首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The human chorionic gonadotropin (hCG) proteins constitute a diverse group of molecules that displays biomarker value in pregnancy detection and cancer diagnostics, as well as in doping analysis. For the quantification of hCGβ and qualitative differentiation between other hCG variants in a selective, sensitive, and reproducible manner, the targeted proteomics approach based on mass spectrometric (MS) selected reaction monitoring (SRM) detection was exploited. By optimizing immunoaffinity extraction using monoclonal antibodies coated to magnetic beads, access was granted for the MS to the low-abundance target proteins, ensuring proper sensitivity with limits of detection (LODs) of 2 and 5 IU/L, respectively, for urine and serum samples. Validation according to key elements and recommendations defined by the European Medicines Agency in Guideline on Validation of Bioanalytical Methods was performed. For both matrixes this demonstrated good within-day precision results (within 20% for the lowest concentration, and within 15% for the medium and high concentration), good accuracy results (within 15% for all concentrations), and proper linearity, >0.997 for serum and of 0.999 for urine, in the concentration range up to 5000 IU/L. The method's application in clinical diagnostics was tested on samples from a pregnant woman and from patients previously diagnosed with testicular cancer. For doping analysis, samples from one man having received injection of the hCG-containing pharmaceutical Pregnyl were analyzed. The method proved to be quantitatively accurate with indisputable identification specificity, reducing risks of false positive and false negative results. The successfully validated method advocates thus for more extended use of MS in routine analysis.  相似文献   

2.
Cancer diagnosis and patient monitoring require sensitive and simultaneous measurement of multiple cancer biomarkers considering that single biomarker analysis present inadequate information on the underlying biological transformations. Thus, development of sensitive and selective assays for multiple biomarker detection might improve clinical diagnosis and expedite the treatment process. Herein, a microfluidic platform for the rapid, sensitive, and parallel detection of multiple cancer‐specific protein biomarkers from complex biological samples is presented. This approach utilizes alternating current electrohydrodynamic‐induced surface shear forces that provide exquisite control over fluid flow thereby enhancing target–sensor interactions and minimizing non‐specific binding. Further, the use of surface‐enhanced Raman scattering‐based spectral encoding with individual barcodes for different targets enables specific and simultaneous detection of captured protein biomarkers. Using this approach, the specific and sensitive detection of clinically relevant biomarkers including human epidermal growth factor receptor 2 (HER2); Mucin 1, cell surface associated (MUC1); epidermal growth factor receptor; and Mucin 16, cell surface associated (MUC16) at concentrations as low as 10 fg mL?1 in patient serum is demonstrated. Successful target detection from patient samples further demonstrates the potential of this current approach for the clinical diagnosis, which envisages a clinical translation for a rapid and sensitive appraisal of clinical samples in cancer diagnostics.  相似文献   

3.
Protein chip technology permits analysis of the expression and modification status of numerous targeted proteins within a single experiment, mainly through the use of antibody-based microarrays. Despite recent improvements in these protein chips, their applications are still limited for a variety of reasons, which include technical challenges in fabrication of the antibody chips as well as the very low specificity achieved by current detection methods. We have developed a unique approach for relative and/or absolute quantitation of protein expression and modification based on the capture of epitope peptides on affinity beads, which can be used to develop a mass-spectrometry-based protein chip technology. This new method, which utilizes antibodies immobilized on beads for the capture of target peptides, instead of proteins, eliminates many of the problems previously associated with protein chips. We present here several proof-of-principle experiments examining model peptides by this technique. These experiments show that the method is capable of (i). detecting peptides bound to a single antibody bead, (ii). detecting peptides at low (fmol) levels, (iii). producing MS/MS data of suitable quality for protein identification via database searching or de novo sequencing, (iv). quantitating peptides affinity-bound to antibody beads, (v). specifically detecting target peptides in complex mixtures over wide dynamic ranges, and (vi) is compatible with a microarray format for high-throughput analysis. Because our novel method uses antibody beads instead of a derivatized capture surface, and peptides instead of proteins for affinity capture, it can overcome many of the pitfalls of previous protein chip fabrications. Therefore, this method offers an improved approach to protein chip technology that should prove useful for diagnostics and drug development applications.  相似文献   

4.
Electrochemical coding for multiplexed immunoassays of proteins   总被引:1,自引:0,他引:1  
Liu G  Wang J  Kim J  Jan MR  Collins GE 《Analytical chemistry》2004,76(23):7126-7130
An electrochemical immunoassay protocol for the simultaneous measurements of proteins, based on the use of different inorganic nanocrystal tracers is described. The multiprotein electrical detection capability is coupled to the amplification feature of electrochemical stripping transduction (to yield fmol detection limits) and with an efficient magnetic separation (to minimize nonspecific adsorption effects). The multianalyte electrical sandwich immunoassay involves a dual binding event, based on antibodies linked to the nanocrystal tags and magnetic beads. Carbamate linkage is used for conjugating the hydroxyl-terminated nanocrystals with the secondary antibodies. Each biorecognition event yields a distinct voltammetric peak, whose position and size reflects the identity and level, respectively, of the corresponding antigen. The concept is demonstrated for a simultaneous immunoassay of beta(2)-microglobulin, IgG, bovine serum albumin, and C-reactive protein in connection with ZnS, CdS, PbS, and CuS colloidal crystals, respectively. These nanocrystal labels exhibit similar sensitivity. Such electrochemical coding could be readily multiplexed and scaled up in multiwell microtiter plates to allow simultaneous parallel detection of numerous proteins or samples and is expected to open new opportunities for protein diagnostics and biosecurity.  相似文献   

5.
We describe a method for multiplexed analysis of proteins using fluorescently encoded microbeads. The sensitivity of our method is comparable to the sensitivity obtained by enzyme-linked immunosorbent assay while only 5 µl sample volumes are needed. Streptavidin-coated, 1 µm beads are encoded with a combination of fluorophores at different intensity levels. As a proof of concept, we demonstrate that 27 microbead populations can be readily encoded by affinity conjugation using three intensity levels for each of three different biotinylated fluorescent dyes. Four populations of encoded microbeads are further conjugated with biotinylated capture antibodies and then combined and immobilized in a microfluidic flow cell for multiplexed protein analysis. Using four uniquely encoded microbead populations, we show that a cancer biomarker and three cytokine proteins can be analysed quantitatively in the picogram per millilitre range by fluorescence microscopy in a single assay. Our method will allow for the fabrication of high density, bead-based antibody arrays for multiplexed protein analysis using integrated microfluidic devices and automated sample processing.  相似文献   

6.
The first application of nanocrystal (NC)-encoded microbeads to clinical proteomics is demonstrated by multiplexed detection of circulating autoantibodies, markers of systemic sclerosis. Two-color complexes, consisting of NC-encoded, antigen-covered beads, anti-antigen antibody or clinical serum samples, and dye-tagged detecting antibodies, were observed using flow cytometry assays and on the surface of single beads. The results of flow cytometry assays correlated with the ELISA technique and provided clear discrimination between the sera samples of healthy donors and patients with autoimmune disease. Microbead fluorescence signals exhibited narrow distribution regardless of their surface antigen staining, without the need of any fluorescence compensation-a parameter determining the limit of sensitivity of flow cytometry assays. In single bead measurements, less than 30 dye-labeled antibodies interacting with the topoI-specific antibodies at the surface of a bead have been detected by the emission of dye excited through the FRET from NCs. In this format, the antibody-bead interaction reaction turns specifically the fluorescence signal from dye label off and on, additionally increasing autoantibody detection sensitivity.  相似文献   

7.
A nanoscale insulator‐based dielectrophoresis (iDEP) technique is developed for rapid enrichment of proteins and highly sensitive immunoassays. Dense arrays of nanorods (NDs) by oblique angle deposition create a super high electric field gradient of 2.6 × 1024 V2 m?3 and the concomitant strong dielectrophoresis force successfully traps small proteins at a bias as low as 5 V. 1800‐fold enrichment of bovine serum albumin protein at a remarkable rate of up to 180‐fold s?1 is achieved using oxide coated Ag nanorod arrays with pre‐patterned sawtooth electrodes. Based on this system, an ultrasensitive immunoassay of mouse immunoglobulin G is demonstrated with a reduction in the limit of detection from 5.8 ng mL?1 (37.6 pM) down to 275.3 fg mL?1 (1.8 f M), compared with identical assays performed on glass plates. This methodology is also applied to detect a cancer biomarker prostate‐specific antigen spiked in human serum with a detection limit of 2.6 ng mL?1. This high sensitivity results from rapid biomarker enrichment and metal enhanced fluorescence through the integration of nanostructures. The concentrated proteins also accelerate binding kinetics and enable signal saturation within 1 min. Given the easy fabrication process, this nanoscale iDEP system provides a highly sensitive detection platform for point‐of‐care diagnostics.  相似文献   

8.
This paper describes fabrication of a novel electrochemiluminescence (ECL) immunosensor array featuring capture-antibody-decorated single-wall carbon nanotube (SWCNT) forests residing in the bottoms of 10-μL wells with hydrophobic polymer walls. Silica nanoparticles containing [Ru(bpy)(3)](2+) and secondary antibodies (RuBPY-silica-Ab(2)) are employed in this system for highly sensitive two-analyte detection. Antibodies to prostate specific antigen (PSA) and interleukin-6 (IL-6) were attached to the same RuBPY-silica-Ab(2) particle. The array was fabricated by forming the wells on a conductive pyrolytic graphite chip (1 in. × 1 in.) with a single connection to a potentiostat to achieve ECL. The sandwich immunoassay protocol employs antibodies attached to SWCNTs in the wells to capture analyte proteins. Then RuBPY-silica-Ab(2) is added to bind to the captured proteins. ECL is initiated in the microwells by electrochemical oxidation of tripropyl amine (TprA), which generates excited state [Ru(bpy)(3)](2+) in the 100-nm particles, and is measured with a charge-coupled device (CCD) camera. Separation of the analytical spots by the hydrophobic wall barriers enabled simultaneous immunoassays for two proteins in a single sample without cross-contamination. The detection limit (DL) for PSA was 1 pg mL(-1) and for IL-6 was 0.25 pg mL(-1) (IL-6) in serum. Array determinations of PSA and IL-6 in patient serum were well-correlated with single-protein ELISAs. These microwell SWCNT immunoarrays provide a simple, sensitive approach to the detection of two or more proteins.  相似文献   

9.
Despite great interest, investments, and efforts, the ongoing search for plasma protein biomarkers for disease so far has come up surprisingly empty-handed. Although discovery programs have revealed large numbers of biomarker candidates, the clinical utility has been validated for only a very small number of these. While this disappointing state of affairs may suggest that plasma protein biomarkers have little more to offer for diagnostics, we take the perspective that experimental conditions might not have been optimal and that analyses will be required that offer far greater sensitivity than currently available, in terms of numbers of molecules needed for unambiguous detection. Accordingly, techniques are needed to search deep and wide for protein biomarker candidates. The requirements and feasibility of such assays will be discussed.  相似文献   

10.
We report a method for combining the detection of single molecules (digital) and an ensemble of molecules (analog) that is capable of detecting enzyme label from 10(-19) M to 10(-13) M, for use in high sensitivity enzyme-linked immunosorbent assays (ELISA). The approach works by capturing proteins on microscopic beads, labeling the proteins with enzymes using a conventional multistep immunosandwich approach, isolating the beads in an array of 50-femtoliter wells (Single Molecule Array, SiMoA), and detecting bead-associated enzymatic activity using fluorescence imaging. At low concentrations of proteins, when the ratio of enzyme labels to beads is less than ~1.2, beads carry either zero or low numbers of enzymes, and protein concentration is quantified by counting the presence of "on" or "off" beads (digital regime). (1) At higher protein concentrations, each bead typically carries multiple enzyme labels, and the average number of enzyme labels present on each bead is quantified from a measure of the average fluorescence intensity (analog regime). Both the digital and analog concentration ranges are quantified by a common unit, namely, average number of enzyme labels per bead (AEB). By combining digital and analog detection of singulated beads, a linear dynamic range of over 6 orders of magnitude to enzyme label was achieved. Using this approach, an immunoassay for prostate specific antigen (PSA) was developed. The combined digital and analog PSA assay provided linear response over approximately four logs of concentration ([PSA] from 8 fg/mL to 100 pg/mL or 250 aM to 3.3 pM). This approach extends the dynamic range of ELISA from picomolar levels down to subfemtomolar levels in a single measurement.  相似文献   

11.
Sandhu A  Handa H  Abe M 《Nanotechnology》2010,21(44):442001
Functionalized magnetic nanoparticles are important components in biorecognition and medical diagnostics. Here, we present a review of our contribution to this interdisciplinary research field. We start by describing a simple one-step process for the synthesis of highly uniform ferrite nanoparticles (d = 20-200 nm) and their functionalization with amino acids via carboxyl groups. For real-world applications, we used admicellar polymerization to produce 200 nm diameter 'FG beads', consisting of several 40 nm diameter ferrite nanoparticles encapsulated in a co-polymer of styrene and glycidyl methacrylate for high throughput molecular screening. The highly dispersive FG beads were functionalized with an ethylene glycol diglycidyl ether spacer and used for affinity purification of methotrexate-an anti-cancer agent. We synthesized sub-100 nm diameter magnetic nanocapsules by exploiting the self-assembly of viral capsid protein pentamers, where single 8, 20, and 27 nm nanoparticles were encapsulated with VP1 pentamers for applications including MRI contrast agents. The FG beads are now commercially available for use in fully automated bio-screening systems. We also incorporated europium complexes inside a polymer matrix to produce 140 nm diameter fluorescent-ferrite beads (FF beads), which emit at 618 nm. These FF beads were used for immunofluorescent staining for diagnosis of cancer metastases to lymph nodes during cancer resection surgery by labeling tumor cell epidermal growth factor receptor (EGFRs), and for the detection of brain natriuretic peptide (BNP)-a hormone secreted in excess amounts by the heart when stressed-to a level of 2.0 pg ml(-1). We also describe our work on Hall biosensors made using InSb and GaAs/InGaAs/AlGaAs 2DEG heterostructures integrated with gold current strips to reduce measurement times. Our approach for the detection of sub-200 nm magnetic bead is also described: we exploit the magnetically induced capture of micrometer sized 'probe beads' by nanometer sized 'target beads', enabling the detection of small concentrations of beads as small as 8 nm in 'pumpless' microcapillary systems. Finally, we describe a 'label-less homogeneous' procedure referred to as 'magneto-optical transmission (MT) sensing', where the optical transmission of a solution containing rotating linear chains of magnetic nanobeads was used to detect biomolecules with pM-level sensitivity with a dynamic range of more than four orders of magnitude. Our research on the synthesis and applications of nanoparticles is particularly suitable for point of care diagnostics.  相似文献   

12.
Due to the ability to detect multiple parameters simultaneously, protein microarrays have found widespread applications from basic biological research to diagnosis of diseases. Generally, readout of protein microarrays is performed by fluorescence detection using either dye-labeled detector antibodies or direct labeling of the target proteins. We developed a method for the label-free detection and quantification of proteins based on time-gated, wide-field, camera-based UV fluorescence lifetime imaging microscopy to gain lifetime information from each pixel of a sensitive CCD camera. The method relies on differences in the native fluorescence lifetime of proteins and takes advantage of binding-induced lifetime changes for the unequivocal detection and quantification of target proteins. Since fitting of the fluorescence decay for every pixel in an image using a classical exponential decay model is time-consuming and unstable at very low fluorescence intensities, we used a new, very robust and fast alternative method to generate UV fluorescence lifetime images by calculating the average lifetime of the decay for each pixel in the image stack using a model-free average decay time algorithm.To validate the method, we demonstrate the detection and quantification of p53 antibodies, a tumor marker in cancer diagnosis. Using tryptophan-containing capture peptides, we achieved a detection sensitivity for monoclonal antibodies down to the picomolar concentration range. The obtained affinity constant, Ka, of (1.4 +/- 0.6) x 10(9) M(-1), represents a typical value for antigen/antibody binding and is in agreement with values determined by traditional binding assays.  相似文献   

13.
Rapid and sensitive detection of serum tumor biomarkers are needed to monitor cancer patients for disease progression. Highly sensitive piezoelectric microcantilever sensors (PEMS) offer an attractive tool for biomarker detection; however, their utility in the complex environment encountered in serum has yet to be determined. As a proof of concept, we have functionalized PEMS with antibodies that specifically bind to HER2, a biomarker (antigen) that is commonly overexpressed in the blood of breast cancer patients. The function and sensitivity of these anti-HER2 PEMS biosensors was initially assessed using recombinant HER2 spiked into human serum. Their ability to detect native HER2 present in the serum of breast cancer patients was then determined. We have found that the anti-HER2 PEMS were able to accurately detect both recombinant and naturally occurring HER2 at clinically relevant levels (>2 ng/mL). This indicates that PEMS-based biosensors provide a potentially effective tool for biomarker detection.  相似文献   

14.
A rapid, specific, and sensitive method for the detection of protein-protein interactions is of crucial importance for drug discovery and clinical diagnostics. Mass spectrometry plays a major role in the analysis of proteins, but its application to the routine analysis of protein complexes has been lagging behind. A new strategy for high-throughput analysis of protein interactions is presented here. We demonstrate application to immunochemical questions such as epitope mapping, kinetic studies, and sandwich assays. The methodology is based on a direct mass spectrometric readout for antigen-antibody complexes in the 150-400 kDa range. This has become possible using a novel detector technology and chemical cross-linking to stabilize complexes for analysis by MALDI MS. We demonstrate high detection sensitivity (femtomole quantities of antigen), high specificity (specific detection of antigen directly in serum), high accuracy, and high speed (minutes per assay), surpassing conventional analytical methods by more than 2 orders of magnitude.  相似文献   

15.
A photonic crystal (PC) surface is demonstrated as a high-sensitivity platform for detection of a panel of 21 cancer biomarker antigens using a sandwich enzyme-linked immunosorbent assay (ELISA) microarray format. A quartz-based PC structure fabricated by nanoimprint lithography, selected for its low autofluorescence, supports two independent optical resonances that simultaneously enable enhancement of fluorescence detection of biomarkers and label-free quantification of the density of antibody capture spots. A detection instrument is demonstrated that supports fluorescence and label-free imaging modalities, with the ability to optimize the fluorescence enhancement factor on a pixel-by-pixel basis throughout the microarray using an angle-scanning approach for the excitation laser that automatically compensates for variability in surface chemistry density and capture spot density. Measurements show that the angle-scanning illumination approach reduces the coefficient of variation of replicate assays by 20-99% compared to ordinary fluorescence microscopy, thus supporting reduction in limits of detectable biomarker concentration. Using the PC resonance, biomarkers in mixed samples were detectable at the lowest concentrations tested (2.1-41 pg/mL), resulting in a three-log range of quantitative detection.  相似文献   

16.
While advances in assay chemistry and detection continue to improve molecular diagnostics technology, blood samples are still collected using the 150-year-old needle/syringe method. Surface modified microprojection arrays have been developed as a novel platform for in vivo, needle-free biomarker capture. These devices are gold coated silicon arrays with >20,000 projections per cm(2), which can be applied to the skin for tunable penetration into the epidermis or dermis. The microprojection array conceptually offers several advantages over the current methods including: minimally invasive sample collection, no need for sample processing and concentration of specific markers at the device surface for sensitive detection. In this study, Microprojection arrays were coated with antibodies to capture an early marker of dengue virus infection, NS1, from the skin of live mice. We also developed a complementary "total IgG" assay which could be used as a positive control for adequate penetration of the projections. Surface modifications designed for selective extraction were tested against standard microtiter plate ELISA. We also investigated the use of Protein G-mediated antibody immobilization in order to orient capture antibodies. While we found that capture efficiency could be improved, the direct EDC-based antibody immobilization resulted in a significantly higher surface density leading to a higher degree of NS1 capture. Using mice intravenously injected with recombinant dengue virus type 2 NS1 as a pseudomodel for dengue infection, NS1 was successfully extracted using microprojection arrays sampling from skin fluid, with a detection limit of 8 μg/mL.  相似文献   

17.
A microarray immunoassay for simultaneous detection of proteins and bacteria   总被引:11,自引:0,他引:11  
We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).  相似文献   

18.
This paper reports a method that combines self-assembled monolayers with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to perform immunoassays on clinical samples. The immunosensors are prepared by immobilizing His-tagged protein G (or A) to a monolayer presenting the Ni2+ chelates, followed by immobilization of IgG antibodies with specificity for the intended analyte. The SAMDI mass spectrometry technique confirms the presence of the two proteins on the immunosensor and additionally provides a label-free analysis of antigens that bind to the sensor. This paper reports examples of detecting several proteins from human serum, including multianalyte assays that resolve each analyte according to their mass-to-charge ratio in the SAMDI spectra. An example is described wherein SAMDI is used to identify a proteolytic fragment of cystatin C in cerebral spinal fluids from patients diagnosed with multiple sclerosis. The SAMDI-TOF immunoassay, which combines well-defined surface chemistries for the selective and reproducible localization of analytes with mass spectrometry for label-free detection of analytes, may offer an alternative methodology to address many of the issues associated with standardized clinical diagnostics.  相似文献   

19.
This paper presents a new signal transduction method, called label-acquired magnetorotation (LAM), for the measurement of the concentration of proteins in solution. We demonstrate the use of LAM to detect the protein thrombin using aptamers, with a limit of detection of 300 pM. LAM is modeled after a sandwich assay, with a 10 μm nonmagnetic "mother" sphere as the capture component and with 1 μm magnetic "daughter" beads as the labels. The protein-mediated attachment of daughter beads to the mother sphere forms a rotating sandwich complex. In a rotating magnetic field, the rotational frequency of a sandwich complex scales with the number of attached magnetic beads, which scales with the concentration of the protein present in solution. This paper represents the first instance of the detection of a protein using LAM.  相似文献   

20.
The slow development of cost‐effective medical microdevices with strong analytical performance characteristics is due to a lack of selective and efficient analyte capture and signaling. The recently developed programmable nano‐bio‐chip (PNBC) is a flexible detection device with analytical behavior rivaling established macroscopic methods. The PNBC system employs ≈300 μm‐diameter bead sensors composed of agarose “nanonets” that populate a microelectromechanical support structure with integrated microfluidic elements. The beads are an efficient and selective protein‐capture medium suitable for the analysis of complex fluid samples. Microscopy and computational studies probe the 3D interior of the beads. The relative contributions that the capture and detection of moieties, analyte size, and bead porosity make to signal distribution and intensity are reported. Agarose pore sizes ranging from 45 to 620 nm are examined and those near 140 nm provide optimal transport characteristics for rapid (<15 min) tests. The system exhibits efficient (99.5%) detection of bead‐bound analyte along with low (≈2%) nonspecific immobilization of the detection probe for carcinoembryonic antigen assay. Furthermore, the role analyte dimensions play in signal distribution is explored, and enhanced methods for assay building that consider the unique features of biomarker size are offered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号