首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Saad OM  Leary JA 《Analytical chemistry》2003,75(13):2985-2995
A new method using a combination of electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MSn) was developed for the identification and quantitative analysis of eight heparan sulfate (HS)- and heparin-derived delta-disaccharides obtained by enzymatic depolymerization. The compositional analysis of nonisomeric disaccharide constituents of heparin/HS was achieved from full-scan MS1 spectra using an internal standard and a calculated response factor for each disaccharide. Diagnostic product ions from MSn spectra of isomeric disaccharides were used for the quantitative analysis of the relative amounts of each of the isomers in mixtures. The protocol was validated using several quality control samples and showed satisfactory accuracy and precision. The analysis is rapid, accurate, and uses no purification or separation steps prior to analysis by MS, thus reducing sample consumption and analysis time of traditional methods. Using this quantitative analysis procedure, percentages of disaccharide compositions for heparins from porcine and bovine intestinal mucosa and heparan sulfate from bovine kidney were determined.  相似文献   

2.
Glycosaminoglycans heparin and heparan sulfate are biologically active polysulfated carbohydrates that are among the most challenging biopolymers with regards to their structural analysis and functional assessment. Fragmentation of oligosaccharides and sulfate loss are important hindrance to their analysis by mass spectrometry (MS), requiring thus soft ionization methods. The recently introduced soft ionization method desorption electrospray ionization (DESI) has been applied here to heparin and heparan sulfate oligosaccharides, showing that DESI-MS is well suited for the detection of such fragile biomolecules in their intact form. Characterization of complicated oligosaccharides such as synthetic heparin octadecasulfated dodecasaccharide was successfully achieved. The use of water for a spray solvent instead of denaturing organic solvents allowed the first DESI-MS detection of noncovalent biomolecular complexes between heparin oligosaccharides and the chemokine Stromal Cell-derived Factor-1. The hyphenation of the DESI ion source with the high-resolution LTQ-Orbitrap MS analyzer led to high accuracy of mass measurement and enabled unambiguous determination of the protein-bound sulfated oligosaccharide.  相似文献   

3.
A method for the determination of underivatized amino acids based on capillary electrophoresis coupled to electrospray ionization mass spectrometry (CE-ESI-MS) is described. To analyze free amino acids simultaneously a low acidic pH condition was used to confer positive charge on whole amino acids. The choice of the electrolyte and its concentration influenced resolution and peak shape of the amino acids, and 1 M formic acid was selected as the optimal electrolyte. Meanwhile, the sheath liquid composition had a significant effect on sensitivity and the highest sensitivity was obtained when 5 mM ammonium acetate in 50% (v/v) methanol-water was used. Protonated amino acids were roughly separated by CE and selectively detected by a quadrupole mass spectrometer with a sheath flow electrospray ionization interface. Under the optimized conditions, 19 free amino acids normally found in proteins and several physiological amino acids were well determined in less than 17 min. The detection limits for basic amino acids were between 0.3 and 1.1 mumol/L and for acidic and low molecular weight amino acids were less than 6.0 mumol/L with pressure injection of 50 mbar for 3 s (3 nL) at a signal-to-noise ratio of 3. This method is simple, rapid, and selective compared with conventional techniques and could be readily applied to the analysis of free amino acids in soy sauce.  相似文献   

4.
Electrospray ionization mass spectrometry (ESI-MS) was applied for the characterization of inorganic polyphosphates [orthophosphate, pyrophosphate, tripolyphosphate, trimetaphosphate, and tetrapolyphosphatel. The high selectivity of ESI-MS allows the detection of different polyphosphate species without preseparation by ion chromatography or capillary electrophoresis. Furthermore, ESI-MS does not require the incorporation of UV-absorbing chromophores into the analytical method for the detection of phosphates, unlike conventional UV-chromatographic methods. Limits of detection by ESI-MS were estimated to range from approximately 1 to 10 ng/mL. The quantification of polyphosphate samples as single-component and multicomponent mixtures was investigated. Linear signal response for single-component samples ranged from the limit of detection to approximately 10 microg/mL Quantification of polyphosphate in streamwater is demonstrated using the standard addition method. The effect of multi-polyphosphate components and salts on signal response was also studied. For concentrations less than 2.0 microg/mL, signal response from a tetrapolyphosphate sample was comparable to those obtained from tetrapolyphosphate-tripolyphosphate mixtures. Signal response obtained from tetrapolyphosphate in the presence of tripolyphosphate or NH4NO3 at higher concentrations (approximately 50 microg/mL and 35 microg/mL, respectively) was significantly lower relative to single-component standards (approximately 40%-70%).  相似文献   

5.
Lu Y  Zhou TF  Shui TW  Bian TL  Guo TY  Yang P 《Analytical chemistry》2001,73(19):4748-4753
Pulsed electrospray has been developed and been reported for the first time. This new technique is based on the principle of pulsed ion sources, combined with the conventional electrospray. The pulsed ion spray was realized by a homemade pulsed HV circuit and was monitored by a digital microscope and an oscilloscope. Results show that the pulsed ESI device can be operated under proper conditions for a clear on-and-off spray process and that the device was kept in good electric contact for electrospray when pulsed HV was on. A pulsed ion current and pulsed mass spectra can be achieved with this pulsed ESI device. Furthermore, it has been noted that, under the same conditions (i.e., shape and size of sprayer tip, distance from sprayer tip to sampling nozzle, and other parameters for mass spectrometer), stable electrospray could be obtained for lower flow rates with a pulsed spray device. This experimental fact indicates the possible reduction in the total sample consumed could be realized by exploiting this novel design.  相似文献   

6.
Charge reduction electrospray mass spectrometry   总被引:3,自引:0,他引:3  
A new mass spectrometric technique, charge reduction electrospray mass spectrometry (CREMS), allowing the analysis of complex mixtures of biological molecules is described. The charge state of ions produced by electrospray ionization may be reduced in a controlled manner to yield predominantly singly charged ions through reactions with bipolar (i.e., both positively and negatively charged) ions generated using a 210Po alpha particle source. The electrospray-generated multiply charged ions undergo charge reduction in a "neutralization chamber" positioned before the entrance nozzle to the mass spectrometer. The ions are detected using a commercial orthogonal electrospray time-of-flight mass spectrometer, although the neutralization chamber can be adapted to virtually any mass analyzer. The CREMS results obtained exhibit a signal intensity drop-off with increasing oligonucleotide size similar to that observed with matrix-assisted laser desorption/ionization mass spectrometry. Proton-transfer reactions were found to be responsible for reducing charge on proteins and oligonucleotides in both positive and negative ion mode.  相似文献   

7.
Yao ZP  Wan TS  Kwong KP  Che CT 《Analytical chemistry》2000,72(21):5394-5401
The determination of enantiomeric excess (ee) of amino acids was achieved by investigating the collision-induced dissociation spectra of protonated trimers that were formed by electrospray ionization of amino acids in the presence of one of the following chiral selectors: L- or D-N-tert-butoxycarbonylphenylalanine, L- or D-N-tert-butoxycarbonylproline, and L- or D-N-tert-butoxycarbonyl-O-benzylserine. The protonated trimers were dissociated to form protonated dimers, and the observed dissociation efficiency r (i.e., the intensity ratio of protonated dimers to protonated trimers) for an enantiomeric mixture was found to be related to its ee value by the following equation: r = a + b/(c + ee), where a, b, and c were constants. A linear calibration plot was obtained by plotting r versus 1/(c + ee), where c was calculated with the MATLAB software, or by plotting 1/(r - r0) versus 1/ee, where r0 was the r value for the racemic mixture. The latter "two-reciprocal" method was more convenient for application. Another practical method for ee determination was the "three-point" method, whereby the ee of an unknown sample with a measured r value could be derived from the equation ee = 100?1/(rL - r0) - 1/(rD - r0)?/?2/(r - r0) - 1/(rL - r0) - 1/(rD - r0)?, with rL and rD being the r values for the enantiomerically pure L- and D-forms of the sample, respectively. A calibration plot was not required. The ee determination was achieved with acceptable precision even for the worst case of acceptable chiral recognition with a particular chiral selector, suggesting that the ee determination of all 19 common amino acids could be achieved by the present method. The ee of a histidine sample was determined both by the two-reciprocal method, giving an error of 0.2% ee (1.1% relative error) and consuming only approximately 5.3 nmol of sample, and by the three-point method, giving an error of 0.4% ee and consuming only approximately 2.3 nmol of sample. In the latter case, it took 27 min for the mass spectrometric measurements of the three calibration standards and an additional 9 min for the unknown sample. The direct ee determination of more than one amino acid in a mixture was also demonstrated in the study.  相似文献   

8.
The ambient mass spectrometry technique, desorption electrospray ionization mass spectrometry (DESI-MS), is applied for the rapid identification and spatially resolved relative quantification of chlorophyll degradation products in complex senescent plant tissue matrixes. Polyfunctionalized nonfluorescent chlorophyll catabolites (NCCs), the "final" products of the chlorophyll degradation pathway, are detected directly from leaf tissues within seconds and structurally characterized by tandem mass spectrometry (MS/MS) and reactive-DESI experiments performed in situ. The sensitivity of DESI-MS analysis of these compounds from degreening leaves is enhanced by the introduction of an imprinting technique. Porous polytetrafluoroethylene (PTFE) is used as a substrate for imprinting the leaves, resulting in increased signal intensities compared with those obtained from direct leaf tissue analysis. This imprinting technique is used further to perform two-dimensional (2D) imaging mass spectrometry by DESI, producing well-resolved images of the spatial distribution of NCCs in senescent leaf tissues.  相似文献   

9.
We report the use of desorption electrospray ionization hybrid Fourier transform ion cyclotron resonance mass spectrometry (DESI-FT-ICR-MS) for the analysis of carbohydrates. Spectra of neat carbohydrates are presented along with their mass measurement accuracies and limits of detection. Furthermore, a comparison is made between the analyses of O-linked glycans from mucin by DESI-FT-ICR-MS and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry. Finally, glycans from mucin are identified by using the high mass measurement accuracy and tandem MS capabilities afforded by the hybrid FT-ICR-MS platform.  相似文献   

10.
Yao ZP  Wan TS  Kwong KP  Che CT 《Analytical chemistry》2000,72(21):5383-5393
Chiral recognition of 19 common amino acids was achieved by investigating the collision-induced dissociation spectra of protonated trimers that were formed from the electrospray ionization of amino acids in the presence of one of the following chiral selectors: L- or D-N-tert-butoxycarbonylphenylalanine, L- or D-N-tert-butoxycarbonylproline, and L- or D-N-tert-butoxycarbonyl-O-benzylserine. The protonated trimers were dissociated to protonated dimers, and the intensity ratios of the protonated dimer (product ion) to the protonated trimer (precursor ion), i.e., the observed dissociation efficiency, was found to be strongly dependent on the chirality of the amino acids with respect to that of the chiral selectors. The results showed that the chirality of all 19 common amino acids can be definitely differentiated. The method was demonstrated as rapid, sensitive, precise, robust, and requiring no reference standards and only minimal sample preparation. The chirality of all three amino acids in a mixture was determined without prior separation of the amino acids, consuming only 70 pmol of sample and requiring only approximately 14 min of mass spectrometric measurements. A cyclodipeptide with unknown chirality was determined to be cyclo-(L-Pro-L-Leu) by acid hydrolysis followed by the present method, and the results were consistent with the physiochemical properties and NMR data of the compound. This study suggested that ESI-MS/MS can be a promising approach for the chiral recognition of other compounds.  相似文献   

11.
A major limitation of mass spectrometry-based proteomics is inefficient and differential ionization during electrospray ionization (ESI). This leads to problems such as increased limits of detection and incomplete sequence coverage of proteins. Incomplete sequence coverage is especially problematic for analyses that require the detection and identification of specific peptides from a protein, such as the analysis of post-translational modifications. We describe here the development and use of aldehyde-based chemistry for the alkylation of peptide primary amines to increase peptide hydrophobicity, providing increased ionization efficiency and concomitant signal enhancement. When employed to modify the peptide products of protein tryptic digests, increased sequence coverage is obtained from combined modified and unmodified digests. To evaluate the utility of alkylation of peptides for selected reaction monitoring (SRM) assays, we alkylated a peptide from the protein Oct4, known to play a role in regulating stem cell differentiation. Increased chromatographic retention and ionization efficiency is observed for the alkylated Oct4 peptide compared to its unmodified form.  相似文献   

12.
Nearly a decade after first commercialization, high field asymmetric waveform ion mobility spectrometry (FAIMS) has yet to find its place in routine chemical analysis. Prototypes have been used to demonstrate the utility of this separation technique combined with mass spectrometry (MS). Unfortunately, first generation commercial FAIMS instruments have gone practically unused by early adopters. Here, we show this to be due to poor ion transmission in the FAIMS-MS source interface. We present simple instrumental modifications and optimization of experimental conditions to achieve good performance from the first generation commercial FAIMS device (the Ionalytics Selectra) coupled to a high resolution Q-TOF-MS. In combination with nanospray ionization, we demonstrate for the first time the nontarget analysis of urine by FAIMS with minimal sample preparation. We show the unique suitability of electrospray ionization (ESI)-FAIMS-MS for identification of low abundance species such as urinary biomarkers of damage of nucleic acids in a complex biological matrix. The elimination of electrospray noise and matrix components by FAIMS and the continuous flow of analytes through FAIMS for accurate and tandem mass analysis produce high quality spectral data suitable for structural identification of unknowns. These characteristics make ESI-FAIMS-MS ideal for nontarget identification, even when compared to high efficiency LC-ESI-MS.  相似文献   

13.
The distribution of metal species in solution was determined using flow injection electrospray ionization mass spectrometry. Complexes formed by selected metal ions with added organic ligands in 50:50 water/acetonitrile and 50:50 water/methanol under acidic, neutral, and basic conditions were detected using electrospray ionization conditions optimized to best represent solution-phase interactions. Metal species containing acetate, nitrate, and solvent molecules predominated in acidic solution but became less abundant at higher pH. Interactions between metal ions and added organic ligands became more selective with increasing pH, showing the expected preference of hard and soft ligands for metal ions of the corresponding type. Species distributions also tended toward larger complexes as pH increased. Overall ion yield was greater for aqueous acetonitrile than for aqueous methanol solutions; however, reduction of copper(II) in aqueous acetonitrile resulted in the detection of copper(I) complexes for certain ligands. Experimental results for copper(II) and 8-hydroxyquinoline in 50:50 water/methanol showed good agreement with aqueous speciation predicted using the thermodynamic equilibrium model MINEQL. Detection of neutral complexes was achieved by protonation, deprotonation, or electrochemical oxidation during electrospray.  相似文献   

14.
Selectivity, binding stoichiometry, and mode of binding of Tel01, distamycin A, and diethylthiocarbocyanine iodide (DTC) to the parallel stranded G4-quadruplex [d(T2G5T)]4 were investigated by ESI-MS. The first drug/quadruplex complexes observed by ESI-MS are described. Tel01, distamycin A, and DTC all form complexes with quadruplex DNA, but only Tel01 is completely selective for quadruplex versus duplex oligonucleotide under the conditions employed. Previous solution determinations of the binding mode of Tel01 and distamycin A to quadruplex oligonucleotides indicate that Tel01 interacts through end-stacking with guanine tetrads of quadruplex DNA, while distamycin A interacts by binding to quadruplex grooves. When these two different drug/quadruplex complexes are subjected to collisionally activated dissociation in a mass spectrometer, the observed fragmentation patterns are distinct. Tel01/quadruplex complexes undergo facile loss of drug and dissociation to single-strand oligonucleotide ions, while distamycin/quadruplex complexes fragment into single-strand oligonucleotide ions in which the drug molecule is retained. Dissociation patterns for DTC/quadruplex complexes are similar to those of distamycin; therefore, it is concluded that DTC interacts with [d(T2G5T)]4 through groove-binding. These ESI-MS results are applicable to both the identification and characterization of G-quadruplex interactive agents and may also be useful in probing unusual DNA structures.  相似文献   

15.
Matz LM  Hill HH 《Analytical chemistry》2001,73(8):1664-1669
The separation of opiates and the primary metabolites was evaluated with ESI-IMS/MS. Seven opiate molecules were analyzed, and spectra were shown for each compound. The IMS separation of two isomers (morphine and norcodeine) was shown with baseline separation. Differences in the mobilities were found for the nonacetylated, monoacetylated, and biacetylated compounds. In this study, two primary findings are reported. First, IMS can easily separate metabolic isomers, and second, the two-dimensional separation capability of IMS/MS can be employed to confidently identify and separate both the opiates and metabolites. Although previous IMS studies have shown the separation of isomers, this is the first example to show the capability of IMS to separate metabolic isomers (within 70 s), a significant advantage in high-throughput screening for pharmacokinetic studies. Second, the monoacetylated and biacetylated compounds were found to form more compact ions for the sodium adducts in comparison to the protonated molecular ions. On the basis of the mobilities, information on structures and conformation can be deduced when sodium and protonated ions are compared.  相似文献   

16.
Ma X  Zhao M  Lin Z  Zhang S  Yang C  Zhang X 《Analytical chemistry》2008,80(15):6131-6136
A simple and easy-to-build high-throughput analysis system was constructed. The system consisted of three major components: (1) a multichannel device with 16 parallel capillaries, (2) a desorption electrospray ionization (DESI) source, and (3) a linear ion trap mass spectrometer. When analyses were performed, the multichannel device was moved horizontally on a translation stage controlled by a step motor. Our design expands the functions of DESI, in which the liquid sample in capillary was driven out by the nebulizing gas, ionized, and then transferred to a mass spectrometer. To assess the high-throughput performance of the system, 5 mg/L 1,3-diethyl-1,3-diphenylurea (DDU) solution and 10 mg/L angiotensin I solution were alternatively loaded into the reservoirs and capillaries in the multichannel device. Results indicated that analyses of the all the samples in 16 capillaries were completed within 1.6 min, which means a throughput of 600 samples/h. Reactive DESI experiment was also successfully performed with this system to show the feasibility of online derivatization. The relative standard deviations for a single capillary and five identical capillaries were 7.6 (n = 16) and 12.3%, respectively. Linear relative abundance response was achieved for DDU (r = 0.9971).  相似文献   

17.
Chemical structures of polymer end groups play an important role in determining the functional properties of a polymeric system. We present a mass spectrometric method for determining end group structures. Polymeric ions are produced by electrospray ionization (ESI), and they are subject to source fragmentation in the ESI interface region to produce low-mass fragment ions. A series of source-fragment ions containing various numbers of monomer units are selected for high-energy collision-induced dissociation (CID) in a sector/time-of-flight tandem mass spectrometer. It is shown that high-energy CID spectra of source-induced fragment ions are very informative for end group structure characterization. By comparing the CID spectra of fragment ions with those of known chemicals, it is possible to unambiguously identify the end group structures. The utility of this technique is illustrated for the analysis of two poly(ethylene glycol)-based slow-releasing drugs where detailed structural characterization is of significance for drug formulation, quality control, and regulatory approval. Practical issues related to the application of this method are discussed.  相似文献   

18.
We describe a method, based on pressure-assisted capillary electrophoresis coupled to electrospray ionization mass spectrometry (PACE/ESI-MS), that allows the simultaneous and quantitative analysis of multivalent anions, such as citrate isomers, nucleotides, nicotinamide-adenine dinucleotides, and flavin adenine dinucleotide, and coenzyme A (CoA) compounds. Key to the analysis was using a noncharged polymer, poly(dimethylsiloxane), coated to the inner surface of the capillary to prevent anionic species from adsorbing onto the capillary wall. It was also necessary to drive a constant liquid flow toward the MS by applying air pressure to the inlet capillary during electrophoresis to maintain a conductive liquid junction between the capillary and the electrospray needle. Although theoretical plates were inferior to those obtained by CE/ESI-MS using a cationic polymer-coated capillary, the PACE/ESI-MS method improved reproducibility and sensitivity of these anions. Eighteen anions were separated by PACE and selectively detected by a quadrupole mass spectrometer with a sheath-flow electrospray ionization interface. The relative standard deviations (n = 6) of the method were better than 0.6% for migration times and between 1.4% and 6.2% for peak areas. The detection limits for these species were between 0.4 and 3.7 micromol/L with pressure injection of 50 mbar for 30 s (30 nL), that is, mass detection limits calculated in the range from 12 to 110 fmol at a signal-to-noise ratio of 3. The utility of the method was demonstrated by analysis of citrate isomers, nucleotides, dinucleotides, and CoA compounds extracted from Bacillus subtilis cells.  相似文献   

19.
Electrospray and tandem mass spectrometry are used to characterize underivatized oligosaccharides that have been digested from asparagine side chains of glycoproteins. Oligosaccharides that contain sialic acids were detected with the best sensitivity in the negative-ion detection mode whereas those that do not contain sialic acid were detected with the best sensitivity in the positive-ion detection mode. The positive-ion abundances of oligosaccharides were greatly enhanced in electrospray mass spectra by adding 10 mM sodium acetate or ammonium acetate to the sample solvent. Tandem mass spectrometry was used to determine primary structural features of the oligosaccharides. Methodology that has been developed on branched high-mannose, hybrid, and complex carbohydrate standards was applied to a mixture of oligosaccharides that were digested with N-glycanase from the glycoprotein, ovalbumin. The composition and relative abundances of individual oligosaccharides obtained from the electrospray mass spectrum compare favorably to those obtained by anion-exchange chromatography/pulsed amperometric detection and by gel permeation chromatography of the oligosaccharides after radiolabelling the reducing end of the carbohydrates. The oligosaccharide content of ovalbumin was independently determined from the heterogeneity observed in the electrospray mass spectrum of the intact 44-kDa glycoprotein. Comparison of the oligosaccharide compositions determined before and after enzymatic digestion shows a selective digestion of high-mannose and low molecular weight oligosaccharides by N-glycanase.  相似文献   

20.
Huang L  Riggin RM 《Analytical chemistry》2000,72(15):3539-3546
An HPLC/MS method has been developed that allows rapid, direct analysis of underivatized sialylated as well as neutral oligosaccharides. The method involves the separation of oligosaccharides from salts and proteins using RP-HPLC with a formic acid/acetonitrile/water mobile phase system and on-line electrospray mass spectrometry analysis in the positive ion mode. Under the solution conditions employed, both neutral and acidic (sialylated) oligosaccharides are protonated and therefore detected. In contrast to MALDI-TOF MS, no loss of sialic acid is observed when operating in the positive ion mode. Furthermore, the capability of this method to provide quantitative estimates of the relative abundance of each oligosaccharide mass has been demonstrated using fetuin as a model compound.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号