1.
Heat transfer, friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes (STT) and plain twisted tapes (PTT) are investigated experimentally using the water as working fluid. The tapes (STT and PTT) have three twist ratios ( , 4.4 and 6.0) and the Reynolds number ranges from 2000 to 12000. The experimental results reveal that heat transfer rate, friction factor and thermal enhancement factor in the tube equipped with STT are significantly higher than those fitted with PTT. The additional disturbance and secondary flow in the vicinity of the tube wall generated by STT are higher compared to that induced by the PTT is referred as the reason for better performance. Over the range considered, the Nusselt number, friction factor and thermal enhancement factor in a tube with STT are respectively, 1.03 to 1.14, 1.05 to 1.25 and 1.02 to 1.06 times of those in tube with PTT. An empirical correlation is also formulated to match with experimental data of Nusselt number and friction factor for STT and PTT.  相似文献   

2.
The paper presents a 3D numerical simulation of turbulent heat transfer and flow characteristics in converging-diverging tubes(CDs) and converging-diverging tubes equipped with twin counter-swirling twisted tapes(CDTs).The effects of Reynolds number(Re 10000-20000),pitch length(P 11.25,22.5 mm),rib height(e 0.5,0.8,1.1 mm),pitch ratio(δ1:8,5:4,8︰1),gap distance between twin twisted tapes(b 0.5,4.5,8.5 mm) and tape number(n 2,3,4,5,6) on Nusselt number(Nu),friction factor(f) and thermal enhancement factor(η) are investigated under uniform heat flux conditions,using water as working fluid.In order to illustrate the heat transfer and fluid flow mechanisms,flow structures in CDs and CDTs are presented.The obtained results reveal that all geometric parameters have important effects on the thermal performance of CD and CDT,and both CD and CDT show better thermal performance than plain tube at the constant pumping power.It is also found that the increases in the Nusselt number and friction factor for CDT are,respectively,up to 6.3%-35.7% and 1.75-5.3 times of the corresponding bare CD.All CDTs have good thermal performance with η greater than 1 which indicates that the compound heat transfer technique of CDT is commendable for the maximum enhanced heat transfer rate.  相似文献   

3.
The convective heat transfer and friction behaviors of turbulent tube flow through a straight tape with double-sided delta wings(T-W)have been studied experimentally.In the current work,the T-W formed on the tape was used as vortex generators for enhancing the heat transfer coefficient by breakdown of thermal boundary layer and by mixing of fluid flow in tubes.The T-W characteristics are(1)T-W with forward/backward-wing arrangement,(2)T-W with alternate axis(T-WA),(3)three wing-width ratios and(4)wing-pitch ratios.The experimental result reveals that for using the T-W,the increases in the mean Nusselt number(Nu)and friction factor are,respectively,up to 165%and 14.8 times of the plain tube and the maximum thermal performance factor is 1.19.It is also obvious that the T-W with forward-wing gives higher heat transfer rate than one with backward-wing around 7%. The present investigation also shows that the heat transfer rate and friction factor obtained from the T-WA is higher than that from the T-W.In addition,the flow pattern and temperature fields in the T-W tube with both backward and forward wings were also examined numerically.  相似文献   

4.
Experimental and numerical investigations have been conducted to study turbulent flow of water and heat transfer characteristics in a rectangular channel with discontinuous crossed ribs and grooves.The tests investigated the overall heat transfer performance and friction factor in ribbed and ribbed-grooved channels with rib angle of 30°.The experimental results show that the overall thermo-hydraulic performance for ribbed-grooved channel is increased by 10%-13.6% when compared to ribbed channel.The investigation on the effects of different rib angles and rib pitches on heat transfer characteristics and friction factor in ribbed-grooved channel was carried out using Fluent with SST(shear-stress transport) k-ω turbulence model.The numerical results indicate that the case for rib angle of 45° shows the best overall thermo-hydraulic performance,about 18%-36% higher than the case for rib angle of 0°.In addition,the flow patterns and local heat transfer characteristics for ribbed and ribbed-grooved channels based on the numerical simulation were also analyzed to reveal the mechanism of heat transfer enhancement.  相似文献   

5.
A 3D numerical investigation has been carried out to examine periodic laminar flow and heat transfer character-istics in a circular tube with 45° V-baffles with isothermal wal . The computations are based on the finite volume method (FVM), and the SIMPLE algorithm has been implemented. The fluid flow and heat transfer characteristics are presented for Reynolds numbers ranging from 100 to 2000. To generate main longitudinal vortex flows through the tested section, V-baffles with an attack angle of 45° are mounted in tandem and in-line arrangement on the opposite positions of the circular tube. Effects of tube blockage ratio, flow direction on heat transfer and pressure drop in the tube are studied. It is apparent that a pair of longitudinal twisted vortices (P-vortex) created by a V-baffle can induce impingement on a wal of the inter-baffle cavity and lead a drastic increase in heat trans-fer rate at tube wall. In addition, the larger blockage ratio results in the higher Nusselt number and friction factor values. The computational results show that the optimum thermal enhancement factor is around 3.20 at baffle height of B=0.20 and B=0.25 times of the tube diameter for the V-upstream and V-downstream, respectively. ? 2014 The Chemical Industry and Engineering Society of China, and Chemical Industry Press. Al rights reserved.  相似文献   

6.
The paper presents an experimental study on the heat transfer and flow friction characteristics in a solar air heater channel fitted with delta-winglet type vortex generators (DWs). The experiments are conducted by varying the airflow rate for Reynolds number in the range of 5000 to 24000 in the test section with a uniform heat-flux applied on the upper channel wall. Firstly, the DW pairs are mounted only at the entrance of the lower wall of the test channel (called DW-E) to create multiple vortex flows at the entry. The effect of two transverse pitches (Re= Pt/H= 1 and 2) at three attack angles (a= 30°, 45° and 60°) of the DW-E with its relative height, b/H= 0.5 (half height of channel) is examined. Secondly, the 30° DWs with three different relative heights (blH = 0.3, 0.4 and 0.5) are placed on the upper wall only (absorber plate, called DW-A) of the test channel. The experimental result reveals that in the first case, the 60° DW-E at Rp = 1 provides the highest heat transfer and friction factor while the 30° DW-E at Rp = 1 performs overall better than the others. In the second case, the 30° DW-A at b/H= 0.5 yields the highest heat transfer and friction factor but the best thermal performance is found at b/H = 0.4.  相似文献   

7.
恒热流直管中纳米流体对流传热的实验研究(英文)   总被引:1,自引:0,他引:1  
In this work, the laminar convective heat transfer performance and the pressure drop of water-based nanofluids containing Al2O3, TiO2 and SiO2 nanoparticles flowing through a straight circular tube were experimen-tally investigated. The experimental results showed that addition of small amounts of nano-sized Al2O3 and TiO2 particles to de-ionized water increased heat transfer coefficients considerably, while the SiO2 nanofluids showed the opposite behavior attracting the authors’ interests. An average of 16%and 8.2%increase in heat transfer coefficient were observed with the average of 28%and 15%penalty in pressure drop for Al2O3 and TiO2 nanofluids.  相似文献   

8.
不同折流板结构螺旋折流板换热器传热性能的比较(英文)   总被引:1,自引:0,他引:1  
Numerical simulations were performed on flow and heat transfer performances of heat exchangers having six helical baffles of different baffle shapes and assembly configurations, i.e., two trisection baffle schemes, two quadrant baffle schemes, and two continuous helical baffle schemes. The temperature contour or the pressure contour and velocity contour plots with superimposed velocity vectors on meridian, transverse and unfolded concentric hexagonal slices are presented to obtain a full angular view. For the six helix baffled heat exchangers, the different patterns of the single vortex secondary flow and the shortcut leakage flow were depicted as wel as the heat transfer properties were compared. The results show that the optimum scheme among the six configurations is a circumferential overlap trisection helix baffled heat exchanger with a baffle incline angle of 20° (20°TCO) scheme with an anti-shortcut baffle structure, which exhibits the second highest pressure dropΔpo, the highest overal heat transfer coefficient K, shel-side heat transfer coefficient ho and shel-side average comprehensive index ho/Δpo.  相似文献   

9.
Numerical solution of yield viscoplastic fluid flow is hindered by the singularity inherent to the Herschel-Bulkley model.A finite difference method over the boundary-fitted orthogonal coordinate system is util-ized to investigate numerically the fully developed steady flow of non-Newtonian yield viscoplastic fluid through concentric and eccentric annuli.The fluid rheology is described with the Herschel-Bulkley model.The numerical simulation based on a continuous viscoplastic approach to the Herschel-Bulkley model is found in poor accordance with the experimental data on volumetric flow rate of a bentonite suspension.A strict mathematical model for Herschel-Bulkley fluid flow is established and the corresponding numerical procedures are proposed.However,only the case of flow of a Herschel-Bulkley fluid in a concentric annulus is resolved based on the presumed flow structure by using the common optimization technique.Possible flow structures in an eccentric annulus are pre-sumed,and further challenges in numerical simulation of the Herschel-Bulkley fluid flow are suggested.  相似文献   

10.
《云南化工》2019,(9):30-32
通过数值模拟对内置偏心多螺旋扭带换热管的传热特性进行了计算与分析,结果表明:换热管的对流传热强度随着扭带数量的增加而提高,随着扭带扭率的减小而提高。流动阻力损失相对于空管有很大程度的提高。传热性能评价指标在湍流时普遍较低,故多螺旋扭带换热管的使用应考虑流动阻力损失的影响。  相似文献   

11.
The influences of circular-ring turbulators (CRT) and twisted tape (TT) swirl generators on the heat transfer enhancement, pressure drop and thermal performance factor characteristics in a round tube are reported. The circular-ring turbulators were individually employed and together with the twisted tape swirl generators in the heated section of the tube. Three different pitch ratios (l/D1.0, 1.5, and 2.0) of the CRT and three different twist ratios (y/W 3, 4, and 5) of the TT were introduced. The experiments were conducted using air as the working fluid under a uniform wall heat flux condition, for the Reynolds number between 6000 and 20000. The experimental results reveal that the heat transfer rate, friction factor and thermal performance factor of the combined CRT and TT are considerably higher than those of CRT alone. For the range examined, the increases of mean Nusselt number, friction factor and thermal performance, in the tube equipped with combined devices, respectively, are 25.8%, 82.8% and 6.3% over those in the tube with the CRT alone. The highest thermal performance factor of 1.42 is found for the combined device consisting of the CRT with l/D 1.0 and TT with y/W 3. The correlations of the Nusselt number, friction factor and thermal performance factor of the tubes with combined devices are also developed in terms of Reynolds number, Prandtl number, twist ratio and pitch ratio.  相似文献   

12.
本文对内置叶片开槽间断型转子换热管的强化传热及阻力特性进行了实验研究。在雷诺数为15000~45000范围内对光管进行了验证性实验,得出努塞尔数Nu和阻力系数f误差分别在-3.0%~+3.5%和9.0%以内。在实验条件下,内置叶片开槽间断型转子的换热管与光管相比,努塞尔数Nu和阻力系数f分别平均提高了70.03%和83.88%。通过综合性能评价得出PEC值在1.38~1.40之间。  相似文献   

13.
基于纳米流体单相数值模拟方法,对纳米流体协同扭带插入物强化螺旋圆管传热特性进行研究,分析了进口流速0.01~0.07 m/s范围内,纯水以及纳米颗粒粒径为30、40、50、60 nm的Al_2O_3水基纳米流体对内置扭带插入物螺旋圆管努塞尔数的影响。结果表明,纳米流体可以提高努塞尔数,提升效果随着纳米颗粒粒径的减小而增加。通过场协同分析,热流场和速度场的协同程度验证了上述结果。  相似文献   

14.
以去离子水为工质,研究了钛合金螺旋扭曲管内的强化传热与流阻性能,并与钛合金圆管比较;根据实验数据拟合螺旋扭曲管内努塞尔特数和阻力系数的实验关联式,并与经典对流传热关联式比较. 结果表明,Dittus?Boelter方程、Sieder?Tate方程、Михеев方程和Gnielinski方程适用于模拟螺旋扭曲管内对流换热特性.  相似文献   

15.
The objective of this work was to investigate nucleate pool boiling heat transfer performance and mechanism of R134a and R142b on a twisted tube with machine processed porous surface (T-MPPS tube) as well as to determine its potential application to flooded refrigerant evaporators. In the experimental range, the boiling heat transfer coefficients of R134a on a T-MPPS tube were 1.8-2.0 times larger than those of R134a on a plain tube. In addition, the developed experimental correlations verified that the predictions of the heat transfer coefficients of boiling R134a and R142bon a T-MPPS tube at the experimental conditions were considerably accurate.  相似文献   

16.
本文概述了转子组合式强化传热装置的强化传热和自清洁原理,通过实验研究了传热和阻力特性。实验结果表明,在相同的雷诺数条件下,内置螺旋叶片转子换热管的努塞尔数明显高于光管的努塞尔数,说明具有良好的强化传热效果;内置螺旋叶片转子换热管的阻力系数显著高于光管阻力系数,说明在强化传热的同时,使得管内阻力随之增加。此外,作者借助多元线性回归方法,建立了内置螺旋叶片转子换热管的努塞尔数与阻力系数的经验关联式。  相似文献   

17.
含间隔分置旋流片的缩放管复合强化传热   总被引:3,自引:0,他引:3  
Pressure drop and compound heat transfer characteristics of a converging-diverging tube with evenly spaced twisted-tapes (CD-T tube) have been investigated experimentally. Swirl was generated by evenly spaced twisted-tape elements which vary in twist ratio and rotation angle. Space ratio also has an important effect on the characteristics. For comparison, experiments in a smooth circular tube and a converging-diverging (CD) tube with-out twisted-tapes were carried out. The results show that the twisted-tape with twist ratio y=4.72 and rotation angle θ=180° has the best performance among the four types of twisted-tapes presented in this paper. At Reynolds number ranging from 3400 to 20000, when space ratio s=48.6, the heat transfer efficiency index, which increases as the Reynolds number increases, is 0.85-1.21 and 1.07-1.15 compared to that of a smooth circular tube and a CD tube without twisted-tape inserts, respectively.  相似文献   