首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
X‐ray computed tomography is a strong tool that finds many applications both in medical applications and in the investigation of biological and nonbiological samples. In the clinics, X‐ray tomography is widely used for diagnostic purposes whose three‐dimensional imaging in high resolution helps physicians to obtain detailed image of investigated regions. Researchers in biological sciences and engineering use X‐ray tomography because it is a nondestructive method to assess the structure of their samples. In both medical and biological applications, visualization of soft tissues and structures requires special treatment, in which special contrast agents are used. In this detailed report, molecule‐based and nanoparticle‐based contrast agents used in biological applications to enhance the image quality were compiled and reported. Special contrast agent applications and protocols to enhance the contrast for the biological applications and works to develop nanoparticle contrast agents to enhance the contrast for targeted drug delivery and general imaging applications were also assessed and listed.  相似文献   

2.
Several dedicated commercial lab‐based micro‐computed tomography (μCT) systems exist, which provide high‐resolution images of samples, with the capability to also deliver in‐line phase contrast. X‐ray phase contrast is particularly beneficial when visualizing very small features and weakly absorbing samples. The raw measured projections will include both phase and absorption effects. Extending our previous work that addressed the optimization of experimental conditions at the commercial ZEISS Xradia 500 Versa system, single‐distance phase‐contrast imaging is demonstrated on complex biological and material samples. From data captured at this system, we demonstrate extraction of the phase signal or the correction of the mixed image for the phase shift, and show how this procedure increases the contrast and removes artefacts. These high‐quality images, measured without the use of a synchrotron X‐ray source, demonstrate that highly sensitive, micrometre‐resolution imaging of 3D volumes is widely accessible using commercially advanced laboratory devices.  相似文献   

3.
In this study, we compare two evolving techniques for obtaining high‐resolution 3D anatomical data of a mouse specimen. On the one hand, we investigate cryotome‐based planar epi‐illumination imaging (cryo‐imaging). On the other hand, we examine X‐ray phase‐contrast micro‐computed tomography (micro‐CT) using synchrotron radiation. Cryo‐imaging is a technique in which an electron multiplying charge coupled camera takes images of a cryo‐frozen specimen during the sectioning process. Subsequent image alignment and virtual stacking result in volumetric data. X‐ray phase‐contrast imaging is based on the minute refraction of X‐rays inside the specimen and features higher soft‐tissue contrast than conventional, attenuation‐based micro‐CT. To explore the potential of both techniques for studying whole mouse disease models, one mouse specimen was imaged using both techniques. Obtained data are compared visually and quantitatively, specifically with regard to the visibility of fine anatomical details. Internal structure of the mouse specimen is visible in great detail with both techniques and the study shows in particular that soft‐tissue contrast is strongly enhanced in the X‐ray phase images compared to the attenuation‐based images. This identifies phase‐contrast micro‐CT as a powerful tool for the study of small animal disease models.  相似文献   

4.
Soft X‐ray microscopy has excellent characteristics for imaging cells and subcellular structures. In this paper, the yeast strain, Candida utilis, was imaged by soft X‐ray microscopy and three‐dimensional volumes were reconstructed with the SART‐TV method. We performed segmentation on the reconstruction in three dimensions and identified several types of subcellular architecture within the specimen cells based on their linear absorption coefficient (LAC) values. Organelles can be identified by the correlation between the soft X‐ray LAC values and the subcellular architectures. Quantitative analyses of the volume ratio of organelles to whole cell in different phases were also carried out according to the three‐dimensional datasets. With such excellent features, soft X‐ray imaging has a great influence in the field of biological cellular and subcellular research.  相似文献   

5.
The architectural properties of the osteocyte cell network provide a valuable basis for understanding the mechanisms of bone remodelling, mineral homeostasis, ageing and pathologies. Recent advances in synchrotron microtomography enable unprecedented three‐dimensional imaging of both the bone lacunar network and the extracellular matrix. Here, we investigate the three‐dimensional morphological properties of osteocyte lacunae in human healthy and bisphosphonate‐related osteonecrotic jaw bone based on synchrotron X‐ray computed tomography images, with a spatial isotropic voxel size of 300 nm. Bisphosphonate‐related osteonecrosis of the jaw is a relatively new disease with increasing incidence, which remains poorly understood. A step forward in elucidating this malady is to assess whether, and how, the morphology of the osteocyte lacunar network is modified in the affected jaw tissue. We evaluate thousands of cell lacunae from five specimens of which three originate from patients diagnosed with bisphosphonate‐associated osteonecrosis. In this exploratory study, we report three‐dimensional quantitative results on lacunar volumes (296–502 μm3), shape (approximated by an ellipsoidal shape with principal axes a > b > c, such that a = 2.2b and a = 4c) and spatial distribution (i.e., 50% of the mineralized matrix volume is located within 12 μm to the closest lacunar boundary) at submicron resolution on such specimens. We observe that the average lacunar volumes of the bisphosphonate‐related osteonecrotic jaw specimens were within the range of volumes found in the two specimens originating from healthy donors and conclude that lacunar volumes are not the key element in the course of bisphosphonate‐related osteonecrotic jaw. In three out of five specimens we observe lacunar volume sizes in segmented osteons to be significantly different compared to lacunar volumes in the adjacent tissue regions. Furthermore, we quantify the number of lacunae containing small dense objects (on average 9%). In contrast to lacunar morphology we report the lacunar density (16 000–50 000 per mm3) to be different in jaw bone tissue compared to what has been reported in femoral sites.  相似文献   

6.
Three‐dimensional (3D) printing technology has the advantage of enabling specific visualization of creative ideas. Since synchrotron based images can provide high sensitivity and high resolution, they are a very useful technology to identify the 3D anatomy of microscale samples. X‐ray images using such synchrotron radiation are grafted to 3D printing technology. We can be obtained 3D images and modeling data of an ant using synchrotron radiation, and then, it were outputted with the 3D printer. A new way to identify the usefulness of the structure analysis is then found by visualizing the micro‐internal structure of diverse biomedical samples and creating an enlarged model. This study suggests methods of utilizing a 3D printed model produced through synchrotron radiation imaging in various fields such as bioengineering, medical, and education.  相似文献   

7.
The retina is one of the most tiny and sophisticated tissues of the body. Three dimensional (3D) visualization of the whole retina is valuable both in clinical and research arenas. The tissue has been predominantly assessed by time‐consuming histopathology and optical coherence tomography (OCT) in research and clinical arenas. However, none of the two methods can provide 3D imaging of the retina. The purpose of this study is to give a volumetric visualization of rat retina at submicron resolution, using an emerging imaging technique‐phase‐contrast X‐ray CT. A Sprague‐Dawley (SD) rat eye specimen was scanned with X‐ray differential phase contrast tomographic microscopy (DPC‐microCT) equipped at the Swiss Light Source synchrotron. After scanning, the specimen was subjected to routine histology procedures and severed as a reference. The morphological characteristics and signal features of the retina in the DPC‐microCT images were evaluated. The total retina and its sublayers thicknesses were measured on the DPC‐microCT images and compared with those obtained from the histological sections. The retina structures revealed by DPC‐microCT were highly consistent with the histological section. In this study, we achieved nondestructive 3D visualization of SD rat retina. In addition to detailed anatomical structures, the objective parameters provided by DPC‐microCT make it a useful tool for retinal research and disease diagnosis in the early stage.  相似文献   

8.
Nanoscopic synchrotron X‐ray imaging was performed on scalp hair samples of patients with breast cancer and healthy individuals to investigate any structural differences as diagnostic tool. Hair strands were divided into 2‐3 segments along the strands from root to tip, followed by imaging either in projection or in CT scanning with a monochromatic 6.78‐keV X‐ray using zone‐plate optics with a resolving power of 60 nm. All the examined cancer hairs exhibited medulla loss with cancer stage‐dependent pattern; complete loss, discontinuous or trace along the strands. In contrast, medullas were well retained without complete loss in the healthy hair. In the CT‐scanned axial images, the cortical spindle compartments had no contrast in the healthy hair, but appeared hypointense in contrast to the surrounding hyperintense cortical membrane complex in the cancer hair. In conclusion, observation of medulla loss and cortical membrane enhancements in the hair strands of breast cancer patients demonstrated structural variations in the cancer hair, providing a new platform for further synchrotron X‐ray imaging study of screening breast cancer patients. Microsc. Res. Tech. 79:23–30, 2016. © 2015 Wiley Periodicals, Inc.  相似文献   

9.
A thorough understanding of inner ear anatomy is important for investigators. However, investigation of the mouse inner ear is difficult due to the limitations of imaging techniques. X‐ray phase contrast tomography increases contrast 100–1,000 times compared with conventional X‐ray imaging. This study aimed to investigate inner ear anatomy in a fresh post‐mortem mouse using X‐ray phase contrast tomography and to provide a comprehensive atlas of microstructures with less tissue deformation. All experiments were performed in accordance with our institution's guidelines on the care and use of laboratory animals. A fresh mouse cadaver was scanned immediately after sacrifice using an inline phase contrast tomography system. Slice images were reconstructed using a filtered back‐projection (FBP) algorithm. Standardized axial and coronal planes were adjusted with a multi‐planar reconstruction method. Some three‐dimensional (3D) objects were reconstructed by surface rendering. The characteristic features of microstructures, including otoconia masses of the saccular and utricular maculae, superior and inferior macula cribrosae, single canal, modiolus, and osseous spiral lamina, were described in detail. Spatial positions and relationships of the vestibular structures were exhibited in 3D views. This study investigated mouse inner ear anatomy and provided a standardized presentation of microstructures. In particular, otoconia masses were visualized in their natural status without contrast for the first time. The comprehensive anatomy atlas presented in this study provides an excellent reference for morphology studies of the inner ear.  相似文献   

10.
Soft X‐ray contact microscopy (SXCM) is, at present, a useful tool for the examination at submicrometre resolution of biological systems maintained in their natural hydrated conditions. Among current X‐ray‐generating devices, laser‐plasma sources are now easily available and, owing to their pulse nature, offer the opportunity to observe living biological samples before radiation damage occurs, even if the resolution achievable is not as high as with synchrotron‐produced X‐rays. To assess the potential of laser‐plasma source SXCM in the study of cellular organelles, we applied it for the analysis of chloroplasts extracted from spinach leaves and mitochondria isolated from bovine heart and liver. X‐ray radiation was generated by a nanosecond laser‐plasma source, produced by a single shot excimer XeCl laser focused onto an yttrium target. The images obtained with SXCM were then compared with those produced by transmission electron microscopy observation of the same samples prepared with negative staining, a technique requiring no chemical fixation, in order to facilitate their interpretation and test the applicability of SXCM imaging.  相似文献   

11.
We developed cryo‐scanning x‐ray diffraction microscopy, utilizing hard x‐ray ptychography at cryogenic temperature, for the noninvasive, high‐resolution imaging of wet, extended biological samples and report its first frozen‐hydrated imaging. Utilizing phase contrast at hard x‐rays, cryo‐scanning x‐ray diffraction microscopy provides the penetration power suitable for thick samples while retaining sensitivity to minute density changes within unstained samples. It is dose‐efficient and further minimizes radiation damage by keeping the wet samples at cryogenic temperature. We demonstrate these capabilities in two dimensions by imaging unstained frozen‐hydrated budding yeast cells, achieving a spatial resolution of 85 nm with a phase sensitivity of 0.0053 radians. The current work presents the feasibility of cryo‐scanning x‐ray diffraction microscopy for quantitative, high‐resolution imaging of unmodified biological samples extending to tens of micrometres.  相似文献   

12.
This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X‐rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X‐ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low‐absorption contrast have been visualized using in‐line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X‐ray radiation with high‐photon flux (>1012 photons/s) at high‐photon energies (5–70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20‐μm thick tissue slice induces a phase shift between 1/3π and 2/3π. Microsc. Res. Tech., 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

13.
Non‐invasive imaging techniques like X‐ray computed tomography have become very popular in zoology, as they allow for simultaneous imaging of the internal and external morphology of organisms. Nevertheless, the effect of different staining approaches required for this method on samples lacking mineralized tissues, such as soft‐bodied invertebrates, remains understudied. Herein, we used synchrotron radiation‐based X‐ray micro‐computed tomography to compare the effects of commonly used contrasting approaches on onychophorans – soft‐bodied invertebrates important for studying animal evolution. Representatives of Euperipatoides rowelli were stained with osmium tetroxide (vapour or solution), ruthenium red, phosphotungstic acid, or iodine. Unstained specimens were imaged using both standard attenuation‐based and differential phase‐contrast setups to simulate analyses with museum material. Our comparative qualitative analyses of several tissue types demonstrate that osmium tetroxide provides the best overall tissue contrast in onychophorans, whereas the remaining staining agents rather favour the visualisation of specific tissues and/or structures. Quantitative analyses using signal‐to‐noise ratio measurements show that the level of image noise may vary according to the staining agent and scanning medium selected. Furthermore, box‐and‐whisker plots revealed substantial overlap in grey values among structures in all datasets, suggesting that a combination of semiautomatic and manual segmentation of structures is required for comprehensive 3D reconstructions of Onychophora, irrespective of the approach selected. Our results show that X‐ray micro‐computed tomography is a promising technique for studying onychophorans and, despite the benefits and disadvantages of different staining agents for specific tissues/structures, this method retrieves informative data that may eventually help address evolutionary questions long associated with Onychophora.  相似文献   

14.
We present in this study results from X‐ray tomographic microscopy with synchrotron radiation performed both in attenuation and phase contrast modes on a limestone sample during two stages of water drying. No contrast agent was used in order to increase the X‐ray attenuation by water. We show that only by using the phase contrast mode it is possible to achieve enough water content change resolution to investigate the drying process at the pore‐scale. We performed 3D image analysis of the time‐differential phase contrast tomogram. We show by the results of such analysis that it is possible to obtain a reliable characterization of the spatial redistribution of water in the resolved pore system in agreement with what expected from the theory of drying in porous media and from measurements performed with other approaches. We thus show the potential of X‐ray phase contrast imaging for pore‐scale investigations of reactive water transport processes which cannot be imaged by adding a contrast agent for exploiting the standard attenuation contrast imaging mode.  相似文献   

15.
In this paper, the use of lithium fluoride (LiF) as imaging radiation detector to analyse living cells by single‐shot soft X‐ray contact microscopy is presented. High resolved X‐ray images on LiF of cyanobacterium Leptolyngbya VRUC135, two unicellular microalgae of the genus Chlamydomonas and mouse macrophage cells (line RAW 264.7) have been obtained utilizing X‐ray radiation in the water window energy range from a laser plasma source. The used method is based on loading of the samples, the cell suspension, in a special holder where they are in close contact with a LiF crystal solid‐state X‐ray imaging detector. After exposure and sample removal, the images stored in LiF by the soft X‐ray contact microscopy technique are read by an optical microscope in fluorescence mode. The clear image of the mucilaginous sheath the structure of the filamentous Leptolyngbya and the visible nucleolus in the macrophage cells image, are noteworthiness results. The peculiarities of the used X‐ray radiation and of the LiF imaging detector allow obtaining images in absorption contrast revealing the internal structures of the investigated samples at high spatial resolution. Moreover, the wide dynamic range of the LiF imaging detector contributes to obtain high‐quality images. In particular, we demonstrate that this peculiar characteristic of LiF detector allows enhancing the contrast and reveal details even when they were obscured by a nonuniform stray light.  相似文献   

16.
Synchrotron‐generated X‐rays provide scientists with a multitude of investigative techniques well suited for the analysis of the composition and structure of all types of materials and specimens. Here, we describe the properties of synchrotron‐generated X‐rays and the advantages that they provide for qualitative morphological research of millimetre‐sized biological organisms and biomaterials. Case studies of the anatomy of insect heads, of whole microarthropods and of the three‐dimensional reconstruction of the cuticular tendons of jumping beetles, all performed at the beamline ID19 of the European Synchrotron Radiation Facility (ESRF), are presented to illustrate the techniques of phase‐contrast tomography available for anatomical and structural investigations. Various sample preparation techniques are described and compared and experimental settings that we have found to be particularly successful are given. On comparing the strengths and weaknesses of the technique with traditional histological thin sectioning, we conclude that synchrotron radiation microtomography has a great potential in biological microanatomy.  相似文献   

17.
High‐resolution tomographic images using synchrotron X‐rays are expected to provide detailed reflection of microstructures, thereby allowing for the examination of histologic structures without destruction of the specimen. This study aims to evaluate the synchrotron tomographic images of mixed ground‐glass opacity excised on 5‐mm sections in comparison to pathologic examination. The Institutional Review Board of our institute approved this retrospective study, and written informed consent was obtained from each patient whose lung tissue would be used. Obtained lung cancer specimens were brought to the multiple Wiggler 6C beam line at the Pohang Light Source (PLS‐II) in Korea, and phase contrast X‐ray images were obtained in November 2016. The X‐ray emanated from a bending magnet of the electron storage ring with electron energy of 3 GeV, and a typical beam current was 320 mA. Reconstructed tomographic images were compared with images from histologic slides obtained from the same samples. Pulmonary microstructures including terminal bronchioles, alveolar sacs, and vasculature were identified with phase contrast X‐ray images. Images from normal lung tissue and mixed ground‐glass opacity were clearly distinguishable. Hyperplasia of the interalveolar septum and dysplasia of microstructure were clearly identified. The imaging findings correlated well with hematoxylin‐eosin stained specimens. Tomographic images using synchrotron radiation have the potential for clinical applications. With refinement, this technique may become a diagnostic tool for detection of lung cancer.  相似文献   

18.
Previous work using focused ion beam (FIB) analysis of osteoblasts on smooth and microrough Ti surfaces showed that the average cell aspect ratio and distance from the surface are greater on the rough surface. In order to better interrogate the relationship between individual cells and their substrate using multiple imaging modalities, we developed a method that tracks the same cell across confocal laser scanning microscopy (CLSM) to correlate surface microroughness with cell morphology and cytoskeleton; scanning electron microscopy (SEM) to provide higher resolution for observation of nanoroughness as well as chemical mapping via energy dispersive X‐ray spectroscopy; and transmission electron microscopy (TEM) for high‐resolution imaging. FIB was used to prepare thin sections of the cell‐material interface for TEM, or for three‐dimensional electron tomography. Cells were cultured on laser‐sintered Ti‐6Al‐4V substrates with polished or etched surfaces. Direct cell to surface attachments were observed across surfaces, though bridging across macroscale surface features occurred on rough substrates. Our results show that surface roughness, cell cytoskeleton and gross morphology can be correlated with the cell‐material cross‐sectional interface at the single cell level across multiple high‐resolution imaging modalities. This work provides a platform method for further investigating mechanisms of the cell‐material interface.  相似文献   

19.
Vascularization is essential for many tissues and is a main requisite for various tissue‐engineering strategies. Different techniques are used for highlighting vasculature, in vivo and ex vivo, in 2‐D or 3‐D including histological staining, immunohistochemistry, radiography, angiography, microscopy, computed tomography (CT) or micro‐CT, both stand‐alone and synchrotron system. Vascularization can be studied with or without a contrast agent. This paper presents the results obtained with the latest Skyscan micro‐CT (Skyscan 1272, Bruker, Belgium) following barium sulphate injection replacing the bloodstream in comparison with results obtained with a Skyscan In Vivo 1076. Different hard and soft tissues were perfused with contrast agent and were harvested. Samples were analysed using both forms of micro‐CT, and improved results were shown using this new micro‐CT. This study highlights the vasculature using micro‐CT methods. The results obtained with the Skyscan 1272 are clearly defined compared to results obtained with Skyscan 1076. In particular, this instrument highlights the high number of small vessels, which were not seen before at lower resolution. This new micro‐CT opens broader possibilities in detection and characterization of the 3‐D vascular tree to assess vascular tissue engineering strategies.  相似文献   

20.
Electron microscopy is used in biological research to study the ultrastructure at high resolution to obtain information on specific cellular processes. Serial block face‐scanning electron microscopy is a relatively novel electron microscopy imaging technique that allows three‐dimensional characterization of the ultrastructure in both tissues and cells by measuring volumes of thousands of cubic micrometres yet at nanometre‐scale resolution. In the scanning electron microscope, repeatedly an image is acquired followed by the removal of a thin layer resin embedded biological material by either a microtome or a focused ion beam. In this way, each recorded image contains novel structural information which can be used for three‐dimensional analysis. Here, we explore focused ion beam facilitated serial block face‐scanning electron microscopy to study the endothelial cell–specific storage organelles, the Weibel–Palade bodies, during their biogenesis at the Golgi apparatus. Weibel–Palade bodies predominantly contain the coagulation protein Von Willebrand factor which is secreted by the cell upon vascular damage. Using focused ion beam facilitated serial block face‐scanning electron microscopy we show that the technique has the sensitivity to clearly reveal subcellular details like mitochondrial cristae and small vesicles with a diameter of about 50 nm. Also, we reveal numerous associations between Weibel–Palade bodies and Golgi stacks which became conceivable in large‐scale three‐dimensional data. We demonstrate that serial block face‐scanning electron microscopy is a promising tool that offers an alternative for electron tomography to study subcellular organelle interactions in the context of a complete cell.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号