首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeThe purpose of this study was to evaluate the complexity and effectiveness of fitting bitoric rigid gas permeable contact lenses (RGPCLs), compared to spherical RGPCLS, when used in the correction of high amounts of post-penetrating keratoplasty astigmatism.MethodsRecords of post-penetrating keratoplasty (PKP) patients being managed with bitoric RGPCLs were compared to controls (post-PKP patients managed with spherical RGPCLs). Factors that were analyzed included the number of diagnostic RGPCLs used to assess the initial fit, the number of RGPCLs ordered to finalize the fit and the number of total doctor visits to finalize the fit.ResultsFourteen eyes of 14 patients satisfied the study criteria. The average amount of total astigmatism in this study group was 10.0 D ± 5.0 compared to the control group which was 3.3 D ± 2.6. The number of diagnostic RGPCLs used for the study group was 1.2 ± 0.4 compared to 1.0 ± 0.0 for the control group. The mean number of contact lenses ordered to complete the fitting for the study group was 1.9 ± 0.7 compared to the control which was 2.1 ± 0.8. The study group presented for an average of 6.3 ± 1.6 visits whereas the control group presented for 4.9 ± 1.1 visits. Contact lens corrected acuity for the study group was 0.101 ± 0.11 (20/25) compared to the control group 0.08 ± 0.12 (20/24).ConclusionsThe complexity of fitting bitoric RGPCLs was found to be similar to fitting spherical RGPCLs on post-PKP eyes and the visual outcomes were not different.  相似文献   

2.
PurposeTo compare conventional method of contact lens fitting with software based contact lens fitting using Medmont corneal topographer in eyes with nebular and macular corneal scars.MethodsFifteen participants who were diagnosed with nebular and macular scars were fitted with rigid gas permeable lenses using conventional method of contact lens fitting. During the lens dispensing visit, participants underwent Medmont corneal topography. Agreement between the two methods of contact lens fitting was studied.ResultsParameters of contact lenses which were concluded using conventional method was compared to that of software based fitting. Mean difference in base curve of contact lens between the two methods was 0.094 mm ± 0.147 mm (95% CI: +0.383 to −0.194). Mean difference in diameter of contact lens between the two methods was 0.16 mm ± 0.172 mm (95% CI: +0.497 to −0.177). Contact lens parameters that were achieved using two different methods of fitting showed good correlation. Correlation coefficients, as comparison of two methods in base curve and diameter were 0.96 (P < 0.05) and 0.94 (P < 0.05), respectively.ConclusionSoftware based contact lens fitting would be useful for contact lens practitioners to predict initial base curve of contact lens in corneal scars.  相似文献   

3.
PurposeTo investigate the differences of functional visual acuity (FVA) and high order aberrations (HOAs) in relation to tinted and clear hydrogel soft contact lens (SCL) wear.MethodsA prospective comparative study was performed in 16 eyes of 16 healthy volunteers. Dynamic visual acuity (using a FVA measurement system) and higher-order aberrations (using a wavefront sensor) were compared in subjects wearing two types of soft contact lenses: 1-day Acuvue® (Vistakon, Jacksonville, FL) clear and the 1-day Acuvue® DefineTM (Vistakon, Jacksonville, FL) tinted lens. The blink rates were recorded during FVA testing. The correlation between the difference of HOAs and differences in FVA values was analyzed.ResultsThe mean LogMAR FVA scores with clear and tinted SCLs were 0.07 ± 0.13 and 0.14 ± 0.17 (P < 0.05). The mean blink frequencies with clear and tinted SCL wear were 18.4 ± 8.3 and 25.3 ± 4.7 blinks/min (P < 0.05). Both 3rd-order aberrations and total HOAs showed statistically significant differences between the two types of soft contact lenses for 6 mm pupil measurements (P < 0.05). A significant positive linear correlation was observed between ΔHOAs and ΔLogMAR FVA for 6 mm pupil measurements (R = 0.53, P = 0.04).ConclusionsTinted contact lens wear appears to induce a reduction in optical quality. Functional visual acuity measurement is a useful procedure to study the changes of visual performance and quality in tinted contact lens wear.  相似文献   

4.
PurposeTo assess and compare the base curve (BC) of rigid gas permeable contact lens (RGP) that were calculated by FITSCAN using corneal topography (Orbscan IIz) and the diagnostic contact lens fitting method in keratoconus eyes.Materials and methodsA prospective comparative study of 85 keratoconus eyes was conducted. Two masked observers calculated the contact lens parameters of RGP lens by diagnostic fitting method and using FITSCAN technology. The base curves calculated by two methods were compared using Wilcoxon signed rank test and agreement between two methods were analysed using Bland–Altman plot.ResultsEighty-five eyes from 55 keratoconus patients were included in the study. The mean age was 17.63 ± 2.78 (range: 12–23) years and among them 46 were males. The keratoconus was graded into mild, moderate and severe based on average keratometry values. The base curve calculated by the FITSCAN is on average 0.22 mm higher than that calculated by diagnostic method (P value <0.0001, 95% CI = 0.155, 0.245, Wilcoxon signed rank test) and the bias between the two methods was found to be 2.7% (Bland–Altman plot), indicating systematic bias between the two modalities. By single linear regression analysis, the base curve of RGP contact lens could calculated by using the formula, base curve (BC) = (FITSCAN calculated BC × 0.86563) + 0.78738.ConclusionOur study showed that selecting the BC of the initial trial lens 0.22 mm steeper than the FITSCAN calculated base curve, may help to reduce the complexity of RGP contact lens fitting in keratoconus.  相似文献   

5.
PurposeTo investigate usage of soft contact lens (SCL) on post-operative pain relief and daily, activity due to pterygium surgery.MethodsAutograft pterygium surgery was performed to 63 eyes of 63 patients. After surgery in 30, eyes of 30 patients in group-1, SCL was placed on the cornea. In 33 patients of group-2, antibiotic, pomade was applied and tightly covered with bandage. Follow-up visits were performed on 24th and, 48th h after the surgery. Re-epithelization time and pain scores were compared.ResultsPatients’ 24th h pain score was 2.96 ± 0.76 in group-1, and 4.15 ± 0.75 in group-2. The mean, pain score for 48 h was 1.66 ± 0.66 in group-1, and 2.96 ± 0.68 in group-2. Patients’ pain scores for, both 24th h and 48th h were lower in group-1 (p < 0.01). The mean re-epithelization times in, group 1 and 2 were 48 and 56.7 h, respectively. Corneal re-epithelization is improved in patients, with SCL compared to group 2.ConclusionSCL seems effective on reducing post-operative pain and eye stinging, and may accelerate, corneal re-epithelization and maintaining daily activities.  相似文献   

6.
ObjectivesTo evaluate the utility of the Rose K2 XL semi-scleral contact lens (Menicon Co. Ltd., Nagoya, Japan) in the management of the irregular cornea.MethodsTwenty-seven subjects (34 eyes) with irregular corneas referred for contact lens fitting were evaluated. A diagnostic trial set was used in the fitting process. Once the trial lens was considered optimal, a final lens was ordered from the manufacturer with the necessary changes in power, edge lift and diameter. We analyzed visual acuity, number of lenses ordered and patients’ ability to wear and handle lenses.ResultsTwenty-three subjects (30 eyes) were fitted with the Rose K2 XL lens. Four subjects (4 eyes) decided not to conclude the fitting process for different reasons. Average logMAR visual acuity without correction and with the lens was 0.82 and 0.09, respectively (p < 0.001). An average of 1.4 ordered lenses (range 1–3) were necessary to achieve the optimal fit. Nineteen eyes (63%) were fitted with the first lens ordered. Three subjects (13%) had problems with lens handling, and three subjects (4 eyes) abandoned the wear of the lenses after three months due to discomfort (3 eyes) and unsatisfactory visual acuity (1 eye), respectively. Follow-up ranged from 6 to 9 months.ConclusionRose K2 XL semi-scleral contact lens provides good visual acuity and comfort in patients with irregular corneas.  相似文献   

7.
8.
IntroductionAccurate corneal measurements are crucial in corneal refractive surgery (CRS) to ensure successful outcomes. Soft contact lens (SCL) wear may result in changes to corneal curvature and structure. United States Food and Drug Administration (FDA) pre-operative guidelines recommend that prior to CRS, SCL wearers cease SCL wear for “at least two weeks before examination and treatment” [1]. Corneal curvature changes induced by SCL wear may take longer than two weeks to resolve.PurposeTo examine the effect of SCL wear on corneal curvature before and following two weeks SCL wear cessation. To explore the possible impact of different SCL materials and years of SCL wear.MethodsRetrospective data analysis, between a group of SCL wearers (SCL: n = 45); and a non-contact lens control group (NCL: n = 45). Corneal curvature parameters were measured using the Pentacam (Oculus, Germany), before and following two weeks cessation of SCL wear.ResultsNo significant differences in keratometry or Sagittal radius of curvature between SCL and NCL groups prior to or following SCL cessation. Tangential radius of curvature showed significant inferior steepening for the SCL group prior to SCL cessation (SCL vs. NCL; 7.77 ± 0.30 mm vs. 7.90 ± 0.30 mm; p = 0.04). Following two weeks cessation of SCL wear this appeared to have resolved.ConclusionsTwo weeks cessation of SCL wear appears sufficient for resolution of corneal curvature changes with modern SCL materials and years of SCL wear. However, further studies with longer lens deprivation periods are required to ensure stability for all SCL wearing patients.  相似文献   

9.
PurposeTo assess the feasibility of fitting a lathed soft toric contact lens (STCL) after the implant of intrastromal corneal ring segments (ICRSs) to treat keratoconus.MethodsSix months after ICRS implantation, 47 eyes of 47 patients (18–45 years) were fitted with a STCL. In each eye, we determined refractive error, uncorrected (UDVA) and corrected distance visual acuity (CDVA), and keratometry and asphericity measures. The outcome of STCL fitting was defined according to CDVA as successful (≤0.2 logMAR) or unsuccessful (>0.2 logMAR). Patients in the unsuccessful group were refitted with a piggy-back (PB) system. The above variables and the change in CDVA observed after STCL and PB lens fitting from spectacle CDVA were compared in the two groups.ResultsSTCL fitting was successful in 75%, 66.66% and 0% of the ICRS implanted eyes with stages I–III keratoconus, respectively. Spectacle-CDVA was 1.5 lines better and mean corneal power was 3.62D lower in the successful STCL group. In this group, the difference in cylinder axis between spectacles and STCL was 24.25° lower. PB refitting achieved a PB-CDVA ≤0.2 logMAR in all cases. A similar difference in the CDVA change achieved by contact lenses versus spectacles was observed in the successful STCL and PB refitted groups.ConclusionSTCL fitting is a feasible option in a large proportion of patients implanted with ICRS. When these lenses are unsatisfactory, a PB system is a good alternative.  相似文献   

10.
ObjectivesThe study aimed to assess the possible effects of corneal cross-linking (CXL) on contact lens (CL) fitting in patients with progressive keratoconus who initially had CL intolerance.MethodsA retrospective review was performed of the medical records of patients who had stopped CL wear due to discomfort prior to CXL and who were fitted with CLs after CXL. All eyes were evaluated pre- and 1, 6, 12, 24 months postoperatively. Data collected included pre- and post-CXL refraction, corneal topographic data, uncorrected visual acuity, and best-corrected visual acuity (BCVA). CL comfort was evaluated using the Likert scale post-CXL.ResultsA total of 20 eyes from 14 patients were included in the study. Preoperative Kmax values significantly decreased by 2.8 D at 6 months and by 4.1 D at 12 months after CXL (p < 0.001 for both). CLs were prescribed on average 12 ± 2.5 months after CXL. The mean duration of successful CL wear was 10.4 ± 2.8 months during the follow-up period. Subjective CL comfort scores were satisfactory post-CXL.ConclusionCXL not only halts the progression of keratoconus but may also improve CL tolerance by providing a more regular shaped cornea in these patients. Ongoing corneal topographic changes in the late postoperative period after CXL may have a positive effect on CL fitting.  相似文献   

11.
PurposeTo assess the corneal endothelial cell density (ECD) in keratoconus patients with no history of contact lens use.SettingYuzuncu Yil University, School of Medicine and Van Training and Research Hospital, Department of Ophthalmology, Van, Turkey.DesignCross-sectional controlled study.MethodsThe eyes of 65 patients with the diagnosis of keratoconus with no history of contact lens wear and the eyes of 40 healthy controls were prospectively examined using the Heidelberg Retinal Tomography Rostock Cornea Module (HRT3/RCM). The average ECD from the two groups were then compared.ResultsOf the cases with keratoconus, 44 (67.7%) were men and 21 (32.3%) were women. The mean age was 20.9 ± 6.8 (range = 10–41) years. Of the controls, 28 (70%) were men and 12 (30%) were women. The mean age was 23.9 ± 5.8 (range = 14–35) years. Of the 65 eyes with keratoconus, 19 (29.2%) had mild keratoconus, 21 (32.3%) had moderate keratoconus, and 25 (38.5%) had severe keratoconus. The mean ECD was 2731.6 ± 303.2 cells/mm2 in cases with keratoconus and 2664.9 ± 319.5 cells/mm2 in controls. There was no difference between the densities (unpaired t-test, P = 0.4). No significant relationships were found between the ECD data and central corneal thickness or steepest keratometric.ConclusionsEndothelial cell density was unaltered in keratoconic patients without a history of contact lens use when compared with healthy controls. Change in ECD is independent from the central corneal thickness and the stage of keratoconus.  相似文献   

12.
PurposeTo investigate the accuracy of measuring intraocular pressure over a silicone hydrogel contact lens using Goldmann applanation tonometry in eyes with glaucoma.MethodsThis was a prospective, randomized study and enrolled 28 patients (28 right eyes) with primary open angle glaucoma. Intraocular pressure was taken with and without a silicone hydrogel contact lens (−0.50 D), in situ (using Goldmann applanation tonometry), in a randomized order of measurements. Statistical analysis was performed using paired t-test and Bland–Altman plot.ResultsThe mean difference (± standard deviation) found between intraocular pressure measurement without (mean 16.7 ± 3.2 mmHg) and with (mean 17.3 ± 3.0 mmHg) contact lens was found to be −0.57 ± 2.3 mmHg (95% confidence interval, −1.5 to 0.3). No significant statistical difference was found between the two groups with paired t-test (p = 0.19). The Bland Altman plot showed some evidence of increasing variability of differences between two measures of intraocular pressure, with increasing intraocular pressure. The 95% limits of agreement of the Bland Altman plot were unacceptably large (−5 mmHg to 3.9 mmHg).ConclusionAgreement between Goldmann applanation tonometry with and without contact lenses seems to be poor in patients with glaucoma, especially for high intraocular pressure.  相似文献   

13.
PurposeTo investigate the efficacy and safety of a fenestrated and channelled soft contact lens (F-SCL) compared to a standard and non-fenestrated soft contact lens (S-SCL) in experienced soft contact lens (SCL) wearers.MethodsThis was a randomised, crossover, single-blinded (subject), and multicentre clinical trial. Sixteen experienced SCL wearers were randomly divided into two groups (FS and SF). The FS group first wore F-SCLs followed by S-SCLs, each for 10 days, separated by a 1-week washout period, whereas the SF group wore the S-SCLs first and crossed over to F-SCLs in the same manner. The F-SCLs were designed with three equally spaced, symmetrical fenestrations and a partial-thickness, connecting, circumferential channel on the back surface of the mid-periphery of the lens. Measurement of central corneal thickness using ultrasonic pachymetry was performed on the day of screening, after the 1-week washout period, and after 10 days of wearing each kind of lens, based on which central corneal swelling was calculated and compared. One eye in each subject was chosen at random for analysis.ResultsCentral corneal swelling was 1.92 ± 1.73% vs. 5.26 ± 2.14% in F-SCLs vs. S-SCLs wearers, which was statistically significant (P < 0.001). There was no significant difference between the groups in terms of SCL-corrected visual acuity or SCL-related adverse events.ConclusionThe use of F-SCLs led to reduced corneal swelling compared to S-SCLs. The newly incorporated features appear to improve tear mixing and thereby the oxygen supply to the cornea, which results in reduced corneal oedema.  相似文献   

14.
PurposeTo compare the efficacy, safety and postoperative pain of mechanical versus transepithelial photorefractive keratectomy (PRK) techniques.SettingCornea and refractive surgery subspecialty.DesignProspective clinical trial.MethodsThis prospective comparative study included 84 eyes of 42 patients with myopia who received mechanical PRK (m-PRK) in 1 eye and transepithelial PRK (t-PRK) in the contralateral eye. The mean patient age was 28.5 ± 6.3 years (range 20–46 years). Postoperative uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refractions, postoperative epithelial healing time, surgical time, postoperative pain rating and corneal haze were recorded.ResultsAt week 1, statistically the UDVA was significantly better in the t-PRK eyes; however, at 3 months, similar refractive stability was achieved in both groups. The mean spherical equivalent (SE) decreased from −2.44 ± 1.00 D (m-PRK eyes) and −2.88 ± 1.24 D (t-PRK eyes) at baseline to −0.19 ± 0.38 D and −0.30 ± 0.40 D, respectively, after 1 year. Surgical time was 98.6 ± 9.8 s in m-PRK eyes and 58.0 ± 6.4 s in t-PRK eyes. On postoperative days 1 and 3, using the global assessment rating, 81% of mPRK eyes that had pain, reported more pain than that reported for the tPRK eyes. In addition, m-PRK treated eyes demonstrated higher mean pain scores based on the 11-point numerical rating scale and Visual Analogue Scale (VAS). The mean time to complete epithelial healing was 2.19 ± 0.39 days (t-PRK) and 3.76 ± 0.43 days (m-PRK).Conclusiont-PRK for mild-to-moderate myopia was more comfortable than conventional m-PRK; patients had less pain, and faster healing time.  相似文献   

15.
PurposeThe aim of this study was to compare central corneal thickness (CCT) between corneas of normal healthy eyes (cNHE), corneas of eyes that had undergone cataract surgery by clear corneal phacoemulsification with implantation of an intracapsular intraocular lens (cIOL), corneal grafts after penetrating keratoplasty (gPK) and corneas of long-term soft contact lens wearers (cCL).MethodsThe study design was a consecutive cross-sectional trial. CCT was measured using rotating Scheimpflug camera (Pentacam, software version 1.16r04) in 80 cNHE, 79 cIOL, 46 gPK and 78 cCL. Analysis of variance (one-way ANOVA) was performed to compare differences of mean values between these four groups. Pearson's or Spearman's correlation coefficient (r) was determined between CCT value and age, follow up time after penetrating keratoplasty (timePK) or contact lens wearing time (timeCL).ResultsMeans of CCT measurements were comparable between cNHE (mean CCT ± standard deviation, 554 ± 36 μm), cIOL (551 ± 40 μm) and gPK (534 ± 52 μm) as determined by one-way ANOVA. Mean CCT values in cCL (537 ± 37 μm) were statistically significantly lower in comparison to cNHE (p = 0.026, 95% CI = 1.43–31.44). There was no linear correlation between age and CCT values of cNHE and cIOL (p = 0.841, r = −0.031 and p = 0.931, r = 0.011, respectively). No linear relationship was determined between CCT values of cCL and timeCL (p = 0.315, r = −0.125). CCT values of gPK did not correlate with timePK (p = 0.738, r = 0.054).ConclusionsThe data reported here indicate that in the same statistical model among CCT values of cNHE, cIOL and gPK only long-term soft contact lenses (CL) wearer have significantly lower CCT measurements.  相似文献   

16.
PurposeTo investigate the rate of progression of keratoconus in patients wearing pancorneal toric edge rigid gas-permeable contact lenses (pancorneal RGP-CL) compared to non-pancorneal RGP-CL. We also evaluated alterations in anterior chamber parameters with the progression of keratoconus and investigated the location of the cone in eyes with keratoconus.MethodsThe current study was a retrospective study including patients with clinically evident keratoconus from the outpatient clinic from the Department of Ophthalmology of the Erasmus Medical Center, Rotterdam, the Netherlands. Medical history and contact lens characteristics were documented. All participants underwent ophthalmic examination including corneal topography. Corneal topography was repeated at one of the consecutive visits of the patient. Patients were divided into two groups: those wearing pancorneal RGP-CL and those wearing other contact lens types. As a measure of progression of keratoconus differences in corneal topography parameters between both groups were compared.ResultsA total of 82 patients were included of which 42 had follow-up (mean 17.8 months) data. We found a significant difference in progression between eyes fitted with and without pancorneal RGP-CL (K-flat: p = 0.09, K-steep: p = 0.02, K-mean: p = 0.02, and K-minimum: p = 0.04). Compared with eyes fitted without pancorneal RGP-CL no significant difference in K-values was found for eyes fitted with pancorneal RGP-CL during follow-up. Furthermore, a significant decrease in anterior chamber volume (p < 0.001) and corneal volume (p = 0.008) was found during follow-up. In 86.6% the location of the cone was located infero-temporal.ConclusionsPancorneal RGP-CL have a better effect on stabilizing progression of keratoconus than non-pancorneal RGP-CL. The finding of an infero-temporal location of the cone in keratoconic corneas may improve results of contact lens fitting and surgical management.  相似文献   

17.
ObjectiveTo evaluate the efficacy of contact lenses in visual rehabilitation of a series of patients with corneal scars/opacities.MethodRetrospective review of case records of 158 patients (n = 162 eyes) with poor vision subsequent to corneal scar/opacity, who underwent contact lens fitting, was done. Primary outcome assessed was quantum of additional improvement in vision with rigid gas permeable (RGP) or soft lenses over spectacles. Success was defined as visual improvement of ≥2 lines over that of spectacles and/or improvement of vision to ≥20/60 (LogMAR 0.48).ResultsRigid gas permeable lenses were fitted in 137 eyes and soft contact lenses in 25 eyes. Lenses were successful in improving visual acuity by two or more lines over that of spectacles in 70% eyes (113 of 162 eyes), of which RGP lens accounted for 85% (96 of 113 eyes). Alternative outcome of success was defined as attainment of reasonable functional vision of >20/60 (LogMAR 0.48). This could be achieved in 65% cases (105 of 162 eyes) of which 83% (88 eyes) were with use of RGP lenses. Almost one-fourth (23.4%) patients were children less than 15 years old. Soft contact lenses were attempted in 25 instances, where RGP lens could not be fitted and were successful in 17 (68%) of these. All these 17 patients were aphakes.ConclusionsRehabilitation of corneas with visually disabling corneal opacities is possible with usage of appropriate contact lenses even in young children.  相似文献   

18.
PurposeTo evaluate the efficacy of two silicone hydrogel (SiH) contact lenses, approved for continuous wear for one week, following photorefractive keratectomy (PRK).MethodsForty seven myopic patients (94 eyes) undergone bilateral PRK were enrolled in this prospective, double-masked, comparative study. One eye of each patient was fitted with a Lotrafilcon B lens (Ciba Vision, Duluth, US; 30-day recommended replacement) whereas the fellow eye was fitted with an Asmofilcon A lens (Menicon, Nagoya, Japan; 14-day recommended replacement). Epithelial defect size was assessed using slit lamp biomicroscopy on the day of surgery and at days 1–4 post-operatively. Uncorrected and best-corrected visual acuity and retinal straylight (C-Quant, Oculus Optigerate, Germany) were evaluated pre-operatively and one month post-operatively.ResultsAverage epithelial defect size for Asmofilcon A and Lotrafilcon B was 25.5 ± 11.0 mm2 vs. 27.1 ± 9.9 mm2 at day 1 (p = 0.007) and 6.3 ± 7.0 mm2 vs. 9.2 ± 9.5 mm2 at day 2 (p = 0.012) post-operatively. Re-epithelialization at day 3 was completed in 87.2% of the eyes fitted with Asmofilcon A lenses, compared to 74.5% with Lotrafilcon B lenses (p = 0.012). At the 3rd post-operative day 29.8% of re-epithelialized eyes showed irregular suture with Lotrafilcon B, compared to 12.8% eyes with Asmofilcon A lenses (p < 0.001). Finally, no statistically significant differences were found post-operatively between the two lenses retinal straylight (p = 0.98) and best-corrected visual acuity (p = 0.68).ConclusionsSiH lenses can be used as an effective bandage after PRK due to the limited time requested for achieving complete corneal re-epithelialization. Faster and smoother epithelial healing is provided with Asmofilcon A over Lotrafilcon B lenses.  相似文献   

19.
PurposeTo evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes.MethodsTen right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses.ResultsBoth experimental lenses were able to increase significantly the relative peripheral myopic defocus up to −0.50 D in the nasal field and −1.00 D in the temporal field (p < 0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5 mm pupil size (p < 0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p > 0.05).ConclusionsRGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed.  相似文献   

20.
PurposeTo examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations.MethodsScheimpflug imaging was captured before, immediately following and 3 h after a short period (3 h) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear.ResultsSmall but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels 3 h after lens removal. During the 3 h recovery period significant corneal thinning (−13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = −0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean −0.144 ± 0.075 μm, p = 0.02).ConclusionsFlattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号