首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
One hundred fifteen hips in 108 patients with primary total hip arthroplasty using the anatomic porous replacement hemispheric acetabular component implanted without adjunctive screw fixation had a mean postoperative followup time of 6 years (range, 5-7.4 years). Clinical evaluation was performed using the Harris hip score and patient self assessment using a modified Short Form-36 questionnaire. Radiographs were measured for radiolucent lines, polyethylene wear, osteolysis, migration, and fractures. No acetabular metal shell had been revised for loosening or was radiographically loose with or without migration (more than 3 mm) at final followup. Reoperation was done in nine (8%) hips because of polyethylene insert wear or disassembly. No fracture of the acetabular bone occurred at the time of surgery or was observed on radiograph. Fixation of the metal shell was stable, with progressive radiolucent lines observed at final followup in 2% of the hips. Osteolysis was recorded in one patient with two acetabular components. The fixation of noncemented hemispheric porous coated acetabular components is more related to the technique of acetabular bone preparation and press fit implantation than to whether additional screws or peg fixation are used. Fixation of this acetabular component without screws at an average of 6 years after surgery is reproducible and predictable in primary hip arthroplasty. The design of modular polyethylene inserts has been improved and should reduce the wear rate of reoperations of the polyethylene insert.  相似文献   

2.
Twenty-four hip replacements were performed with use of a medial protrusio technique to stabilize the fit of a hemispherical metal shell in the acetabulum in nineteen patients who had dysplasia of the hip. All of the hips were followed for a minimum of five years (average, seven years; range, five to thirteen years). Six of the hips were type I, seven were type II, eight were type III, and three were type IV according to the criteria of Crowe et al. The acetabular cup was implanted with the medial aspect of its dome beyond the Kohler line (drawn from the ischium along the ilioischial line) in all hips. An autogenous graft sculpted from the femoral head was used to cover 15 to 30 percent of the superolateral portion of the cup in one type-I hip, four type-III hips, and one type-IV hip. The need for these six bone grafts could have been avoided by reaming two to three millimeters more medially or by allowing 20 percent of the superolateral portion of the cup to be uncovered. Sixty to 84 percent of each bone graft was resorbed, effectively leaving the superolateral portion of the cup uncovered. The amount of the surface of the cup that was beyond the Kohler line averaged 41 percent for the six type-I hips, 43 percent for the seven type-II hips, 41 percent for six of the type-III hips, and 44 percent for one of the type-IV hips. Crossing of the ilioischial and iliopubic lines was noted on the radiographs of two type-III and two type-IV hips. Radiographs of two type-I hips and one type-II hip showed 7 to 17 percent of the surface of the dome of the cup through the internal pelvic wall (beyond the iliopubic line). None of the twenty-four metal shells were revised. A reoperation was performed on two hips to exchange a worn polyethylene insert, and three femoral components that had been fixed without cement were revised because of mechanical loosening. Wear averaged 0.26 millimeter per year in the fourteen hips that had a titanium femoral head and 0.09 millimeter per year in the nine hips that had a cobalt-chromium femoral head. The remaining hip had a ceramic femoral head, and the wear rate was 0.09 millimeter per year. The medial protrusio technique is a predictable, reproducible method for obtaining fixation of a porous-coated, hemispherical acetabular component in a dysplastic acetabulum. The technique permits the use of a porous-coated (bone-ingrowth) component; avoids the use of support bone graft and thereby reduces the operative time; facilitates rehabilitation by permitting earlier weight-bearing of the hip; and permits the use of a modular bearing surface, which may allow future exchange of only this surface rather than revision of the entire acetabular component because of excessive wear.  相似文献   

3.
Total hip replacement was performed in 119 patients (124 hips) with an uncemented Ortholoc femoral component between 1982 and 1987. Eight patients (9 hips) died, and 13 patients (15 hips) were lost to follow-up, leaving 98 patients (100 hips) followed for 8 to 12 years. Pain scores and anteroposterior and lateral radiographs of the femoral component from the 2-year follow-up visit were evaluated. Twenty-four of the 100 hips were revised for aseptic loosening. Radiographic criteria were highly effective in predicting those cases that would require revision. Radiolucent lines occurred at a higher frequency in all Gruen zones of the revision group radiographs, and the differences were statistically significant in zones 1, 7, 8, and 14 (P < .001). Proximal radiolucent lines were present in all of the revision cases and in 45% of the nonrevision cases. Radiolucent lines occurring on the lateral view alone were a statistically significant predictor of future need for revision (P < .001). Presence of radiolucent lines around the porous coating was 100% sensitive and 55% specific in predicting future revision. Absence of radiolucent lines around the porous coating was 100% sensitive and 45% specific in predicting no need for revision in the first 8 years.  相似文献   

4.
We analyzed the progression of radiolucent lines around the acetabular cup after 452 Charnley low-friction arthroplasties that had been performed in 392 patients between 1971 and 1976. The average duration of follow-up was twenty years (range, eleven to twenty-five years) for the 442 hips (382 patients) that had the original component in place at ten years. The demarcation of the bone-cement interface was classified according to the system of Hodgkinson et al. We sought to determine if there was a relationship between the progression of the radiolucent line and the age, gender, and weight of the patient; the level of activity; the preoperative diagnosis; or the amount of wear of the acetabular cup. The demarcation increased over time in 138 (31 per cent) of the 452 hips. Radiographs made at the time of the latest follow-up showed migration of eleven (5 per cent) of the 233 acetabular cups with no demarcation on the initial postoperative radiograph, eighteen (11 per cent) of the 167 cups with type-1 demarcation, twelve (35 per cent) of the thirty-four cups with type-2 demarcation, and thirteen of the eighteen cups with type-3 demarcation. Preoperative acetabular protrusion, inflammatory arthritis, and severe acetabular dysplasia as well as a previous operation were associated with the extent of the radiolucent line on the most recent radiograph (p < or = 0.05 for all). A high level of activity and more than two millimeters of wear of the acetabular cup also were related to the progression of the radiolucent line (p = 0.0004 and p < 0.0001, respectively). Kaplan-Meier survivorship analysis demonstrated that the greater the demarcation on the initial postoperative radiograph, the greater the risk of migration (p < 0.0001, Mantel-Cox test). Our data suggest that, after a Charnley low-friction arthroplasty, any cemented cup, even one with the least amount of demarcation (types 0 and 1), can migrate. As the type of the initial postoperative demarcation increases, so does the risk of migration of the cup, particularly when there is loss of the acetabular bone stock.  相似文献   

5.
Fifty-seven revision total hip arthroplasties in fifty-six patients were performed with a Harris-Galante porous-coated acetabular component by one surgeon, and the patients were followed prospectively for a mean of seven years (range, five to twelve years). A trochanteric osteotomy was performed in forty hips, and a posterior approach with an extended anterior capsulectomy was used in the other seventeen. The acetabular defect was classified as segmental in seven hips, cavitary in twenty-three, and combined in twenty-one; six hips had no notable defect. A bulk allograft was used in eleven hips, and morseled cancellous-bone allograft or autogenous graft was used in thirty-four hips; twelve hips did not have bone-grafting. Both the femoral and the acetabular component were revised in forty-five hips, and only the acetabular component was revised in twelve. Thirty-nine hips (68 per cent) had a good or excellent clinical result according to the Harris hip score. The acetabular component was well fixed in the fourteen hips that had a fair result and the four hips that had a poor result. The acetabular component was considered to have migrated if there was a change in the angle of the cup of 5 degrees or more or a change in the horizontal or vertical position of the cup of more than three millimeters. Despite varying degrees of bone loss, no acetabular component had radiographic evidence of loosening at the latest follow-up examination. No component was revised and no revisions were scheduled. One hip was debrided for a late metastatic infection, but the component was well fixed and was not revised. There were no complications related to the use of screws for fixation. These mid-term results confirm the early success of acetabular revisions performed with fixation of a titanium fiber-metal-coated hemispherical component with multiple screws and no cement.  相似文献   

6.
The results of 136 consecutive primary total hip arthroplasties performed by one surgeon with the Harris-Galante-I porous-coated acetabular component were reviewed at a mean of seven years (range, five to ten years). In all hips, the outer diameter of the acetabular component was the same as the diameter of the final reamer used in the preparation of the acetabulum. However, this reamer was used only briefly at the rim of the acetabulum, and therefore the components had so-called press-fit stability. A mean of four screws (range, three to six screws) were used for additional fixation of the component. The clinical evaluation was performed with use of the Harris hip score. Standardized anteroposterior radiographs of the pelvis were assessed for migration of the component, radiolucent and radiodense lines, linear wear of the polyethylene, and osteolysis. No acetabular component had been revised for loosening and none were radiographically loose at the time of the most recent follow-up evaluation. There were no complications related to the use of the screws, and no screw had bent or broken. A non-progressive radiolucent line was seen in one acetabular zone in thirty-four hips (25 per cent) and in two acetabular zones in six hips (4 per cent). No hip had a radiolucent line in all three acetabular zones. The mean rate of linear wear of the polyethylene was 0.1 millimeter per year. There was no dissociation of the acetabular liner from the metal shell. Two hips (1 per cent) had asymptomatic osteolysis in the ischium and adjacent to the rim of the acetabular component; this was treated with grafting at the site of the lesion and exchange of the femoral head and the worn polyethylene liner. Five femoral components inserted without cement and one inserted with cement were revised because of loosening. The data suggest that, at a mean of seven years, fixation of this porous-coated component was uniformly excellent. The low prevalence of radiolucent lines and the absence of loosening are probably related, in part, to the technique of implantation. The low prevalence of polyethylene wear and pelvic osteolysis is a notable improvement compared with the results of arthroplasty with other porous-coated acetabular components. Although the results of the present study are encouraging, longer follow-up is necessary to determine the prevalence of late loosening and osteolysis.  相似文献   

7.
We reviewed the results of 212 total hip arthroplasties performed without cement in 203 unselected, consecutive patients who were sixty-five years of age or older. The outcome was known for 196 hips, thirty-seven of which had been followed until the death of the patient and 159 of which had been followed for a minimum of five years. A reoperation was done in 4 percent (seven) of the 196 hips. These reoperations included one revision because of loosening of the stem and five revisions of the cup. Three of the acetabular revisions were done because of fracture due to polyethylene wear; one, because of recurrent dislocation; and one, because of polyethylene wear and a fracture due to lysis. In the seventh reoperation, a cup and stem were exchanged because of infection. The probability that a hip prosthesis would survive twelve years without a reoperation was 0.92 (95 percent confidence interval, 0.85 to 0.99). We evaluated the clinical results for 152 patients who had not had a reoperation and had been followed for at least five years (mean, 8.5 years; range, five to fourteen years). Of these patients, thirteen (9 percent) had pain that limited activity: five (3 percent) had pain in the thigh (four patients) or groin (one patient), and eight (5 percent) had trochanteric pain and tenderness. One hundred and forty-four (95 percent) of the patients noted an improvement in overall function, and 149 (98 percent) reported satisfaction with the outcome. One hundred and thirty-five hips that were not revised were followed radiographically for at least five years (mean, 8.2 years; range, five to fourteen years). In this group, osteolysis was observed in three hips (2 percent); loosening of the cup, in three (2 percent); and loosening of the stem, in one (1 percent). Stress-shielding was seen on the two-year postoperative radiographs of forty-five (26 percent) of the 174 hips that were followed for at least that duration. The prevalence of osteolysis, loosening of a component, and reoperations was no greater in this subgroup than in the overall group. These results indicate that total hip arthroplasty without cement can be successful in older patients. This study also provides a reference for comparison with the results of total hip arthroplasty performed with cement and those of so-called hybrid total hip arthroplasty (an acetabular component fixed without cement and a femoral component fixed with cement) in patients who are sixty-five years of age or older.  相似文献   

8.
The senior authors' initial experience with primary hybrid hip replacement in patients with osteoarthritis was studied to evaluate the efficacy of the procedure. Hybrid total hip arthroplasty (uncemented Harris-Galante acetabular component and cemented Iowa precoated femoral component) was performed in 131 consecutive, nonselected hips in 118 patients with the diagnosis of primary osteoarthritis. Followup was performed at 8 to 9 years after the procedure. The average age at the time of the procedure was 68 years (range, 45-87 years). There were 50 men (55 hips) and 68 women (76 hips). At final followup 19 patients (22 hips) had died. The femoral component had been revised for aseptic loosening in 8 hips (6.1%). One additional hip showed definite radiographic loosening. Hence, the prevalence of radiographic femoral failure was 6.9% (9 hips). No acetabular component had been revised for aseptic loosening and no acetabular component had migrated. The senior author continues to perform hybrid total hip arthroplasty in all patients with primary osteoarthritis. However, design modifications have been made in the femoral component that is used.  相似文献   

9.
A review of 174 hips in 154 patients younger than 50 years of age who underwent primary total hip arthroplasty with a cementless acetabular component and an extensively coated femoral component done by one surgeon was performed to determine whether this method of fixation improves the results of previously reported comparable series using different methods of fixation. The average age was 37.6 years. The average followup was 8.3 years (range, 2-13 years). Eighty-eight hips had at least 10 years followup. Sixteen (9%) hips had severe stress shielding. There were 13 (7.5%) acetabular failures. Of 144 porous coated cups, three were revised for wear and one for dislocation. Another was revised 11 years postoperatively for late loosening secondary to catastrophic acetabular lysis. Excluding the bipolar and threaded components (30 hips), five (3.4%) porous coated cups were revised for failure. Of the 174 fully coated stems, 99.4% had stable fixation, 167 (96%) were ingrown, six (3.4%) had stable fibrous fixation, and one (0.6%) was unstable. Two (1.1%) femoral stems were revised. The total rate of osteolysis was 4%. Cementless extensively porous coated stems and porous coated acetabuli give excellent lasting results in young patients.  相似文献   

10.
We report the outcome of 177 consecutive primary Charnley total hip arthroplasties inserted with Boneloc cement between November 1991 and November 1993. There were 107 women and 70 men. The mean age at the time of the operation was 71 years. 11 patients (13 hips) died during the follow-up period and 3 patients were too weak to attend a follow-up examination. Of the 161 remaining hips, 4 had been revised because of deep infection. The mean follow-up time for the remaining 157 hips was 2 (0.5-3) years. 24 hips had been revised and 6 are waiting for revision because of stem loosening. Of the remaining 127 hips, 72 showed radiographic signs of stem loosening and 2 hips were probably loose. Osteolysis was seen around the femoral component in 56 hips.  相似文献   

11.
One hundred twelve consecutive primary total hip replacements were performed for osteoarthritis or osteonecrosis by a single surgeon using the Mittelmeier ceramic prosthesis without cement between January 1983 and July 1984. Ninety-three of these hips were followed prospectively to a minimum of 60 months and a median of 108 months. Five (5.4%) hips have been revised for loosening. Of the remaining hips, 77 (87.5%) were rated clinically satisfactory. Cumulative survival probability using revision as endpoint was estimated to be 92.7% at 5 years and 87.9% at 10 years. However, overall mechanical failure rates were 21.5% for the cup and 22.6% for the stem. There was no case of either femoral or acetabular osteolysis observed.  相似文献   

12.
The clinical and radiographic results of primary cemented total hip arthroplasty performed by a single surgeon, with particular emphasis on the performance of acetabular components implanted with so-called second-generation cement techniques, were studied. Seventy hips with 48 metal-backed and 22 polyethylene acetabular components were followed for a mean of 9 years (range, 5-11.5 years). The clinical results were evaluated using a recognized hip score. The fixation status of the cemented acetabular component was evaluated using two methods of measuring radiolucent lines at 5 years and at the last evaluation. Acetabular component loosening was defined as a circumferential radiolucent line, component migration, or revision for loosening. This study was unable to confirm the findings of others that demonstrated higher failure rates with cemented metal-backed components when compared with all-polyethylene components. The survival of cemented acetabular components with 28-mm head femoral prostheses was worse than the survival of cemented acetabular components with 22-mm femoral heads in other published reports, despite advances in cement techniques. Because of the high rate of loosening of cemented 28-mm-inner-diameter acetabular components at 5 and 10 years, the authors no longer use these cemented components for acetabular reconstruction.  相似文献   

13.
Thirty-five patients with bilateral osteonecrosis of the femoral head after bone marrow transplantation were reviewed retrospectively. The median age at the time of transplantation was 26 years. The first symptoms occurred within 2 years of transplantation. At presentation, 18 of the patients reported pain in both hips, 17 had symmetric radiographic lesions, and 39 of the hips had collapsed. Medical treatment was indicated initially. At the final examination before surgery (median, 3.5 years), 31 patients had bilateral hip pain, 22 patients had symmetric radiographic lesions, and 56 of the hips had collapsed. Fifty-seven of the hips required surgery, including one open drainage, four core decompressions, six cup arthroplasties, and 46 primary total hip replacements. Six hips (four core decompressions; two cups) later underwent total hip replacement revision, and a deep infection developed in one. By considering the requirement of a total hip replacement as a failure of conservative treatment, the rate of survival of the femoral head was 30% 5 years after the transplant. There was no significant difference between the Ficat grades, except for Grade 0, which showed a higher survival rate. The study of the specific features of the osteonecrosis may lead to the recommendation of primary total hip arthroplasty after failure of the medical treatment.  相似文献   

14.
One hundred and thirty-three patients (152 hips) who were an average of thirty-nine years old (range, sixteen to forty-nine years old) received a proximally hydroxyapatite-coated femoral prosthesis as part of a total hip arthroplasty and were followed for a minimum of five years (average, 6.4 years; range, five to 8.3 years) or until revision. The average Harris hip score was 47 points (range, 22 to 77 points) preoperatively and 93 points (range, 49 to 100 points) at the time of the latest clinical evaluation. Two patients who had a well fixed femoral implant had activity-limiting pain in the thigh at the time of the most recent examination. Radiographic changes consistent with bone-remodeling (cortical hypertrophy and bone condensation) typically were seen around the mid-part of the shaft of the prosthesis. Forty-eight (32 per cent) of the 148 hips that were included in the radiographic analysis demonstrated a small amount of erosive scalloping in either zone 1 or zone 7 of Gruen et al., and intramedullary osteolysis was suspected in only one hip. All stems were radiographically osseointegrated according to a modification of the criteria described by Engh et al. Four stems were revised, but none of the revisions were performed because of mechanical failure (two stems were revised in conjunction with a revision of the cup because of pain; one, because of an infection; and one, after a traumatic femoral fracture that occurred six years postoperatively). Thus, the rates of aseptic and mechanical failure were both 0 per cent. The combined rate of failure, which included the two stems that were revised because of pain and the two stems that were associated with pain that limited activity, was 2.6 per cent (four of 152 stems). The over-all clinical results associated with hydroxyapatite-coated femoral components were excellent in this group of young patients after intermediate-term follow-up. A review of serial radiographs showed mechanically stable implants with osseous ingrowth, evidence of stress transmission at the middle part of the stem, and minimum endosteal osteolysis.  相似文献   

15.
Total hip arthroplasty in patients younger than 51 years of age remains controversial. The authors report results in 47 hips in 40 patients at an average followup of 15 years. Second generation femoral cementing techniques were used. Special attention was given to studying the differences between the outcome of acetabular versus femoral fixation. The patient group included 11 in whom custom components were used and 13 who had structural autografts for severe acetabular dysplasia. One femoral component and 10 acetabular components were revised for aseptic loosening. After 15 years, improved cementing techniques produced a marked reduction in the rate of femoral aseptic loosening. Loss of fixation of cemented acetabular components was common.  相似文献   

16.
From 1969 through 1980, 90 hips in 82 patients had cemented total hip arthroplasty for Type III developmental hip dysplasia. Seventy hips were reviewed at an average of 16.6 years (range, 5-23 years) after operation. Aseptic loosening developed in 53% of acetabular cups and 40% of femoral stems. Despite attempts to place acetabular components in the anatomic center, 18 cups (25.7%) were placed outside that area. Using a measurement method to determine the true acetabular region and approximate femoral head center, final acetabular loosening strongly correlated with initial cup placement. Loosening occurred in 15 of 18 cups (83.3%) initially positioned outside of the true acetabular region compared with loosening in 22 of 52 cups (42.3%) initially positioned within the true acetabular region. Acetabular loosening also correlated with initial lateral displacement or initial superior displacement of the hip center from the approximate femoral head center. Initial cup placement medial to the approximate femoral head center was predictive of successful long term acetabular component fixation. The method of acetabular reconstruction did not affect eventual cup loosening. Placement of the hip arthroplasty center of rotation in or near the true acetabular region is recommended.  相似文献   

17.
An innovative treatment is described for unstable total hip arthroplasty that uses a large inside diameter acetabular cup and a bipolar femoral head sized to approximate the diameter of the normal hip. Eight consecutive patients with recurrent prosthetic dislocations were treated with this tripolar hip. Joint stability was achieved in all patients, who have an average of 4.2-years' followup (range, 2.6-6.3 years).  相似文献   

18.
The results of isolated acetabular revision performed in 31 patients (32 hips) were monitored for between 3 and 9 years. All femoral components were well fixed and not removed or revised at the time of index surgery. There were 4 hips with little or no acetabular bony defect, 2 hips with pure segmental defects (type I), 10 hips with cavitary defects (type II), 15 with combined segmental cavitary defects (type III), and I with pelvic discontinuity (type IV). All revision acetabular implants were cementless, using a porous-coated hemispheric cup with or without bone-graft. There were four grade I reconstructions, 16 grade II reconstructions, and 12 grade III reconstructions. At final follow-up evaluation 94% of the cups were judged to be stable. Two hips required a second revision acetabuloplasty because of loss of fixation of the cup. The 2 repeat revisions were also done without removal of the femoral component. One acetabular component had evidence of rotational migration, which stabilized and remained nonprogressive. There were no cases of femoral component radiographic or clinical failure. The mean pre and postoperative hip scores were 44 and 83, respectively. The pre- and postoperative pain scores were 12 and 42, respectively. The findings of this study suggest that isolated acetabular revision, using a cementless porous-coated hemispheric cup, can be successfully performed without removing or revising a well-fixed femoral stem and not compromise the final outcome.  相似文献   

19.
This article reports the results of 41 hips in 36 patients who underwent bipolar hemiarthroplasty for primary osteoarthritis of the hip. Surgical technique included a complete capsulectomy and light reaming of the acetabulum in all patients. The average follow-up was 8.9 years with a minimum of 8 years. Harris hip scores improved from 49 preoperatively to 93 at the latest follow-up, with 95% of the hips rated as excellent or good. Two patients had mild, intermittent groin pain, while a third developed recalcitrant pain necessitating revision. Migration of the bipolar cup was minimal with an average of 2.3 mm superior and 2.1 mm medial migration. Survivorship analysis demonstrated an 89.5% survival rate at 10 years.  相似文献   

20.
This is a retrospective clinical evaluation of 1028 primary hip arthroplasties performed with the non-cemented Harris-Galante I acetabulaer cup. Hospital records regarding all hips operated from July 1985 through March 1992 were evaluated after a median of 48 (12-93) months. Furthermore, questionnaires were sent out to all patients still alive in order to establish the actual function of the hips. At time of evaluation, 43 of the 1028 primary acetabular cups (4.2%) had been or were due to be revised. (20 because of one or more episodes of dislocation or displacement of the cup, 10 due to deep infection, eight following aseptic loosening of the cup, two because of implant failure and three due to other reasons). Four hundred and twenty-six hips were without pain, 274 had only mild or slight pain, whereas 84 experienced moderate or worse pain. We conclude, that the results after non-cemented hemispheric acetabular arthroplasties in this study are satisfying with a low rate of aseptic loosening.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号