首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We have developed a new, fully controlled filter testing device and have used it to measure size-resolved penetration through a typically used filtration media for (but not only) atmospheric aerosol sampling. Twenty membrane and fiber filter pieces (mixed cellulose ester filters, polytetrafluoroethylene filters, quartz fiber filters, glass fiber filters, and polycarbonate filters) of various manufacturers and filter codes were examined. High variability in the penetration curve shapes, most penetrating particle size (MPPS) (from 20 nm to 90 nm) and penetration maxima (from 0.001% to almost 100%) has been found. The dependence of pressure drop on face velocity generally agrees with theory, the comparison of penetration at various face velocities proved the theoretical equations being able to determine MPPS only partially correctly. Although the variability within an individual filter of the same code is not negligible, it is small compared to the differences between the various filter types. The results not only differed from the information provided by the manufacturers, but in many cases also provided information otherwise unavailable, although affecting the sampling and also the ability of comparison with theory. To have enough information for the proper choice of the filter for a given purpose, it would be necessary to have not only total penetration given from the DOP standard measurement, but the MPPS, penetration maximum value and pressure drop as well.

Copyright 2015 American Association for Aerosol Research  相似文献   

2.
The flat surface of Nuclepore filters is suitable for observing collected particles with a scanning electron microscope (SEM). However, experimental data on surface-collection efficiency are limited because surface-collection efficiencies cannot be measured directly using aerosol measuring instruments. In this study, the surface-collection efficiencies of Nuclepore filters were determined by establishing the ratio of the number of particles deposited on the surface of the filter visually counted with an SEM to the number of inflow particles counted by a condensation particle counter, using monodispersed polystyrene latex particles (30–800 nm) and silver particles (15–30 nm). Because Nuclepore filters with smaller pore sizes would be expected to produce higher minimum surface-collection efficiency and a higher pressure-drop, 0.08 and 0.2 µm Nuclepore filters were chosen as the test filters in view of both collection efficiency and pressure drop. The results showed that the minimum surface-collection efficiencies of the 0.08 µm pores at face velocities of 1.9 and 8.4 cm·s?1 were approximately 0.6 and 0.7, respectively, and those of the 0.2 µm pores at face velocities of 1.5 and 8.6 cm·s?1 were approximately 0.8 and 0.6, respectively. Because the pressure drop of the 0.2 µm pore filter was lower than that of the 0.08 µm pore filter under the same flow-rate conditions, the 0.2 µm pore filter would be more suitable considering the pressure drop and collection efficiency. The obtained surface collection efficiencies were quantitatively inconsistent with theoretical surface-collection efficiencies calculated using conventional theoretical models developed to determine the collection efficiency of filters with larger pores.

© 2016 American Association for Aerosol Research  相似文献   

3.
Composite films of Cu and multiwalled carbon nanotubes (MWCNTs) were fabricated by an electrodeposition technique, and their field emission properties were examined. Commercially available MWCNTs with various diameters (60–150 nm) were used. The microstructure of the composite films was analyzed by scanning electron microscopy and the field emission properties were measured using a diode-type system. Cu/MWCNT composite films with homogeneous dispersion of MWCNTs were fabricated using each type of MWCNT. Bare MWCNTs were present on the surface of the composite films and the ends of the protruding tips were fixed by the deposited copper matrix. The composite films produced clear emission currents and the corresponding Fowler–Nordheim (F–N) plots showed that these were field emission currents. The turn-on electric field tended to decrease with decreasing MWCNT diameter. A light-emitting device incorporating the Cu/MWCNT composite film as a field emitter was fabricated, and its light-emitting properties were investigated. Light emission with a brightness of around 100 cd m?2 was observed for approximately 100 h.  相似文献   

4.
Pleated electret HVAC filters are often used in residence to mitigate the particles that originate both indoors and outdoors. These filters are usually tested with particles larger than 300 nm. However, residential particles can contain a significant amount of nanoparticles with size below 50 nm due to cooking, smoking, cleaning, wood burning, and outdoor infiltration. In order to characterize the nanoparticle removal by electret HVAC filters, penetrations of 3–50 nm silver nanoparticles through five different flat sheet electret media used in commercial residential HVAC filters were tested with face velocities of 0.05, 0.5, and 1.0 m s–1. Experimental results showed that all media had significantly high penetrations with 0.35–0.8 at the most penetrating particle sizes (MPPSs) for all three velocities, which were in the sizes of 10–30 nm. A model based on single fiber theory for particle penetration predictions was used and compared with the experimental data. Results showed that the model predicted the nanoparticle penetrations very well for all media and all face velocities tested. According to the model, for enhancing the nanoparticle efficiency of the current commercial HVAC filters, the fiber diameter should be reduced or the number of pleats should be increased. However, by doing these, pressure drop and cost may be largely increased. On the other hand, this study found the existing commercial mechanical HVAC filters were much capable for sub–50 nm nanoparticle removal when their minimum efficiency reporting values (MERVs) were larger than 13 and it is concluded mechanical HVAC filters can do a better job than electret ones. However, the quality factor analysis showed electret filters could be regarded as the best filter media for removing particles smaller than 300 nm.

Copyright 2015 American Association for Aerosol Research  相似文献   

5.
The surface and overall collection efficiencies of capillary pore membrane filters were measured for sub-micrometer particles. Collection efficiencies were derived from the surface loadings of particles on filters measured by scanning electron microscopy and from airborne particle concentrations measured with a scanning mobility particle sizer. Tests used filters with nominal pore diameters of 0.4 and 0.8 μm and face velocities of 3.7 and 18.4 cm/s. Surface collection efficiencies were below 100% for particles smaller than 316 nm and below 55% for particles smaller than 100 nm. Overall collection efficiencies reached as low as 45% for 70 nm particles. For nanoparticles, collection efficiencies overall were substantially higher than those to the filter surface, indicating that deposition occurs to a large extent inside the filter pores. These results underscore the need to account for surface collection efficiency when deriving airborne concentrations from microscopic analysis of nanoparticles on capillary pore membrane filters.  相似文献   

6.

This study investigated the effect of using a stainless steel fibrous filter as the ground electrode of a point-to-plate electrostatic precipitator on particle penetration. The effect of the electrical field on particle penetration was investigated at 4 different filter face velocities (25, 50, 100, and 125 cm/s) for monodisperse PSL and silica particles (size range 0.05-1 m) as well as polydis perse ammonium sulfate, ammonium nitrate, and ultrafine indoor air particles. Particle penetration was greatly reduced by the application of the electrical field. By comparison, the performance of electrically active fibrous filters has been shown to rapidly degrade as particle loading exceeds 2-3 g/m2. The effect of particle loading on particle penetration was also investigated at a filter face velocity of 50 cm/s. Particle penetration seemed to slightly decrease with particle loading and was independent of particle size. These results indicated that the accumulation of nonconductive particles up to 15 cm3/ m2 does not create ''back corona,'' which would substantially decrease the collection efficiency of the grounded filter. In conclusion, our experiments suggest that using metal filters as the collector electrodes may be an attractive alternative design for electrostatic precipitators.  相似文献   

7.
Filtration efficiency of multi-walled carbon nanotube (MWCNT) aerosol by fibrous filter was evaluated experimentally. Mono-mobility test aerosols with electrical mobility diameter of 100, 200, and 300 nm were generated by the atomization of MWCNT aqueous suspension followed by mobility classification with a differential mobility analyzer (DMA). By analyzing the shape of classified aerosol particles under a scanning electron microscope, it was found that the DMA-classified 300 nm particles were fibrous in shape and had uniform diameter of about 60 nm and length of 2.1 micrometer. On the other hand, 100 nm and 200 nm particles contained a fairly large amount of multiply charged fibrous particles with a larger diameter. These test aerosols were challenged to a medium performance fibrous filter at various filtration velocities. As a result, fibrous particles were captured by fibrous filter at a higher collection efficiency than the spherical particles with the same mobility. By analyzing the single fiber capturing efficiency, interception incorporating the rotation of fibrous particles is found to be the dominant capturing mechanism for the fibrous particles in the studied size range.  相似文献   

8.
Aerosol collection efficiency was studied for electrostatically charged fibrous filters (3M Filtrete?, BMF-20F). In this study, collection efficiencies at moderate filter face velocities (0.5–2.5 m/s) representative of some high volume sampling applications was characterized. Experimental data and analytical theories of filter performance are less common in this flow regime since the viscous flow field assumption may not be representative of actual flow through the filter mat. Additionally, electrostatic fiber charge density is difficult to quantify, and measurements of aerosol collection efficiency are often used to calculate this fundamental parameter. The purpose of this study was to assess the relative influence of diffusion, inertial impaction, interception, and electrostatic filtration on overall filter performance. The effects of fiber charge density were quantified by comparing efficiency data for charged and uncharged filter media, where an isopropanol bath was used to eliminate electrostatic charge. The effects of particle charge were also quantified by test aerosols brought into the equilibrium Boltzmann charge distribution, and then using an electrostatic precipitator to separate out only those test particles with a charge of zero. Electrostatically charged filter media had collection efficiencies as high as 70–85% at 30 nm. Filter performance was reduced significantly (40–50% collection efficiency) when the electrostatic filtration component was eliminated. Experiments performed with zero charged NaCl particles showed that a significant increase in filter performance is attributable to an induction effect, where electrostatic fiber charge polarizes aerosol particles without charge. As filter face velocity increased the electrostatic filtration efficiency decreased since aerosol particles had less time to drift toward electrostatically charged fibers. Finally, experimental data at 0.5 m/s were compared to theoretical predictions and good agreement was found for both electrostatic and nonelectrostatic effects.

© 2013 American Association for Aerosol Research  相似文献   

9.
The performance of electrostatically charged blown microfiber filter media was characterized for high-volume sampling applications. Pressure drop and aerosol collection efficiency were measured at air pressures of 55.2 and 88.7 kilopascals (kPa) and filter face velocities ranging from 2.5 to 11.25 meters per second (m/s). Particle penetration was significant for particles above 0.5 micrometers (μm) in aerodynamic diameter where the onset of particle rebound was observed as low as 200 nanometers (nm). Particle retention was enhanced by treating filters in an aqueous solution of glycerol. Adding this retention agent eliminated electrostatic capture mechanisms but mitigated inertial rebound. Untreated filters had higher nanoparticle collection efficiencies at lower filter face velocities where electrostatic capture was still significant. At higher filter face velocities, nanoparticle collection efficiencies were higher for treated filters where inertial capture was dominant and particle rebound was mitigated. Significant improvements to microparticle collection efficiency were observed for treated filters at all air flow conditions. At high air pressure, filter efficiency was greater than 95% for particles less than 5 μm. At low air pressure, performance enhancements were not as significant since air velocities were significantly higher through the fiber mat. Measured single fiber efficiencies were normalized by the theoretical single fiber efficiency to calculate adhesion probability. The small fiber diameter (1.77 μm) of this particular filter gave large Stokes numbers and interception parameters forcing the single fiber efficiency to its maximum theoretical value. The adhesion probability was plotted as a function of the ratio of Stokes and interception parameter similar to the works of others. Single fiber efficiencies for inertial nanoparticle collection were compared to existing theories and correlations.

Copyright 2014 American Association for Aerosol Research  相似文献   


10.
《分离科学与技术》2012,47(3):477-491
Abstract

This investigation experimentally studied the penetration curve of particles that impact on a sintered stainless‐steel filter with various pore sizes, sampling flow rates and jet diameters. The penetration curves were compared to those with an aluminum foil substrate. Test data reveal that when the sintered stainless‐steel filter has larger pore sizes (100 µm or 40 µm), the particle penetration, P(%), is lower and the curve is less steep than that obtained from the aluminum foil substrate. The penetration curve of the sintered stainless‐steel filter with smaller pore size (5 µm) is close to that of the aluminum foil substrate. The dimensionless cutsize‐shift (the ratio of the dimensionless cutsize of sintered stainless‐steel filter to that of aluminum foil) falls as the pore sizes and the Reynolds number increase. Experimental data were then compared with theoretical results, and theory over‐predicted the dimensionless cutsize‐shift. Hence, a regression equation for the dimensionless cutsize‐shift is proposed by fitting the experimental data. The discrepancy between the experimental data and the regression prediction is within 4%. The regression equation can be used to predict the dimensionless cutsize for the size‐fractionated measurements of particles that impact on a sintered stainless‐steel filter with various sized pores and Reynolds numbers.  相似文献   

11.
A new polar nephelometer (PN) has been developed to measure simultaneously the scattering angular distributions from 11.7° to 168.3° for individual particles in planes parallel and perpendicular to the polarization of the incident laser beam. Each detection plane had 21 silicon photodiode detectors to detect scattered light at a rate of 100 Hz. Laboratory experiments to validate the performance of the instrument were conducted using nearly mono-disperse spherical particles (polystyrene latex [PSL] and nigrosine) and nonspherical particles (sodium chloride [NaCl] and soot). The observed scattering angular distributions for individual PSL particles were in good agreement with the results of simulations based on Mie theory. Complex refractive index values for nigrosine particles were determined by comparing the observed scattering angular distributions with the results of simulations. Clear differences between the measured scattering angular distributions and the results of simulations based on Mie theory assuming spherical particles were observed for NaCl particles (mobility diameters of 500 and 700 nm) and propane soot particles (mobility diameters of 300, 500, and 700 nm). These results are reasonably explained by theoretical predictions. We also conducted initial observations of ambient particles in Nagoya city, Japan. Scattering angular distributions for particles with a mobility diameter of 500 nm and an average effective density of 1.4 or 0.3 g/cm3, which were selected with a combination of differential mobility analyzer and aerosol mass particle analyzer, were measured using the PN. As results, scattering angular distributions for nearly spherical inorganic and organic particles with an average effective density of around 1.4 g/cm3 were found to be distinguishable from nonspherical particles with an average effective density of around 0.3 g/cm3. This study has demonstrated that our PN has the potential to distinguish between spherical and nonspherical particles.

Copyright © 2016 American Association for Aerosol Research  相似文献   


12.
The fractional penetration of submicrometer particles through five high-efficiency glass fiber filters, one composite fiber filter, and two membrane filters was measured for particles of 0.004–0.42-μm diameter at filter face velocities ranging from 0.5 to 20 cm/s. The glass fiber filters all had approximately the same thickness and weight per unit area, and were rated 93% to 99.999% efficient using the conventional 0.3-μm dioctyl phthalate (DOP) test. The challenge aerosols were electrically classified monodisperse DOP in the diameter range of 0.032–0.42 μm, and polydisperse silver condensation aerosols having diameters of ~ 0.004–0.01 μm. Aerosol penetration through these media was found to be generally consistent with current theory for collection by diffusion and interception over the particle size and velocity range studied. Using a filter figure of merit calculated for penetration by 0.1- and 0.3-μm particles to facilitate comparison, all of the filters except one tetrafluoroethylene membrane filter (which was slightly better) had about the same performance.  相似文献   

13.
Polyacrylonitrile (PAN) fibers with mean diameters in 270-400 nm range were prepared by electrospinning for use as a filter media. Compared to commercial filters made of polyolefin and glass, the fibers of electrospun filters were more uniform in diameter. The performance of electrospun filters was evaluated by measuring the penetration of monodisperse NaCl nanoparticles (below 80 nm in size) through the filters. It was found that electrospun filters could be made which had nanoparticle penetration values comparable to commercial filters but with substantially less filter mass. The penetration of nanoparticles through the electrospun filter media could be reduced by increasing the filter thickness, which is controlled by the collection time during the electrospinning process. Nanoparticle collection by electrostatic forces was found to be negligible for electrospun filters. Filter quality factors and single fiber collection efficiencies were found to be independent of filter thickness for electrospun filters, and the penetration of nanoparticles through electrospun filters was in better agreement with theoretical predictions than was the measured penetration through a commercial filter. This study shows that electrospinning is a promising technology for the production of high performance nanoparticle filters.  相似文献   

14.
Most filtration models assume that the air stream runs perpendicularly to the orientation of the filter fibers. However, cigarette filters remove aerosol particles apparently by a different filter configuration in that the fiber orientation almost parallels the air streamlines. To focus on the effect of fiber orientation, cellulose acetate filters were used in this work to facilitate the filter performance comparison. A piece of original round cigarette filter was molded to form a cube. The same piece of filter was used for both perpendicular and parallel orientations, to avoid the variability caused by the non-uniform filter media distribution. DOP aerosol particles used in the tests were generated by either a constant output aerosol nebulizer or an ultrasonic atomizing nozzle. A Po-210 radiation source was used to neutralize the challenge aerosols to the Boltzmann charge equilibrium. A scanning mobility particle sizer (for < 0.8 μm) and an aerodynamic particle sizer (for > 0.8 μm) were used to measure aerosol number concentrations and size distributions upstream and downstream of the cigarette filters. The results showed that parallel and orthogonal filters behave similarly. However, the pressure drop across parallel filter was lower than for the perpendicular filter, indicating that the airflow is more laminar passing through the parallel filters. Possibly for the same reason, aerosol penetration through parallel filter was higher than the orthogonal filter, although the difference may not be statistically significant. When a comparison of the fiber orientation is based on filter quality, orthogonal filter performs better than parallel filter, if face velocity is lower than 60 cm/s. Parallel filter performs better only when the particles are smaller than the most penetrating size and under high face velocity.  相似文献   

15.
Vapor phase growth of gold, nickel and titanium metal nanoparticles on multiwall carbon nanotube (MWCNT) buckypaper by sputtering was investigated. The size and distribution of nanoparticles was dependent on the intrinsic binding energy of the metal elements, but could be altered to mimic that of metals with different binding energies by in situ modification of the MWCNT surfaces by energetic metal ions or annealing of the buckypaper. A range of average gold particle diameters from approximately 5–30 nm could be produced depending on the intrinsic sputter process parameters (especially metal ion flux and kinetic energy) and defect density of the MWCNT surfaces, which could also be controlled by annealing prior to sputtering. The diameter of the MWCNTs had a significant influence on the geometry of the nanoparticles. Particles were elongated along the nanotube axis for tube diameters <30 nm. Remarkably strong alignment of the particles along the nanotube axis was observed, especially for MWCNTs with higher defect densities.  相似文献   

16.
By combination of a differential mobility analyzer (DMA) with a filter with uniform pores, namely a filter sensor, a new method for differentiating nanoparticles with various mass-mobility fractal dimensions, Dfm, was developed and validated experimentally and theoretically. The sensor is also able to measure the effective length (or maximum projected length) of nanoparticles with different shapes, which is an important parameter responsible for the lung deposition due to interception. At the same mobility diameter, it was observed that the compact NaCl had the highest penetration followed by partially sintered silver (Ag) aggregates and then the loose Ag and soot agglomerates. The result indicates that the stronger interception by the filter is correlated to the more elongated shape of the particles. A modified capillary tube model for predicting the penetration of Ag nanoparticles with different mass-mobility fractal dimensions was validated by experimental data. By using the validated model, this study found that the sensor could have a further enhanced sensitivity if the porosity and thickness of the filter were adjusted to 0.01 and 5 µm, respectively. The penetration differences obtained from the model are as high as 7–18%, 14–35%, and 24–40% between spheres and loose agglomerates (Dfm = 2.1) for 50–100, 100–300, and 300–1000 nm particles as the filter pore sizes are 0.4, 1, and 3 µm, respectively. This new filter sensor can measure the effective length and mass-mobility fractal dimension in nearly real-time and may be applied in nanotoxicity studies and quality control of nanomaterial productions (e.g., by flame reactors).

Copyright 2015 American Association for Aerosol Research  相似文献   

17.
Understanding the filtration characteristics of fibrous particles is important since those particles have caused health and environmental concerns. Due to the straight morphology of metal nanowires, unlike carbon nanotube (CNT) particles nanowires can be considered as appropriate test material to evaluate existing filtration theory for cylindrical particles. We measured the penetration of silver nanowires in the size range of dm = 200 to 400 nm through screen mesh filter. By using Li et al. (2012)'s theory, we determined the orientation status of silver nanowires inside differential mobility analyzer (DMA) and calculated the dynamic shape factor of nanowires. Theoretical penetration was obtained by using single fiber theory with modified interception parameter including orientation angle between a filter wire and a particle. The orientation angle obtained by fitting experimental data into single fiber theory for the 1 layer of screen mesh filter is found to be close to 40° indicating random orientation of nanowires near filter. However, in the experiments with multi-layers of screen mesh, any tendency related to the orientation angle was not found. We performed numerical simulations for the filtration processes such as impaction, diffusion, interception, and interception of diffusing particles by introducing modified slip correction factor. Overall, when interception of diffusing particles is considered in addition to diffusion and interception, numerically simulation results and theoretical prediction agree better with experimental data regarding the penetration of silver nanowires through the 1 layer of screen mesh filter.

Copyright 2014 American Association for Aerosol Research  相似文献   


18.
Recent studies suggest that inhaled or intratracheally instilled multi-walled carbon nanotubes (MWCNTs) cause adverse health effects depending on the fiber length. In the present study a simple batch particle generation system was developed to generate airborne MWCNTs for inhalational toxicology studies. The generation rate can be controlled by the amplitude of sieve shaker. Maximum concentration of respirable airborne MWCNTs was 1.2 mg m–3 at a nose-exposure chamber supplied with air at flow rate of 30 L min–1. We examined the performance of airborne MWCNT generation system and characterized properties of generated fibrous particles at mass concentrations of 0.4 mg m–3 (particle number; ca. 1700 cm–3). Monomodal shaped size distributions with peak located at electrical mobility diameter of 300 nm (in number) and aerodynamic diameter of 1–2 μm (in mass) were measured with a scanning mobility particle sizer and with a low-pressure impactor, respectively. Two hour particle generation reproducibility tests were conducted five times, in which stability and repeatability of particle size and total number concentration were within an acceptable range. Aerodynamically classified particle morphology was studied by TEM, dissociated fiber-like and agglomerated MWCNT particles were observed. The former contributes up to 38% to counted particles, and the average width and length of fiber were 80 nm and 3.7 μm, respectively, with an aerodynamic size for particle of 260–381 nm.  相似文献   

19.
The use of graphene layer encapsulated catalytic metal particles for the growth of narrower multi-walled carbon nanotubes (MWCNTs) has been studied using plasma-enhanced chemical vapor deposition and conventional thermal CVD. Ni–C or Fe–C composite nanoclusters were fabricated using the dc arc discharge technique with metal–graphite composite electrodes carrying a current of 100–200 A in a stainless-steel chamber filled with He and CH4 mixture gas at 27 kPa. Nano-sized grains with diameters less than 10 nm were fabricated and deposited on a Si substrate, and were used as a catalyst for MWCNT growth. Structural analyses of the composite nanoclusters and MWCNTs were carried out using transmission electron microscopy. The results show that the diameters of the MWCNTs were reduced from 50–100 nm for a conventional Ni thin film-evaporated Si substrate to a minimum of roughly 2–4 nm in the present study.  相似文献   

20.
The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min?1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号