共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
BACKGROUND: In treating venous thromboembolic disorders, patient outcomes appear to correlate with heparin levels. Due to pharmacokinetic and pharmacodynamic variations, a relationship between heparin dose and level cannot be reliably predicted in individual patients. Some patients have low heparin levels despite therapeutic activated partial thromboplastin times (aPTTs), which may increase their risk for recurrent thromboembolism. Patients with high heparin requirements appear to have fewer bleeding episodes with heparin level-guided therapy. The aPTT does not reliably correlate with heparin blood concentrations or antithrombotic effects. Consequently, heparin therapy monitored with heparin levels may be more effective and safer. OBJECTIVES: To prospectively determine whether (1) the aPTT therapeutic range adequately predicts heparin levels in 38 patients used to establish the therapeutic aPTT range as is currently recommended and (2) whether 3 paired sets of aPTT-antifactor Xa levels provide the basis for using aPTTs to predict subsequent heparin levels in individual patients (n = 27) receiving intravenous heparin for coronary artery disease or venous thromboembolic disease. RESULTS: In the therapeutic aPTT range established, the R2 value for the relationship was 0.4. Prediction intervals were wide. For an aPTT of 60 seconds, the 95% prediction interval estimates were heparin levels of 0.05 to 1.0 U/mL. In individual patients, the aPTT-antifactor Xa relationship had an average R2 value of 0.75. There was no consistent relationship between the aPTT and anti-factor Xa level in a significant number of patients. CONCLUSIONS: The aPTT does not appear to be a useful surrogate for heparin levels. These findings suggest that the current recommendations on the use of heparin levels should be expanded. 相似文献
3.
CP Cannon J Dingemanse CH Kleinbloesem T Jannett KM Curry CP Valcke 《Canadian Metallurgical Quarterly》1999,99(6):751-756
BACKGROUND: Unfractionated heparin is used widely; however, control of the level of anticoagulation remains its greatest problem, with fewer than 35% of patients having activated partial thromboplastin times (aPTTs) within a range of 55 to 85 seconds in recent trials. METHODS AND RESULTS: We developed and tested a prototype of an automated heparin control system (AutoHep) in which a computer-based titration algorithm adjusted the heparin infusion to reach a target aPTT. In 1 study, 12 healthy male subjects received an intravenous infusion of heparin with the rate determined by AutoHep and were randomized to receive an initial bolus or no bolus of heparin preceding the infusion. A second study evaluated the automated blood sampling system in 12 subjects. Of the 344 end-point aPTT measurements, 78% were within +/-10 seconds of the target (prespecified primary end point), and 89% were within a +/-15-second range. The time to achieve a target aPTT was 93 minutes without and 150 minutes with an initial heparin bolus. The total percentage of time within the target range +/-15 seconds was 46 of 48 hours (96%). The automatic blood sampling system successfully obtained 96% of all scheduled samples. CONCLUSIONS: These results suggest that the AutoHep system has the potential to significantly improve aPTT control of intravenous heparin compared with current clinical practice. 相似文献
4.
Heparin is an effective drug for prevention and treatment of thromboembolic conditions. Although several biological assays have been proposed for monitoring unfractionated heparin therapy, the measurement of the activated partial thromboplastin time (APTT) is the most widely employed test, and the overall risk of thromboembolic episodes was markedly reduced by maintaining APTT ratios above 1.5. However, the adjustment of the heparin therapy on the basis of APTT presents several questions which are still unresolved. Major discrepancies were found in APTTs performed using different reagents in both ex vivo and in vitro heparinized samples and occasionally with different lots of the same reagents; poor correlation was observed between APTT values and plasma heparin concentrations. In order to gain further insights into this phenomenon, we analysed the sensitivity to heparin of five commercial reagents for APTT measurement in 19 ex vivo heparinized samples. Differences were observed; correlation coefficients ranged from 0.820 to 0.985 and slopes of linear regressions from 0.26 to 1.14. Moreover, unsatisfactory correlations were obtained when APTT ratios were compared with heparin plasma concentrations in the same patients' samples. In the heparin therapeutic range of 0.35 - 0.70 U/ml, reagent-dependent differences were observed in the corresponding APTT values. These results point out a critical role of the assay methodology in monitoring heparin therapy by APTT. We suggest that reference materials and methods should be urgently identified, a universally agreed scale for reporting results should be established and reference ranges for the unfractionated heparin therapy should be reconsidered taking on account the reagent employed. 相似文献
5.
AM van den Besselaar J Neuteboom J Meeuwisse-Braun RM Bertina 《Canadian Metallurgical Quarterly》1997,43(7):1215-1222
To contribute to the development of a reference reagent for monitoring heparin therapy, a lyophilized partial thromboplastin time (PTT) reagent was prepared from synthetic dioleoylphosphatidylcholine, dioleoylphosphatidylserine, and dioleoylphosphatidylethanolamine, with colloidal silica as activator. The reagent, coded 91/558, was contained in sealed glass ampoules; it deteriorated in a heat degradation experiment, but its activity remained constant for at least 4 years when stored at -70 degrees C. Within- and between-run precision with this reagent complied with the requirements proposed by the International Committee for Standardization in Haematology (ICSH) Panel on PTT. The response of this reagent and of two other reagents to heparin added to pooled normal plasma was nonlinear. Citrated samples from 58 patients receiving intravenous heparin and from 24 apparently healthy volunteers were tested with reagent 91/558, with Automated APTT (Organon Teknika), with Manchester APTT reagent, with an antifactor Xa assay, and with an anti-factor IIa assay. The correlation of APTT with anti-Xa and anti-IIa activity was poor. The best correlation was observed between reagent 91/558 and the Organon Teknika reagent. Correlations were improved when individual patients' samples were replaced by pooled plasmas from heparinized patients, in whom the effect of oral anticoagulation was minimal. These results suggest that preparation of a lyophilized synthetic phospholipid reagent is feasible for use in monitoring heparin therapy. 相似文献
6.
HE Branson N Gupta LM Slater A Fagin SA Armentrout 《Canadian Metallurgical Quarterly》1982,12(4):411-418
Activated partial thromboplastin time after heparin removal (aPTT/HR), a test employing anion exchange chromatography, was devised as an alternative to the prothrombin time after heparin removal (PT/HR) to monitor simultaneous anticoagulation with heparin and coumarins. The potential utility of the aPTT/HR was assessed by performing parallel PTs and aPTTs on 62 consecutive plasmas from coumarin-treated outpatients. All samples had 0.2 units/ml of heparin added and then removed to see if the maneuver influenced therapeutic group assignment. In no instance did reassignment occur. A conditional Irwin-Fisher test (P = 0.000604) and a special multinomial trial analysis (P = 0.002) indicated that the aPTT would be at least comparable to the PT for following coumarin antithrombotic prophylaxis. Since the heparin removal procedure had no influence on therapeutic categorization, the same statistical proof could be applied to the relationship between aPTT/HR and PT/HR. This study indicates that the aPTT can be used to monitor all stages of heparin and /or coumarin anticoagulation. 相似文献
7.
8.
Of 1068 blood samples referred for evaluation of the haemostatic mechanism 135 contained heparin as judged by the polybrene titration method. Of the 57 samples with a heparin concentration in the defined therapeutic range, 65 per cent had APTT values in the "therapeutic range". Of the samples from patients who had not received any anticoagulant, 213 (24 per cent) had prolonged APTT, and 48 of these samples had APTT values in the "therapeutic range" for heparin therapy. It is suggested that the APTT test is of limited value in monitoring heparin therapy. 相似文献
9.
KM Zabel CB Granger RC Becker EG Bovill J Hirsh PE Aylward EJ Topol RM Califf 《Canadian Metallurgical Quarterly》1998,136(5):868-876
Multiple five-day testing of rats in the open field and elevated plus-maze revealed a regressive dynamics of the integral characteristics of the exploratory behavior. The integral quantitative indices of searching activity in Henderson's test of extrapolation deliverance (modified by N. A. Bondarenko) and in active shock avoidance in N. R. Grigor'ev's problem box, on the contrary, displayed a progressive dynamics, like quantitative characteristics of cognitive activity. We established the differences between the determinants and control mechanisms of exploratory behavior and searching activity. This allowed us to differentiate these forms of behavior as different functional states. 相似文献
10.
11.
M Ogasawara K Aoki K Katano T Aoyama Y Ozaki K Suzumori 《Canadian Metallurgical Quarterly》1998,70(6):1081-1084
OBJECTIVE: To determine whether clinically routine clotting tests such as activated partial thromboplastin time (aPTT), prothrombin time (PT), or fibrinogen can be used to predict further miscarriages. DESIGN: Prospective study. SETTING: Nagoya City University Hospital, Nagoya, Japan. PATIENT(S): A total of 261 patients with a history of two consecutive first-trimester spontaneous abortions who had no antiphospholipid antibodies or other autoimmune diseases and no anatomic anomalies were examined for aPTT, PT, and fibrinogen before becoming pregnant again. INTERVENTION(S): Blood tests were performed before pregnancy. Patients then were followed up during subsequent pregnancy and their outcomes were compared with their previous blood test results. MAIN OUTCOME MEASURE(S): Activated partial thromboplastin time, PT, and fibrinogen were measured by coagulation time methods. RESULT(S): Fifty-eight of 261 patients (22.2%) had a subsequent miscarriage. Mean (+/-SD) values for preconception aPTT in individuals whose subsequent pregnancies ended in success and failure were 88.2%+/-23.4% and 99.3%+/-26.4%, respectively. The difference was statistically significant. Respective values were 106.8%+/-22.8% and 106.3%+/-21.4% for PT and 245+/-61.1 mg/dL and 259.1+/-57 mg/dL for fibrinogen. These findings were not significantly different. CONCLUSION(S): A shortened aPTT before conception is associated with further miscarriages in patients with a history of recurrent spontaneous abortions who have no antiphospholipid antibodies. 相似文献
12.
TY Chan 《Canadian Metallurgical Quarterly》1998,36(7):403-405
Stress fractures in children are rare compared with the incidence in adults. This report describes an 11-year-old girl with stress fractures of the acromion, clavicle, and first rib on the left and contralateral fractures of the first and second ribs. It was eventually discovered that these fractures were caused by a nervous tic consisting of repetitive, vigorous shrugging and translation of the shoulders. 相似文献
13.
T Sakurada Y Kikuchi R Koushima S Nakashima Y Hachiro H Kagaya 《Canadian Metallurgical Quarterly》1997,45(6):836-840
The strength of neural response to sensory stimuli is often estimated by measurement of the amplitude of gross neural potentials. These gross potentials reflect the summed activity of a population of neurons. The amplitude of these potentials is dependent upon the synchrony of the contributing neural responses. We compared the variability of the peak-to-peak amplitude of the auditory nerve compound action potential (CAP) with that of the area under the peaks. The area under the peaks was significantly less variable than the amplitude for responses to low frequency stimuli. Responses to other stimuli showed differences in the same direction, but these were not significant. We conclude that the area under these peaks is a more precise measure of neural response than measurement of waveform amplitude at least for responses to low frequency stimuli. 相似文献
14.
GJ Despotis KS Filos V Levine A Alsoufiev E Spitznagel 《Canadian Metallurgical Quarterly》1996,82(6):1126-1131
This study was designed to evaluate the effect of aprotinin on activated versus nonactivated whole blood clotting time using two different on-site methods and to quantify these anticoagulant properties when compared to heparin in a controlled, in vitro environment. Blood specimens were obtained prior to heparin administration from 56 patients undergoing cardiac surgery. Specimens obtained from the first consecutive 20 patients were mixed with either normal saline (NS) or aprotinin (400 kallikrein inhibiting units (KIU)/mL), inserted into Hemochron tubes containing either NS or heparin (0.3 or 0.6 U/mL) and then used to measure celite-activated (celite ACT) and nonactivated whole blood clotting time (WBCT1) using four Hemochron instruments. Accordingly, specimens obtained from the second consecutive 20 patients were mixed with either NS or aprotinin, inserted into Automated Clot Timer cartridges containing either NS or heparin (0.06, 0.13, or 0.25 U/mL) and then used to measure kaolin-activated (kaolin ACT) or nonactivated whole blood clotting times (WBCT2) using four Automated Clot Timer instruments. Specimens obtained from the last 16 patients were mixed with either incrementally larger doses of aprotinin (0, 100, 200, 300, or 400 KIU/mL) or heparin (0, 0.12, 0.24, 0.36, 0.48, or 0.72 U/mL) and were then used for measurement of whole blood clotting time (WBCT2) using six Automated Clot Timer instruments. Aprotinin significantly prolonged activated or nonactivated whole blood clotting time and potentiated the prolongation of whole blood clotting time by heparin. The linear relationship between whole blood clotting time and either heparin concentration (WBCT2 = H x 357 + 280, mean adjusted r2 = 0.88) or aprotinin concentration (WBCT2 = A x 0.97 + 300, mean adjusted r2 = 0.94) was variable among patients. On average, 200 KIU/mL of aprotinin prolonged WBCT2 to the same extent as 0.69 +/- 0.28 U/mL of heparin using linear regression models within each patient. Aprotinin significantly prolongs activated or nonactivated whole blood clotting time measurements in a dose-dependent manner. Since prolongation of whole blood clotting time by heparin is potentiated by aprotinin in vitro, aprotinin's anticoagulant properties may in part account for the prolonged celite activated clotting time values observed in the presence of aprotinin. 相似文献
15.
MJ Glantz PC Burger AH Friedman RA Radtke EW Massey SC Schold 《Canadian Metallurgical Quarterly》1994,44(11):2020-2027
When radiation is used to treat nervous system cancer, exposure of adjacent normal nervous system tissue is unavoidable, and radiation-induced injury may occur. Acute injury is usually mild and transient, but late forms of radiation-induced nervous system injury are usually progressive and debilitating. Treatment with corticosteroids, surgery, and antioxidants is often ineffective. We treated 11 patients with late radiation-induced nervous system injuries (eight with cerebral radionecrosis, one with a myelopathy, and two with plexopathies, all unresponsive to dexamethasone and prednisone) with full anticoagulation. Some recovery of function occurred in five of the eight patients with cerebral radionecrosis, and all the patients with myelopathy or plexopathy. Anticoagulation was continued for 3 to 6 months. In one patient with cerebral radionecrosis, symptoms recurred after discontinuation of anticoagulation and disappeared again after reinstitution of treatment. We hypothesize that anticoagulation may arrest and reverse small-vessel endothelial injury--the fundamental lesion of radiation necrosis--and produce clinical improvement in some patients. 相似文献
16.
CB Granger J Hirsch RM Califf J Col HD White A Betriu LH Woodlief KL Lee EG Bovill RJ Simes EJ Topol 《Canadian Metallurgical Quarterly》1996,93(5):870-878
BACKGROUND: Although intravenous heparin is commonly used after thrombolytic therapy, few reports have addressed the relationship between the degree of anticoagulation and clinical outcomes. We examined the activated partial thromboplastin time (aPTT) in 29,656 patients in the Global Utilization of Streptokinase and t-PA for Occluded Coronary Arteries (GUSTO-I) trial and analyzed the relationship between the aPTT and both baseline patient characteristics and clinical outcomes. METHODS AND RESULTS: Intravenous heparin was administered as a 5000-U bolus followed by an initial infusion of 1000 U/h, with dose adjustment to achieve a target aPTT of 60 to 85 seconds. aPTTs were collected 6, 12, and 24 hours after thrombolytic administration. Higher aPTT at 24 hours was strongly related to lower patient weight (P < .00001) as well as older age, female sex, and lack of cigarette smoking (all PT< .0001). At 12 hours, the aPTT associated with the lowest 30-day mortality, stroke, and bleeding rates was 50 to 70 seconds. There was an unexpected direct relationship between the aPTT and the risk of subsequent reinfarction. There was a clustering of reinfarction in the first 10 hours after discontinuation of intravenous heparin. CONCLUSIONS: Although the relationship between aPTT and clinical outcome was confounded to some degree by the influence of baseline prognostic characteristics, aPTTs higher than 70 seconds were found to be associated with higher likelihood of mortality, stroke, bleeding, and reinfarction. These findings suggest that until proven otherwise, we should consider the aPTT range of 50 to 70 seconds as optimal with intravenous heparin after thrombolytic therapy. 相似文献
17.
Cost effectiveness of low-molecular weight heparin versus warfarin following hip replacement surgery
Little information is available on the efficacy of low-molecular-weight heparin (enoxaparin) versus warfarin for treatment of deep vein thrombosis and pulmonary embolism following hip replacement surgery. Still less is known of the comparative cost effectiveness of these two therapies. A retrospective study was done on 56 patients who underwent elective hip surgery at an urban medical center between 1991 and 1996. All patients received enoxaparin or warfarin for purposes of thromboprophylaxis. An analysis of medication cost, therapy, laboratory monitoring, and bleeding events of the two antithrombolytic agents was undertaken. Total savings with enoxaparin averaged $1253 per patient, or $137,886 over the study period. The incidence of deep vein thrombosis or pulmonary embolism was 0% with enoxaparin and 3% with warfarin. These data indicate that enoxaparin is a more cost-effective and efficacious regimen for thromboprophylaxis following hip replacement surgery than warfarin. 相似文献
18.
19.
GJ Despotis V Levine JH Joist D Joiner-Maier E Spitznagel 《Canadian Metallurgical Quarterly》1997,85(3):498-506
This study was designed to determine if, and to what extent, antithrombin III (AT) levels affect the response of the activated clotting time (ACT) to heparin in concentrations used during cardiac surgery, and to characterize the relationship between AT levels and markers of activation of coagulation during cardiopulmonary bypass (CPB). After informed consent, blood specimens obtained from eight normal volunteers (Phase I) were used to measure the response of the kaolin and celite ACT to heparin after in vitro addition of AT (200 U/dL) and after dilution with AT-deficient plasma to yield AT concentrations of 20, 40, 60, 80, and 100 U/dL. In Phase II, blood specimens collected before the administration of heparin and prior to discontinuation of CPB, were used to measure the response of the kaolin ACT to heparin (preheparin only), AT concentration, and a battery of coagulation assays in 31 patients undergoing repeat or combined cardiac surgical procedures. In Phase I, strong linear relationships were observed between kaolin (slope = 1.04 AT - 2, r2 = 0.78) and celite (slope = 1.36 AT + 6, r2 = 0.77) ACT slopes and AT concentrations below 100 U/dL. In the pre-CPB period of Phase II, only factors V (partial r = -0.49) and VIII (partial r = -0.63) were independently associated with heparin-derived slope using multivariate analysis; an inverse relationship was observed between AT and fibrinopeptide A levels (r = -0.41) at the end of CPB. Our findings indicate that the responsiveness of whole blood (ACT) to heparin at the high concentrations used with CPB is progressively reduced when the AT concentration decreases below 80 U/dL. Because AT is variably, and sometimes extensively, reduced in many patients before and during CPB, AT supplementation in these patients might be useful in reducing excessive thrombin-mediated consumption of labile hemostatic blood components, excessive microvascular bleeding, and transfusion of blood products. IMPLICATIONS: Heparin, a drug with anticoagulant properties, is routinely given to patients undergoing cardiac surgery to prevent clot formation within the cardiopulmonary bypass circuit. However, when levels are reduced, heparin is not as effective. Findings within this study indicate that administration of antithrombin III may help to preserve the hemostatic system during cardiopulmonary bypass. 相似文献
20.
HW Fisher 《Canadian Metallurgical Quarterly》1977,3(2):210-212
Patients on anticoagulants may undergo surgery if the anticoagulants are carefully controlled and if contraindications are respected. Patients being treated for thromboembolism should have their clotting times maintained at close to two times normal levels if they are on heparin, or their prothrombin times similarly maintained if they are an oral anticoagulants. 相似文献