首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


2.
The objective of the present study was to characterize the performance of a federal reference method (FRM) PM10 size-selective inlet using analysis methods designed to minimize uncertainty in measured sampling efficiencies for large particles such as those most often emitted from agricultural operations. The performance of an FRM PM10 inlet was characterized in a wind tunnel at a wind speed of 8 km/h. Data were also collected for 20 and 25 μm particles at wind speeds of 2 and 24 km/h. Results of the present sampler evaluation compared well with those of previous studies for a similar inlet near the cutpoint, and the sampler passed the criteria required for certification as a FRM sampler when tested at 8 km/h. Sampling effectiveness values for particles with nominal diameters of 20 and 25 μm exceeded 3% for 8 and 24 km/h wind speeds in the present study and were statistically higher than both the “ideal” PM10 sampler (as defined in 40 CFR 53) and the ISO (1995) standard definition of thoracic particles (p < 0.05) for 25 μm particles leading to the potential for significant sampling bias relative to the “ideal” PM10 sampler when measuring large aerosols.

Copyright 2014 American Association for Aerosol Research  相似文献   


3.
The characteristics of fugitive dust emitted from vehicles traveling on unpaved dirt roads were measured using a suite of instruments including a real-time fugitive dust sampler. The fugitive dust sampler is formed from a combination of a large particle inlet and an optical particle spectrometer that reports particle sizes from 6 to 75 µm. The large particle inlet permits the sampling of particles up to 75 µm with only a moderate dependence of sampling efficiency on wind-speed. Measurements made with the sampler showed that particles as large as ~50 µm were suspended from vehicular movement on the dirt roads, with the mode of the fugitive dust particle number size distribution ~2 µm, while the mass distribution mode was ~7 µm. A comparison of the fugitive dust sampler measurements with those made using standard PM instruments showed that the conventional instruments have a wind-direction bias that can result in under-sampling of large particles. The current measurements suggest that particles suspended from dirt roadways are of importance for local air quality within the near-road environment.

Copyright © 2017 American Association for Aerosol Research  相似文献   


4.
Objectives: The aim of this in vitro study was to evaluate the effect of different desensitizers’ application on the microleakage of previously restored Class V composite resin restorations.

Materials and methods: Class V cavities were prepared on the buccal surfaces of 40 extracted human third molars. Forty box-shaped cavities were divided into four groups, based on the desensitizers used (n = 10). All teeth were restored with the same bonding agent and composite material. No desensitizer was applied in the control group. In the experimental groups, BisBlock, Gluma and Universal bonding agents were the desensitizers. The desensitizers were applied after completion of composite restorations according to manufacturers’ instructions. All specimens were then thermocycled at 5–55 °C, with a 10-s dwell time for 500 cycles. The samples were then immersed in 0.5% methylene blue dye for 24 h, sectioned into two equal halves, evaluated for microleakage using a stereomicroscope at 30× magnification and scored on a scale of 0–3. The data were analysed using the Kruskal–Wallis test at the significance level p < 0.05.

Results: There were no significant differences in microleakage after desensitizer application (p > 0.05). However, based on the obtained numerical values in our study, while the BisBlock and bonding groups showed lower microleakage at the occlusal margin, BisBlock, Gluma and bonding group showed lower microleakage at the gingival margin compared to the control group.

Conclusions: The application of desensitizers as a post-treatment option could be considered an advisable procedure to minimize microleakage.  相似文献   


5.
Detection and quantification of dilute viral aerosols, as encountered outside animal housing facilities, requires methods that are able to detect small numbers of viruses in large volumes of air. This study compared the performance of two size-differentiating cascade impactors; an Andersen 8-stage (ACI; 28.3 L/min) and a high volume Tisch (TCI; 1,133 L/min) to assess sampling efficiency for detecting porcine reproductive and respiratory syndrome virus (PRRSV) and influenza A virus (IAV). Samples of particles sorted by aerodynamic diameter were analyzed by quantitative polymerase chain reaction (qPCR) and collection efficiency was assessed by particle size. Collection media (minimum essential medium [MEM] and beef extract [BE]), elution technique (active versus passive), and sampling times (10, 20, and 30 min) were variables assessed for the TCI sampler. Extraction efficiency was 35% higher with BE as compared to that of MEM (p = 0.0007); active extraction technique was 19% more efficient than the passive technique (p = 0.03); time of sampling did not significantly affect the amount of virus recovered. The ACI sampler was more efficient in detecting both viruses from small and medium sized airborne particles (≤3 μm) as compared to the TCI sampler (p < 0.001). The latter sampler, however, was more efficient at IAV detection from large airborne particles (>3 μm) (p = 0.0025) indicating the potential of this sampler in detecting the presence of small amounts of viruses in aerosols under field conditions.

© 2017 American Association for Aerosol Research  相似文献   


6.
Aerosol sampling and identification is vital for assessment and control of particulate matter pollution, airborne pathogens, allergens and toxins, and their effect on air quality, human health, and climate change. Assays capable of accurate identification and quantification of chemical and biological airborne components of aerosol provide very limited sampling time resolution and relatively dilute samples. A low-cost micro-channel collector (μCC) which offers fine temporal and spatial resolution, high collection efficiency, and delivers highly concentrated samples in very small liquid volumes was developed and tested. The design and optimization of this μCC was guided by computational fluid dynamics (CFD) modeling. Collection efficiency tests of the sampler were performed in a well-mixed aerosol chamber using aerosolized fluorescent microspheres in the 0.5–6 μm diameter range. Samples were collected in the μCC and eluted into 100 μL liquid aliquots; bulk fluorescence measurements were used to determine the performance of the collector. Typical collection efficiencies were above 50% for 0.5 μm particles and 90% for particles larger than 1 μm. The experimental results agreed with the CFD modeling for particles larger than 2 μm, but smaller particles were captured more efficiently than predicted by the CFD modeling. Nondimensional analysis of capture efficiencies showed good agreement for a specific geometry but suggested that the effect of channel curvature needs to be further investigated.

Copyright 2014 American Association for Aerosol Research  相似文献   


7.
8.
A rectangular slit micro-aerodynamic-lens (μADL) aerosol concentrator operating at atmospheric pressure has been developed. A single stage version has shown concentration ratios of up to 40:1 for 1 μm aerosol particles while particles larger than 2 μm can be concentrated by more than 100:1 in a single stage. The design of this device has been guided by unsteady 3D CFD modeling using detached eddy simulations (DES), and has been validated experimentally using polystyrene spheres and salt crystals of known aerodynamic diameters. The pressure drop in the device does not exceed 1.5 kPa in the major flow and 0.3 kPa in the minor flow at a total flow of 10 slpm.

Copyright 2014 American Association for Aerosol Research  相似文献   


9.
Objective: This study investigated the bond strength of two resin cements (Panavia F 2.0 and Multilink N) to different CAD/CAM materials: resin nanoceramic (RNC; Lava Ultimate), hybrid ceramic (HC; Vita Enamic), zirconia-reinforced lithium silicate ceramic (ZLDC; Vita Suprinity), and lithium disilicate glass-ceramic (LDG; IPS e.max CAD HT).

Material and methods: CAD/CAM blocks of 2-mm thickness were sectioned with a slow-speed diamond-saw sectioning machine. The slabs were then embedded in autopolymerizing acrylic resin (n = 12), and resin cements were applied to the surface of the specimens. All specimens were stored in water for 24 h and subjected to 5000 thermal cycles. Bond strength was measured by means of the shear bond strength test. The data were statistically analyzed by two-way ANOVA and Tukey LSD post hoc tests.

Results: The results of the two-way ANOVA test indicated that the bond strength values varied significantly depending on the CAD/CAM restorative materials, resin cements, and interaction of these variables (p < 0.05). The RNC group showed the highest bond strength for Panavia F 2.0 (p < 0.05); there were no significant differences among other CAD/CAM materials for Panavia F 2.0 (p > 0.05). The LDG group showed the highest bond strength for Multilink N, it was followed by the ZLDC group (p < 0.05); there were no significant differences between RNC and HC groups (p > 0.05).

Conclusions: Choosing resin cements for restorations should be done carefully because bond strength values vary significantly depending on the resin cement and CAD/CAM restorative material.  相似文献   


10.
Objective: The aim of the present study was to assess the influence of an in vitro aging regime (NaOCl storage) on dentine microtensile bond strength (μTBS) of five one-step one-bottle self-etch adhesives in comparison with bond strength of two-step self-etch adhesive.

Material and methods: Flattened dentine surfaces from 30 bovine incisors were bonded with five one-step one-bottle self-etch adhesives (iBond, Clearfil S3 Bond, AdheSE One F, G-Bond, Optibond all-in-one) and one two-step self-etching adhesive (Clearfil SE Bond). Composite buildups were done with microhybrid resin composite. Bonded samples were sectioned into resin–dentine sticks of 0.8 mm2 cross section. Randomly selected 20 sticks were tested directly by microtensile bond strength testing machine, whereas another randomly selected 20 sticks were tested after being stored in solution of 10% NaOCl for 5 h. Data were analyzed by two-way analysis of variance (ANOVA) and Tukey’s honest significant difference (HSD) tests (p < 0.05).

Results: All adhesives exhibited similar dentine bond strength with exception of G-Bond. After NaOCl storage, μTBS reduced in all groups significantly. The lowest μTBS were found for G-Bond. Rest of one-step self-etch adhesives presented similar μTBS with two-step self-etch adhesive.

Conclusion: Interfaces of resin–dentine bonding are susceptible to NaOCl degradation. The amount of the destruction depends on adhesive system. NaOCl degradation of the nonresin encapsulated collagen fibers might decrease long-term stability of resin bonding with dentine.  相似文献   


11.
Objective: To evaluate the influence of manual and mechanical mixing techniques as well as the effects of moisture on the push-out bond strength of ProRoot MTA (Dentsply Tulsa Dental, Tulsa, OK, USA) and Biodentine (Septodont, Saint Maur des Fosses, France) to radicular dentin.

Material and methods: Two hundred and forty dentin discs were assigned into three groups with respect to the moisture condition tested: (1) dry, (2) paper points, (3) wet. The discs were further divided into four subgroups according to the calcium silicate cements (CSCs) and mixing techniques used: (1) ProRoot MTA mixed manually, (2) ProRoot MTA mixed mechanically, (3) Biodentine mixed manually, and (4) Biodentine mixed mechanically. Bond strengths of the cements to root canal dentin were measured using a push-out test setup. The data were statistically analyzed using three-way ANOVA and Bonferroni post hoc test p = 0.05.

Results: The data indicated that the push-out bond strength values were significantly affected by CSCs, mixing techniques, and moisture conditions (p < 0.001). Dry conditions caused a significant decrease in bond strength values for both CSCs (p < 0.001). The mean bond strength of Biodentine was significantly higher than that of ProRoot MTA, regardless of the mixing techniques and moisture conditions (p < 0.001). Mechanical mixing favored bond strength values statistically compared to manual mixing (p < .001).

Conclusion: The mixing techniques and moisture conditions have an effect on the push-out bond strengths of ProRoot MTA and Biodentine. Dry samples and manual mixing of cements deteriorate the push-out bond strengths values.  相似文献   


12.
The conventional blown process imparts an inherent haze to the product. The percentage of haze varies with certain process variables:

1. Surface irregularities caused by melt flow phenomena

2. Crystallization behavior

3. Melt drawing phenomena in certain types of polyethylene  相似文献   


13.
Objective: This study aimed to evaluate the degree of conversion (DC) of two different resin cements polymerized under the monolithic zirconia specimens in different thicknesses and colors.

Material and methods: Partially stabilized monolithic zirconia blocks (inCoris TZI) were cut into three different thicknesses (0.5, 1.0, and 2.0 mm) and the specimens were divided into four color groups (A1, A2, A3, and A4). The light transmittance of each specimen was measured. Panavia F 2.0 or Variolink N resin cement was applied into teflon mold and irradiated using the light emitting diode curing unit for 20 s under monolithic zirconia specimen (n = 10). The resin cement specimens were stored at room temperature under dry conditions. The DC of each specimen was measured by Fourier transform infrared-attenuated total reflection (FT-IR/ATR) spectroscopy after the 1st and 10th day. Data were analyzed with two-way analysis of variance (ANOVA), two-way repeated measures ANOVA, three-way repeated measures ANOVA, and the Tukey least significant difference (LSD) tests (α = 0.05).

Results: The light-cure resin cement groups showed higher DC than the dual-cure resin cement groups (p < 0.05). The DC of both resin cements reduced with an increase in the thickness and darkening of the color of monolithic zirconia specimens. There was a statistically meaningful increase in the 10th-day values for dual-cure resin cement (p < 0.05), whereas there were no significant differences between the 1st- and 10th-day values for light-cure resin cement (p > 0.05).

Conclusion: The use of light-cure resin cement can be suggested for the luting of monolithic zirconia restorations.  相似文献   


14.
Polycyclic aromatic hydrocarbons (PAHs) are relatively well-known organic pollutants and due to their carcinogenic and mutagenic properties their presence in the environment still attracts a lot of attention.

According to literature reports and own research, PAHs presence in wastewaters is common. It was confirmed that PAHs are the components of municipal landfill leachate. Membrane techniques are one of the most interesting ways of removing PAHs from leachate.

The purpose of this article is to monitor PAHs concentration changes during the membrane (reverse osmosis - RO) leachate treatment processes. In the first stage of testing leachates were filtrated on the sand bed (pre-filtration). After the pre-filtration they were directed to the membrane module for the main filtration.

Sixteen PAHs listed by EPA were analyzed. The results with information on PAHs concentration in leachate samples were presented using HPLC with fluorescence detection (FLD). The changes in PAHs concentration were determined in leachate samples before and after pre-filtration as well as after RO. The decrease of PAHs concentration in the samples was observed after these processes. The total concentration of 16 PAHs in raw municipal landfill leachates amounted to 23.64–26.95 μg/L. The research confirmed the high efficiency in removal of PAHs while using a reverse osmosis (59–72%). Including the pre-filtration, the overall level of removed PAHs reached 81–86%. The average PAHs concentration after pre-filtration and RO was in the 4.46–4.99 μg/L range. The municipal landfill leachate with a high concentration of PAHs should be cleaned before it is discharged into the environment.  相似文献   


15.
A new primary standard method for calibrating optical particle counters (OPC) has been developed based on quantitative gravitational deposition on a silicon wafer and accurate counting of the particles by a wafer surface scanner (WSS). The test aerosol consists of 3-μm diameter monodisperse polystyrene latex (PSL) spheres at concentrations in the range of 0.1 cm?3 to 1 cm?3. A key element to the calibration is the ability to generate monodisperse PSL spheres without residue particles by use of a virtual impactor and differential mobility analyzer. The use of these devices reduced the percentage of residue particles from more than 99.98% to about 5%. The expanded relative uncertainty (95% confidence level) in the number concentration determined with a WSS for a deposition of 200 particles is 17.8%. The major uncertainty component arises from the Poisson fluctuations in the aerosol concentration because of the low concentration. This methodology has advantages of a fast scanning time by the WSS of minutes compared to hours or days by microscopy and of counting every particle deposited compared to often only a small fraction via microscopy.

The WSS was used in the calibration of an OPC based on 12 depositions with concentrations ranging from 0.1 cm?3 to 1 cm?3 for each deposition. Make-up air was added to the aerosol entering the OPC so that the lowest achievable concentration for the OPC measurement is about 0.01 cm?3 in this study. The detection efficiency of the OPC was measured to be 0.984 with an expanded uncertainty of 13.4%.

Copyright 2014 American Association for Aerosol Research  相似文献   


16.
Purpose: To investigate the effects of phosphoric acid esters (PAEs)-containing primers on the micro-tensile bond strengths (MTBS) of etched enamel, the micro-morphologies of the resin–enamel interfaces, and the enamel surfaces.

Materials and Methods: Thirty-three bovine incisors were used in this study. After the labial enamel surfaces were highly polished, they were etched, water sprayed, and air-dried. Afterward, the enamel surfaces were treated with or without (control) one of three PAEs-containing primers (40%MDP, Ivoclar Vivadent; Resulcin AquaPrime A + B, DMG; Xeno V, Dentsply), water sprayed, and air-dried. Subsequently, an adhesive Heliobond (Ivoclar Vivadent) was applied and resin composite (Core Build-up, Bisco) was placed incrementally. They were prepared into multiple beams of about 1 × 1 × 8 mm for MTBS tests. The enamel surfaces and resin–enamel interfaces were analyzed by SEM and TEM. The data were analyzed by two-way ANOVA and LSD test.

Results: Using PAEs-containing primers could increase the enamel MTBS (p < 0.05). The primer MDP produced higher MTBS than the primer Resulcin AquaPrime A + B and Xeno V. The SEM findings revealed the primed enamel surfaces were covered with a thin or glue-like layer of monomer-calcium salts of PAEs and the residual enamel crystallites, and various micro-porosities were detected within the hybrid layers. The TEM findings revealed the hydroxyapatite crystallites were tightly covered by the adhesive, the adhesive mixed with resin composite, or sparse irregular enamel crystallites.

Conclusion: The application of PAEs-containing primers on the etched enamel substrate could significantly increase the immediate enamel bond strengths. However, this effect was dependent on the individual PAEs-containing primer used.  相似文献   


17.
Objectives: The aim of this study was to evaluate the effect of bioactive glass–ceramic particles (Biosilicate®) addition on surface nanoroughness and topography of Resin-modified glass ionomer cements (RMGICs).

Methods: Experimental materials were made by incorporating 2 wt% of Biosilicate® into Fuji II LC® (FL) and Vitremer® (VT) powders. Disks of RMGICs (with and without Biosilicate®) measuring 0.5 cm (diameter) × 0.5 mm (thickness) were fabricated and polished. Samples were stored at 37 °C in dry or immersed in distilled water for 30 days. Digital images (20 × 20 μm) from the surfaces were obtained by means of an atomic force microscopy. Three images were acquired for each sample, and four nanoroughness measurements were performed in each image. Nanoroughness (Ra, nm) was assessed by Nanoscope Software V7. Data were analyzed with ANOVA and Student–Newman–Keuls multiple comparisons (p < 0.05). SEM images were obtained for surface topography analysis.

Results: FL was significantly rougher than VT (p < 0.05) in wet and dry conditions. The addition of Biosilicate® increased the surface roughness in VT and decreased in FL, regardless of the storage media (p ≤ 0.05). No differences existed between materials and storage conditions after Biosilicate® addition. Significance: The Biosilicate® particles addition produced changes on the surface nanoroughness of the RMGICs. These changes depended on the particles size of the original cements in dry conditions. In water storage, dissolution of the Biosilicate® particles, a silica-rich gel formation, and a hydroxyl carbonate apatite precipitation on the surface of the materials changed the nanoroughness surface. FL was the roughest in both conditions.

Significance: The Biosilicate® particles addition produced changes on the surface nanoroughness of the RMGICs. These changes depended on the particles size of the original cements in dry conditions. In water storage, dissolution of the Biosilicate® particles, a silica-rich gel formation, and a hydroxyl carbonate apatite precipitation on the surface of the materials changed the nanoroughness surface. FL was the roughest in both conditions.  相似文献   


18.
To assess indoor bioaerosols, a virtual impactor having 1 µm cutoff diameter was designed, fabricated, and evaluated with computational fluid dynamics simulation and also with laboratory test using polystyrene latex particles. Two other cutoff diameters of 635 nm and 1.5 µm were obtained by changing the inlet flow rate and the ratio of minor channel-to-inlet flow rates. In field test, the virtual impactor was operated with varying cutoff diameter and field-emission scanning electron microscope (FE-SEM) analysis was performed for each cutoff diameter to observe morphologies of indoor aerosol particles sampled at the major and minor outlet channels. Particles were sampled at both outlet channels using the SKC Button Aerosol sampler and subsequently cultured. By colony counting, it was found that 56% of cultured fungal particles and 63% of cultured bacterial particles had aerodynamic sizes smaller than 1 µm. MALDI-TOF analysis and visual inspection of culture samples were used to identify indoor bacterial and fungal species, respectively. Nearly same species of bacteria and fungi were detected both in the major and minor flow channels.

© 2017 American Association for Aerosol Research  相似文献   


19.
The estimation of air velocity distributions and particle trajectories is inevitable to analyse the mechanism of classification, but the direct measurement of il is extremely difficult.

The authors, here report three dimensional air velocity distributions within the inside drum of model Sturtevant-type air classifier measured by a spherical five-holed Pitot-lube, and also two dimensional particle ejecting velocities on a model distributor determined by photography.

Using those results, the cut size calculated from particle trajectories in the classifier is compared with the experimental results and theoretical values.  相似文献   


20.
An extensive array of literature data on the heat transfer from a reactor wall to a fluid flowing through a packed bed and those obtained from some experimental runs were interpreted with a model containing two parameters: ke, (effective radial thermal conductivity within the bed) and hw (heat transfer coefficient at the wall).

Both parameters were considered in terms of a stagnant contribution (due to the heat conduction through the solid particles and the fluid in the void space) and a radial mixing contribution (due to the heat convection by turbulent mechanism.

The stagnant contribution was interpreted with a model similar to that proposed by Kunii and Smith (1966) for heat transfer in a packed bed with motionless fluid.

General correlating equations for calculating the stagnant and the turbulent contributions of both ke, and hw are proposed.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号