共查询到20条相似文献,搜索用时 15 毫秒
1.
国内外对于控制电缆屏蔽层应一端接地还是两端接地仍存在很大的争议.从分析地电位升高的危害和控制电缆屏蔽层接地的作用入手,通过比较不同接地方式下引起地电位干扰的2种地网电流对控制电缆的感应电压的大小,得出两端接地时的干扰电压比一端接地时要小.因此控制电缆应采用屏蔽层两端接地的方式. 相似文献
2.
It is vital to study the electromagnetic coupling to shielded cable for improving electromagnetic antiinterference ability
of secondary equipment in a substation. As a hybrid of method of moment (MoM) and transmission line method, a frequency domain
model is put forward to study the near field coupling to shielded cable due to the switching operation in substation. Compared
with the results of EMTP, the proposed method has been proven correct. Furthermore, this method overcomes the disadvantage
of EMTP, which is only applicable for transient analysis of parallel conductors. As an example, the presented method is applied
to evaluating the electromagnetic interference (EMI) to the shielded cable, whose shield is grounded at both ends, due to
the switching operation in 500 kV air insulation substation (AIS).
__________
Translated from Proceedings of the Chinese Society for Electrical Engineering, 2007, 27(9): 46–51 [译自: 中国电机工程学报] 相似文献
3.
4.
超六类屏蔽型数字通信电缆的设计与制造 总被引:1,自引:1,他引:0
本文介绍了超六类屏蔽型数字通信电缆的应用及其主要电性能指标 ,侧重描述了该种电缆的工艺设计、生产过程中的关键制造技术的控制 ,以便进一步提高产品质量 相似文献
5.
电缆屏蔽层接地方式及抗干扰分析 总被引:2,自引:1,他引:2
屏蔽电缆抑制干扰的能力除与屏蔽层本身的质量有关外,还与屏蔽层接地方法密切相关。提出良好的屏蔽,仅靠电缆屏蔽层是不够的,重要的是选择正确的屏蔽层接地方式、接地点数和接地位置。正确使用屏蔽和良好的接地则是使系统稳定运行、消除干扰的重要措施。着重阐述了电缆屏蔽层接地方式及其抗干扰分析,对工程应用具有实用价值和指导意义。 相似文献
6.
7.
8.
电力电缆故障冲闪测试放电回路建模 总被引:1,自引:0,他引:1
对电力电缆故障冲击高压闪络测试(简称冲闪测试)系统的放电响应进行了研究.在只考虑暂态低频分量信号的条件下,利用电缆的均匀传输线T型等效网络,建立了冲闪测试放电回路的集中参数电路模型.根据电缆的结构和材料参数.以及电缆集中参数与其分布参数之间的关系,推导了模型的电流、电压响应近似表达式.以及电流响应的衰减系数和振荡频率表... 相似文献
9.
10.
本文通过实验验证和数据分析 ,提出了小剂量电子辐照后 ,聚烯烃绝缘发生再交联现象 ,同时对其辐照工艺中有关问题进行了探讨 相似文献
11.
12.
Each time switching occurs, a PWM inverter produces high‐frequency leakage currents flowing through stray capacitors. Since the inverter for a trash conveyance crane is installed far away from the motor, the shield power cables between them become long, and leakage currents pass through the stray capacitances of the shielded cables and flow to the ground. This paper proposes a model circuit for analyzing leakage currents which flow into the shields of the cables. The effectiveness of the proposed model circuit is verified by comparison of simulated leakage currents using the proposed method and measured leakage currents. © 2002 Wiley Periodicals, Inc. Electr Eng Jpn, 140(2): 65–72, 2002; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/eej.2002 相似文献
13.
14.
加铜罩对XLPE电缆绕组外端口特性的影响 总被引:2,自引:0,他引:2
交联聚乙烯(XLPE)电缆绕组变压器[1-5]在运行时,由于铁心和外防护罩的影响,使得电缆绕组电感值发生变化和外半导电层对地电容比试验空心绕组的外半导电层对地电容增大许多.因此了解铁心和外防护罩对电缆绕组外端口特性的影响是很有必要的.本文用加铜罩的方法模拟防护罩的作用的方法,对试验绕组进行了对比试验,并在前期研究[6]的基础上建立了考虑外半导电层对地电容影响电缆绕组外端口等效电路模型.为该种新型变压器的设计、保护及试验技术提供了依据. 相似文献
15.
Saih Mohamed Rouijaa Hicham Abdelilah Ghammaz 《International Journal of Numerical Modelling》2016,29(2):243-254
The present study examines the variation effects of incident plane wave on multiconductor shielded cables in frequency domains using Branin's method, which is referred to as the method of characteristics. The model operates in frequency and time domains with linear and nonlinear loads, respectively, which allows it to be easily introduced into circuit simulators, such as SPICE, Sabar, and ESACAP. Two examples are studied: coaxial shielded cables and shielded cables with two parallel wires (i.e., twinax cables), and they are both excited by an incident plane wave. The results obtained by this method are in agreement with those obtained by other methods. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
16.
17.
提出一种新的二次电缆屏蔽层接地方法,即在开关场的一端经适当电阻接地,位于控制室的另一端直接接地。就不同电磁干扰耦合方式下二次电缆屏蔽层采用新型接地方法和传统接地方法时的抗干扰效果进行了分析比较,并对较为复杂的感性耦合方式进行了着重分析,发现采用新方法可以获得较好的电磁兼容效果,并可有效解决因地电流过大而可能烧毁屏蔽层的问题。 相似文献
18.
19.
提出了基于小波分析的电力电缆行波故障测距方法。该方法向待测电力电缆注入脉冲电流,利用小波分析对采样信号进行多分辨分析,得到模极大值点的位置,也就是采样信号突变点的位置,该突变点的位置反映了故障点的位置,从而实现电力电缆的故障测距。ATP/Matlab下的仿真计算结果表明,较之于传统的行波测量方法,该方法可以准确识别反射脉冲,降低电缆线路分支和近区故障反射波对测量精度的影响,测距精度不受故障类型的影响,测距误差小于一个采样距离。 相似文献
20.
开关电源中常用铜箔对磁性元件进行屏蔽以减小磁件与大地之间的电场耦合从而减小传导共模EMI发射。分析了传统全铜箔电场屏蔽体能有效屏蔽电场,但同时由于涡流效应也会影响高频磁场的分布,从而带来额外的涡流损耗和磁件电磁参数的变化,因此不适用于功率变换器中某些仅需要屏蔽电场但又不能屏蔽高频磁场的场合。提出的梳状电场屏蔽体结构具有只屏蔽电场,而不屏蔽高频磁场的特性,同时还能显著减低屏蔽体的临近效应涡流损耗。通过仿真分析了梳状屏蔽体结构参数对电场和高频磁场的影响。最后结合梳状屏蔽体在LLC集成漏感变压器中的应用验证了其实际有效性和可行性。 相似文献