首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Mass spectrometry imaging (MSI) acquires a grid of spatially resolved mass spectra and provides a molecular landscape of a tissue. This can have a myriad of uses: from basic tissue characterization to a comprehensive pathological diagnosis. We have developed a fast, inexpensive, histology-compatible tissue preparation method for matrix-assisted laser desorption/ionization (MALDI)-MSI, which overcomes current sample preparation-imposed limitations in image resolution. Tissue sections are prepared via simultaneous fixation and matrix deposition. This is accomplished by incorporating the MALDI matrix into solvents that preserve tissue integrity when applied according to standard histology procedures. This concept was expanded to include multiple histology protocols, thereby enabling analysis to be tailored to a variety of biomolecules and tissue types.  相似文献   

2.
An infrared laser was used to ablate material from tissue sections under ambient conditions for direct collection on a matrix assisted laser desorption ionization (MALDI) target. A 10 μm thick tissue sample was placed on a microscope slide and was mounted tissue-side down between 70 and 450 μm from a second microscope slide. The two slides were mounted on a translation stage, and the tissue was scanned in two dimensions under a focused mid-infrared (IR) laser beam to transfer material to the target slide via ablation. After the material was transferred to the target slide, it was analyzed using MALDI imaging using a tandem time-of-flight mass spectrometer. Images were obtained from peptide standards for initial optimization of the system and from mouse brain tissue sections using deposition either onto a matrix precoated target or with matrix addition after sample transfer and compared with those from standard MALDI mass spectrometry imaging. The spatial resolution of the transferred material is approximately 400 μm. Laser ablation sample transfer provides several new capabilities not possible with conventional MALDI imaging including (1) ambient sampling for MALDI imaging, (2) area to spot concentration of ablated material, (3) collection of material for multiple imaging analyses, and (4) direct collection onto nanostructure assisted laser desorption ionization (NALDI) targets without blotting or ultrathin sections.  相似文献   

3.
A new matrix-assisted laser desorption/ionization (MALDI) time-of-flight/time-of-flight (TOF/TOF) high-resolution tandem mass spectrometer is described for sequencing peptides. This instrument combines the advantages of high sensitivity for peptide analysis associated with MALDI and comprehensive fragmentation information provided by high-energy collision-induced dissociation (CID). Unlike the postsource decay technique that is widely used with MALDI-TOF instruments and typically combines as many as 10 separate spectra of different mass regions, this instrument allows complete fragment ion spectra to be obtained in a single acquisition at a fixed reflectron voltage. To achieve optimum resolution and focusing over the whole mass range, it may be desirable to acquire and combine three separate sections. Different combinations of MALDI matrix and collision gas determine the amount of internal energy deposited by the MALDI process and the CID process, which provide control over the extent and nature of the fragment ions observed. Examples of peptide sequencing are presented that identify sequence-dependent features and demonstrate the value of modifying the ionization and collision conditions to optimize the spectral information.  相似文献   

4.
Matrix sublimation has demonstrated to be a powerful approach for high-resolution matrix-assisted laser desorption ionization (MALDI) imaging of lipids, providing very homogeneous solvent-free deposition. This work presents a comprehensive study aiming to evaluate current and novel matrix candidates for high spatial resolution MALDI imaging mass spectrometry of lipids from tissue section after deposition by sublimation. For this purpose, 12 matrices including 2,5-dihydroxybenzoic acid (DHB), sinapinic acid (SA), α-cyano-4-hydroxycinnamic acid (CHCA), 2,6-dihydroxyacetphenone (DHA), 2',4',6'-trihydroxyacetophenone (THAP), 3-hydroxypicolinic acid (3-HPA), 1,8-bis(dimethylamino)naphthalene (DMAN), 1,8,9-anthracentriol (DIT), 1,5-diaminonapthalene (DAN), p-nitroaniline (NIT), 9-aminoacridine (9-AA), and 2-mercaptobenzothiazole (MBT) were investigated for lipid detection efficiency in both positive and negative ionization modes, matrix interferences, and stability under vacuum. For the most relevant matrices, ion maps of the different lipid species were obtained from tissue sections at high spatial resolution and the detected peaks were characterized by matrix-assisted laser desorption ionization time-of-flight/time-of-flight (MALDI-TOF/TOF) mass spectrometry. First proposed for imaging mass spectrometry (IMS) after sublimation, DAN has demonstrated to be of high efficiency providing rich lipid signatures in both positive and negative polarities with high vacuum stability and sub-20 μm resolution capacity. Ion images from adult mouse brain were generated with a 10 μm scanning resolution. Furthermore, ion images from adult mouse brain and whole-body fish tissue sections were also acquired in both polarity modes from the same tissue section at 100 μm spatial resolution. Sublimation of DAN represents an interesting approach to improve information with respect to currently employed matrices providing a deeper analysis of the lipidome by IMS.  相似文献   

5.
Imaging mass spectrometry (MS) is a powerful technique for mapping the spatial distributions of a wide range of chemical compounds simultaneously from a tissue section. Co-localization of the distribution of individual molecular species, including particular lipids and proteins, and correlation with the morphological features of a single tissue section are highly desirable for comprehensive tissue analysis and disease diagnosis. We now report on the use, in turn, of desorption electrospray ionization (DESI), matrix assisted laser desorption ionization (MALDI), and then optical microscopy to image lipid and protein distributions in a single tissue section. This is possible through the use of histologically compatible DESI solvent systems, which allow for sequential analyses of the same section by DESI then MALDI. Hematoxylin and eosin (H&E) staining was performed on the same section after removal of the MALDI matrix. This workflow allowed chemical information to be unambiguously matched to histological features in mouse brain tissue sections. The lipid sulfatide (24:1), detected at m/z 888.8 by DESI imaging, was colocalized with the protein MBP isoform 8, detected at m/z 14117 by MALDI imaging, in regions corresponding to the corpus callosum substructure of the mouse brain, as confirmed in the H&E images. Correlation of lipid and protein distributions with histopathological features was also achieved for human brain cancer samples. Higher tumor cell density was observed in regions demonstrating higher relative abundances of oleic acid, detected by DESI imaging at m/z 281.4, and the protein calcyclin, detected by MALDI at m/z 10085, for a human glioma sample. Since correlation between molecular signatures and disease state can be achieved, we expect that this methodology will significantly enhance the value of MS imaging in molecular pathology for diagnosis.  相似文献   

6.
We have achieved enhanced lipid imaging to a ~10 μm spatial resolution using negative ion mode matrix assisted laser desorption ionization (MALDI) imaging mass spectrometry, sublimation of 2,5-dihydroxybenzoic acid as the MALDI matrix, and a sample preparation protocol that uses aqueous washes. We report on the effect of treating tissue sections by washing with volatile buffers at different pHs prior to negative ion mode lipid imaging. The results show that washing with ammonium formate, pH 6.4, or ammonium acetate, pH 6.7, significantly increases signal intensity and number of analytes recorded from adult mouse brain tissue sections. Major lipid species measured were glycerophosphoinositols, glycerophosphates, glycerolphosphoglycerols, glycerophosphoethanolamines, glycerophospho-serines, sulfatides, and gangliosides. Ion images from adult mouse brain sections that compare washed and unwashed sections are presented and show up to 5-fold increases in ion intensity for washed tissue. The sample preparation protocol has been found to be applicable across numerous organ types and significantly expands the number of lipid species detectable by imaging mass spectrometry at high spatial resolution.  相似文献   

7.
A multiple ionization mass spectrometry strategy is presented based on the analysis of human serum extracts. Chromatographic separation was interfaced inline with the atmospheric pressure ionization techniques electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (+) and negative (-) ionization modes. Furthermore, surface-based matrix-assisted laser desorption/ionization (MALDI) and desorption ionization on silicon (DIOS) mass spectrometry were also integrated with the separation through fraction collection and offline mass spectrometry. Processing of raw data using the XCMS software resulted in time-aligned ion features, which are defined as a unique m/z at a unique retention time. The ion feature lists obtained through LC-MS with ESI and APCI interfaces in both +/- ionization modes were compared, and unique ion tables were generated. Nonredundant, unique ion features, were defined as mass numbers for which no mass numbers corresponding to [M + H](+), [M - H](-), or [M + Na](+) were observed in the other ionization methods at the same retention time. Analysis of the extracted serum using ESI for both (+) and (-) ions resulted in >90% additional unique ions being detected in the (-) ESI mode. Complementing the ESI analysis with APCI resulted in an additional approximately 20% increase in unique ions. Finally, ESI/APCI ionization was combined with fraction collection and offline-MALDI and DIOS mass spectrometry. The parts of the total ion current chromatograms in the LC-MS acquired data corresponding to collected fractions were summed, and m/z lists were compiled and compared to the m/z lists obtained from the DIOS/MALDI spectra. It was observed that, for each fraction, DIOS accounted for approximately 50% of the unique ions detected. These results suggest that true global metabolomics will require multiple ionization technologies to address the inherent metabolite diversity and therefore the complexity in and of metabolomics studies.  相似文献   

8.
A hybrid quadrupole orthogonal time-of-flight mass spectrometer optimized for matrix-assisted laser desorption ionization (MALDI) and electrospray ionization has been equipped with a C 60 cluster ion source. This configuration is shown to exhibit a number of characteristics that improve the performance of traditional time-of-flight secondary ion mass spectrometry (TOF-SIMS) experiments for the analysis of complex organic materials and, potentially, for chemical imaging. Specifically, the primary ion beam is operated as a continuous rather than a pulsed beam, resulting in up to 4 orders of magnitude greater ion fluence on the target. The secondary ions are extracted at very low voltage into 8 mTorr of N 2 gas introduced for collisional focusing and cooling purposes. This extraction configuration is shown to yield secondary ions that rapidly lose memory of the mechanism of their birth, yielding tandem mass spectra that are identical for SIMS and MALDI. With implementation of ion trapping, the extraction efficiency is shown to be equivalent to that found in traditional TOF-SIMS machines. Examples are given, for a variety of substrates that illustrate mass resolution of 12,000-15,600 with a mass range for inorganic compounds to m/ z 40,000. Preliminary chemical mapping experiments show that with added sensitivity, imaging in the MS/MS mode of operation is straightforward. In general, the combination of MALDI and SIMS is shown to add capabilities to each technique, providing a robust platform for TOF-SIMS experiments that already exists in a large number of laboratories.  相似文献   

9.
Oligonucleotide ions have been detected using matrix-assisted laser desorption/ionization (MALDI) under nonresonant laser irradiation of the sample. When mass resolution was not limited by adduct attachment to the analyte ions, the nonresonant MALDI spectra demonstrated better resolution than the spectra acquired with resonant ultraviolet irradiation. We found that preparation of thin-film samples on absorbing substrate surfaces was critical for the success of NR-MALDI. The possible acoustic mechanisms of ion formation and desorption are discussed.  相似文献   

10.
In-source decay (ISD) fragmentation as combined with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry allows protein sequencing directly from mass spectra. Acquisition of MALDI-ISD mass spectra from tissue samples is achieved using an appropriate MALDI matrix, such as 1,5-diaminonaphthalene (DAN). Recent efforts have focused on combining MALDI-ISD with mass spectrometry imaging (MSI) to provide simultaneous sequencing and localization of proteins over a thin tissue surface. Successfully coupling these approaches requires the development of new data analysis tools, but first, investigating the properties of MALDI-ISD as applied to mixtures of protein standards reveals a high sensitivity to the relative protein ionization efficiency. This finding translates to the protein mixtures found in tissues and is used to inform the development of an analytical pipeline for data analysis in MALDI-ISD MS imaging, including software to identify the most pertinent spectra, to sequence protein mixtures, and to generate ion images for comparison with tissue morphology. The ability to simultaneously identify and localize proteins is demonstrated by using the analytical pipeline on three tissue sections from porcine eye lens, resulting in localizations for crystallins and cytochrome c. The variety of protein identifications provided by MALDI-ISD-MSI between tissue sections creates a discovery tool, and the analytical pipeline makes this process more efficient.  相似文献   

11.
Automation of data collection in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry using a correlative analysis algorithm is demonstrated. This algorithm was employed to compensate for mass spectral jittering in MALDI data collection (e.g., peak shifts along the m/z axis, signal intensity deviations, etc.). Several important parameters for performing correlative analysis, such as the minimum correlation coefficient to be used and number of mass spectra to acquire prior to correlation, have been investigated and optimized. In addition, the correlation algorithm improved mass resolution of low- and high-molecular-weight compounds by as much as a factor of 4. Signal reproducibility in MALDI quantitative analysis also is improved when correlation is employed for data collection. This data collection algorithm can be used in conjunction with other instrumental optimization programs to allow for fully automated MALDI analysis, which is required for the routine applications carried out in many analytical laboratories.  相似文献   

12.
The use of an intermediate-pressure matrix-assisted laser desorption/ionization (IP-MALDI) source working at 0.17 Torr on a linear ion trap (LIT) was investigated for the analysis of tissue specimens, in particular, spinal cord sections. MALDI, with 2,5-dihydroxybenzoic acid (DHB) as the matrix, was employed for the detection of phospholipids. The matrix was applied to the tissue using electrospray to avoid analyte migration. The results indicate that analyzing tissue specimens at nontraditional MALDI vacuum pressures is possible. Coupling MALDI to an LIT permits the use of MSn, which is critical for the ability to identify compounds desorbed directly from tissue specimens. Using MSn, ions detected from m/z 600-1000 were characterized as phosphatidlycholines, PC. Specifically, using tandem MS, PC ions could be classified as either [M + H]+ or [M + Na]+ because the fragmentation patterns of protonated and sodiated phosphatidlycholines follow different pathways.  相似文献   

13.
The direct profiling of proteins present in tissue sections for several organs of the mouse has been accomplished using matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS). Fresh tissue was sectioned and blotted on a conductive polyethylene membrane. The dried membrane blot was coated with matrix, typically sinapinic acid, and directly analyzed in the mass spectrometer. Generally, well over 100 peptide/protein signals in the 2000-30,000 Da range were observed, with 30-50 having relatively high signal intensities. Analysis of different areas of the same tissue gave remarkably similar mass spectra with greater than 90% homology. However, different parts of a segmented tissue, such as the proximal, intermediate, and distal colon, gave some unique protein signals. After treatment of the tissue blot with protease and subsequent MALDI MS analysis using postsource decay methods for peptide sequencing, some of the proteins were identified. The unique protein profiles measured from these tissue blots also showed differences from strain to strain of the mouse, with genetically similar strains having very similar patterns.  相似文献   

14.
A nonmetallic sample support for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry enhances the positive ion yield by 2 orders of magnitude and generally affects the charge balance in the desorption plume. We interpret the effects of the target material and of the sample preparation on MALDI mass spectra as a result of photoelectrons emitted upon laser irradiation of a metal target covered by a thin sample layer. These electrons are shown to play an important role in MALDI and laser desorption/ionization because they decrease the yield of positive ions, reduce ions with higher oxidation states, and affect the ion velocity distribution as well as the mass resolution. Understanding the role of these photoelectrons helps to clarify previously obscure aspects of the ion formation mechanism in MALDI.  相似文献   

15.
When used in small molar ratios of matrix to analyte, derivatized fullerenes and single wall nanotubes are shown to be efficient matrices for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The mixing of an acidic functionalized fullerene with a solution of bioanalyte, depositing a dried droplet, and irradiating with a pulsed nitrogen laser yields protonated or cationized molecular ions. Derivatized fullerenes could offer several advantages over conventional MALDI matrices: a high analyte ionization efficiency, a small molar ratios (less than 1) of matrix/analyte, and a broader optical absorption spectrum, which should obviate specific wavelength lasers for MALDI acquisitions. The major disadvantage to the use of fullerenes is the isobaric interference between matrix and analyte ions; however, it is overcome by using MALDI-ion mobility time-of-flight (IM-oTOF) mass spectrometry to preseparate carbon cluster ions from bioanalyte ions prior to TOF mass analysis. However, an alternative to the dried droplet preparation of fullerene MALDI samples is the aerosolization of matrix-analyte solutions (or slurries) followed by impacting the aerosol onto a stainless surface. We also demonstrate that the fullerene matrices can be used to acquire spectra from rat brain tissue.  相似文献   

16.
Intense intact molecular ion signals have been obtained from phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, and phosphatidyiinositol using matrix-enhanced secondary ion mass spectrometry (ME-SIMS). It was found that the high-mass (m/z >500) regions of the ME-SIMS spectra closely resembled those obtained using matrix-assisted laser desorption/ionization (MALDI). Using high spatial resolution SIMS, a detailed investigation of dried-droplet samples was performed. Based on the detected Na+ and 2,5-DHB matrix signal intensities, different crystal types were distinguished, in addition to different sizes of crystals. Spatially mapping the pseudomolecular and fragment ions of the phospholipids revealed that the nature of the pseudomolecular ions formed, as well as the ratio of intact molecular to fragment ion, was dependent on the type and surface composition of the crystal. The observed chemical bias effects due to crystal heterogeneity and the resulting variation in desorption/ionization efficiency will complicate the interpretation of data obtained from matrix-assisted mass spectrometric (imaging) techniques and is an important factor in the "hot spot" phenomenon frequently encountered in MALDI experiments. In this respect, imaging SIMS was found to be a versatile tool to investigate the effects of the local physicochemical conditions on the detected molecular species.  相似文献   

17.
Zhang N  Li L 《Analytical chemistry》2002,74(7):1729-1736
Sodium dodecyl sulfate (SDS) is a strong surfactant that is widely used in protein sample preparation. While protein and peptide samples containing up to approximately 1% SDS can be analyzed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) using a two-layer matrix/sample deposition method, the presence of SDS in a protein sample generally degrades mass resolution and mass measurement accuracy. This degradation in performance is found to be related to the formation of sodium-protein adducts in the MALDI process. If the instrument resolving power is insufficient to separate these adduct peaks from the protonated molecular ion peak, peak broadening is observed in the protein molecular ion region, and as a result, the peak centroid shifts to a higher mass. In this work, we present a method using ammonium dodecyl sulfate as a viable alternative to SDS for protein sample preparation with much improved MALDI MS performance. Three non-sodium-based dodecyl sulfate surfactants, ammonium dodecyl sulfate (ADS), hydrogen dodecyl sulfate, and tris(hydroxymethyl)aminomethane dodecyl sulfate were investigated. Of the three surfactants tested, it is found that ADS gives the best performance in MALDI. For proteins with moderate molecular masses (i.e., up to approximately 25 kDa), the presence of ADS in a protein sample does not result in significant degradation in mass resolution and accuracy, and the protonated molecular ion peak is the dominant peak in the MALDI spectrum. The ammonium adduct ions dominate the MALDI spectra when the protein mass exceeds approximately 25 kDa; however, ADS still gives better results than SDS. The behavior of ADS in gel electrophoresis was also investigated. It is shown that cell extracts dissolved in ADS can be separated by normal SDS-polyacrylamide gel electrophoresis by simply mixing them with the SDS sample buffer. The application of ADS as the surfactant for protein solubilization with improved performance in MALDI analysis is demonstrated in the study of a detergent insoluble fraction from a Raji/CD9 B-cell lymphocyte lysate.  相似文献   

18.
Thin-layer chromatography (TLC), which is widely used for separation of glycolipids, oligosaccharides, lipids, and compounds of environmental and pharmaceutical interest, can be readily coupled to matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometers, but this arrangement usually compromises mass spectral resolution due to the irregularity of the TLC surface. However, TLC can be coupled to an external ion source MALDI-Fourier transform (FT) MS instrument without compromising mass accuracy and resolution of the spectra. Furthermore, when the FTMS has a vibrationally cooled MALDI ion source, fragile glycolipids can be desorbed from TLC plates without fragmentation, even to the point that desorption of intact molecules from "hot"matrixes such as alpha-cyano-4-hydroxycinnamic acid is possible. In this work, whole brain gangliosides are separated using TLC; the TLC plates are attached directly to the MALDI target, where the gangliosides are desorbed, ionized, and detected in the FTMS with >70 000 resolving power.  相似文献   

19.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a central tool for proteomic analysis, yet the singly protonated tryptic peptide ions produced by MALDI are significantly more difficult to dissociate for tandem mass spectrometry (MS/MS) than the corresponding multiply protonated ions. In order to overcome this limitation, current proteomic approaches using MALDI-MS/MS involve high-energy collision-induced dissociation (CID). Unfortunately, the use of high-energy CID complicates product ion spectra with a significant proportion of irrelevant fragments while also reducing mass accuracy and mass resolution. In order to address the lack of a high-resolution, high mass accuracy MALDI-MS/MS platform for proteomics, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and a recently developed MS/MS technique termed CIRCA (for combination of infrared and collisional activation) have been applied to proteomic analysis. Here, CIRCA is shown to be suitable for dissociating singly protonated tryptic peptides, providing greater sequence coverage than either CID or infrared multiphoton dissociation (IRMPD) alone. Furthermore, the CIRCA fragmentation spectra are of sufficient quality to allow protein identification based on the MS/MS spectra alone or in concert with the peptide mass fingerprint (PMF). This is accomplished without compromising mass accuracy or mass resolution. As a result, CIRCA serves to enable MALDI-FTICR-MS/MS for high-performance proteomics experiments.  相似文献   

20.
Positive and negative ions produced from matrix-assisted laser desorption/ionization (MALDI) were simultaneously measured using a newly developed dual-polarity time-of-flight mass spectrometer. This instrument is effective not only for express and comprehensive mass analysis but also for studying the ionization mechanisms of biomolecules. It comprises two identical time-of-flight mass analyzers located symmetrically about a MALDI ion source. The ion optics are arranged to be able to extract positive and negative ions synchronously with equal efficiency to each corresponding mass analyzer. Mass spectra of various proteins with molecular weights as large as that of myoglobin monomer and dimer were obtained. The spectral patterns obtained in this work are approximately mirror images with opposite polarities.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号