首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wickens K  Lane J  Siebers R  Ingham T  Crane J 《Indoor air》2004,14(3):217-222
Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment and the vacuum hose (the reference method) and (2) the ALK device. Duplicate dust samples were collected for 2 min from 2 m(2) of 37 living room floors and from each longitudinal half of 37 mattresses. Measurement of Der p 1 and Fel d 1 were by double monoclonal antibody enzyme-linked immunosorbent assay (ELISA) and endotoxin by a Limulus Amobocyte Lysate assay. Geometric mean ratios (95% confidence intervals) were calculated to show the differences between sampling devices for each measurement. Compared with the ALK device, the reference method collected significantly more dust from floors (sevenfold) and mattresses (threefold) and more total Der p 1, Fel d 1, and endotoxin in both sites. Floor, but not mattress, Der p 1 concentrations were also significantly higher (threefold) using our reference method. We recommend that, in order to minimize sampling device bias, allergen and endotoxin are expressed as a concentration, and that the bed is considered the major source of allergen exposure. Practical Implications Dust sampling equipment can influence the dust yield. In order to have confidence in comparisons of allergen and endotoxin reservoir levels between centers, standardization in the use of sampling equipment is important.  相似文献   

2.
Allergy to indoor allergens can cause frequent and severe health problems in children. Because little is known about the content of allergens in the indoor environments in Norway, we wanted to assess the levels of cat, dog and mite allergens in schools and day-care centers in Oslo. Allergen levels in dust samples from 155 classrooms and 81 day-care units were measured using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Additionally, we measured the levels of endotoxin in 31 day-care units, using the limulus amebocyte lysate test. Most of the dust samples contained detectable amounts of cat and dog allergens. In mattress and floor dust (day-care centers), and curtain and floor dust (schools) the median Fel d 1 levels were 0.17, 0.002, 0.02 and 0.079 microg/m2, while the median Can f 1 levels were 1.7, 0.03, 0.1 and 0.69 microg/m2, respectively. Levels of cat and dog allergens in school floor dust were associated with the number of pupils with animals at home. In contrast, <1% of the samples had measurable levels of the mite allergen Der p 1. Moreover, the levels of endotoxin tended to be higher in dust from floors (1.4 ng/m2) compared with that from mattresses (0.9 ng/m2). PRACTICAL IMPLICATIONS: To reduce allergen exposure, allergic individuals should be placed in the classes/rooms with the fewest pet owners. Moreover, mattresses in day-care centers are major reservoirs of cat and dog allergens and should be cleaned frequently.  相似文献   

3.
Abstract Residential microbial exposure has been suggested to be involved in the development of asthma. This paper describes bacterial endotoxin and mold β(1→3)-glucan levels in house dust and the relationship to selected home characteristics. Dust was sampled from mattresses and living room and bedroom floors of 25 houses in Germany. Endotoxin and β(1→3)-glucan levels ranged from 200-48,600 EU/g dust (100-32,900 EU/m2 sampled surface) and 182-3,507 μg/g (157-3,652 μg/m2), respectively. Bio-contaminant levels were highest on living room floors and lowest in mattresses. Dust, endotoxin and β(1→3)-glucan levels were 2–3 times higher on living room floors of centrally heated houses built after 1970 compared to older individually heated houses. This was not found for mattresses and bedroom floors. No associations between biocontaminant levels and other selected home characteristics (temperature, relative humidity, damp spots and insulation of windows) were found. β(1→3)-glucan levels were associated with total culturable fungi (per m2) in house dust, as well as with the fungal genus Alternaria (per g dust and per m2). In conclusion endotoxin and β(1→3)-glucan were readily detectable in house dust and significantly associated with heating system and/or age of the home.  相似文献   

4.
BACKGROUND: Exposure to indoor allergens has already been shown to occur in many public places, including workplaces, in several countries. Aim of this study was to measure the levels of house dust mites, cat and cockroach allergens in indoor workplaces (offices and archives) in Italy and to evaluate the possible relationships between allergen levels and building characteristics, type of ventilation, indoor relative humidity and temperature. METHODS: Der f 1 and Der p 1, Fel d 1, Bla g 2 were measured by ELISA in dust samples collected from floors or upholstered seats of 160 workplaces. RESULTS: Detectable Der p 1 levels were found in 86 (54%) workplaces Der f 1 in 87 (55%), Fel d 1 in 86 (54%) and Bla g 2 in 3 (1.9%). Der p 1 allergen concentrations expressed per weight were higher than the proposed sensitization thresholds in 7 samples, Der f 1 in 5, Fel d 1 in 6 and Bla g 2 in 3. The highest allergen levels were detected in samples from upholstered seats. A significant correlation was found between Der f 1 level on floors, expressed per surface, and indoor temperature (r = 0.39; P < 0.01). CONCLUSIONS: In our study we found that upholstered seats in workplaces in Italy may constitute a significant reservoir both of house dust mites and cat allergens. Exposure to these allergens in workplaces may represent a risk factor for elicitation of symptoms and/or induction/maintenance of inflammation in allergic individuals and might also constitute a risk factor for sensitization.  相似文献   

5.
In addition to mold, indoor bioaerosols also contain bacterial components that may have implications for human health. Endotoxin is a cell wall component in Gram-negative bacteria present at varying levels indoors that has been found to have respiratory health implications. Streptomyces is a large genus of Gram-positive bacteria, and some species have been shown to produce inflammatory reactions in vitro and in vivo. The aim of this study was to determine predictors of streptomycetes levels in house dust and to compare the variation in streptomycetes levels with that in endotoxin levels. Dust was collected by floor vacuuming from 178 homes in the Cincinnati metropolitan area. Streptomycetes levels were measured by quantitative PCR, and endotoxin was assayed by the Limulus amebocyte lysate method. Associations between home characteristics and bacterial contaminants, expressed as concentration and load, were investigated through multiple regression analyses. The presence of two or more dogs was a strong predictor of both streptomycetes and endotoxin levels. Season of dust collection and levels of outdoor molds were predictors of streptomycetes but not endotoxin levels. In contrast, number of inhabitants was a significant predictor of endotoxin load only. Neither streptomycetes nor endotoxin levels were associated with metrics of moisture damage.  相似文献   

6.
On-site home visits, consisting of a home inspection, dust sampling, and questionnaires were conducted in 777 homes belonging to an ongoing birth cohort study in Cincinnati, Ohio. Various home characteristics were investigated, and antigen levels (concentrations [microg/g] and loadings [microg/m(2)]; IU for cockroach allergen) in floor dust samples collected in child's primary activity room were analyzed by ELISA. Monoclonal antibodies were used for the analysis of cat, house dust mite, and cockroach allergens, and polyclonal antibodies for Alternaria and dog antigens. The relationship between the antigen levels and home characteristics was investigated through a generalized multiple regression model. More than half of the homes experienced mold/water damage. Cats and dogs were present in 19.7% and 31.1% of homes, respectively. More than 90% of homes had either carpet or area rug covering their floors. Among 777 homes, 87-92% of homes had measurable amount of Alternaria, cat, and dog allergen/antigen in house dust, whereas only 38% and 14% of homes had measurable levels of house dust mite and cockroach, respectively. Alternaria antigen level in house dust was not associated with visual mold/water damage, which was suspected to be one of the sources for this antigen in homes. Instead, the antigen level was high in samples taken in fall and in homes having dogs implicating that Alternaria antigen appears to be transported from outdoors to indoors. A high level was also measured in homes using a dehumidifier (these homes have experienced excessive humidity) and in-home venting of clothes dryer, which might be associated with microclimate affecting mold growth and spore release. The allergen/antigen level (both concentration and loading) of cat, dog and cockroach was significantly associated with the number of cats and dogs, or the appearance of cockroaches, respectively. High level of house dust mite allergen was measured in bedrooms and in homes using dehumidifier and no central forced air heating system. Having indoor plants was shown to reduce allergen levels. Carpeted floor was found to hold larger amount of antigens than non-carpeted floor. Antigen loading demonstrated more consistent and larger numbers of associations with home characteristics compared to antigen concentration. This study encompassed a wide range of home characteristics and various antigen types. Our findings provide information on home characteristics that can be used for allergen avoidance and in planning future exposure assessment studies.  相似文献   

7.
Exposure to allergens from house dust-mites (Der p 1) and domestic cats (Fel d 1) is associated with symptom severity in atopic subjects with asthma and rhinitis. Assessment of allergen exposure in the domestic environment is normally determined by measurement from a single floor site. We determined the variability of these allergens and protein throughout the whole living room floor area. Dust samples were collected from 1 m2 areas from 16 carpeted living room floors in Wellington, New Zealand, and analyzed for concentrations of Der p 1 and Fel d 1. Mean coefficients of variation for Der p 1 and Fel d 1 were 53.1% (range: 28.5-136.8) and 65.6% (range: 28.5-131), respectively. This study has demonstrated a large variation of house dust-mite and cat allergens within living room floors and thus a single sampling site may not be representative for assessment of an individual's exposure risk. House dust-mite and cat allergen levels from the center of the room, in front of a couch or chair, or from a corner of the room are similar to mean levels from the whole room, these sites may thus be representative of the whole living room floor in large-scale epidemiological studies.  相似文献   

8.
Exposure to allergens from house dust-mites (Der p 1) and domestic cats (Fel d 1) is associated with symptom severity in atopic subjects with asthma and rhinitis. Assessment of allergen exposure in the domestic environment is normally determined by measurement from a single floor site. We determined the variability of these allergens and protein throughout the whole living room floor area. Dust samples were collected from 1 m2 areas from 16 carpeted living room floors in Wellington, New Zealand, and analyzed for concentrations of Der p 1 and Fel d 1. Mean coefficients of variation for Der p 1 and Fel d 1 were 53.1% (range: 28.5-136.8) and 65.6% (range: 28.5-131.0), respectively. This study has demonstrated a large variation of house dust-mite and cat allergens within living room floors and thus assessment of a single sampling site may not be representative of an individual's exposure risk. House dust-mite and cat allergen levels from the center of the room, in front of a couch or chair, or from a corner of the room are similar to mean levels from the whole room. These sites may thus be representative of the whole living room floor in large-scale epidemiological studies.  相似文献   

9.
Air and dust samples were collected on two floors of an office building during a double-blind particle intervention study to examine spatial and temporal variability of airborne endotoxin over a period of weeks, and to characterize endotoxin activity and lipopolysaccharide (LPS) content in carpet and chair dust. Air samples were collected on multiple days within and across weeks. Dust samples were collected from carpets and chairs one day per week for three weeks. Endotoxin was measured using a Limulus assay. Dust samples were analyzed for LPS by determination of 3-hydroxy fatty acids (3-OHFAs) using gas chromatography-mass spectrometry. The geometric mean (geometric standard deviation) for 96 indoor air samples was 0.24 (1.6) EU/m3. Significant within-floor spatial variation of airborne endotoxin was found (P < 0.0001, n = 80). Temporal variability of airborne endotoxin was not significant across weeks. Mean (+/- SD) endotoxin levels in carpet dust (59 +/- 9.3 EU/mg dust, n = 12) and in chair dust (38 +/- 7.7 EU/mg dust, n = 10) were significantly different (P < 0.001). Carbon chain length-dependent differences in 3-OHFA levels by dust source and floor were found. Enhanced air filtration did not significantly affect airborne endotoxin (P = 0.62); however, total dust mass and total endotoxin in carpet dust samples increased significantly after enhanced surface cleaning (P < 0.01). These findings suggest that spatial variability, dust source, and surface cleaning may influence building occupant exposures to endotoxin.  相似文献   

10.
Considering that high school students spend a large proportion of their waking hours in the school environment, this could be an important location for exposure to indoor allergens. We have investigated the levels of mouse and cockroach allergens in the settled dust and air from 11 schools in a major northeastern US city. Settled dust samples were vacuumed from 87 classrooms, three times throughout the school year. Two separate air samples (flow = 2.5 lpm) were collected by 53 students over a 5-day period from both their school and their home. Mouse allergen (MUP) in the dust varied greatly between schools with geometric means ranging from 0.21 to 133 microg/g. Mouse allergen was detectable in 81% of the samples collected. Cockroach allergen (Bla g 2) ranged from below limit of detection (<0.003 microg/g) to 1.1 microg/g. Cockroach allergen was detected (>0.003 microg/g) in 71% of the dust samples. Bla g 2 was detected in 22% of airborne samples from the schools. By comparison, mouse allergen was only detected in 5%. These results indicate that the school may be an important location for exposure to allergens from mice and cockroaches and is an indoor environment that should be considered in an overall allergen intervention strategy. PRACTICAL IMPLICATIONS: To date, cockroach and mouse allergen intervention strategies have been mainly focused on the home environment. Considering that children spend a significant amount of time in schools, some studies have assessed cockroach allergen levels in schools. This study provides a clearer picture of the distribution and variability of not only cockroach allergen, but also mouse allergen in the school environment. In addition, this study describes limitations of personal air sampling in a student population. Our results suggest that although cockroach and mouse allergens are commonly recovered in classroom dust samples of inner city schools, cockroach allergens are recovered in the personal air samples with a greater frequency relative to mouse allergens.  相似文献   

11.
Early‐life exposure to microbial agents may play a protective role in asthma and allergies development. Geographical differences in the prevalence of these diseases exist, but the differences in early‐life indoor microbial agent levels and their determinants have been hardly studied. We aimed to describe the early‐life levels of endotoxin, extracellular polysaccharides (EPS), and β(1‐3)‐glucans in living room dust of four geographically spread European birth cohorts (LISA in Germany, PIAMA in the Netherlands, INMA in Spain, and LUKAS2 in Finland) and to assess their determinants. A total of 1572 dust samples from living rooms of participants were analyzed for endotoxin, Penicillium/Aspergillus EPS, and β(1‐3)‐glucans. Information on potential determinants was obtained through questionnaires. Concentrations of endotoxin, EPS, and β(1‐3)‐glucans were different across cohorts. Concentrations of endotoxin and EPS were respectively lower and higher in INMA than in other cohorts, while glucans were higher in LUKAS2. Season of sampling, dog ownership, dampness, and the number of people living at home were significantly associated with concentrations of at least one microbial agent, with heterogeneity of effect estimates of the determinants across cohorts. In conclusion, both early‐life microbial exposure levels and exposure determinants differ across cohorts derived from diverse European countries.  相似文献   

12.
Mite allergens are involved in airway sensitization and allergic diseases. We evaluated the exposure to house dust-mite (Der p 1 and Der f 1) and pet (Fel d 1 and Can f 1) allergens in hotels in Uberlandia, Midwestern Brazil. A total of 140 dust samples were collected from bedding (n = 98) and carpet (n = 42) of bedrooms in 20 hotels enrolled for this study. Geometric mean (GM) levels of Der f 1 (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) were significantly higher than Der p 1 (0.15 microg/g of dust; 95% CI: 0.13-0.18 microg/g) in bedding dust samples (P < 0.001), regardless of the hotel classes. Der f 1 levels were significantly higher in bedding (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) than carpet (6.32 microg/g of dust; 95% CI: 4.31-9.26 microg/g) dust samples (P < 0.05). High levels of Der f 1 (>10 microg/g of dust) were found in 58%, 76%, and 69% of dust samples from Simple, Economical, and Tourist/Superior hotels, respectively, while GM levels of Fel d 1 (0.11 microg/g of dust; 95% CI: 0.09-0.14 microg/g) and Can f 1 (0.30 microg/g of dust; 95% CI: 0.20-0.44 microg/g) were relatively low. These results indicate that Der f 1 is the predominant allergen in hotels in Uberlandia, especially in bedding dust samples, regardless of the hotel classes and could represent an important risk factor for exacerbation of allergic symptoms in previously mite-sensitized guests. PRACTICAL IMPLICATIONS: Mites and pets are important sources of indoor allergens. Most people spend the greatest part of their time indoors. Hotels can constitute an important allergen reservoir of the indoor environment and could represent an important risk for exacerbation of allergic symptoms in previously sensitized guests. Thus, hotels should also be included for planning indoor allergen avoidance as part of a global management strategy, especially in patients with respiratory allergy.  相似文献   

13.
Kim JL  Elfman L  Norbäck D 《Indoor air》2007,17(2):122-129
We studied reports on respiratory symptoms, asthma and atopic sensitisation in relation to allergen contamination in Korean schools and compared with data from a previous Swedish study performed in eight primary schools. Korean pupils (n = 2365) in 12 primary schools first completed a questionnaire. Then airborne and settled dust were collected from 34 classrooms and analyzed for allergens by ELISA. In both countries, boys reported more symptoms. The prevalence of wheeze was similar, while daytime [odds ratio (OR) = 14.0, 95% confidence interval (CI) = 9.0-21.9] and nocturnal breathlessness (OR = 3.1, 95% CI = 1.5-6.4) were much higher among Korean students. In Korean schools, dog allergen (Can f 1) was the most common followed by mite allergen (Der f 1), while cat (Fel d 1), dog, and horse allergen (Equ cx) were abundant in Sweden. Moreover, CO(2) levels were high in most Korean schools (range 907-4113 ppm). There was an association between allergen levels in dust and air samples, and number of pet-keepers in the classrooms. In conclusion, allergen contamination in Korean schools may be an important public issue. PRACTICAL IMPLICATIONS: This study showed that furry pet allergen contamination was common in both Korean and Swedish schools. In addition, house dust-mite (Der f 1) allergen contamination was common in Korean schools, probably because of transport of allergen from other environments. Transfer should therefore be minimized. Korean schools had high CO(2) levels and the concept of mechanical ventilation should be introduced. Measurement of airborne allergen levels is quite new and seems to be a more convenient and correct way to monitor allergen exposure in classrooms.  相似文献   

14.
This study examined: (i) biocontaminant levels in flooded homes of New Orleans two years after the flooding; (ii) seasonal changes in biocontaminant levels, and (iii) correlations between biocontaminant levels obtained by different environmental monitoring methods. Endotoxin, (1 → 3)-β-d-glucan, fungal spores, and dust mite allergens were measured in 35 homes during summer and winter. A combination of dust sampling, aerosolization-based microbial source assessment, and long-term inhalable bioaerosol sampling aided in understanding exposure matrices. On average, endotoxin found in the aerosolized fraction accounted for < 2% of that measured in the floor dust, suggesting that vacuuming could overestimate inhalation exposures. In contrast, the (1 → 3)-β-d-glucan levels in the floor dust and aerosolized fractions were mostly comparable, and 25% of the homes showed aerosolizable levels even higher than the dust-borne levels. The seasonal patterns for endotoxin in dust and the aerosolizable fraction were different from those found for (1 → 3)-β-d-glucan, reflecting the temperature and humidity effects on bacterial and fungal contamination. While the concentration of airborne endotoxin followed the same seasonal trend as endotoxin aerosolized from surfaces, no significant seasonal difference was identified for the concentrations of airborne (1 → 3)-β-d-glucan and fungal spores. This was attributed to the difference in the particle size; smaller endotoxin-containing particles can remain airborne for longer time than larger fungal spores or (1 → 3)-β-d-glucan-containing particles. It is also possible that fungal aerosolization in home environments did not reach its full potential. Detectable dust mite allergens were found only in dust samples, and more commonly in occupied homes. Levels of endotoxin, (1 → 3)-β-d-glucan, and fungi in air had decreased during the two-year period following the flooding as compared to immediate measurements; however, the dust-borne endotoxin and (1 → 3)-β-d-glucan levels remained elevated. No conclusive correlations were found between the three environmental monitoring methods. The findings support the use of multiple methods when assessing exposure to microbial contaminants.  相似文献   

15.
Exposure to house dust has been associated with asthma in adults, and this is commonly interpreted as a direct immunologic response to dust‐mite allergens in those who are IgE sensitized to house dust‐mite. Mattress house dust‐mite concentrations were measured in a population‐based sample of 2890 adults aged between 27 and 56 years living in 22 centers in 10 countries. Generalized linear mixed models were employed to explore the association of respiratory symptoms with house dust‐mite concentrations, adjusting for individual and household confounders. There was no overall association of respiratory outcomes with measured house dust‐mite concentrations, even in those who reported they had symptoms on exposure to dust and those who had physician‐diagnosed asthma. However, there was a positive association of high serum specific IgE levels to HDM (>3.5 kUA/l) with mattress house dust‐mite concentrations and a negative association of sensitization to cat with increasing house dust‐mite concentrations. In conclusion, there was no evidence that respiratory symptoms in adults were associated with exposure to house dust‐mite allergen in the mattress, but an association of house mite with strong sensitization was observed.  相似文献   

16.
Frankel M  Timm M  Hansen EW  Madsen AM 《Indoor air》2012,22(5):405-414
Abstract Indoor microbial exposure has been related to allergy and respiratory disorders. However, the lack of standardized sampling methodology is problematic when investigating dose-response relationships between exposure and health effects. In this study, different sampling methods were compared regarding their assessment of microbial exposures, including culturable fungi and bacteria, endotoxin, as well as the total inflammatory potential (TIP) of dust samples from Danish homes. The Gesamtstaubprobenahme (GSP) filter sampler and BioSampler were used for sampling of airborne dust, whereas the dust fall collector (DFC), the electrostatic dust fall collector (EDC), and vacuum cleaner were used for sampling of settled dust. The GSP assessed significantly higher microbial levels than the BioSampler, yet measurements from both samplers correlated significantly. Considerably higher levels of fungi, endotoxin, and TIP were found in the EDC compared with the DFC, and regarding fungi, the EDC correlated more strongly and significantly with vacuumed dust than the DFC. Fungi in EDC and vacuum dust correlated most strongly with airborne dust, and in particular, the measurements from the EDC associated well with those from GSP. Settled dust from the EDC was most representative of airborne dust and may thus be considered as a surrogate for the assessment of indoor airborne microbial exposure. PRACTICAL IMPLICATIONS: Significant discrepancies between sampling methods regarding indoor microbial exposures have been revealed. This study thus facilitates comparison between methods and may therefore be used as a frame of reference when studying the literature or when conducting further studies on indoor microbial exposure. Results also imply that the relatively simple EDC method for the collection of settled dust may be used as an alternative to otherwise tedious and time-consuming airborne dust sampling.  相似文献   

17.
Allergen exposure is a risk to develop an IgE-mediated sensitization. The amount of allergen inhaled per unit time should be related to the amount present in the air, i.e. airborne allergen. Thus, measuring allergen levels in the air would be more relevant than measuring allergen levels in dust. Allergens are present in the air in very minute quantities and usually become airborne after disturbance. Large variation of allergen levels have been found in dust. In this study, we measured variability of airborne cat allergen, Fel d1, in a public place using a high-volume air-sampler. We also studied the distribution and relationship between dust and airborne cat allergens in homes and schools. Air samples were collected at three different airflow rates, i.e. 55, 40, and 30 m3 of air per hour. The concentration of airborne Fel d1 in the community gymnastic hall varied from 1 to 10 pg/m3 within a period of 3 weeks, at airflow rates 55-30 m3/h. The coefficient of variation for repeated samplings was 14-43% (day-to-day variation) and 27-38% (within-day variation). As expected, higher levels of airborne cat allergens were found in homes with cats than in cat-free environments. There was a significant relationship between cat allergen levels in dust and air (r=0.7, P<0.01). Our study demonstrates that when measuring airborne cat allergen a large variation is observed within a day and between days. The large variability of measurement may be explained by the disturbance in the environments. We suggest, that when exposure assessment is made the environment in question should be analyzed, if possible in several occasions.  相似文献   

18.
East-West differences in prevalence of asthma and allergies were suggested to be associated with lifestyle factors. To describe endotoxin levels in mattress dust samples from East and West German homes collected approximately 10 years after reunification. To identify factors that may account for an East-West difference. Dust was collected from mattresses of 2157 infants and 2108 mothers living in Leipzig (former East Germany) and Munich (West Germany). Endotoxin was measured using a chromogenic kinetic Limulus amoebocyte lysate test. Data on bedding, dwelling, and housing characteristics, and occupants' behavior were collected using a self-administered questionnaire. Endotoxin levels were significantly higher in Leipzig compared with Munich for the infants' mattresses but not for the mothers' mattresses. Apart from this, predictors for the mothers' and the infants' mattresses were very similar. Pet-ownership and contact with animals outside the home were most influential. Endotoxin levels in mattress dust were highest in summer and increased with the number of persons living in the household. The overall percentage of variability in endotoxin levels explained by these factors was low. Endotoxin levels were associated with lifestyle factors discussed within the framework of the hygiene hypothesis. None of these factors explains the difference in infant's mattress dust endotoxin between Leipzig and Munich or could be used as a surrogate for endotoxin. PRACTICAL IMPLICATIONS: Endotoxin levels in mattress dust are associated with a number of factors discussed in the framework of the hygiene hypothesis; among other things they are associated with pet-ownership, contact with pets and number of persons living in the home. However, none of these factors and not even a combination of factors explains the variability of endotoxin levels between homes.  相似文献   

19.
We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child who was allergic to cockroach allergen resided. Four simultaneous air samples were collected in each home: at heights of 0.3 and 1 m in the child's bedroom and in the kitchen. Extracts of air samples were analyzed by ELISA for the cockroach allergen Bla g2, modified by amplifying the colorimetric signal generated via use of AMPLI-Q detection system (DAKO Corporation, Carpinteria, CA, USA). Settled dust samples were quantified by conventional ELISA. Of the homes where cockroach allergen was detected in settled dust, Bla g2 also was detected in 87% and 93% of air samples in the bedroom and kitchen, respectively. Airborne Bla g2 levels were highly correlated within and between the bedroom and kitchen locations (P < 0.001). Expressed as picogram per cubic meter, the room average geometric mean for Bla g2 concentrations was 1.9 pg/m3 (95% CI 0.63, 4.57) and 3.8 pg/m3 (95% CI 1.35, 9.25) in bedrooms and kitchens, respectively. This method offers an attractive supplement to settled dust sampling for cockroach allergen exposure health studies. PRACTICAL IMPLICATIONS: Until now, cockroach allergen exposures have usually been assessed by collection and analysis of settled dust, on the assumption that airborne cockroach allergen cannot be reliably measured. In this study, a sensitive and quantitative method for measuring indoor airborne exposures to cockroach allergens involving a 7-day integrated total suspended particulate (TSP) sample collected at approximately 10-15 l/min was developed. Investigators are now empowered with an alternative exposure assessment method to supplement their studies and the understanding of allergen aerodynamics in the homes of children with asthma. We report airborne cockroach allergen in apartments, suggesting an ongoing burden of inhalation exposure.  相似文献   

20.
Endotoxin exposures have manifold effects on human health. The geographical variation and determinants of domestic endotoxin levels in Europe have not yet been extensively described. To investigate the geographical variation and determinants of domestic endotoxin concentrations in mattress dust in Europe using data collected in the European Community Respiratory Health Survey follow-up (ECRHS II). Endotoxin levels were measured in mattress dust from 974 ECRHS II participants from 22 study centers using an immunoassay. Information on demographic, lifestyle, and housing characteristics of the participants was obtained in face-to-face interviews. The median endotoxin concentration in mattress dust ranged from 772 endotoxin units per gram (EU/g) dust in Reykjavik, Iceland, to 4806 EU/g in Turin, Italy. High average outdoor summer temperature of study center, cat or dog keeping, a high household crowding index, and visible damp patches in the bedroom were significantly associated with a higher endotoxin concentrations in mattress dust. There is a large variability in domestic endotoxin levels across Europe. Average outdoor summer temperature of study center, which explains only 10% of the variation in domestic endotoxin level by center, is the strongest meteorological determinant. The observed variation needs to be taken into account when evaluating the health effects of endotoxin exposures in international contexts. PRACTICAL IMPLICATIONS: The incoherent observations of the health effects of endotoxin may be partly owing to the geographical heterogeneity of endotoxin exposure. Therefore, the observed variation should be considered in further studies. Measurements of indoor endotoxin are recommended as an indicator for the level of exposures of individual domestic environments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号