The ground-water heat-pump system (GWHP) provides a high efficient way for heating and cooling while consuming a little electrical energy. Due to the lack of scientific guidance for operating control strategy, the coefficient of performance (COP) of the system and units are still very low. In this paper, the running strategy of GWHP was studied. First, the groundwater thermal transfer calculation under slow heat transfixion and transient heat transfixion was established by calculating the heat transfer simulation software Flow Heat and using correction factor. Next, heating parameters were calculated based on the building heat load and the terminal equipment characteristic equation. Then, the energy consumption calculation model for units and pumps were established, based on which the optimization method and constraints were established. Finally, a field test on a GWHP system in Beijing was conducted and the model was applied. The new system operation optimization idea for taking every part of the GWHP into account that put forward in this paper has an important guiding significance to the actual operation of underground water source heat pump.  相似文献   

2.
A heat pump system is the ideal way to extend the heat supply of existing oil or gas fired heating system. Consumption costs are lowered through the use of free energy from the environment, and the dependence on fossils fuels simultaneously reduces. In order to investigate the performance of the solar-ground source heat pump system in the province of Erzurum having cold climate, an experimental set-up was constructed. The experimental apparatus consisted of solar collectors, a ground heat exchanger (GHE), a liquid-to-liquid vapor compression heat pump, water circulating pumps and other measurement equipments. In this study, the performance of the system was experimentally investigated. The experimental results were obtained from October to May of 2008-2009. The experimentally obtained results are used to calculate the heat pump coefficient of performance (COP) and the system performance (COPS). The coefficient of performance of the heat pump and system were found to be in the range of 3.0-3.4 and 2.7-3.0, respectively. This study also shows that this system could be used for residential heating in the province of Erzurum being a cold climate region of Turkey.  相似文献   

3.
Ground-source heat-pump systems provide a new and clean way of heating buildings in the world. They make use of renewable energy stored in the ground, providing one of the most energy-efficient ways of heating buildings. Consumption costs are lowered through the use of free energy from the environment, and the dependence on fossil fuels simultaneously reduces. The aim of this study is to evaluate the performance of vertical ground-source heat-pump system for climatic condition of Erzurum having cold climate in Turkey. For this purpose, an experimental set-up was constructed. The experimental apparatus consisted of a series GHE (ground heat exchanger), a liquid-to-liquid vapor compression heat pump, water circulating pumps and other measurement equipments. In this study, the performance of the system was experimentally investigated. The experimental results were obtained from October to May for the months of heating season of 2008–2009. The experimental results indicate that the average heat-pump COP and overall system’s COPS values are approximately 3.0 and 2.6 in the coldest months of heating season. This study also shows that this system could be used for residential heating in the province of Erzurum being a cold climate region of Turkey.  相似文献   

4.
This paper analyses the performance of a real heat pump plant via methods of entropy generation minimization or finite‐time thermodynamics. The analytical relations between heating load and pressure ratio, and between coefficient of performance (COP) and pressure ratio of real closed regenerated Brayton heat pump cycles coupled to constant‐ and variable‐temperature heat reservoirs are derived. In the analysis, the irreversibilities include heat transfer‐irreversible losses in the hot‐ and cold‐side heat exchangers and the regenerator, the non‐isentropic expansion and compression losses in the compressor and expander, and the pressure drop loss in the pipe and system. The optimal performance characteristics of the cycle may be obtained by optimizing the distribution of heat conductances or heat transfer surface areas among the two heat exchangers and the regenerator, and the matching between working fluid and the heat reservoirs. The influence of the effectiveness of regenerator, the effectiveness of hot‐ and cold‐side heat exchangers, the efficiencies of the expander and compressor, the pressure recovery coefficient and the temperature of the heat reservoirs on the heating load and COP of the cycle are illustrated by numerical examples. Published in 1999 by John Wiley & Sons, Ltd.  相似文献   

5.
As a renewable energy technology, ground source heat pump (GSHP) system is high efficient for heating and cooling in office buildings. However, this technology has strong dependence on the meteorological and building envelope thermal characteristic parameters. For the purpose of quantitative investigation on the feasibility and performance GSHP, three cities located in cold climate zone, Qiqihaer, Shenyang and Beijing, were sampled. Firstly, the office building dynamic loadings in these cities were calculated on basis of the different meteorological and envelope thermal characteristic parameters. The TRNSYS, one kind of energy simulation software, were employed to simulate the operation performances of GSHP on basis of these parameters. The simulation revealed the data on the outlet/inlet temperature of buried pipes, soil temperature, energy consumption distribution and the coefficient of performance (COP) for one year operation. Furthermore, ten years operation was also simulated to show the stability of the performance based on the outlet/inlet temperature of buried pipes and soil temperature. From these results, the GSHP had shown its most suitable performance in Beijing, second in Shenyang and worst in Qiqihaer. These results could be used as a reference on suitable utilization of GSHP systems in office buildings located in cold climate zone, China.  相似文献   

6.
Being environmental friendly and with the potential of energy-efficiency, ground-source heat pump (GSHP) systems are widely used. However, in southern China, there exists large difference between cooling load in summer and heating load in winter. Thus the increase of soil temperature gradually year-by-year will decrease the COP of the GSHP system. In this paper, the configuration of a vertical dual-function geothermal heat exchanger (GHE) used in an integrated soil cold storage and ground-source heat pump (ISCS&GSHP) system, which charged cold energy to the soil at night and produced chilled water at daytime in summer, and supplied hot water for heating in winter, is presented. This is then followed by reporting the development of the mathematical model for the GHE considering the impact of the coupled heat conduction and groundwater advection on the heat transfer between the GHE and its surrounding soil. The GHE model developed was then integrated with a water-source heat pump and a building energy simulation program together for a whole ISCS&GSHP system. Then the operation performance of the ISCS&GSHP system used for a demonstration building is studied. These simulation results indicated the system transferred 71.505% of the original power consumption at daytime to that at nighttime for the demonstration building. And the net energy exchange in the soil after one-year operation was only 2.28% of the total cold energy charged. Thus we can see the feasibility of the ISCS&GSHP system technically.  相似文献   

7.
This paper presents the thermodynamic and hydrodynamic feasibility of the application of the ammonia–water absorption system for heat or cold transportation over long distance. A model of a long‐distance heat energy transportation system is built and analyzed, and it shows satisfactory and attractive results. When a steam heat source at the temperature of 120°C is available, the user site can get hot water output at about 55°C with the thermal COP of about 0.6 and the electric COP of about 100 in winter, and cold water output at about 8°C with the thermal COP of about 0.5 and the electric COP of 50 in summer. A small‐size prototype is built to verify the performance analysis. Basically the experimental data show good accordance with the analysis results. The ammonia–water absorption system is a potential prospective solution for the heat or cold transportation over long distance. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
以大连市某商场为例,采用BIN方法计算了水源热泵系统全年建筑负荷及能耗,在此基础上,与传统区域供热和冷冻机制冷方案进行了经济性比较。结果表明,地下水源热泵系统尽管在初投资方面比传统方案高约18.5%,但年运行费用大大减小,费用年值较传统方案减少了19%,节能性能良好,追加投资回收期仅为3年。  相似文献   

9.
To increase the driving range of electric vehicles in cold climate, air conditioning heat pump (ACHP) system is supposed to be the most effective solution. Working near 0°C with high humidity, the microchannel outdoor heat exchanger (OHX) in system would experience badly frosting process, like traditional residential heat pump system. It would lead to a significant reduction of system performance without defrosting in time. In this article, experimental investigation has been implemented on the frosting process of ACHP system of electric vehicles which is with a microchannel OHX. The phenomenon of frosting distribution was observed, the frosted part on surface shows uneven with various flows paths. The typical frosting characteristics of an outdoor microchannel heat exchanger were also obtained. In a self-designed three-heat exchanger ACHP system, the inlet and outlet refrigerant temperature of OHX as well as the outlet air temperature of system decrease with increasing frosting coverage rate. The frosting phenomenon was analyzed with variation of ambient temperature and humidity. System influence by frosting was also studied with under different ambient conditions. When OHX begins to frost, the heating capacity reduction of system under different ambient conditions were both increased but the differences in the coefficient of performance (COP) variations under different ambient conditions were small as frosting progressed.  相似文献   

10.
Heat pump systems are recognized to be outstanding heating, cooling and water heating systems. They provide high levels of comfort as well as offering significant reductions in electrical energy use. In addition, they have very low levels of maintenance requirements and are environmentally attractive. The purpose of this study is to evaluate the experimentally performance and energy analysis of vertical ground-source heat pump (GSHP) for winter climatic condition of Erzurum, Turkey. For this aim, an experimental analysis was performed on GSHP system made up in the Energy Laboratory in the campus of Ataturk University. The experimental apparatus consisted of a ground heat exchanger, the depth of which was 53 m, a liquid-to-liquid vapor compression heat pump, water circulating pumps and other measurement and control equipments. Tests were performed under laboratory conditions for space heating, in which experimental results were obtained during January–May within the heating season of 2007. The experimentally obtained results were used to calculate the heat pump coefficient of performance (COP) and the system performance (COPs). The COP and COPs were found to be in the range of 2.43–3.55 and 2.07–3.04, respectively. This study also shows that the system proposed could be used for residential heating in the province of Erzurum which is one of the coldest climate region of Turkey.  相似文献   

11.
Air (reverse Brayton) cycle has promising features in cold climate heat pump applications. In this study, an air cycle heat pump water heater (ACHPWH) simulation model considering the off-design performance of components was developed and validated with experimental data from literature. With this model, the performance of ACHPWH was numerically compared with two typical vapor compression heat pump water heaters (VCHPWH) under two different heating schemes, namely instantaneous heating and recirculation heating. For instantaneous heating, the COP of ACHPWH is comparable to that of VCHPWH when supplying high temperature water or operating at low ambient temperature. A significant improvement on annual performance would be achieved as well if higher efficient compressor and expander were applied in ACHPWH system. For recirculation heating, although the COP gap got larger, ACHPWH would save plenty of heating time when operating at low ambient temperature.  相似文献   

12.
This article experimentally investigates the enhancement of thermal performance for an air conditioning system utilizing a cold storage unit as a subcooler. The cold storage unit is composed of an energy storage tank, liquid-side heat exchanger, suction-side heat exchanger and energy storage material (ESM), water. When the cooling load is lower than the nominal cooling capacity of the system, the cold storage unit can store extra cold energy of the system to subcool the condenser outlet refrigerant. Hence, both the cooling capacity and coefficient of performance (COP) of the system will be increased. This experiment tests the two operation modes: subcooled mode with energy storage and non-subcooled mode without energy storage. The results show that for fixed cooling loads at 3.05 kW, 3.5 kW and 3.95 kW, the COP of the subcooled mode are 16.0%, 15.6% and 14.1% higher than those of the non-subcooled mode, respectively. In the varied cooling load experiments, the COP of the subcooled cold storage air conditioning system is 15.3% higher than the conventional system.  相似文献   

13.
以某拟建地下水源热泵系统为例,针对地缘热泵空调系统工作井优化布设问题,通过建立理想的对井抽-灌概念及数学模型,模拟了特定水流及热源条件下抽水、回灌井不同间距夏季运行期间地下水热量运移过程.数值模拟结果表明,抽、灌井不同井间距对热泵系统夏季运行期间地下水热量运移过程影响显著,该方法为优化布设抽、灌井的合理间距提供了实现热泵系统良好运行的理论依据.  相似文献   

14.
In this paper, the effect of various system parameters on horizontal ground source compression refrigeration machine (CRM) performance is studied experimentally in Bursa, Turkey. A ground heat exchanger (GHE) system connected to CRM in a test room in the air conditioning and refrigeration laboratory of Uludag University has been designed and constructed. This system was tested for space cooling in August and September 2004 and performance tests were performed during this period. Overall, system mainly consists of the GHE (GHE–water circuit) and CRM (CRM–refrigerant circuit). Refrigerant is R134a. Hourly variations of inlet and outlet water temperatures, extracted heat from test room, rejected heat to ground, compression ratio, total power consumption, and coefficient of performance (COP) values for both whole system and only CRM are obtained. Thermal properties of soil are also estimated by using experimental data and theory. Cooling load of test room and rejected heat to ground, and all COP values are also presented. Finally, heat rejection rate to ground with respect to leaving water temperature from GHE is given. The COP of the overall system changes between 2 and 2.5, also CRM COP values are in the range of 3 and 3.86. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

15.
An absorption system can be used for space cooling as well as for space heating. This dual purpose may be achieved by using the system as heat pump in wintertime. Absorption heat pump heating may be an interesting alternative, particularly for countries where there is a shortage of electric power.When an absorption unit is used as heat pump, its mode of operation is not modified: the internal temperatures of the cycle are only raised. Commercially available LiBr units were tested as heat pumps. COP and heating capacity were considered as a function of cold source temperature for different temperatures of the useful heat. The COP arrived at 1.7, which must be considered a high value for a thermally driven heat pump.Simulations were carried out in order to compare the performance of “conventional” solar, solar assisted heat pump and the combined series system under two different climate conditions. The series system showed performance 25–75 per cent better than “conventional” solar alone.  相似文献   

16.
Huge amount of energies is consumed by the air conditioning (A/C) to maintain the required temperature and humidity inside spaces/applications of high humidly. An innovative A/C system that recovers the condenser heat in process air reheating and other useful thermal utilization is presented and investigated in this paper. For high coefficient of performance (COP) of the AC and more energy‐efficient system, the cold exhaust air rejected by the air condition system is also utilized to cool the condenser of the AC system. Huge amount of the water condensate from the system is also utilized as freshwater production. Performance of the proposed system is analytically investigated for different operating conditions and system capacities. Mathematical model of the systems is developed and solved numerically using Engineering Equation Solver (EES) software. Results show that the proposed system enhances the COP and decreases the electric power consumption. The saving in electric power consumption, COP, and the freshwater production rate of the system increases with decreasing room‐sensible heat factor, fresh air ratio, and outdoor air temperature and humidity. Moreover, the COP of the proposed system is 90% higher than COP of the basis system, and the savings in the running cost of the system increase by 4.5 times with decreasing the room‐sensible heat factor (RSHF) from 0.6 to 0.2. In addition, the highest COP attained by the proposed system is 2.72, and the corresponding freshwater production rate is 373.8 kg/h.  相似文献   

17.
以天津地区一项太阳能地源热泵系统工程实例为研究对象,针对其太阳能储热利用率较低的问题提出了将其两个地埋管群互通互联的解决方案。通过对每个系统进行20年的模拟预测,发现采用了互通互联的两个系统储热利用率较原系统有所增加,系统COP得到了提升。双机组双地埋管群系统运行20年的平均COP可达3.54,单机组双地埋管群系统运行20年的平均COP可达3.36,分别比双机组独立地埋管群系统提高7.9%和2.4%。双地埋管群的改造方案的优越性明显,为太阳能地源热泵系统的应用提供借鉴。  相似文献   

18.
An experimental study is performed to determine the performance of a ground source heat pump (GSHP) system in the heating mode in the city of Erzurum, Turkey. The GSHP system using R‐134a as refrigerant has a single U‐tube ground heat exchanger (GHE) made of polyethylene pipe with a 16 mm inside diameter. The GHE was placed in a vertical borehole with 55 m depth and 203.2 mm diameter. The average coefficients of performance (COP) of the GSHP system and heat pump in heating mode are calculated as 2.09 and 2.57, respectively. The heat extraction rate per meter of the borehole is determined as 33.60 W m?1. Considering the current gas and electric prices in Erzurum city, the equivalent COP of the GSHP system should be 2.92 for the same energy cost comparing with natural gas. The virgin ground in Erzurum basin has high permeability and low thermal conductivity. In order to improve the thermal efficiency of GHE and thus improve COP of a GSHP in the basin, the borehole should be backfilled with sand as low‐cost backfill material and a 1 to 2 m thick surface plug of clay should be inserted. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

19.
寒冷地区太阳能-土壤源热泵系统运行方式的探讨   总被引:12,自引:7,他引:12  
在太阳能—土壤源热泵系统中,合理确定其运行工况,对系统运行的经济性、可靠性具有重要意义。该文对寒冷地区太阳能热泵系统在各种运行工况的运行特性及太阳能—土壤源热泵系统在各种运行方式下的运行时间分配比例进行理论研究,为太阳能—土壤源热泵系统的设计、运行管理提供参考。  相似文献   

20.
针对由天气变化导致太阳能利用不稳定和寒冷地区热泵性能低的问题,文章介绍了一种基于相变储能的太阳能空气源热泵系统,该系统能够根据气象情况灵活切换4种供暖模式,大大减少了系统耗电量。文章通过独特设计的储能冷凝器,不仅可以调节太阳能空气源热泵系统能量分配,改善太阳能空气源热泵系统制热量和建筑热负荷之间不平衡的供需关系、提高太阳能利用率,还可以提高空气源热泵低温性能,快速恢复供暖,从而实现提高太阳能空气源热泵系统整体性能的目的。文章以石家庄农村某户为研究对象进行研究,研究结果表明,太阳能空气源热泵系统供暖效果较好,太阳能空气源热泵系统COP最大值为5.19,节能环保效益十分明显。  相似文献   