1.
Shell and tube heat exchanger with single twisted tube bundle in five different twist angles, are studied using computational fluid dynamics (CFD) and compared to the conventional shell and tube heat exchanger with single segmental baffles. Effect of shell-side nozzles configurations on heat exchanger performance is studied as well. Heat transfer rate and pressure drop are the main issues investigated in the paper. The results show that, for the same shell-side flow rate, the heat transfer coefficient of heat exchanger with twisted tube bundle is lower than that of the heat exchanger with segmental baffles while shell-side pressure drop of the former is even much lower than that of the latter. The comparison of heat transfer rate per unit pressure drop versus shell-side mass flow rate shows that heat exchanger with twisted tube bundle in both cases of perpendicular and tangential shell-side nozzles, has significant performance advantages over the segmental baffled heat exchanger. Optimum bundle twist angles for such exchangers are found to be 65 and 55° for all shell side flow rates.  相似文献   

2.
An experimental investigation of the heat transfer and pressure drop performance of ten finned tube bundles using serrated fins is presented. All tube bundles had staggered layouts, and the influence on varying tube bundle layout, tube and fin parameters are presented. The heat transfer coefficient experienced a maximum when the flow areas in the transversal and diagonal planes were equal. An increase in the fin pitch increased the heat transfer coefficient; the same was observed with an increase in fin height. The pressure drop coefficient showed no influence of the tube bundle layout for small pitch ratios, but dropped significantly for higher ratios. Increasing fin pitch reduced the pressure drop, whereas varying fin height had insignificant effect. None of the literature correlations were able to reproduce the experiments for the entire range of tested conditions. A set of correlations were developed, reproducing the experimental data to within ±5% at a confidence interval of 95%.  相似文献   

3.
This study has suitably modified the existing heat transfer and pressure drop correction factors of the modified Bell–Delaware method used for heat exchangers with segmental baffles, taking into consideration the helical baffle geometry. These correction factors are presented in parametric formulas based on the Taborek presented procedure for segmental baffles. These formulas are functions of the geometrical and physical parameters of discontinuous helical baffles. In addition, the parametric formulas are presented graphically based on the Stehlik method. The correction design method proposed by Stehlik for the helical baffle is presented in detail and a theoretical model for shell-side heat transfer and pressure drop is developed. In general, the results show that the present model matches more closely with the graphically proposed correction factors of Stehlik. In order to calculate the shell-side heat transfer coefficient and pressure drop using the present method, a computational code has been developed by the authors. In addition, in order to examine the validity, the results of the code for a case study are compared with the results obtained from EXPRESS software and experimental formulas presented by Zhang. The results of comparison show that the proposed method is accurate and can be used by designers confidently.  相似文献   

4.
The thermal-hydraulic performance analysis code, ISGA (Integrated Steam Generator Analyzer) for the design of the integrated steam generator concept of double tube bundle steam generator (DTBSG), which is considered to eliminate a SWR possibility fundamentally in a sodium-cooled fast reactor, was developed for three candidate configurations of tube bundles; the integrated double region, integrated single region and radially separated bundle types. To verify the ISGA code and to confirm the viability of the concept, comparisons to experimental data have been carried out. The effects of properties deviation to total heat transfer rate are negligible through the sensitivity studies. General tendency of the temperature profiles seems to be reasonable for integrated type of the DTBSG. The multidimensional effects of the helical tube bundle which includes the entrance effect result in slight discrepancy. The calculated heat transfer rate curve shows a good agreement with the experimental data for the three types of DTBSGs. In the integrated type DTBSG, the convection heat transfer is less dominant for the heat transfer mechanism of the medium flow than in the radially separated type DTBSG. The feasibility of the three candidate DTBSG concepts was demonstrated and the validity of the 1-dimensional thermal-hydraulic analysis code ISGA was shown with comparisons to experimental data.  相似文献   

5.
In order to elucidate boiling heat transfer characteristics for each tube and the critical heat flux (CHF) for tube bundles, an experimental investigation of pool and flow boiling of Freon-113 at 0.1 MPa was performed using two typical tube arrangements. A total of fifty heating tubes of 14 mm diameter, equipped with thermocouples and cartridge heaters, were arrayed at pitches of 18.2 and 21.0 mm to simulate both square in-line and equilateral staggered bundles. For the flow boiling tests the same bundles as were used in pool boiling were installed in a vertical rectangular channel, to which the fluid was supplied with an approach velocity varying from 0.022 to 0.22 m/s. It was found in this study that the boiling heat transfer coefficient of each tube in a bundle was higher than that for an isolated single tube in pool boiling. This enhancement increases for tubes at higher locations, but decreases as heat flux is increased. At heat fluxes exceeding certain values, the heat transfer coefficient becomes the same as that for an isolated tube. As the heat flux approaches the CHF, flow pulsations occurred in the pool boiling experiments although the heat transfer coefficient was invariant even under this situation. The approach velocity has an appreciable effect on heat transfer up to a certain level of heat flux. In this range of heat flux, the heat transfer coefficient exceeds the values observed for pool boiling. An additive method with two contributions, i.e., single phase convection and boiling, was used to predict the heat transfer coefficient for bundles. The predicted results showed reasonable agreement with the measured results. The critical heat flux in tube bundles tended to increase as more bubbles were rising through the tube clearance. © 1998 Scripta Technica, Heat Trans Jpn Res, 27(4): 312–325, 1998  相似文献   

6.
利用可视化换热器性能实验台测试了微细管束表面在无换热、大温差、凝露条件下不同风速工况的流动损失与空气侧换热系数。同时探究了超低温工况下,相对湿度和风速对微细管束换热器流动换热特性影响。相对湿度增大,湿空气释放潜热增加,结霜量增大,换热器前后压损增加。高速气流具有剪切作用,风速增大会导致结霜迟滞。  相似文献   

7.
The feed water heaters in power plants are actually the condensers using turbine extracting steam to heat feed water. The vertical feed water heater occupies less area than the horizontal one and convenient to lift tube bundles out in maintenance. However, the lower heat transfer coefficient due to thick condensate film limits its application. A novel trisection helical baffled vertical condenser (feed water heater) is proposed with liquid dams and gaps for facilitating condensate drainage. The flow and condensation heat transfer characters of two vertical condensers with variable angled trisection helical baffles of both single-thread and dual-threads and a variable spanned segmental baffled one were numerically studied with Mixture model of Fluent software. The distributions of velocity, pressure, volume fraction of condensate, and local heat transfer coefficient in these heat exchangers were demonstrated. The simulation results show that the inclined baffles with liquid dam and drainage gaps could drain condensate effectively from tube bundle surfaces and prevent liquid film from entraining into vapor, and that the variable angled trisection helical baffled vertical condenser with dual-threads could greatly improve the condensation heat transfer coefficient up to 35.7% higher than that of the variable spanned segmental baffled one.  相似文献   

8.
One of the techniques used by designers of shell-and-tube heat exchangers when they encounter a potential flow-induced vibration problem is to shift from a tube bundle with segmental baffles to one with double-segmental baffles. This results in a split of the flow into either half of the shell with lower velocities and makes it possible to reduce the unsupported tube span length while keeping below a given allowable pressure drop. Tests were performed as a part of a systematic study of water flow-induced vibration in industrial-size heat exchangers. Results for nine different double-segmental baffled bundle configurations are presented. Comparison of the results with those for similar segmental baffled bundles shows that higher flows can be tolerated without developing damaging flow-induced vibration.  相似文献   

9.
刘振华  廖亮 《太阳能学报》2007,28(2):146-150
提出了一种新型紧凑式顺排光滑管束组成的满液式蒸发换热器。在低压条件下对水平光滑顺排管束的小空间内沸腾强化换热特性进行了实验研究,确认了管距、管位置和运行压力对强化换热性能的影响。实验表明存在一个能得到最大强化换热效果的最佳管距,这一最佳管距接近沸腾气泡的脱离直径。压力对强化换热效果也有重要影响:随着压力降低,强化换热效果也逐步减弱。实验结果对高效节能型蒸发换热器设计提供了设计基础。  相似文献   

10.
Heat transfer coefficients were measured on tube bundles of fundamental layouts including in‐line layouts embedded horizontally in a liquid‐fluidized bed. Tested tube layouts were single tubes, transverse single tube rows, longitudinal single tube rows, and in‐line arranged tube bundles. A total of 7 kinds of particles were used. Comparisons of the experimental data showed a good agreement with the heat transfer correlation developed for staggered layouts, when the average liquid velocity through each tube bundle was used as the reference velocity for the particle Reynolds number. Distribution of the local heat transfer coefficient was also investigated around tubes. © 2009 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20245  相似文献   

11.
En Tian  Ya-Ling He 《传热工程》2018,39(13-14):1166-1178
In this paper, a comprehensive thermo-hydraulic performance evaluation for air flow across the hexagon-like and circular-like staggered pin finned tube bundle heat transfer surfaces has been numerically carried out by adopting the performance evaluation plot of enhanced heat transfer techniques oriented for energy-saving. In addition, the simulation results have also been analyzed from the viewpoints of field synergy principle and entransy dissipation extreme principle. The results indicate that the heat transfers are all enhanced based on identical pressure drop for the hexagon-like and circular-like pin finned tube bundles within the inlet velocity range from 1 m/s to 10 m/s studied. Moreover, the circular-like pin finned tube bundle offers the lowest friction factor increase ratio for the same Nusselt number increase ratio. Furthermore, the synergy between velocity and fluid temperature gradient has been proved again, having inherent consistency with the dissipation of entransy.  相似文献   

12.
This paper presents an improved prediction method for the heat transfer and pressure drop in the shell side of a horizontal shell and tube evaporator. The results from an experimental test program are used in which a wide range of evaporating two-phase shell side flow data was collected from a TEMA E-shell evaporator. The data are compared with shell side heat transfer coefficient and pressure drop models for homogeneous and stratified flow. The comparison suggests a deterioration in the heat transfer data at low mass fluxes consistent with a transition from homogeneous to stratified flow. The pressure drop data suggest a stratified flow across the full test range. A new model is presented that suggests the transition in the heat transfer data may be due to the extent of tube wetting in the upper tube bundle. The new model, which also takes into account the orientation of the shell side baffles, provides a vast improvement on the predictions of a homogenous type model. The new model would enable designers of shell side evaporators/reboilers to avoid operating conditions where poor heat transfer could be expected, and it would also enable changes in process conditions to be assessed for their implications on likely heat transfer performance.  相似文献   

13.
对螺旋角为8°、12°、18°、30°、40°的螺旋折流板换热器进行了壳程传热性能和压力降测试,得到了相应结构下的总传热系数和压力降。然后通过对试验数据的整理分析,并进行曲线回归,得到了不同螺旋角的螺旋折流板换热器换热系数和压降经验计算公式。研究表明,实验条件下,30°螺旋角的螺旋折流板换热器的单位压降传热系数要优于8°、12°、18°、40°螺旋角的螺旋折流板换热器的传热系数。  相似文献   

14.
采用自行编制的程序对N7600凝汽器壳侧蒸汽的流动与传热特性进行了数值计算,得到了壳侧蒸汽的速度与流线、压力、传热系数以及空气浓度等分布图。结果表明:N7600凝汽车器壳侧整体上呈现“汽流向两侧”的流动特点,与设计的初衰基本相符合,在凝汽器的底部流场中存在小的涡流区.说明管束布置还有不合理的地方;凝汽器汽阻为109.5Pa:平均传热系数为3237,15W/m2·K;随着蒸汽的不断凝结,从冷却管束外围到内部的空气浓度逐渐增大。  相似文献   

15.
An improved method combining numerical simulation with multi-objective genetic algorithm (MOGA) was applied to study the flow and heat transfer characteristics of shell-and-tube heat exchanger with helical baffles (STHXsHB). It overcomes the dependence on empirical correlations. The helix angle and overlapped degree of helical baffles were chosen as optimization parameters, while the overall heat transfer coefficient K and pressure drop ΔP of STHXsHB were optimized by MOGA. The results showed that both overall heat transfer coefficient K and pressure drop ΔP varied adversely with the helix angles. The pressure drop ΔP was favorably affected by the overlapped degrees. The overall heat transfer coefficient K did not vary significantly with the overlapped degree. Three optimum configurations were obtained by the MOGA to maximize the overall heat transfer coefficient K and minimize the shell-side pressure drop ΔP. Compared with the original heat exchanger, the overall heat transfer coefficient K increased averagely by 28.3%, while the average pressure drop reduced averagely by 19.37%.  相似文献   

16.
为研究半圆柱空间异形孔板换热器的流动与传热特性,建立换热器简化物理模型,运用ANSYS软件建立CFD模型进行数值模拟,分析了开孔形状与板间距的影响,并对比了半圆柱空间异形孔板换热器与弓形板换热器的联系与区别。研究结果表明:半圆柱异形孔板换热器壳侧流体呈纵向流动,壳侧流体通过孔隙形成射流冲刷管壁,具有强化传热作用;板间距一定,开孔面积相近时,开孔形状对壳侧压降的影响较小,对换热性能的影响稍大;板间距越小壳侧换热系数越高但其综合性能指标越小;圆头三角孔板换热器在板间距30 mm时的壳侧换热系数比40及50 mm方案分别高5.62%,10.06%,综合性能指标低1.44%,2.07%;异形孔板换热器的综合性能指标比弓形折流板换热器平均约高27.89%。  相似文献   

17.
Flow regimes influence the heat and mass transfer processes during two-phase flow, implying that any statistically accurate and reliable prediction of heat transfer and pressure drop during flow condensation should be based on the analysis of the prevailing flow pattern. Many correlations for heat transfer coefficient and pressure drop during flow condensation completely ignored flow regime effects and treated flows as either annular or non-stratified flow or as stratified flow. This resulted in correlations of poor accuracy and limited validity and reliability. Current heat transfer coefficient, pressure drop, and void fraction models are based on the local flow pattern, though, resulting in deviations of around 20% from experimental data. There are, however, several inconsistencies and anomalies regarding these models, which are discussed in this paper. A generalized solution methodology for two-phase flow problems still remains an elusive goal, mainly because gas-liquid flow systems combine the complexities of turbulence with those of deformable vapor-liquid interfaces. The paper focuses on the state of the art in correlating flow condensation in micro-fin tubes and proposes flow regime-based correlations of heat transfer coefficient and pressure drop for refrigerant condensation in smooth, helical micro-fin, and herringbone micro-fin tubes.  相似文献   

18.
A numerical study on the effect of the effect of elliptical and flattened tube bundle geometry on the convective heat transfer and pressure drop is presented in this article. The analysis has been carried out to evaluate the performance of these bundle geometries in the design of a compact and effective single phase shell and tube heat exchanger. The temperature, velocity, and pressure drop profiles are obtained from solving the mass, momentum, and energy conservation equations. The comparison is made for inline and staggered bundle with different pitch to diameter ratio and inlet velocity for elliptical and flattened tubes. The pitch to diameter ratio is varied from 1.25 to 2.5 for Reynolds number ranging from 200 to 2000 which is in the laminar flow region. The heat transfer coefficient over the staggered and inline tube bundle decrease with an increase in pitch. The same kind of variation is also observed for the pressure drop in the case of both elliptical and flattened tube bundle. The study shows that the transverse pitch with respect to cross flow affects more than the longitudinal pitch.  相似文献   

19.
Boiling heat transfer of R-134a on a porous, plasma-coated tube bundle was investigated experimentally to determine the effects of the number of tube rows and the total tube number. The bundle consists of up to four tubes with a pitch-to-diameter-ratio of 1.33. Heat transfer coefficients for a single tube with a porous copper coating were up to four times higher than for a smooth tube. Observations showed that the plasma coating enhanced the heat transfer coefficient in tube bundles as well. The bundle factor of the coated tube bundle showed a similar, slightly increased trend as the smooth tube bundles. The enhancement effect of the coated tubes decreases to a certain extent with an increasing heat flux and decreasing saturation temperature. However, it is significantly less pronounced than trends that have been reported from other investigations. The aim of a stable enhanced coating was confirmed by long-term experiments with steady results.  相似文献   

20.
This study investigates the thermal-flow performance characteristics of an evaporative cooler. The derivation of the Poppe [1] and Merkel [2] analysis for evaporative coolers are presented and discussed. Performance tests were conducted on an evaporative cooler consisting of 15 tube rows with 38.1 mm outer diameter galvanized steel tubes arranged in a 76.2 mm triangular pattern. From the experimental results, correlations for the water film heat transfer coefficient, air–water mass transfer coefficient and air-side pressure drop are developed. The experimental tests show that the water film heat transfer coefficient is a function of the air mass velocity, deluge water mass velocity as well as the deluge water temperature, while the air–water mass transfer coefficient is a function of the air mass velocity and the deluge water mass velocity. It was found that the correlations obtained for the water film heat transfer coefficient and the air–water mass transfer coefficient compare well with the correlations given by Mizushina et al. [3]. Relatively little published information is available for predicting the air-side pressure drop across deluged tube bundles. The present study shows that the pressure drop across the bundle is a function of the air mass velocity and the deluge water mass velocity.  相似文献   