首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A rectangular slit micro-aerodynamic-lens (μADL) aerosol concentrator operating at atmospheric pressure has been developed. A single stage version has shown concentration ratios of up to 40:1 for 1 μm aerosol particles while particles larger than 2 μm can be concentrated by more than 100:1 in a single stage. The design of this device has been guided by unsteady 3D CFD modeling using detached eddy simulations (DES), and has been validated experimentally using polystyrene spheres and salt crystals of known aerodynamic diameters. The pressure drop in the device does not exceed 1.5 kPa in the major flow and 0.3 kPa in the minor flow at a total flow of 10 slpm.

Copyright 2014 American Association for Aerosol Research  相似文献   


2.
Aerosol sampling and identification is vital for the assessment and control of particulate matter pollution, airborne pathogens, allergens, and toxins and their effect on air quality, human health, and climate change. In situ analysis of chemical and biological airborne components of aerosols on a conventional filter is challenging due to dilute samples in a large collection region. We present the design and evaluation of a micro-well (µ-well) aerosol collector for the assessment of airborne particulate matter (PM) in the 0.5–3 µm size range. The design minimizes particle collection areas allowing for in situ optical analysis and provides an increased limit of detection for liquid-based assays due to the high concentrations of analytes in the elution/analysis volume. The design of the collector is guided by computational fluid dynamics (CFD) modeling; it combines an aerodynamic concentrator inlet that focuses the aspirated aerosol into a narrow beam and a µ-well collector that limits the particle collection area to the µ-well volume. The optimization of the collector geometry and the operational conditions result in high concentrations of collected PM in the submillimeter region inside the µ-well. Collection efficiency experiments are performed in the aerosol chamber using fluorescent polystyrene microspheres to determine the performance of the collector as a function of particle size and sampling flow rate. The collector has the maximum collection efficiency of about 75% for 1 µm particles for the flow rate of 1 slpm. Particles bigger than 1 µm have lower collection efficiencies because of particle bounce and particle loss in the aerodynamic focusing inlet. Collected samples can be eluted from the device using standard pipettes, with an elution volume of 10–20 µL. The transparent collection substrate and the distinct collection region, independent of particle size, allows for in situ optical analysis of the collected PM.

© 2017 American Association for Aerosol Research  相似文献   


3.
Data are presented for the first use of novel DNA-barcoded aerosol test particles that have been developed to track the fate of airborne contaminants in populated environments. Until DNATrax (DNA Tagged Reagents for Aerosol eXperiments) particles were developed, there was no way to rapidly validate air transport models with realistic particles in the respirable range of 1–10 μm in diameter. The DNATrax particles, developed at Lawrence Livermore National Laboratory (LLNL) and tested with the assistance of the Pentagon Force Protection Agency, are the first safe and effective materials for aerosol transport studies that are identified by DNA molecules. The use of unique synthetic DNA barcodes overcomes the challenges of discerning the test material from pre-existing environmental or background contaminants (either naturally occurring or previously released). The DNATrax particle properties are demonstrated to have appropriate size range (approximately 1–4.5 μm in diameter) to accurately simulate bacterial spore transport. Here, we describe details of the first field test of the DNATrax aerosol test particles in a large indoor facility.

Copyright © 2016 American Association for Aerosol Research  相似文献   


4.
In the present work, the centrifugal filter proposed by the authors was applied to classify aerosol particles followed by the detection of total mass or number concentrations so as to measure the size distribution of aerosol particles. The structure and operating condition of the centrifugal filter were optimized in order to attain sharp separation curves with various cut-off sizes between 0.3 and 10 μm. The aerosol penetrating the centrifugal filter at various rotation speeds was measured with a photometer to determine the total mass concentration. The virtue of this system is that the cut-off size is varied just by scanning the rotation speed of filter and that it can be applied to the measurement of high concentration aerosols without dilution by choosing an appropriate filter medium. As a result, the centrifugal filter was successfully applied to measure the size distribution of solid particles in size ranging from 0.3 to 10 μm.

Copyright © 2017 American Association for Aerosol Research  相似文献   


5.
Biological particles are rarely individual organisms, but are clusters of organisms physically bound to one another, or bound to other material present in the environment. The size and composition of these bioclusters contribute to the protection of the organisms within the core of cluster from the harmful effects of ambient UV light. The use of ultraviolet irradiation has been evaluated in the past as an option for decontaminating surfaces and air; however, previous studies were conducted with single spores, or poorly characterized polydispersed aerosols making comparisons between studies difficult. This study is intended to evaluate the effect of UV-C irradiation on monodispersed particles of spore clusters with mean diameters of 2.8 μm and 4.4 μm, and single spores of Bacillus atrophaeus var. globigii on fixed surfaces and as aerosol. The D90, the UV-C irradiation doses at which 90% of the colony forming units were rendered nonculturable, for single spores and spore clusters of 2.8 and 4.4 μm on surfaces were 138, 725, and 1128 J/m2, respectively. The respective values for airborne spores were 27, 42, and 86–94 J/m2. The first-stage decay rate constant for the surface exposure ranged from 0.012 for single spores to 0.003 for 4.4 μm clusters. Similarly, the aerosol decay rate constant ranged from 0.12 for single spores to 0.04 for 4.4 μm clusters. The results of this study demonstrate that the decay rate of spores contained in clusters is proportional to the overall particle size, and that it is harder to inactivate large clusters on surfaces.

Copyright 2014 American Association for Aerosol Research  相似文献   


6.
The silicon carbide (SiC) ceramic filter is the most favorable component to remove particulate matter from hot flue gas due to its high filtration efficiency and high thermal durability. The effect of SiC powder size on the physical properties and filtration performance to prepare high-performance granular ceramic filter media was investigated in this study. Disk-type filter media were prepared by mixing ceramic components followed by physical compression and sintering. The porosity and average pore diameter in the filter media increased with increasing powder size. However, the mechanical strength decreased with increasing powder size, while it increased with increasing physical compressive force. The filter performance factor, qFM was introduced to evaluate the ceramic filter properties, and the SiC50 filter was the best of the ceramic filters prepared in this study. We also found that diffusion was a dominant collection mechanism for particles smaller than 0.7 μm, and direct interception and inertia were dominant collection mechanisms for particles larger than 0.7 μm in the SiC50 filter based on a single collector efficiency model. In addition, the predicted collection efficiencies showed reasonably good agreement with the experimental ones.

Copyright 2014 American Association for Aerosol Research  相似文献   


7.
A new primary standard method for calibrating optical particle counters (OPC) has been developed based on quantitative gravitational deposition on a silicon wafer and accurate counting of the particles by a wafer surface scanner (WSS). The test aerosol consists of 3-μm diameter monodisperse polystyrene latex (PSL) spheres at concentrations in the range of 0.1 cm?3 to 1 cm?3. A key element to the calibration is the ability to generate monodisperse PSL spheres without residue particles by use of a virtual impactor and differential mobility analyzer. The use of these devices reduced the percentage of residue particles from more than 99.98% to about 5%. The expanded relative uncertainty (95% confidence level) in the number concentration determined with a WSS for a deposition of 200 particles is 17.8%. The major uncertainty component arises from the Poisson fluctuations in the aerosol concentration because of the low concentration. This methodology has advantages of a fast scanning time by the WSS of minutes compared to hours or days by microscopy and of counting every particle deposited compared to often only a small fraction via microscopy.

The WSS was used in the calibration of an OPC based on 12 depositions with concentrations ranging from 0.1 cm?3 to 1 cm?3 for each deposition. Make-up air was added to the aerosol entering the OPC so that the lowest achievable concentration for the OPC measurement is about 0.01 cm?3 in this study. The detection efficiency of the OPC was measured to be 0.984 with an expanded uncertainty of 13.4%.

Copyright 2014 American Association for Aerosol Research  相似文献   


8.
Aerodynamic particle sizer (APS) users typically calibrate the particle sizing capabilities, but not the counting efficiency upon which aerosol concentration results are based. Herein, comparisons were made between the counts provided by an ink jet aerosol generator (IJAG) with those measured by an APS. Near-monodisperse (geometric standard deviation of about 1.06) liquid or solid aerosols in the size range of 0.95 to 13.3 μm aerodynamic diameter (AD) generated with an IJAG were released into the inner inlet-tube of the APS in a manner that rendered APS wall and aspiration losses negligible. For most experiments, the IJAG generated 75 particles/s, which rate was maintained by the IJAG system through control of electrical pulses applied to its ink jet cartridge. For particles in the size range of 2–13.3 μm AD, the ratio of relative detection efficiency (ratio of the number of particles counted by the APS to the number reported as generated by the IJAG) was 99.3 ± 1.4%; however, for test particles between 0.95 and 2 μm AD, the relative detection efficiency was somewhat lower, but the drop off was less than about 2%. This slight drop off is likely associated with the light scattering detection approach and corresponding counting algorithm of the APS. Tests were conducted where the IJAG produced 7.0 μm AD particles at rates of 1 to 500 s-1 and the results showed essentially a 1:1 correspondence between IJAG and APS counts. The presence of smaller-sized background particles did not affect the measured APS counts of larger-sized challenge particles.

Copyright 2014 American Association for Aerosol Research  相似文献   


9.
Results of a numerical study of the RespiCon sampler performance in the calm air are presented. The air flow is described by the Navier–Stokes equations of axisymmetric stationary viscous flow of incompressible fluid that are numerically integrated by the computational fluid dynamics (CFD) software FLUENT. The collection efficiencies of RespiCon impactor stages agree quite well with experimental data and curves of the European standards for the thoracic and respirable dust fractions. The aspiration efficiencies derived from the numerical model overestimate the experimental data in the range of particle sizes of 10 μm < dp < 40 μm; however, they correctly predict the value of maximal size of aspirated particles. A new design of the RespiCon sampler with a higher volume flow rate was developed.

Copyright 2014 American Association for Aerosol Research  相似文献   


10.
Cavity ring-down spectroscopy (CRDS) of single, optically manipulated aerosol particles affords quantitative retrieval of refractive indices for particles of fixed or evolving composition with high precision. Here, we quantify the accuracy with which refractive index determinations can be made by CRDS for single particles confined within the core of a Bessel laser beam and how that accuracy is degraded as the particle size is progressively reduced from the coarse mode (>1 μm radius) to the accumulation mode (<500 nm radius) regime. We apply generalized Lorenz–Mie theory to the intra-cavity standing wave to explore the effect of particle absorption on the distribution of extinction cross section determinations resulting from stochastic particle motion in the Bessel beam trap. The analysis provides an assessment of the accuracy with which the real, n, and imaginary, κ, components of the refractive index can be determined for a single aerosol particle.

Published with license by American Association for Aerosol Research  相似文献   


11.
Dust aerosol and ice crystals are two major types of nonspherical particles in the atmosphere which have significant roles in cloud-aerosol interactions and the radiative budget. The presence of dust and ice often coincide in the atmosphere because dust particles are efficient ice nuclei. The size and composition dependence of the scattering properties of dust and ice are needed to assess their individual contributions to the optical scattering of sunlight. Here we present a new measurement technique used to determine the single particle forward scattering, backscattering, and depolarization ratio (at a wavelength of 680 nm) for representative nonspherical atmospheric particles. The Texas A&M University Continuous Flow Diffusion Chamber (CFDC) was used as an ice crystal generator to produce ice crystals via both homogenous and heterogeneous nucleation mechanisms under well-controlled laboratory conditions. Optical scattering properties of mineral dusts and small ice crystals (0.6 μm to 50 μm optical diameter) were measured by the Droplet Measurement Technologies, Inc. (DMT) Cloud Aerosol Spectrometer with Polarization (CASPOL). Significant differences between the optical properties of single dusts and ice particles of the same size were observed. Differences between the optical signatures of homogeneously and heterogeneously nucleated ice crystals were not statistically significant. Our results suggest that atmospheric ice crystals can be identified and quantified independently from the dust particles on which they form based on analysis of their backscatter and depolarization signals.

Copyright 2014 American Association for Aerosol Research  相似文献   


12.
A new aerodynamic lens system for an online aerosol time-of-flight mass spectrometer (ATOFMS) has been designed and constructed to transmit and allow the analysis of individual particles in the 4–10-μm-size range. Modeling was used to help design the lens within the bounds of ATOFMS instrumental constraints. The aerodynamic lens operates at a high inlet pressure, 3066 Pa (23 Torr), with a unique tapered relaxation region to improve large particle transmission. Every stage of the lens was tested empirically using a combination of particle deposition and light scattering experiments. The critical orifice was found to significantly impact large particle transmission, with orifices <200 μm in diameter completely suppressing large particle transmission. The addition of a virtual impactor allowed for the use of large orifices without any loss of functionality in the ATOFMS. The detection efficiency of the ATOFMS was >10% for particles from 4–10 μm with a peak efficiency of 74 ± 9% for 6-μm particles. With the extended size range provided by this inlet, the ATOFMS can now be extended to investigate single cell metabolomics.

Copyright 2014 American Association for Aerosol Research  相似文献   


13.
A new sampling approach has been developed to enable affordable, time-resolved monitoring of particulate chemical composition, and more generally to provide concentrated samples of airborne particles. Using a newly developed, moderated water-based condensational growth technology, individual particle samples are deposited in a 1-mm diameter dry “spot.” The moderated condensation technology enables this collection with minimal temperature rise, providing robust collection for volatile constituents. Measured collection efficiencies are above 95% for particles in the size range from 0.010 μm to 2.5 μm. A set of 20 or more time-resolved samples, plus blanks, may be collected onto a multiwell collection plate. For chemical analysis the plate is returned to the laboratory, and placed directly into a modified autosampler, without extraction or preparation. The autosampler handles the addition of eluent, extraction, and sample injection without user manipulation. This article presents the design and laboratory evaluation of a 1.5 L/min sampling rate version of this system.

Copyright 2014 American Association for Aerosol Research  相似文献   


14.
To assess indoor bioaerosols, a virtual impactor having 1 µm cutoff diameter was designed, fabricated, and evaluated with computational fluid dynamics simulation and also with laboratory test using polystyrene latex particles. Two other cutoff diameters of 635 nm and 1.5 µm were obtained by changing the inlet flow rate and the ratio of minor channel-to-inlet flow rates. In field test, the virtual impactor was operated with varying cutoff diameter and field-emission scanning electron microscope (FE-SEM) analysis was performed for each cutoff diameter to observe morphologies of indoor aerosol particles sampled at the major and minor outlet channels. Particles were sampled at both outlet channels using the SKC Button Aerosol sampler and subsequently cultured. By colony counting, it was found that 56% of cultured fungal particles and 63% of cultured bacterial particles had aerodynamic sizes smaller than 1 µm. MALDI-TOF analysis and visual inspection of culture samples were used to identify indoor bacterial and fungal species, respectively. Nearly same species of bacteria and fungi were detected both in the major and minor flow channels.

© 2017 American Association for Aerosol Research  相似文献   


15.
A three-dimensional stochastic model is developed for predicting atmospheric aerosol collection and aggregation on the surface of a falling raindrop at its terminal velocity. Potential flow and viscous flow are assumed as the flow fields in the vicinity of the large and the small raindrops, respectively. The results show that hydrophobic coarse mode aerosols collected by either small raindrops (dc < 100 μm) or large drops (dc > 100 μm) form aggregations on the surfaces of drops, and accumulation mode aerosols tend to be captured by the aggregations or hydrophobic coarse particles which have been collected by the drops, and this may significantly enhance the capability of the raindrop for fine aerosol collection. When the aggregation effect is considered in the calculation, fine aerosol efficiency can be promoted by one to two orders of magnitude. Therefore, fine particle collision efficiency by raindrops is underestimated by employing the classical dynamic theory which neglects the particle aggregation effect. However, the collection efficiency of coarse particles remains almost constant with the increase in the amount of particles collected by large drops, while there is only a slight increase in efficiency by small raindrops upon increasing in particle concentration. This implies that the traditional limiting trajectory method can still be used for the calculation of coarse particle collection efficiencies by either small or large raindrops.

Copyright © 2018 American Association for Aerosol Research  相似文献   


16.
The aerodynamic lens system of the Aerodyne Aerosol Mass Spectrometer (AMS) was analyzed using the Aerodynamic Lens Calculator. Using this tool, key loss mechanisms were identified, and a new lens design that can extend the transmission of particulate matter up to 2.5 μm in diameter (PM2.5) was proposed. The new lens was fabricated and experimentally characterized. Test results indicate that this modification to the AMS lens can significantly improve the transmission of large sized particles, successfully achieving a high transmission efficiency up to PM2.5 range.

© 2016 American Association for Aerosol Research  相似文献   


17.
A novel instrument has been developed for generating highly monodisperse aerosol particles with a geometrical standard deviation of 1.05 or less. This aerosol generator applies a periodic mechanical excitation to a micro-liquid jet obtained by aerodynamic flow-focusing. The jet diameter and its fastest growth wavelength have been optimized as a function of the flow-focusing pressure drop and the liquid flow rate. The monodisperse aerosol generated by this instrument is also charge neutralized with bipolar ions produced by a non-radioactive, corona discharge device. Monodisperse droplet generation in the 15- to 72-μm diameter range from a single 100-micron nozzle has been demonstrated. Both liquid and solid monodisperse particles can be generated from 0.7- to 15-μm diameter by varying solution concentration, liquid flow rate, and excitation frequency. The calculated monodisperse particle diameter agrees well with independent measurements. The operation of this new monodisperse aerosol generator is stable and reliable without nozzle clogging, typical of other aerosol generators at the lower end of the operating particle size ranges.

Copyright © 2016 American Association for Aerosol Research  相似文献   


18.
Prevention of airborne contagious diseases depends on successful characterization of aerosols in the environment. The use of cascade impactors to characterize ambient aerosols is one of the most commonly used methods, providing data on both particle size and concentration. In this study, the use of a cascade impactor recently described in the literature using 8 mL of liquid in Petri dishes (CI-L) was compared with a new method that uses wet membrane filters on top of wax filled Petri dishes (CI-WWMF). Sampling efficiencies of the cascade impactors were evaluated using 0.5, 1, 3, and 5 μm polystyrene latex (PSL) microspheres and aerosol consisting of single spores of Bacillus atrophaeus var. globigii (BG). The sampling efficiency of the CI-L was 6%, 11%, 17%, 21%, and 58% for 0.5, 1, 3, 5 μm PSL microspheres and BG spores, respectively. Higher overall sampling efficiencies of 71%, 91%, 60%, 64%, and 104% were observed for the same size and type of particles for the CI-WWMF. This study indicates that using wet filters on top of wax-filled Petri dishes (CI-WWMF) in a viable cascade impactor is more efficient than the CI-L method for size-selectively collecting biological aerosols from the environment. The CI-WWMF method is useful when a liquid medium is required for identifying and quantifying organisms using polymerase chain reaction (PCR) and immuno-assay techniques.

Copyright © 2017 American Association for Aerosol Research  相似文献   


19.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


20.
The use of inlets for transferring aerosols from the environment to instrumentation can introduce uncertainty in the measurement of aerosol properties. Aerosol loss during this process is a non-negligible issue that may bias the subsequent measurements. These loss mechanisms include aspiration at the inlet head and deposition/evaporation/condensation during transport through the sampling lines. Coarse-mode aerosol is significantly impacted by the aspiration and inertial loss mechanisms within an inlet system. This work uses wind tunnel experiments to investigate aerosol losses through the Storm Peak Laboratory’s (SPL) new aerosol inlet system. The inlet is used extensively for both intensive field campaigns and long-term aerosol monitoring. The results of numerical simulations of the SPL aerosol inlet sampling efficiency are provided at several wind speeds, and experimental results demonstrate the system has a 50% cut off for the coarse-mode at an aerodynamic diameter of approximately 13?μm and wind speed of 0.5?m s?1. This investigation will lead to improved accuracy of in situ aerosol measurements at SPL and this system can be replicated at other atmospheric stations.

Copyright © 2019 American Association for Aerosol Research  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号