首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
R Detrano 《Canadian Metallurgical Quarterly》1997,95(2):534; author reply 535-534; author reply 536
  相似文献   

2.
Mecanic computed tomography would probably never reach the acquisition brevity obtained by EBT. This machine is the best for exploration of cardiovascular diseases, and non cooperative patients, and for cine and flow studies. Morever, there are never tube cooling delays or interruptions in any procedures. Its disadvantages are the price, the impossibility to tilt the gantry, and the computer which are to be improved. With "Evolution", Siemens proposes now improvements with the CVS mode and a computer release without increasing of the price.  相似文献   

3.
Comparison of radiation exposure applied by different types of CT scanners for the investigation of the chest and abdomen. Determination of radiation exposure applied by multi-phase spiral CT. Estimation of the dose in air in the system axis of the scanner, the CT dose index (CTDI) and the effective dose for electron beam tomography (EBT) and two conventional CT scanners (sequence, SEQ; spiral, SCT). For EBT, dose in system axis for investigation of the abdomen was above 50 mGy. Effective dose for investigation of the chest and abdomen was higher with EBT (11 and 26 mSv, respectively) than with conventional CT (SEQ, 4 and 20 mSv; SCT, 2 and 7 mSv). The effective dose for a biphasic investigation (liver 5 mSv, kidney 4 mSv) was below, for a triphasic investigation (liver 7 mSv) above the effective dose of the investigation of the abdomen (6 mSv). Investigation of the abdomen with the EBT should only be performed for certain indications. With spiral CT, effective dose is much lower than with EBT.  相似文献   

4.
OBJECTIVE: To assess three-dimensional computed tomography 'bronchoscopic' (3-DCTB) reconstruction of routine CT data as a non-invasive method of airway visualization, and compare it with fibreoptic bronchoscopy (FOB). METHODS: Fourteen datasets were acquired from 13 patients undergoing both FOB and CT examination of the chest. Standard continuous volume CT using 6 mm collimation and clinical FOB techniques were employed. Images were obtained from 3-DCTB reconstructions by segmentation and surface recognition algorithms generating surface rendered 'bronchoscopic views'. These were scored for technical quality and anatomical detail. The most distal bronchi seen in left upper and right lower lobes were recorded for FOB and 3-DCTB. RESULTS: On FOB, the subsegmental bronchi were seen in right lower and in left upper lobe in 10/14 cases and 4/14 cases, respectively. Visualization of the subsegmental airways was not achieved with 3-DCTB, as they could not be identified with confidence. 3-DCTB never achieved a more distal view than obtained by FOB. Using 3-DCT, the right, lower lobe segmental bronchi were seen in 10/14 cases, and lobar bronchus in 14/14 cases (two occluded). In the left upper lobe, 3-DCT showed segmental bronchi in 6/14 cases, lobar bronchus in 11/14 cases (one occluded) and the left main bronchus appeared occluded in 3/14 cases. Overall, technical quality and anatomical detail scores of the carina and proximal bronchi ranked significantly higher than views of segmental bronchi. CONCLUSIONS: 3-DCTB cannot routinely replace FOB for inspection of major and segmental bronchi. Subsegmental bronchi cannot be adequately demonstrated by 3-DCTB using 6 mm collimation datasets.  相似文献   

5.
6.
Image quality and dose produced by a spiral CT with various pitch values were investigated on the basis of test-object images and measurements of CT dose indexes. No major difference in image quality or dose was observed when comparing sequential and spiral mode acquisition with a pitch of one. Increase in pitch value produces a loss of contrast which leads to a loss of detectability. Nevertheless, in realistic protocols the image quality in the transverse plane remains acceptable up to pitch values of 1.3-1.6.  相似文献   

7.
DNA mismatch repair ensures genomic stability by correcting biosynthetic errors and by blocking homologous recombination. MutS-like and MutL-like proteins play important roles in these processes. In Escherichia coli and yeast these two types of proteins form a repair initiation complex that binds to mismatched DNA. However, whether human MutS and MutL homologs interact to form a complex has not been elucidated. Using immunoprecipitation and Western blot analysis we show here that human MSH2, MLH1, PMS2 and proliferating cell nuclear antigen (PCNA) can be co-immunoprecipitated, suggesting formation of a repair initiation complex among these proteins. Formation of the initiation complex is dependent on ATP hydrolysis and at least functional MSH2 and MLH1 proteins, because the complex could not be detected in tumor cells that produce truncated MLH1 or MSH2 protein. We also demonstrate that PCNA is required in human mismatch repair not only at the step of repair initiation, but also at the step of repair DNA re-synthesis.  相似文献   

8.
The introduction of helical computed tomography (CT) has resulted in improved quality of multiplanar reformations and three-dimensional reconstructions in the chest and abdomen and has made CT angiography a clinical reality. These imaging techniques are useful for evaluating the urinary tract, adding a new dimension to its display, resulting in improved diagnosis of renal and perirenal disease. This article reviews the indications and techniques utilized for multiplanar and three-dimensional CT for urology. The advantages and limitations are discussed, and normal and pathologic findings in the urinary tract illustrated.  相似文献   

9.
Conventional studies on bracken fern (Pteridium aquilinum; PA) carcinogenicity have used high dietary concentrations (around 30%) and long-term exposure (up to 52-70 weeks) without consideration of the multistep character of the chemical carcinogenesis process. The present study evaluated specifically the promoting potential of 3-5% dietary crude PA in the rat urinary bladder mucosa in a 32-week-long initiation-promotion assay for chemical carcinogenesis. Initiation of urothelial carcinogenesis was accomplished with N-butyl-N-(4-hydroxybutyl)-nitrosamine (BBN). Uracil (U) was provided through the diet in order to expand the population of initiated cells. Seven groups (G) of male Wistar rats were submitted to the following treatments: G1 = BBN (n = 8); G2 = U (n = 10); G3 = BBN-U (n = 9); G4 = BBN-PA-U-PA (n = 16); G5 = PA (n = 8); G6 = BBN-PA (n = 10); G7 = PA-U-PA (n = 12). At the end of the experiment rats presenting epithelial papillary or nodular hyperplasia (PNH), papillomas (PAP), or simultaneous PNH plus PAP numbered, respectively G1: 2-0-1; G2: 0-0-0; G3: 3-0-2; G4: 4-3-2; G5: 1-0-1; G6: 8-0-0; and G7: 0-0-0, with no significant differences in the incidence of lesions among the groups. More frequent and more severe lesions occurred in BBN-initiated animals, predominantly in those also exposed to uracil (G3 and G4). Low-dose crude bracken fern in the diet does not promote rat urinary bladder carcinogenesis after a 32-week period of exposure, even when the initiated urothelial cell population has been expanded through a mechanical stimulus.  相似文献   

10.
11.
This blinded, single center study prospectively compares exercise electron beam computed tomography (EBCT) with stress technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) in 33 patients undergoing coronary angiography for evaluation of chest pain. Patients undergoing routine cardiac catheterization for the diagnosis of chest pain were imaged at rest using EBCT. Patients exercised on a semi-supine ergometer, and exercise EBCT was immediately followed by injection of Tc-99m sestamibi for assessment of myocardial ischemia. At peak exercise, Tc-99m SPECT, followed immediately by nonionic contrast material, was injected intravenously to directly compare these 2 imaging techniques. Patients were reimaged with Tc-99m SPECT at rest 24 to 48 hours after stress. Exercise EBCT, which was analyzed using a global ejection fraction measure, had a sensitivity of 81% and a specificity of 76%, compared with angiography. Using the development of a new regional wall motion abnormality as evidence of obstructive coronary artery disease (CAD), EBCT yielded a specificity of 100% and a sensitivity of 88%. Reversible perfusion defects identified by SPECT, as evidence of obstructive CAD, revealed a sensitivity of 75% and a specificity of 71%. The specificity of regional wall motion analysis by EBCT was significantly better than SPECT (p <0.01) in this population. This study demonstrates regional wall motion assessed by EBCT to be as sensitive and more specific than SPECT myocardial perfusion imaging in identifying obstructive CAD as defined by angiography.  相似文献   

12.
This was a community-based study to evaluate the prevalence and characteristics of female urinary incontinence in women aged 18 and above in the Shatin District of Hong Kong. Of a total of 1018 female households contacted, 362 individuals were successfully interviewed and 123 women (34%) reported they had experienced at least one episode of urinary incontinence as adults. Of these, 18.5% reported persistent incontinence and 15.5% reported absence of incontinence after a single episode of urine loss. The risk factors for incontinence revealed by this study were body mass index and parity. Women who had never been incontinent had a lower body mass index and were usually nulliparous. Most of the respondents (43.9%) who had urinary incontinence considered the condition to be a minor problem and did not seek professional advice. This investigation indicates that a territory-wide study should be carried out to determine the incidence of urinary incontinence throughout Hong Kong.  相似文献   

13.
14.
RATIONALE AND OBJECTIVES: We developed a method for volumetric image deblurring in spiral (helical) computed tomography (CT) scanning with a three-dimensional (3D) Gaussian point spread function (PSF) to improve the quality of temporal bone spiral CT images for assessing the position of cochlear implants electrodes. METHODS: A patient was scanned after cochlear implantation, and the temporal bone was reconstructed into a volume with 128 voxels per dimension, 0.1 mm per voxel side, and x 10 gray-scale expansion. The 3D PSF in spiral CT imaging was assumed to be Gaussian separable transversely and longitudinally. Standard deviations of the PSF were derived and subjectively adjusted. The image was then deconvolved using Wiener filtering and maximum-likelihood deconvolution methods. Image quality was assessed both visually and quantitatively using cross-sectional area at half of the maximum (CAHM) of the implanted array as the figure of merit. RESULTS: Substantial image deblurring was achieved via deconvolution. Subjectively, anatomic structures were more clearly shown. Deconvolution reduced the CAHM by approximately one third, on average. Three-dimensional deconvolution had better image quality than two-dimensional deconvolution. The maximum-likelihood method produced superior image quality but took longer to process relative to Wiener filtering. CONCLUSION: Volumetric image deblurring is practical with a Gaussian PSF. The maximum-likelihood method is preferred if time permits. Deconvolution facilitates the study of fine details of the temporal bone and cochlear implant.  相似文献   

15.
Renovascular hypertension represents 1 to 2% of all causes of hypertension. It is important to make the diagnosis as radical treatment may be proposed. Digitised arteriography is the reference diagnostic method. Spiral angiotomography is a new diagnostic technique for the investigation of the aorta and its branches. The examination was performed with a Siemens Somatom Plus S spiral scanner. The images were acquired after intravenous injection of 140 ml of iodine contrast medium in the forearm. Three dimensional reconstruction of the renal arteries may be performed secondarily. The results of 16 examinations were compared with those of arteriography. Nine stenoses were suspected after spiral angiotomography and confirmed in 7 cases by arteriography (sensitivity 100%; specificity 77%); two adrenal abnormalities were also detected by spiral tomography. In this series, spiral angiotomography detected all cases of renal artery stenosis with good specificity. Moreover, this investigation also allowed evaluation of the adrenal glands. The simple, non-invasive and polyvalent nature of this method should, if the results are confirmed in a large series, lead to its use as the investigation of first intention for suspected secondary causes of hypertension.  相似文献   

16.
To meaningfully evaluate factors determining the overall accuracy of computed tomography (CT) for identifying pulmonary nodules, computer-generated nodules were superimposed on normal CT scans and interpreted independently by three experienced chest radiologists. Variables evaluated included nodule size, shape, number, density, location, edge characteristics, and relationship to adjacent vessels, as well as technical factors, including slice thickness and electronic windowing. The overall sensitivity in identifying nodules was 62% and the specificity was 80%. On average, the observers identified 56, 67, and 63% of nodules on 1.5-, 5-, and 10-mm-thick sections, respectively (p = 0.037). Nodules were more difficult to identify on 1.5-mm-thick sections. On average, observers identified 1, 48, 82, and 91% of nodules < 1.5, < 3, < 4.5, and < 7 mm in diameter, respectively (p < 0.001). Other factors that made a significant contribution (p < 0.01) in identifying nodules, as determined by linear discriminant function analysis, included nodule location, angiocentricity, and density. We concluded that computer-generated nodules can be used to assess a large number of imaging variables. We anticipate that this approach will be of considerable utility in assessing the accuracy of interpretation of a wide range of pathologic entities as well as in optimizing three-dimensional scan protocols within the thorax.  相似文献   

17.
18.
We report a case of arteriovenous fistula due to spontaneous rupture of an aortic aneurysm into the inferior vena cava. This is a rare complication of atheromatous aneurysm, often difficult to diagnose as the clinical presentation may be obscure. Although aortography is the reference diagnostic investigation, spiral CT acquisition with 3D and 2D reformation allowed visualization of the arteriovenous communication and provided an accurate diagnosis.  相似文献   

19.
Subsecond computed tomography (CT) scanning offers potential for improved heart imaging. We therefore developed and validated dedicated reconstruction algorithms for imaging the heart with subsecond spiral CT utilizing electrocardiogram (ECG) information. We modified spiral CT z-interpolation algorithms on a subsecond spiral CT scanner. Two new classes of algorithms were investigated: (a) 180 degrees CI (cardio interpolation), a piecewise linear interpolation between adjacent spiral data segments belonging to the same heart phase where segments are selected by correlation with the simultaneously recorded ECG signal and (b) 180 degrees CD (cardio delta), a partial scan reconstruction of 180 degrees + delta with delta < fan angle, resulting in reduced effective scan times of less than 0.5 s. Computer simulations as well as processing of clinical data collected with 0.75 s scan time were carried out to evaluate these new approaches. Both 180 degrees CI and 180 degrees CD provided significant improvements in image quality. Motion artifacts in the reconstructed images were largely reduced as compared to standard spiral reconstructions; in particular, coronary calcifications were delineated more sharply and multiplanar reformations showed improved contiguity. However, new artifacts in the image plane are introduced, mostly due to the combination of different data segments. ECG-oriented image reconstructions improve the quality of heart imaging with spiral CT significantly. Image quality and the display of coronary calcification appear adequate to assess coronary calcium measurements with conventional subsecond spiral CT.  相似文献   

20.
In this paper we deal with two types of spiral scanners; one is a single-slice spiral scanner, while the other employs dual-slice technology into spiral scanning. Physical performance parameters, including image noise, contrast resolution, spatial resolution (transversal and longitudinal), and radiation exposure are measured. Computer simulations based on two interpolation methods (180 degrees and 360 degrees linear interpolation) are also used in evaluating the slice-sensitivity profile (SSP) and noise. The results show that the noise behaves in the same way for both types of scanners. The noise change, relative to that of the standard scan with the same scanning parameters, depends solely on the interpolation algorithm. Table speed and scanner geometry (either single slice or dual slice) have no effect on the noise value. For the given table speed, as well as individual detector collimation (slice width) the dual-slice scan results in better longitudinal resolution (SSP) compared to a single-slice scan if the scan is obtained with nonoverlapping slices (pitch greater than 2). This is because the dual-slice scan obtains twice the number of nonoverlapped projections for the same length, which reduces the degradation of the slice profile by using more densely arranged projections (in the longitudinal direction) for the interpolation. In the dual-slice scanner the workable scan rate is extended up to pitch 4 compared to a pitch of 2 for the single-slice scanner. Therefore, the dual-slice spiral scanner is preferred in applications requiring an increased scan rate with comparative image quality.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号