首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 215 毫秒
1.
In this work, we proposed and built a multimodal optical setup that extends a commercially available confocal microscope (Olympus VF300) to include nonlinear second harmonic generation (SHG) and third harmonic generation (THG) optical (NLO) microscopy and fluorescence lifetime imaging microscopy (FLIM). We explored all the flexibility offered by this commercial confocal microscope to include the nonlinear microscopy capabilities. The setup allows image acquisition with confocal, brightfield, NLO/multiphoton and FLIM imaging. Simultaneously, two‐photon excited fluorescence (TPEF) and SHG are well established in the biomedical imaging area, because one can use the same ultrafast laser and detectors set to acquire both signals simultaneously. Because the integration with FLIM requires a separated modulus, there are fewer reports of TPEF+SHG+FLIM in the literature. The lack of reports of a TPEF+SHG+THG+FLIM system is mainly due to difficulties with THG because the present NLO laser sources generate THG in an UV wavelength range incompatible with microscope optics. In this article, we report the development of an easy‐to‐operate platform capable to perform two‐photon fluorescence (TPFE), SHG, THG, and FLIM using a single 80 MHz femtosecond Ti:sapphire laser source. We described the modifications over the confocal system necessary to implement this integration and verified the presence of SHG and THG signals by several physical evidences. Finally, we demonstrated the use of this integrated system by acquiring images of vegetables and epithelial cancer biological samples. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

2.
Multiphoton microscopy is widely employed in the life sciences using extrinsic fluorescence of low‐ and high‐molecular weight labels with excitation and emission spectra in the visible and near infrared regions. For imaging of intrinsic and extrinsic fluorophores with excitation spectra in the ultraviolet region, multiphoton excitation with one‐ or two‐colour lasers avoids the need for ultraviolet‐transmitting excitation optics and has advantages in terms of optical penetration in the sample and reduced phototoxicity. Excitation and detection of ultraviolet emission around 300 nm and below in a typical inverted confocal microscope is more difficult and requires the use of expensive quartz optics including the objective. In this technical note we describe the adaptation of a commercial confocal microscope (Nikon, Japan E‐C1 or E‐C2) for versatile use with Ti‐sapphire and OPO laser sources and the addition of a second detection channel that enables detection of ultraviolet fluorescence and increases detection sensitivity in a typical fluorescence lifetime imaging microscopy experiment. Results from some experiments with this setup illustrate the resulting capabilities.  相似文献   

3.
A variety of high resolution optical microscopy techniques have been developed in recent years for basic and clinical studies of biological systems. We demonstrate a trimodal microscope combining optical coherence microscopy (OCM) with two forms of nonlinear microscopy, namely two-photon excited fluorescence (2PF) and second harmonic generation (SHG), for imaging turbid media. OCM combines the advantages of confocal detection and coherence gating for structural imaging in highly scattering tissues. Nonlinear microscopy enables the detection of biochemical species, such as elastin, NAD(P)H, and collagen. While 2PF arises from nonlinear excitation of fluorescent species, SHG is a form of nonlinear scattering observed in materials that lack a center of inversion symmetry, such as type I collagen. Characterization of the microscope showed nearly diffraction-limited spatial resolution in all modalities. Images were obtained in fish scales and excised human skin samples. The primary endogenous sources of contrast in the dermis were due to elastin autofluorescence and collagen SHG. Multimodal microscopy allows the simultaneous visualization of structural and functional information of biological systems.  相似文献   

4.
Automated microscopy system for mosaic acquisition and processing   总被引:2,自引:2,他引:0  
An automatic mosaic acquisition and processing system for a multiphoton microscope is described for imaging large expanses of biological specimens at or near the resolution limit of light microscopy. In a mosaic, a larger image is created from a series of smaller images individually acquired systematically across a specimen. Mosaics allow wide‐field views of biological specimens to be acquired without sacrificing resolution, providing detailed views of biological specimens within context. The system is composed of a fast‐scanning, multiphoton, confocal microscope fitted with a motorized, high‐precision stage and custom‐developed software programs for automatic image acquisition, image normalization, image alignment and stitching. Our current capabilities allow us to acquire data sets comprised of thousands to tens of thousands of individual images per mosaic. The large number of individual images involved in creating a single mosaic necessitated software development to automate both the mosaic acquisition and processing steps. In this report, we describe the methods and challenges involved in the routine creation of very large scale mosaics from brain tissue labelled with multiple fluorescent probes.  相似文献   

5.
Multiphoton microscopy has become a novel biological imaging technique that allows cellular and subcellular microstructure imaging based on two‐photon excited fluorescence and second harmonic generation. In this work, we used multiphoton microscopy to obtain the high‐contrast images of human normal breast tissue and two main histologic types of fibroadenoma (intracanalicular, pericanalicular). Moreover, quantitative image analysis was performed to characterize the changes of collagen morphology (collagen content, collagen orientation). The results show that multiphoton microscopy combined with quantitative method has the ability to identify the characteristics of fibroadenoma including changes of the duct architecture and collagen morphology in stroma. With the advancement of multiphoton microscopy, we believe that the technique has great potential to be a real‐time histopathological diagnostic tool for intraoperative detection of fibroadenoma in the future.  相似文献   

6.
Standardization and calibration of optical microscopy systems have become an important issue owing to the increasing role of biological imaging in high‐content screening technology. The proper interpretation of data from high‐content screening imaging experiments requires detailed information about the capabilities of the systems, including their available dynamic range, sensitivity and noise. Currently available techniques for calibration and standardization of digital microscopes commonly used in cell biology laboratories provide an estimation of stability and measurement precision (noise) of an imaging system at a single level of signal intensity. In addition, only the total noise level, not its characteristics (spectrum), is measured. We propose a novel technique for estimation of temporal variability of signal and noise in microscopic imaging. The method requires registration of a time series of images of any stationary biological specimen. The subsequent analysis involves a multi‐step process, which separates monotonic, periodic and random components of every pixel intensity change in time. The technique allows simultaneous determination of dark, photonic and multiplicative components of noise present in biological measurements. Consequently, a respective confidence interval (noise level) is obtained for each level of signal. The technique is validated using test sets of biological images with known signal and noise characteristics. The method is also applied to assess uncertainty of measurement obtained with two CCD cameras in a wide‐field microscope.  相似文献   

7.
Thin, uniformly fluorescing reference layers can be used to characterize the imaging conditions in confocal, or more general, sectioning microscopy. Through-focus datasets of such layers obtained by standard microscope routines provide the basis for the approach. A set of parameters derived from these datasets is developed for defining a number of relevant sectioned imaging properties. The main characteristics of a particular imaging situation can then be summarized in a Sectioned Imaging Property-chart or SIPchart. We propose the use of such charts for the characterization of imaging properties in confocal and multiphoton microscopy. As such, they can be the basis for comparison of sectioned imaging condition characteristics, quality control, maintenance or reproduction of sectioned imaging conditions and other applications. Such charts could prove useful in documenting the more relevant properties of the instrumentation used in microscopy studies. The method carries the potential to provide the basis for a general characterization of sectioned imaging conditions as the layers employed can be characterized and fabricated to standard specifications. A limited number of such thin, uniformly fluorescing layers is available from our group for this purpose. Extension of the method to multiphoton microscopy is discussed.  相似文献   

8.
The fluorescence photobleaching method has been widely used to study molecular transport in single living cells and other microsystems while confocal microscopy has opened new avenues to high-resolution, three-dimensional imaging. A new technique, scanning microphotolysis (Scamp), combines the potential of photobleaching, beam scanning and confocal imaging. A confocal scanning laser microscope was equipped with a sufficiently powerful laser and a novel device, the ‘Scamper’. This consisted essentially of a filter changer, an acousto-optical modulator (AOM) and a computer. The computer was programmed to activate the AOM during scanning according to a freely defined image mask. As a result almost any desired pattern could be bleached (‘written’) into fluorescent samples at high definition and then imaged (‘read’) at non-bleaching conditions, employing full confocal resolution. Furthermore, molecular transport could be followed by imaging the dissipation of bleach patterns. Experiments with living cells concerning dynamic processes in cytoskeletal filaments and the lateral mobility of membrane lipids suggest a wide range of potential biological applications. Thus, Scamp offers new possibilities for the optical manipulation and analysis of both technical and biological microsystems.  相似文献   

9.
We present a custom-designed atomic force fluorescence microscope (AFFM), which can perform simultaneous optical and topographic measurements with single molecule sensitivity throughout the whole visible to near-infrared spectral region. Integration of atomic force microscopy (AFM) and confocal fluorescence microscopy combines the high-resolution topographical imaging of AFM with the reliable (bio)-chemical identification capability of optical methods. The AFFM is equipped with a spectrograph enabling combined topographic and fluorescence spectral imaging, which significantly enhances discrimination of spectroscopically distinct objects. The modular design allows easy switching between different modes of operation such as tip-scanning, sample-scanning or mechanical manipulation, all of which are combined with synchronous optical detection. We demonstrate that coupling the AFM with the fluorescence microscope does not compromise its ability to image with a high spatial resolution. Examples of several modes of operation of the AFFM are shown using two-dimensional crystals and membranes containing light-harvesting complexes from the photosynthetic bacterium Rhodobacter sphaeroides.  相似文献   

10.
Highly optically active nonlinear bio‐photonic crystalline and semicrystalline structures in living cells were studied by a novel multimodal nonlinear microscopy. Numerous biological structures, including stacked membranes and aligned protein structures are highly organized on a nanoscale and have been found to exhibit strong optical activities through second‐harmonic generation (SHG) interactions, behaving similarly to man‐made nonlinear photonic crystals. The microscopic technology used in this study is based on a combination of different imaging modes including SHG, third‐harmonic generation, and multiphoton‐induced fluorescence. With no energy release during harmonic generation processes, the nonlinear‐photonic‐crystal‐like SHG activity is useful for investigating the dynamics of structure–function relationships at subcellular levels and is ideal for studying living cells, as minimal or no preparation is required.  相似文献   

11.
Spectrofluorometric imaging microscopy is demonstrated in a confocal microscope using a supercontinuum laser as an excitation source and a custom‐built prism spectrometer for detection. This microscope system provides confocal imaging with spectrally resolved fluorescence excitation and detection from 450 to 700 nm. The supercontinuum laser provides a broad spectrum light source and is coupled with an acousto‐optic tunable filter to provide continuously tunable fluorescence excitation with a 1‐nm bandwidth. Eight different excitation wavelengths can be simultaneously selected. The prism spectrometer provides spectrally resolved detection with sensitivity comparable to a standard confocal system. This new microscope system enables optimal access to a multitude of fluorophores and provides fluorescence excitation and emission spectra for each location in a 3D confocal image. The speed of the spectral scans is suitable for spectrofluorometric imaging of live cells. Effects of chromatic aberration are modest and do not significantly limit the spatial resolution of the confocal measurements.  相似文献   

12.
We compare the axial sectioning capability of multifocal confocal and multifocal multiphoton microscopy in theory and in experiment, with particular emphasis on the background arising from the cross‐talk between adjacent imaging channels. We demonstrate that a time‐multiplexed non‐linear excitation microscope exhibits significantly less background and therefore a superior axial resolution as compared to a multifocal single‐photon confocal system. The background becomes irrelevant for thin (< 15 µm) and sparse fluorescent samples, in which case the confocal parallelized system exhibits similar or slightly better sectioning behaviour due to its shorter excitation wavelength. Theoretical and experimental axial responses of practically implemented microscopes are given.  相似文献   

13.
Fluorescence microscopy techniques have become important tools in mitosis research. The well-known disadvantages of fluorescence microscopy, rapid bleaching, phototoxicity and out-of-focus contributions blurring the in-focus image are obstacles which still need to be overcome. Confocal fluorescence microscopy has the potential to improve our capabilities of analyzing cells, because of its excellent depth-discrimination and image processing power. We have been using a confocal fluorescence microscope for the study of the mechanism of poleward chromosome movement, and report here (1) a cell preparation technique, which allows labeling of fixation sensitive spindle antigens with acceptable microtubule preservation; (2) the use of image processing methods to represent the spatial distribution of various labeled elements in pseudocolour; (3) a novel immunoelectron microscopic labeling method for microtubules, which allows the visualization of their distribution in semithin sections at low magnification; and (4) a first attempt to study microtubule dynamics with a confocal fluorescence microscope in living cells, microinjected with rhodamine labeled tubulin. Our experience indicates that confocal fluorescence microscopy provides real advantages for the study of spatial colocalization of antigens in the mitotic spindle. It does not, however, overcome the basic limits of resolution of the light microscope. Therefore, it has been necessary to use an electron microscopic method. Our preliminary results with living cells show that it is possible to visualize the entire microtubule network in stereo, but that the sensitivity of the instrument is still too low to perform dynamic time studies. It will be worthwhile to further develop this new type of optical instrumentation and explore its usefulness on both fixed and living cells.  相似文献   

14.
Multiphoton microscopy in life sciences   总被引:13,自引:1,他引:12  
Near infrared (NIR) multiphoton microscopy is becoming a novel optical tool of choice for fluorescence imaging with high spatial and temporal resolution, diagnostics, photochemistry and nanoprocessing within living cells and tissues. Three‐dimensional fluorescence imaging based on non‐resonant two‐photon or three‐photon fluorophor excitation requires light intensities in the range of MW cm?2 to GW cm?2, which can be derived by diffraction limited focusing of continuous wave and pulsed NIR laser radiation. NIR lasers can be employed as the excitation source for multifluorophor multiphoton excitation and hence multicolour imaging. In combination with fluorescence in situ hybridization (FISH), this novel approach can be used for multi‐gene detection (multiphoton multicolour FISH). Owing to the high NIR penetration depth, non‐invasive optical biopsies can be obtained from patients and ex vivo tissue by morphological and functional fluorescence imaging of endogenous fluorophores such as NAD(P)H, flavin, lipofuscin, porphyrins, collagen and elastin. Recent botanical applications of multiphoton microscopy include depth‐resolved imaging of pigments (chlorophyll) and green fluorescent proteins as well as non‐invasive fluorophore loading into single living plant cells. Non‐destructive fluorescence imaging with multiphoton microscopes is limited to an optical window. Above certain intensities, multiphoton laser microscopy leads to impaired cellular reproduction, formation of giant cells, oxidative stress and apoptosis‐like cell death. Major intracellular targets of photodamage in animal cells are mitochondria as well as the Golgi apparatus. The damage is most likely based on a two‐photon excitation process rather than a one‐photon or three‐photon event. Picosecond and femtosecond laser microscopes therefore provide approximately the same safe relative optical window for two‐photon vital cell studies. In labelled cells, additional phototoxic effects may occur via photodynamic action. This has been demonstrated for aminolevulinic acid‐induced protoporphyrin IX and other porphyrin sensitizers in cells. When the light intensity in NIR microscopes is increased to TW cm?2 levels, highly localized optical breakdown and plasma formation do occur. These femtosecond NIR laser microscopes can also be used as novel ultraprecise nanosurgical tools with cut sizes between 100 nm and 300 nm. Using the versatile nanoscalpel, intracellular dissection of chromosomes within living cells can be performed without perturbing the outer cell membrane. Moreover, cells remain alive. Non‐invasive NIR laser surgery within a living cell or within an organelle is therefore possible.  相似文献   

15.
Fibre-optic nonlinear optical microscopy and endoscopy   总被引:1,自引:0,他引:1  
L. FU  & M. GU 《Journal of microscopy》2007,226(3):195-206
Nonlinear optical microscopy has been an indispensable laboratory tool of high‐resolution imaging in thick tissue and live animals. Rapid developments of fibre‐optic components in terms of growing functionality and decreasing size provide enormous opportunities for innovations in nonlinear optical microscopy. Fibre‐based nonlinear optical endoscopy is the sole instrumentation to permit the cellular imaging within hollow tissue tracts or solid organs that are inaccessible to a conventional optical microscope. This article reviews the current development of fibre‐optic nonlinear optical microscopy and endoscopy, which includes crucial technologies for miniaturized nonlinear optical microscopy and their embodiments of endoscopic systems. A particular attention is given to several classes of photonic crystal fibres that have been applied to nonlinear optical microscopy due to their unique properties for ultrashort pulse delivery and signal collection. Furthermore, fibre‐optic nonlinear optical imaging systems can be classified into portable microscopes suitable for imaging behaving animals, rigid endoscopes that allow for deep tissue imaging with minimally invasive manners, and flexible endoscopes enabling imaging of internal organs. Fibre‐optic nonlinear optical endoscopy is coming of age and a paradigm shift leading to optical microscope tools for early cancer detection and minimally invasive surgery.  相似文献   

16.
The bilateral scanning approach to confocal microscopy is characterized by the direct generation of the image on a two-dimensional (2-D) detector. This detector can be a photographic plate, a CCD detector or the human eye, the human eye permitting direct visualization of the confocal image. Unlike Nipkow-type systems, laser light sources can be used for excitation. A design called a carousel has been developed, in which the bilateral confocal scan capability can be added to an existing microscope so that rapid exchange and comparison between confocal and non-confocal imaging conditions is possible. The design permits independent adjustment of confocal sectioning properties with lateral resolutions better than, or, in the worst case equivalent to, those available in conventional microscopy. The carousel can be considered as a stationary optical path in which certain imaging conditions, such as confocality, are defined and operate on part of the imaging field. The action of the bilateral scan mirror then extends this image condition over the whole field. A number of optical arrangements for the carousel are presented which realize various forms of confocal fluorescence and reflection imaging, with point, multiple point or slit confocal detection arrangements. Through the addition of active elements to the carousel direct stereoscopic, ratio, time-resolved and other types of imaging can be achieved, with direct image formation on a CCD, eye or other 2-D detectors without the need to modify the host microscope. Depending on the photon flux available, these imaging modes can run in real-time or can use a cooled CCD at (very) low light level for image integration over an extended period.  相似文献   

17.
Using an optical system made from fused silica catalogue optical components, third‐order nonlinear microscopy has been enabled on conventional Ti:sapphire laser‐based multiphoton microscopy setups. The optical system is designed using two lens groups with straightforward adaptation to other microscope stands when one of the lens groups is exchanged. Within the theoretical design, the optical system collects and transmits light with wavelengths between the near ultraviolet and the near infrared from an object field of at least 1 mm in diameter within a resulting numerical aperture of up to 0.56. The numerical aperture can be controlled with a variable aperture stop between the two lens groups of the condenser. We demonstrate this new detection capability in third harmonic generation imaging experiments at the harmonic wavelength of ~300 nm and in multimodal nonlinear optical imaging experiments using third‐order sum frequency generation and coherent anti‐Stokes Raman scattering microscopy so that the wavelengths of the detected signals range from ~300 nm to ~660 nm.  相似文献   

18.
Advances in laser sources for confocal and multiphoton microscopy   总被引:1,自引:0,他引:1  
The illumination source for all high-resolution, optical sectioning, scanning microscopes is crucially important to the overall performance of the system. We examine advances that have been made in laser sources for both confocal and multiphoton microscopy where the emphasis has been on the development of potentially low-cost, easy to use sources. Growing interest in temporally and spatially resolved techniques has directed laser research towards addressing these challenges. We present the most recent developments in sources for confocal and multiphoton microscopy along with the considerations that should be made when a new source is being considered.  相似文献   

19.
Multiphoton excitation was originally projected to improve live cell fluorescence imaging by minimizing photobleaching effects outside the focal plane, yet reports suggest that photobleaching within the focal plane is actually worse than with one photon excitation. We confirm that when imaging enhanced green fluorescent protein, photobleaching is indeed more acute within the multiphoton excitation volume, so that whilst fluorescence increases as predicted with the square of the excitation power, photobleaching rates increase with a higher order relationship. Crucially however, multiphoton excitation also affords unique opportunities for substantial improvements to fluorescence detection. By using a Pockels cell to minimize exposure of the specimen together with multiple nondescanned detectors we show quantitatively that for any particular bleach rate multiphoton excitation produces significantly more signal than one photon excitation confocal microscopy in high resolution Z‐axis sectioning of thin samples. Both modifications are readily implemented on a commercial multiphoton microscope system.  相似文献   

20.
Super‐resolution optical microscopy techniques have revolutionized how we see and understand biology. In recent past, a new super‐resolution optical microscopy technique called expansion microscopy (ExM) was developed. Unlike other pre‐existing super‐resolution imaging techniques, this technique achieves super‐resolution by physically expanding biological specimens via a swellable hydrogel. After the development of ExM, various techniques based on ExM but with improved performance in various aspects, have been developed. In this review, we introduce the basic principles of ExM and its variants. and compare the advantages and disadvantages of these techniques. In addition, we present the applications of ExM techniques in various fields.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号