共查询到20条相似文献,搜索用时 93 毫秒
1.
2.
4.
5.
本应用对称分量法分析了常见三相无功功率变送器的测量原理,推导了用于测量不平衡三相电路无功功率时的原理性误差,比较了不同类型变送器的性能,提出了推荐使用的建议 。 相似文献
6.
7.
三相有功功率变送器的单相法检定具有检定装置简单、体积小、重量轻、操作方便等特点,对于现场检定尤为有利。本文论证了单相法的理论根据,推导了修正公式,并通过多例典型试验验证了理论公式的正确性和实用性。 相似文献
8.
10.
11.
12.
A physical model of a thyristor ac voltage regulator with microcontroller control operating under an active-inductive load is considered. To increase the level of energy efficiency of existing electric power systems, the arrangement of the control of voltage level of supplied centers both above and below the rated value is an important condition. In existing structures, the transformation ratio generally is a constant, which does not make it possible to take into account the real irregularities of electric energy consumption. Using a transformer in a thyristor voltage regulator makes it possible to solve this problem. It shows that it may be possible to enter a preliminary stage of physical modeling of the considered process by means of creation of a program–technical complex making it possible to simulate the process of transportation of electrical energy from supply centers to consumers. 相似文献
13.
14.
介绍了适合电力电容器试验用的9种脉冲电流传感器的设计、制作、标定与应用,其中5种是典型的罗氏线圈,另外4种是自积分式线圈,可用于电容器检测与试验研究中幅值极高和幅值很小的脉冲电流的测量,经试用效果良好。 相似文献
15.
16.
Yang Xiaoxian Zheng Tao Zhang Baohui Huang Zonghong Chen Jian Gui Zhiqiang 《Power Delivery, IEEE Transactions on》2007,22(1):129-134
Based on the typical topology and physical properties of a 10-kV power network, this paper first proposes a linear time-variant filter with additive noise to be the general channel model which takes into account the main problems that interfere with communications. Then it discusses the corresponding measurement methods. Next, for the first time in the related research area, the electrical loop wire was applied for the measurement of amplitude and phase responses of the transfer function H(f), which provides a better way to solve the problem of obtaining the phase response if the power line is relatively long. Also, the multitones method for the narrow-band fading measurement is put forward. Finally, it is concluded that moving the calibration reference plane of the network analyzer to a proper position improves the measurements efficiency and accuracy and these methods can be referred to in the 10-kV power-line channel study 相似文献
17.
建立一个变压器缩尺模型,在半消声室环境下,以PULSE声振采集系统为测量分析平台,输出并采集各工况下测点的噪声数据。通过比较GB/T 1094.10—2003《电力变压器 第10部分:声级测定》与GB 6882—86 《声学 噪声源声功率级的测定:消声室和半消声室精密法》2种标准测量计算的变压器辐射声功率,验证了工程测量标准GB/T 1094.10—2003的准确性和稳定性,研究了不同声学边界条件对声功率测量结果的影响。实验结果表明:防火墙对变压器辐射声功率有一定影响;不同声学边界条件下,2种测试标准声功率测量结果非常接近,且差值都在1 dB以内,表明工程测量标准GB/T 1094.10—2003的准确性和稳定性很高。 相似文献
18.
19.
大型电力变压器铁磁结构件中产生的电磁损耗会导致局部过热并使相关的绝缘部件受到损害,进而危及整个变压器的正常运行,对面向工程的国际TEAM(Testing Electromagnetic Analysis Methods)Problem 21的磁屏蔽基准模型的涡流场和损耗进行了计算和试验测量研究,考虑了模型中铁磁材料的非线性、各向异性及磁滞等特性,提出了用于分离激励线圈电阻损耗和涡流损耗的测量方法(漏磁通补偿线圈测量装置),并用MagNet软件进行了数值计算.基准模型的计算和测量结果相吻合,验证了计算方法和软件的有效性. 相似文献