锁存比较器在各种模数转换器中有着广泛的应用,其失调电压对于模数转换的精度有着直接的影响。本文提出了一种全差分高速低电压锁存比较器,着重对其失调电压和速度进行了优化。在0.2μm标准CMOSIHP工艺条件下,采用了Cadence Spectre进行了仿真,结果表明,当工作频率为200MHz,供电电压为1.5V,延时仅为1.81ns,失调电压为27.69mV。  相似文献   

16.
变压器在空载合闸的过程中,会产生幅值较大的励磁涌流,如不采取相应的闭锁措施,将导致变压器差动保护误动作。针对该问题,提出了一种基于差流符号序列特征的变压器励磁涌流识别判据。该判据首先对差流序列进行符号化处理,根据符号序列中相关模式序列出现的比例,量化表征差流波形的特征,实现对励磁涌流和故障差流的识别。利用PSCAD/EMTDC仿真软件验证了所提判据在各类区内外故障和励磁涌流工况下,以及各类工况伴随电流互感器饱和时的有效性。  相似文献   

17.
针对特高压系统变压器的特点及对保护带来的问题,通过合理配置差动保护,以及对变压器运行方式的智能识别,细分保护动作特性区间,提出利用短数据窗高比例制动特性来保证在特征明显的区内故障时差动保护的快速动作。该方案已应用于WBH-800变压器保护装置并通过实验验证。  相似文献   

18.
线路电流差动保护的基础是线路的RL集中参数模型和电荷连续性。行波差动保护的基础是线路的分布参数模型和行波传输不变性。针对两类差动保护在电力线路上的应用进行了详细的理论和仿真对比研究。指出二者的根本区别在于行波差动保护考虑了线路的分布参数特性和空间传播特性,而电流差动保护把线路看成节点,完全忽略了分布参数特性和空间传播特性,差动电流是行波差动电流的退化形式。对于特高压长距离输电线路,行波差动保护相比于电流差动保护有明显的性能优势。对于高压和超高压输电线路,行波差动保护和电流差动保护性能无显著差别,电流差动保护可以胜任该类线路。  相似文献   

19.
徐习东  曾平  方愉东 《华东电力》2006,34(8):98-101
数字式变压器差动保护用平衡系数代替了传统保护的平衡线圈.在平衡系数整定中,基本侧选择不同,将直接影响差动保护最小动作电流(差动门槛)的整定.探讨了目前存在的4种基本侧选择方式,并提出了差动门槛整定与基本侧的对应关系,以便更合理地整定不同保护装置的差动门槛.  相似文献   

20.
针对特高压直流系统逆变侧阀侧接地故障可能引发换流变压器故障性涌流的问题,讨论故障位于不同电压等级换流桥以及不同时刻下阀桥通断情况的差异,分析换相失败后阀侧故障电流特征,阐述逆变侧故障性涌流产生机理及其特征。在此基础上,分析计及故障性涌流影响的换流变差动保护动作特性。研究结果表明,故障性涌流可能导致换流变区外转区内故障时差动保护误闭锁,针对该问题,根据故障时阀侧电流直流分量发生极性反转的特点,提出一种新的防止差动保护误闭锁的解决方案。PSCAD/EMTDC仿真结果验证了理论分析的正确性。  相似文献   