首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Heat exchangers are extensively used in various industries. In this study, the impact of geometric and flow parameters on the performance of a shell and double helical coil heat exchanger is studied numerically. The investigated geometric parameters include external coil pitch, internal coil pitch, internal coil diameter, and coil diameter. The influences of considered geometrical parameters are analyzed on the output temperature of the hot and cold fluid, convective heat transfer coefficient, pressure drop, and average Nusselt number. Water is considered as working fluid in both shell and tube. As an innovation, double helical coils are used instead of one in the heat exchanger. To compare the obtained results accurately, in each section, the heat transfer area (coil outer surface) is kept constant in all models. The results show that the geometrical parameters of double helical coils significantly affect the heat transfer rate.  相似文献   

2.
Thermalhydraulic performances of membrane helical-coil heat exchangers in in-line and staggered arrangements, are numerically investigated. The influences of Reynolds number, dimensionless pitch, and arrangement on heat transfer and flow are discussed. Moreover, the axial and tangential velocity distributions were presented for various pitches and arrangements. The results show that the membrane helical-coil arrangement has a profound effect on the thermalhydraulic performance. For the smaller radial pitch (s 1/d < 1.8), the heat transfer coefficient in in-line arrangement is higher than that in staggered arrangement. Meanwhile, the in-line arrangement gives a significantly higher friction factor than the staggered arrangement. However, for the larger radial pitch (s 1/d ≥ 1.8), the coil arrangement appears to have no effect on the heat transfer and friction factor. In addition, the average Nusselt number Nu and the friction factor f for in-line and staggered arrangements were calculated and correlated against the Reynolds number and structural parameters. According to the thermalhydraulic performance evaluation criterion, the staggered arrangement is recommended as the optimal coil arrangement.  相似文献   

3.
In this article, the heat transfer performance of a syngas cooler with membrane helical-coil heat exchanger was numerically studied. A method of combining piecewise simulation and full-scale simulation was proposed, and the influence of fly ash was considered. The models and the proposed method were validated by comparing simulation results with data from industrial test. The simulation results show that radiation accounts for 10–20% of the total heat transfer in the syngas cooler. The surface of inner channel is characterized with high convective heat-transfer coefficient and heat flux. In addition, the quality of produced steam could be significantly enhanced as the heat exchanger of upper group was changed from evaporating surface to superheating surface, and the cooling performance for syngas was hardly affected.  相似文献   

4.
对倾斜角20°有34根管子的周向重叠三分螺旋折流板换热器进行了数值模拟研究,通过在三分螺旋折流板换热器壳侧通道内偏心纵向切面和横切面以及六边形纵向切面上速度矢量流场和压力云图的叠加展示,不仅呈现了壳侧总体螺旋速度的周向分量的轨迹,而且从所呈现的轴向和径向速度分量揭示了二次流和相邻折流板V型缺口处逆向泄漏的踪迹.研究结果表明:流体在螺旋通道内在离心力作用下呈现向外扩张的流动趋势,然后在外围高、中心低的压力分布作用下沿着靠近折流板附近的流速较低的区域向心流动返回轴中心,形成单涡型迪恩二次流;二次流增强了流体的掺混,从而有利于强化传热.  相似文献   

5.
Exergy—Economic Criteria for Evaluating Heat Exchanger Performance   总被引:4,自引:0,他引:4  
honductiOnHeat exchangee as one of the thennal equlpment,is widely used in energy systems, the imPrvement ofheat exchangers perfonnance is imPOrtan for savingenergy and twving tbe efficiency, so it is necessaryto emPloy a general driterion to evaluate heatexchanger perfrmance. In the design of heatexchangers, numrous perfrmance evaluation criteriaealst tO heIP to detennine their fhatUfs11]. Thesecriteria lead towards the goal of oPtindzationprocedurs. They dePend on the asPeCt of o~zation…  相似文献   

6.
氟塑料换热器以其耐腐蚀、耐磨损等优点而备受关注,但氟塑料热导率较低,换热能力差,限制了其广泛应用。石墨烯-PFA复合材料兼具石墨烯优异的导热性和可熔性聚四氟乙烯(PFA)良好的耐酸碱腐蚀性,是新一代的换热器材料。搭建了余热回收测试实验台,对石墨烯-PFA复合材料换热器和金属换热器的传热性能进行对比。研究了不同烟气流速、不同进口烟气温度以及不同石墨烯配比对复合材料传热性能的影响。结果表明:对于金属换热器和复合材料换热器,当烟气流速从2.0增加到4.0 m/s时,传热系数分别增加到原来的1.19和1.34倍;随着进口烟温的升高,两种材质的传热系数分别降低了15.6%和14.7%;随着石墨烯含量增加,复合材料的导热系数以及传热系数均增加。  相似文献   

7.
ABSTRACT

Conjugate heat transfer to supercritical CO2 in membrane helical coiled tube heat exchangers has been numerically investigated in the present study. The purpose is to provide detailed information on the conjugate heat transfer behavior for a better understanding of the abnormal heat transfer mechanism of supercritical fluid. It could be concluded that the supercritical fluid mass flux and vertical/horizontal placement would significantly affect the abnormal heat transfer phenomenon in the tube side. The flow field of supercritical fluid is affected by both the buoyancy and centrifugal force in the conjugate heat transfer process. The local wall temperature and heat transfer coefficient in the tube side would rise and fall periodically for the horizontal heat exchanger, but this phenomenon will gradually disappear with the increase of the mass flow rate or fluid temperature in the tube side. The dual effects of buoyancy force and centrifugal force lead to the deflection of the second flow direction for the vertical placement, which further results in the heat transfer deterioration region on the top-generatrix wall for the downward flow being larger than that for the upward flow.  相似文献   

8.
In the present study an experimental investigation of the mixed convection heat transfer in a coil-in-shell heat exchanger is reported for various Reynolds and Rayleigh numbers, various tube-to-coil diameter ratios and dimensionless coil pitch. The purpose of this article is to assess the influence of the tube diameter, coil pitch, shell-side and tube-side mass flow rate over the performance coefficient and modified effectiveness of vertical helical coiled tube heat exchangers. The calculations have been performed for the steady-state and the experiments were conducted for both laminar and turbulent flow inside coil. It was found that the mass flow rate of tube-side to shell-side ratio was effective on the axial temperature profiles of heat exchanger. The results also indicate that the ? − NTU relation of the mixed convection heat exchangers was the same as that of a pure counter-flow heat exchanger.  相似文献   

9.
In this study, the heat transfer performance and friction characteristics of a novel concentric tube heat exchanger with different pitches of helical turbulators were investigated experimentally and numerically for a Reynolds number range from 3000 to 14 000. An experimental system was established to obtain experimental data. The numerical simulations were performed by using a three dimensional numerical computation technique, a commercial CFD computer code. Then, the heat transfer performance and friction characteristics of several helical turbulators were compared. The experimental, numerical and empirical correlation results were in a good agreement with each others. As a result, the heat transfer enhancements using turbulators were 2.91, 2.41, 2.18 and 1.99 times better than the smooth tube for pitch distances of p = 20, 40, 60 and 80 mm, respectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
Extended surfaces mostly aim to improve the heat transfer upon increasing the area of heat transfer. In this paper, the influence of using fins on flow behaviors and the heat transfer of the shell and tube heat exchanger has been investigated. In this regard, the present results are verified with available experimental data in the literature for a helical tube without fins. The effects of fin density (fin per inch), its height, and material have been studied on the heat transfer rate. In addition, the effects of radial pitch and the number of coil loops are studied. The results indicate that implementing extended surfaces significantly increases the heat transfer rate. The increase of fin density from 8 to 12 and the height from 11.5 to 13.5 mm enhances heat transfer up to 48% and 43% depending on Dean number, respectively. The rise of coil pitch augments the overall heat transfer, and it is more efficient at lower Dean numbers. The predicted results also show that the fin material does not have any significant effect on heat transfer.  相似文献   

11.
为了获得开缝布置方式对开缝翅片管换热器传热与阻力特性的影响规律,对5种不同翅片管换热器进行了数值模拟研究,并进行了模化试验验证。结果表明:增加开缝会提高翅片管换热器的传热性能,但阻力也随之增加;与开缝位置相比,开缝数量对开缝翅片管换热器传热与阻力特性的影响更大;在Re=4800~7500日时,开缝翅片管换热器综合流动传热性能 随着Re数的增大而增大;在5种翅片中,开缝翅片的综合流动传热性能高于普通平直翅片;数值模拟与试验结果偏差较小,采用数值模拟方法能够比较准确地分析开缝翅片管换热器的传热与阻力特性。  相似文献   

12.
板式换热器在工业生产中广泛应用,采用数值模拟和实验相结合的方法对新型蜂窝板式换热器进行研究。结果表明:数值模拟和实验结果在合理的误差范围内,验证了数值模拟的可靠性。新型板式换热器内部蜂窝结构附近的速度场出现规律的周期性变化,流体湍流强度增加,Nu和阻力系数f随焊孔直径和蜂窝直径的增加而增大,通过对蜂窝板在3 000≤Re≤25 000的数据结果进行关联,得到了蜂窝板流动换热的准则关系式,为蜂窝板式换热器的优化提供了理论依据,并为工业生产提供参考。  相似文献   

13.
Steady heat transfer enhancement has been studied in helically coiled-tube heat exchangers. The outer side of the wall of the heat exchanger contains a helical corrugation which makes a helical rib on the inner side of the tube wall to induce additional swirling motion of fluid particles. Numerical calculations have been carried out to examine different geometrical parameters and the impact of flow and thermal boundary conditions for the heat transfer rate in laminar and transitional flow regimes. Calculated results have been compared to existing empirical formulas and experimental tests to investigate the validity of the numerical results in case of common helical tube heat exchanger and additionally results of the numerical computation of corrugated straight tubes for laminar and transition flow have been validated with experimental tests available in the literature. Comparison of the flow and temperature fields in case of common helical tube and the coil with spirally corrugated wall configuration are discussed. Heat exchanger coils with helically corrugated wall configuration show 80–100% increase for the inner side heat transfer rate due to the additionally developed swirling motion while the relative pressure drop is 10–600% larger compared to the common helically coiled heat exchangers. New empirical correlation has been proposed for the fully developed inner side heat transfer prediction in case of helically corrugated wall configuration.  相似文献   

14.
Metal-hydride (MH) reactors are one of the most promising approaches for hydrogen storage because of their low operating pressure, high storage volumetric density and high security. However, the heat transfer performance of the MH reactor for high hydrogenation rate is inferior. In this study, the heat transfer and hydrogen absorption process of metal hydride tank performance in Mg2Ni bed is analyzed numerically using commercial ANSYS-FLUENT software. The MH reactor is considered a cylindrical bed including a helical tube along with a central straight return tube for the cooling fluid. The effects of geometrical parameters including the tube diameter, the pitch size and the coil diameter as well as operational parameters on the heat exchanged and hydrogen absorption reactive time are evaluated comprehensively. The results showed that the helical heat exchanger along with central return tube could effectively improve heat exchanged between the cooling fluid and the metal alloy and reduce the temperature of the bed results in a higher rate of hydrogen absorption. For a proper configuration and geometry of the helical coil heat exchanger with a central return tube, the absorption reaction time is reduced by 24% to reach 90% of the storage capacity. After the optimization study of the geometrical parameters, a system with the heat exchanger tube diameter of 5 mm, coil diameter of 18 mm and the coil pitch value of 10 mm is recommended to have lower hydrogen absorption time and higher hydrogen storage capacity. The presented MH reactor can be applied for improvement of heat exchange and absorption process in industrial MH reactors.  相似文献   

15.
On the basis of experimental verification of mathematical model, the influence of honeycomb ceramic on heat extraction is numerically studied under the steady state condition. The calculation results show the packed honeycomb ceramic influences the extracted heat of heat exchanger by changing the flow field while not radiation heat transfer of heat exchanger outer wall, and the difference between the extracted heat of heat exchanger embedded in packed bed and that of heat exchanger in empty bad is gradually obvious with gas temperature increasing under the condition of the same gas mass flow rate. In addition, under the same operating condition, when the two characteristic sizes of heat extraction zone honeycomb ceramic in the vertical gas flow direction increase, the extracted heat of embedded heat exchanger shows a trend of first increase while extracted heat of embedded heat exchanger shows a trend of decrease because the decreasing of the windward and leeward side gas flow velocity of heat exchanger results into weakening of convective heat transfer of embedded heat exchanger outer wall.  相似文献   

16.
Heat exchangers operating in process industries are fouled during operations and results in decrease in the thermal efficiency of a heat exchanger. Once the thermal efficiency decreases to a minimum acceptable level, cleaning of the equipment becomes necessary to restore the performance. This paper uses C-factor as a tool for investigation of the performance of a heat exchanger due to fouling which consequently gives information regarding the extent of fouling developed on the heat transfer surfaces. The fouling parameters are predicted by measurements of flow rate and pressure drop. In contrast to most conventional methods, the extent of fouling can be detected considering the flow rate and pressure drop when the heat exchanger operates in transient states. The C-Factor is first calculated through out cleaning period and then compared with the clean and the design value. The results show that the proposed tool is very effective in detecting the fouling developed and the corresponding degradation in heat transfer efficiency of a heat exchanger. Hence the results of this work can find applications in predicting the reduction in heat transfer efficiency due to fouling in heat exchangers that are in operation and assist the exchanger operators to plan cleaning schedules.  相似文献   

17.
The paper presents numerical investigations of a three fluid heat exchanger (TFHE), which is an improvement on the double pipe heat exchanger, where a helical tube is inserted in the annular space between two straight pipes. The helical tube side fluid, that is, hot water continuously transfers heat to the outer annulus side fluid and innermost tube side fluid. The heat transfer and pressure drop characteristics of the TFHE are assessed for different flow rates and inlet temperatures. With an increment in the volumetric flow rate of the helical tube side fluid and outer annulus side fluid, the overall heat transfer coefficient increases, and the effectiveness decreases for heat transfer from the helical tube side fluid to outer annulus side fluid in both parallel flow and counter flow configurations. It is also observed that with increment in the helical tube side fluid inlet temperature, the overall heat transfer coefficient and effectiveness increases for heat transfer from the helical tube side fluid to outer annulus side fluid in both flow configurations. The parameter, JF factor, has been proposed to evaluate the thermohydraulic behavior of the TFHE, where it is obtained that the behavior of the TFHE is better at a lower helical tube side fluid velocity and higher outer annulus side fluid velocity.  相似文献   

18.
对国内现有内燃机车用热交换器的传热机理和结构进行了分析、比较和研究,指出热交换器传热强化应采取的措施,并针对光管热交换器、螺旋扁管热交换器、螺旋隔板热交换器作了性能对比研究,指出螺旋隔板热交换器具有较高的冷却能力。  相似文献   

19.
In the present study, the thermal performance and pressure drop of the helical-coil heat exchanger with and without helical crimped fins are studied. The heat exchanger consists of a shell and helically coiled tube unit with two different coil diameters. Each coil is fabricated by bending a 9.50 mm diameter straight copper tube into a helical-coil tube of thirteen turns. Cold and hot water are used as working fluids in shell side and tube side, respectively. The experiments are done at the cold and hot water mass flow rates ranging between 0.10 and 0.22 kg/s, and between 0.02 and 0.12 kg/s, respectively. The inlet temperatures of cold and hot water are between 15 and 25 °C, and between 35 and 45 °C, respectively. The cold water entering the heat exchanger at the outer channel flows across the helical tube and flows out at the inner channel. The hot water enters the heat exchanger at the inner helical-coil tube and flows along the helical tube. The effects of the inlet conditions of both working fluids flowing through the test section on the heat transfer characteristics are discussed.  相似文献   

20.
Transient behavior of co-current parallel flow three-fluid compact heat exchangers with the effect of two-dimensional longitudinal heat conduction through the separating sheet and axial dispersion in fluids has been investigated numerically by using the Gauss–Seidel iterative technique for step excitation provided to hot fluid inlet temperature. The results reveal that the performance of the heat exchanger is affected when two-dimensional longitudinal conduction in separating sheets and axial dispersion in fluids are considered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏