首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到14条相似文献,搜索用时 7 毫秒
1.
Abstract— A thick‐film ceramic‐sheet PDP provides a long sustain discharge gap of 0.45 mm, enabling the use of positive column discharges. The discharges are established in the middle of the discharge space and are completely free from touching the surface of substrates. This allows for the reduction in diffusion losses of the charged particles. To further improve the efficacy, delayed D pulses are applied to the address electrodes during the sustain period. Although the pulses only draw a little current, they perturb the electric field, reducing the peak discharge current and hence resulting in higher efficacy and luminance. The efficacy and luminance increase by 35% and 38%, respectively, with the delayed D pulses. These pulses are incorporated into the contiguous‐subfield erase‐addressing drive scheme for TV application. A short gap of 70 μm between the sustain and data electrodes generates a fast‐rising discharge and allows a high‐speed addressing of 0.25 μsec. This provides 18 contiguous subfields for the full‐HD single‐scan mode, with 70% light emission duty. A luminous efficacy of 6.0 lm/W can been attained using Ne + 30% Xe 47 kPa, a sustain voltage of 320 V, and a sustain frequency of 3.3 kHz, when the luminance is 157 cd/m2. Alternatively, the panel can achieve 4.2 lm/W and 1260 cd/m2 by increasing the sustain frequency to 33 kHz.  相似文献   

2.
The performance of two 4‐in. color PDP test panels with a default and a high‐Xe‐concentration gas mixture will be discussed. The default panel with a gas mixture of 3.5% Xe in Ne and a filling pressure of 665 hPa was compared with a panel containing a gas mixture of 13.5% Xe in Ne and a filling pressure of 800 hPa. The panels contain a green phosphor, YBO3:Tb, which showed less saturation at high UV load compared with a Willemite phosphor. The panel performance was compared in addressed conditions. For the default panel, a white luminance of 710 cd/m2 and an efficacy of 1.6 lm/W was found, while for the high‐Xe‐partial‐pressure panel, a white luminance of 2010 cd/m2 and an efficacy of 3.8 lm/W was realized. The increase of the driving voltages, about 20–30 V, is moderate. Finally, color saturation is improved at high Xe partial pressure.  相似文献   

3.
Abstract— The plasma‐tube‐array display is expected to become a wall‐sized display with very high luminous efficacy. The cell design for high luminous efficacy was investigated. Also, discharging in the plasma tube was observed in order to investigate the structure for high luminous efficacy. As the result, a high luminous efficacy of 5.4 lm/W was achieved.  相似文献   

4.
Abstract— The trade‐off between PDP efficacy improvement and driving voltages was investigated for several design factors. It was found that for a proper combination of an increased Xe content, cell design, and the use of a TiO2 layer combined with “non‐saturating” phosphors, a large increase in both efficacy and luminance can be realized at moderately increased drive voltages. In a 4‐in. color test panel, a white efficacy of 5 lm/W and a luminance of 5000 cd/m2 was obtained for sustaining at 260 V in addressed condition.  相似文献   

5.
To improve PDP performance, we developed an AC‐PDP with the Delta Tri‐Color Arrangement (DelTA) cell structure and arc‐shaped electrodes. The experimental panel has a pixel pitch of 1.08 mm and luminous efficacy of 3 lm/W at a luminance of 200 cd/m2 despite its conventional gas mixture of Ne and Xe (4%) and conventional phosphor set. Moreover, its peak luminance can be greater than 1000 cd/m2. The strong dependence of luminous efficacy on the sustain voltage is also discussed in this paper.  相似文献   

6.
Abstract— The discharge mechanism concerning the width of the display electrodes in high‐Xe‐content gas mixtures to improve the luminous efficacy of PDPs has been researched. It was found that a luminous efficacy of 5 lm/W was realized for a high‐Xe‐content gas mixture and narrower display electrodes. For a high‐Xe‐content gas mixture, the luminous efficacy increases as the display electrode becomes narrower. This phenomenon was analyzed by observing the emission from a discharge cell. The observation data indicate that a high electron heating efficiency contributes to increased luminous efficacy along with narrow electrodes for a high‐Xe‐content gas mixture as well as high excitation efficiency.  相似文献   

7.
Abstract— In this paper we explain how macro‐cells (real PDP cells scaled‐up a hundred times) with external and removable electrodes have been validated by comparison with real panels and modeling and used to optimize the luminous efficacy of real PDPs. We illustrate the application of the macroscopic PDP tool to optimize the electrode configuration of short‐gap discharges towards higher luminous efficacy, as well as its use in conjunction with 2D and 3D modeling to lower the operating voltages of high‐efficacy long‐gap discharges triggered by auxiliary electrodes.  相似文献   

8.
Abstract— In order to realize high‐luminance and luminous‐efficacy mercury‐free flat fluorescent lamps (MFFLs) for LCD backlighting, the phosphor profile was optimized to enlarge the surface area. The proposed uneven profile of the rear phosphor increases the effective surface area of the phosphor, resulting in a wide luminance range from 3000 to 16,788 cd/m2 with a corresponding high luminous efficacy from 66 to 34.7 lm/W, respectively. Also, a dynamic operation method for an adaptive local‐dimming and scanning operation is proposed which can be used in a 32‐in. multi‐structured configuration having one inverter system. With the deployment of the bipolar drive scheme and dual auxiliary electrodes, a stable and selective diffuse glow discharge with high luminance is possible.  相似文献   

9.
Abstract— It has been well known that the luminous efficiency of PDPs can be improved by increasing the Xe content in the panel. For instance, the efficiency is improved by a factor 1.7 when the Xe content is increased from 3.5% to 30%. The sustain pulse voltage, however, increases from 180 to 230 V by a factor 1.3. It was found that the increase in the sustain pulse voltage can be suppressed by increasing the sustain pulse frequency. The high‐frequency operation further increases the luminous efficiency. If the Xe content is increased from 3.5% to 30% and the drive pulse frequency is increased from 147 to 313 kHz, the luminous efficiency becomes 2.7 times higher and the luminance 4.5 times higher. Furthermore, the increase in the sustain pulse voltage is suppressed 1.1 times, from 180 to 200 V. A mechanism of attaining high efficiency and low‐voltage performance can be considered as follows. A train of pulses is applied during a sustain period. As the sustain pulse frequency is increased, the pulse repetition rate becomes faster and a percentage of the space charge created by the previous pulse remains until the following pulse is applied. Due to the priming effect of these space charge, the discharge current build‐up becomes faster, the width of the discharge current becomes narrower, ion‐heating loss is reduced, and the effective electron temperature is optimized so that Xe atoms are excited more efficiently. The intensity of Xe 147‐nm radiation, dominant in low‐pressure Xe dis‐charges, saturates with respect to electron density due to plasma saturation. This determines the high end of the sustain pulse frequency.  相似文献   

10.
Abstract— Power savings, image‐quality improvement, and cost reduction are the major issues facing PDP development. High‐Xe‐content PDPs have attained improved luminous efficiency, but with sacrifices in higher switching and sustain voltages and slower discharge build‐up. By examining PDPs having 3.5%–30% Xe content, it was found that utilization of the space‐charge priming effect as well as wall‐charge accumulation are effective in obtaining a low operating voltage and a high switching speed. The improvements are enhanced for higher Xe pressures. By using space‐charge priming, the statistical time lag of the discharge triggering for the 30% Xe content is reduced significantly and becomes approximately equal to that of 3.5% Xe content. Once triggered, the formative time lag of the discharge becomes shorter and the space charge experiences diffusion/drift; hence, accumulation of the wall charge is faster for discharges with higher Xe contents. These indicate that the use of an erase addressing scheme, rather than a write addressing scheme, is preferable when driving high Xe‐content PDPs, because the erase addressing scheme provides the addressing operation with an abundant amount of priming particles. Also, the drive voltages are lower for the erase addressing scheme. In order to reduce the address voltage, it is effective to accumulate wall charges prior to addressing. It was found that there are limiting values for the charge accumulation, above which self‐erase discharges ignite and the wall charge is dissipated. The self‐erase discharge occurs at relatively low wall voltages when the Xe percentages becomes higher. The sustain pulse voltage can be reduced while keeping the luminous efficiency high by increasing the sustain pulse frequency. As the frequency is increased, a residual amount of space charge created by the preceding sustain pulse increases. Due to the priming effect of these space charge, the build‐up of the discharge current becomes faster, resulting in a lower voltage.  相似文献   

11.
A capacity‐coupled electrodeless Hg discharge lamp has been developed for LC TV backlightings. By applying sinusoidal voltages which are 180° out of phase with a pair of external electrodes, a luminous uniformity of over 84% is attained in two types of lamps whose lengths are 190 and 390 mm. Luminance, efficacy, and input power to the lamp are 114,000 cd/m2, 35 lm/W, and 21.5 W when the 390‐mm lamp is driven at 5 MHz. With a frequency below 1.1 MHz, eight 390‐mm lamps, connected in parallel to one another without external ballast impedance, can be driven by using a single inverter.  相似文献   

12.
Abstract— A technique called “self‐erase‐discharge addressing” has been incorporated with a address‐while‐display driving scheme, contiguous subfield, and erase addressing to obtain high‐speed and low‐voltage addressing of PDPs. The technique uses a relatively high X‐sustain pulse voltage VXsus, which produces a weak self‐erase discharge at its trailing edge. An application of a data pulse Vdata synchronous to a weak self‐erase discharge results in full erase discharge and eliminates all the wall charges. The technique assures a wider operating‐voltage margin since it provides identical amounts of priming charges as well as wall charges to all the horizontal scan lines just prior to addressing. The priming charges are generated by the weak self‐erase discharges, resulting in low Vdata of 30 V and a high addressing speed of 0.66 μsec for a Ne + 10% Xe PDP. VXsus = 245 V, and the voltage margins of Vdata and VXsus were 35 and 16 V, respectively. For a 30% Xe PDP, Vdata and VXsus were 30 and 335 V, respectively, with an addressing speed of 1.0 μsec. In order to obtain high dark‐room contrast, it is essential to use ramp reset pulses, with which erase addressing cannot be achieved. By adopting the write addressing only to the first subfield and the self‐erase‐discharge addressing to the subsequent subfields, a peak and background luminance in green of 3100 and 0.22 cd/m2, respectively, were obtained with a dark‐room contrast of 14,000:1. The number of subfields was 28, and the light emission duty was 83%. The number of ramp reset pulse drivers could be reduced to 12 by adopting the common reset pulse technique.  相似文献   

13.
Abstract— Among various barrier‐rib manufacturing processes, the mold‐pattern‐transfer method has potential to reduce processing cost as well as the manufacture of high‐resolution pixels. In this study, the effects of major processing variables of the mold‐pattern‐transfer process on the formation of air‐trapped pores within barrier ribs were examined. The results indicated that with an optimum combination of the processing variables, barrier ribs without trapped defects can be produced, demonstrating the possibility of reducing the number of processing steps and costs of barrier ribs.  相似文献   

14.
Abstract— 8‐in. AC plasma display panels with front address (FA) structures were developed. Deep barrier ribs, high‐Xe‐content gas, and long sustain gaps were applied to FA structures to achieve high luminous efficacy. The FA structures have several advantages over conventional structures. Because address electrodes are closer to sustain electrodes, FA PDPs can be driven at lower address voltages, under the condition of deep barrier ribs or high‐Xe‐content gas, than conventional PDPs. A disadvantage of FA PDPs is relatively high capacitance between the sustain electrodes and address electrodes compared to that of conventional PDPs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号