首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This work proposes an efficient combined treatment for the decontamination of a pesticide-containing wastewater resulting from phytopharmaceutical plastic containers washing, presenting a moderate organic load (COD = 1662-1960 mg O2 L−1; DOC = 513-696 mg C L−1), with a high biodegradable organic carbon fraction (81%; BOD5 = 1350-1600 mg O2 L−1) and a remaining recalcitrant organic carbon mainly due to pesticides. Nineteen pesticides were quantified by LC-MS/MS at concentrations between 0.02 and 45 mg L−1 (14-19% of DOC). The decontamination strategy involved a sequential three-step treatment: (a) biological oxidation process, leading to almost complete removal of the biodegradable organic carbon fraction; (b) solar photo-Fenton process using CPCs, enhancing the bio-treated wastewater biodegradability, mainly due to pesticides degradation into low-molecular-weight carboxylate anions; (c) and a final polishing step to remove the residual biodegradable organic carbon, using a biological oxidation process. Treatment performance was evaluated in terms of mineralization degree (DOC), pesticides content (LC-MS/MS), inorganic ions and low-molecular-weight carboxylate anions (IC) concentrations. The estimated phototreatment energy necessary to reach a biodegradable wastewater, considering pesticides and low-molecular-weight carboxylate anions concentrations, Zahn-Wellens test and BOD5/COD ratio, was only 2.3 kJUV L−1 (45 min of photo-Fenton at a constant solar UV power of 30 W m−2), consuming 16 mM of H2O2, which pointed to 52% mineralization and an abatement higher than 86% for 18 pesticides. The biological oxidation/solar photo-Fenton/biological oxidation treatment system achieved pesticide removals below the respective detection limits and 79% mineralization, leading to a COD value lower than 150 mg O2 L−1, which is in agreement with Portuguese discharge limits regarding water bodies.  相似文献   

2.
Degradation of the emerging contaminant ibuprofen in water by photo-Fenton   总被引:3,自引:0,他引:3  
In this study the degradation of the worldwide Non-Steroidal Anti-Inflammatory Drug (NSAID) ibuprofen (IBP) by photo-Fenton reaction by use of solar artificial irradiation was carried out. Non-photocatalytic experiments (complex formation, photolysis and UV/Vis-H2O2 oxidation) were executed to evaluate the isolated effects and additional differentiated degradation pathways of IBP. The solar photolysis cleavage of H2O2 generates hydroxylated-IBP byproducts without mineralization. Fenton reaction, however promotes hydroxylation with a 10% contamination in form of a mineralization. In contrast photo-Fenton in addition promotes the decarboxylation of IBP and its total depletion is observed. In absence of H2O2 a decrease of IBP was observed in the Fe(II)/UV-Vis process due to the complex formation between iron and the IBP-carboxylic moiety. The degradation pathway can be described as an interconnected and successive principal decarboxylation and hydroxylation steps. TOC depletion of 40% was observed in photo-Fenton degradation. The iron-IBP binding was the key-point of the decarboxylation pathway. Both decarboxylation and hydroxylation mechanisms, as individual or parallel process are responsible for IBP removal in Fenton and photo-Fenton systems. An increase in the biodegradability of the final effluent after photo-Fenton treatment was observed. Final BOD5 of 25 mg L−1 was reached in contrast to the initial BOD5 shown by the untreated IBP solution (BOD5 < 1 mg L−1). The increase in the biodegradability of the photo-Fenton degradation byproducts opens the possibility for a complete remediation with a final post-biological treatment.  相似文献   

3.
In this work, the photocatalytic degradation of the antibiotic sulfamethoxazole (SMX) by solar photo-Fenton at pilot plant scale was evaluated in distilled water (DW) and in seawater (SW). Degradation and mineralization of SMX were strongly hindered in SW compared to DW. The influence of H2O2 and iron concentration on the efficiency of the photocatalytic process was evaluated. An increase in iron concentration from 2.6 to 10.4 mg L−1 showed only a slight improvement in SMX degradation and mineralization. However, an increase in H2O2 concentration up to 120 mg L−1 during photo-Fenton in DW decreased SMX solution toxicity from 85% to 20%, according to results of Daphnia magna bioassays. The same behaviour was not observed after photo-Fenton treatment in SW. Despite 45% mineralization in SW, toxicity increased from 16% to 86% as shown by Vibrio fischeri bioassays, which suggests that the intermediates generated in SW are different from those in DW. A SMX degradation pathway during the photo-Fenton treatment in DW is proposed.  相似文献   

4.
Characterization and treatment of a real pharmaceutical wastewater containing 775 mg dissolved organic carbon per liter by a solar photo-Fenton/biotreatment were studied. There were also many inorganic compounds present in the matrix. The most important chemical in this wastewater was nalidixic acid (45 mg/L), an antibiotic pertaining to the quinolone group. A Zahn-Wellens test demonstrated that the real bulk organic content of the wastewater was biodegradable, but only after long biomass adaptation; however, the nalidixic acid concentration remained constant, showing that it cannot be biodegraded. An alternative is chemical oxidation (photo-Fenton process) first to enhance biodegradability, followed by a biological treatment (Immobilized Biomass Reactor - IBR). In this case, two studies of photo-Fenton treatment of the real wastewater were performed, one with an excess of H2O2 (kinetic study) and another with controlled H2O2 dosing (biodegradability and toxicity studies). In the kinetic study, nalidixic acid completely disappeared after 190 min. In the other experiment with controlled H2O2, nalidixic acid degradation was complete at 66 mM of H2O2 consumed. Biodegradability and toxicity bioassays showed that photo-Fenton should be performed until total degradation of nalidixic acid before coupling a biological treatment. Analysis of the average oxidation state (AOS) demonstrated the formation of more oxidized intermediates. With this information, the photo-Fenton treatment time (190 min) and H2O2 dose (66 mM) necessary for adequate biodegradability of the wastewater could be determined. An IBR operated in batch mode was able to reduce the remaining DOC to less than 35 mg/L. Ammonium consumption and NO3 generation demonstrated that nitrification was also attained in the IBR. Overall DOC degradation efficiency of the combined photo-Fenton and biological treatment was over 95%, of which 33% correspond to the solar photochemical process and 62% to the biological treatment.  相似文献   

5.
The degradation of 15 emerging contaminants (ECs) at low concentrations in simulated and real effluent of municipal wastewater treatment plant with photo-Fenton at unchanged pH and Fe = 5 mg L−1 in a pilot-scale solar CPC reactor was studied. The degradation of those 15 compounds (Acetaminophen, Antipyrine, Atrazine, Caffeine, Carbamazepine, Diclofenac, Flumequine, Hydroxybiphenyl, Ibuprofen, Isoproturon, Ketorolac, Ofloxacin, Progesterone, Sulfamethoxazole and Triclosan), each with an initial concentration of 100 μg L−1, was found to depend on the presence of CO32− and HCO3 (hydroxyl radicals scavengers) and on the type of water (simulated water, simulated effluent wastewater and real effluent wastewater), but is relatively independent of pH, the type of acid used for release of hydroxyl radicals scavengers and the initial H2O2 concentration used. Toxicity tests with Vibrio fisheri showed that degradation of the compounds in real effluent wastewater led to toxicity increase.  相似文献   

6.
Tokumura M  Ohta A  Znad HT  Kawase Y 《Water research》2006,40(20):3775-3784
The photochemical decolorization of coffee effluent has been examined by photo-Fenton (UV/Fe2+/H2O2) process. Effects of UV light intensity, initial coffee concentration, iron dose and H2O2 dose on the color removal of model coffee effluent have been investigated. The rate of decolorization increased with decreasing initial coffee effluent concentration. It was found that the Fe ion dose and UV light intensity enhanced the decolorization rate. The decolorization process of coffee effluent could be divided into three established phases. At the beginning of the photo-Fenton process, the instantaneous and significant increase in color of the solution was found (Phase-I). In the subsequent phase (Phase-II), the decolorization rate was initially fast and subsequently decreased. In Phase-III, the rate was accelerated and then the complete decolorization of model coffee effluent was achieved. In order to elucidate the mechanisms of coffee effluent color removal process, the concentration changes in Fe3+ and Fe2+ besides H2O2 were measured during the course of the photo-Fenton process. The rate-determining step in Phase-II was the photo-Fenton reaction or photoreduction of Fe3+. On the other hand, the decolorization process in Phase-III was highly affected by Fenton reaction or decomposition of H2O2 with Fe2+. About 93% mineralization of 250 mg L−1 model coffee effluent was achieved after 250 min. A comparative study for TiO2, ZnO and photo-Fenton oxidation processes has been also carried out and the photo-Fenton process was found to be the most effective for color removal of coffee effluent.  相似文献   

7.
This study focuses on the removal of 32 selected micropollutants (pharmaceuticals, corrosion inhibitors and biocides/pesticides) found in an effluent coming from a municipal wastewater treatment plant (MWTP) based on activated sludge. Dissolved organic matter was present, with an initial total organic carbon of 15.9 mg L−1, and a real global quantity of micropollutants of 29.5 μg L−1. The treatments tested on the micropollutants removal were: UV-light emitting at 254 nm (UV254) alone, dark Fenton (Fe2+,3+/H2O2) and photo-Fenton (Fe2+,3+/H2O2/light). Different irradiation sources were used for the photo-Fenton experiences: UV254 and simulated sunlight. Iron and H2O2 concentrations were also changed in photo-Fenton experiences in order to evaluate its influence on the degradation. All the experiments were developed at natural pH, near neutral. Photo-Fenton treatments employing UV254, 50 mg L−1 of H2O2, with and without adding iron (5 mg L−1 of Fe2+ added or 1.48 mg L−1 of total iron already present) gave the best results. Global percentages of micropollutants removal achieved were 98 and a 97% respectively, after 30 min of treatments. As the H2O2 concentration increased (10, 25 and 50 mg L−1), best degradations were observed. UV254, Fenton, and photo-Fenton under simulated sunlight gave less promising results with lower percentages of removal.The highlight of this paper is to point out the possibility of the micropollutants degradation in spite the presence of DOM in much higher concentrations.  相似文献   

8.
This paper reports on cork boiling and bleaching wastewaters treatment by solar photocatalytic processes, TiO2/UV and Fe2+/H2O2/UV (TiO2-only for bleaching wastewater), in a pilot plant with compound parabolic collectors. The photo-Fenton reaction (k = 0.12 L/kJUVr0 = 59.4 mg/kJUV) is much more efficient that TiO2 photocatalysis and TiO2 + S2O82− (k = 0.0024 L/kJUV, r0 = 1.36 mg/kJUV), leading to 94% mineralization of the bleaching wastewater after 31.5 kJUV/L, consuming 77.1 mM of H2O2 (3.0 mmol/kJUV) and using 20 mg/L of iron. For the cork boiling wastewater, after a slow initial reaction rate, the DOC degradation curve shows a first-order kinetics behaviour (k = 0.015 L/kJUV, r0 = 20.8 mg/kJUV) until 173 kJUV/L (≈300 mg C/L). According to the average oxidation state (AOS), toxicity profiles, respirometry and kinetic results obtained in two solar CPCs plants, the optimal energy dose estimated for phototreatment to reach a biodegradable effluent is 15 kJUV/L and 114 kJUV/L, consuming 33 mM and 151 mM of H2OT:/PGN/ELSEVIER/WR/web/00007490/2, achieving almost 49% and 48% mineralization of the wastewaters, respectively for the cork bleaching and boiling wastewaters.  相似文献   

9.
This work investigated the application of a solar driven advanced oxidation process (solar photo-Fenton), for the degradation of antibiotics at low concentration level (μg L−1) in secondary treated domestic effluents at a pilot-scale. The examined antibiotics were ofloxacin (OFX) and trimethoprim (TMP). A compound parabolic collector (CPC) pilot plant was used for the photocatalytic experiments. The process was mainly evaluated by a fast and reliable analytical method based on a UPLC-MS/MS system. Solar photo-Fenton process using low iron and hydrogen peroxide doses ([Fe2+]0 = 5 mg L−1; [H2O2]0 = 75 mg L−1) was proved to be an efficient method for the elimination of these compounds with relatively high degradation rates. The photocatalytic degradation of OFX and TMP with the solar photo-Fenton process followed apparent first-order kinetics. A modification of the first-order kinetic expression was proposed and has been successfully used to explain the degradation kinetics of the compounds during the solar photo-Fenton treatment. The results demonstrated the capacity of the applied advanced process to reduce the initial wastewater toxicity against the examined plant species (Sorghum saccharatum, Lepidium sativum, Sinapis alba) and the water flea Daphnia magna. The phytotoxicity of the treated samples, expressed as root growth inhibition, was higher compared to that observed on the inhibition of seed germination. Enterococci, including those resistant to OFX and TMP, were completely eliminated at the end of the treatment. The total cost of the full scale unit for the treatment of 150 m3 day−1 of secondary wastewater effluent was found to be 0.85 € m−3.  相似文献   

10.
A solar photo-Fenton process combined with a biological nitrification and denitrification system is proposed for the decontamination of a landfill leachate in a pilot plant using photocatalytic (4.16 m2 of Compound Parabolic Collectors - CPCs) and biological systems (immobilized biomass reactor). The optimum iron concentration for the photo-Fenton reaction of the leachate is 60 mg Fe2+ L−1. The organic carbon degradation follows a first-order reaction kinetics (k = 0.020 L kJUV−1, r0 = 12.5 mg kJUV−1) with a H2O2 consumption rate of 3.0 mmol H2O2 kJUV−1. Complete removal of ammonium, nitrates and nitrites of the photo-pre-treated leachate was achieved by biological denitrification and nitrification, after previous neutralization/sedimentation of iron sludge (40 mL of iron sludge per liter of photo-treated leachate after 3 h of sedimentation). The optimum C/N ratio obtained for the denitrification reaction was 2.8 mg CH3OH per mg N-NO3, consuming 7.9 g/8.2 mL of commercial methanol per liter of leachate. The maximum nitrification rate obtained was 68 mg N-NH4+ per day, consuming 33 mmol (1.3 g) of NaOH per liter during nitrification and 27.5 mmol of H2SO4 per liter during denitrification. The optimal phototreatment energy estimated to reach a biodegradable effluent, considering Zahn-Wellens, respirometry and biological oxidation tests, at pilot plant scale, is 29.2 kJUV L−1 (3.3 h of photo-Fenton at a constant solar UV power of 30 W m−2), consuming 90 mM of H2O2 when used in excess, which means almost 57% mineralization of the leachate, 57% reduction of polyphenols concentration and 86% reduction of aromatic content.  相似文献   

11.
In this paper, the application of Fenton and Oxone/Co2+ oxidation processes for landfill leachate treatment was investigated. The removal of the chemical oxygen demand (COD), suspended substances (SS) and the color of the landfill leachate by Fenton oxidation to that by Oxone/Co2+ oxidation were compared under optimal operational conditions. For Fenton oxidation process, the optimal conditions were determined as: [H2O2] = 80 mmol L−1, [H2O2]/[Fe2+] = 2.0, initial pH = 2.5, reaction temperature = 37.5 ± 1 °C, reaction time = 160 min, number of stepwise addition = 3. Under the given conditions, 56.9% of the COD removal efficiency was achieved, but the SS and the color of the treated landfill leachate increased due to the generation of a large quantity of ferric hydroxide sludge. In reference to Oxone/Co2+ oxidation process, the optimal conditions were determined as: [Oxone] = 4.5 mmol L−1, [Oxone]/[Co2+] = 104, pH = 6.5, reaction temperature = 30 ± 1 °C, reaction time = 300 min, number of stepwise addition = 7, the COD, SS and the color removal efficiencies were 57.5, 53.3 and 83.3%, respectively. From this work, it can be concluded that Oxone/Co2+ oxidation process demonstrated higher degradation efficiencies of the COD, SS and color for landfill leachate treatment than that by Fenton oxidation process. It also suggested that Oxone/Co2+ oxidation process could be considered as one of the most promising technologies for practical applicability to treat landfill leachate in large scale. For further improving the efficiency of Oxone/Co2+ oxidation process, we proposed that combination of it with other technologies in future such as ultraviolet, ultrasound and biological methods.  相似文献   

12.
A combined strategy of a photo-Fenton pretreatment followed by a Sequencing Batch Biofilm Reactor (SBBR) was evaluated for total C and N removal from a synthetic wastewater containing exclusively 200 mg L−1 of the antibiotic Sulfamethoxazole (SMX). Photo-Fenton reaction was optimized at the minimum reagent doses in order to improve the biocompatibility of effluents with the subsequent biological reactor. Consequently, the pretreatment was performed with two different initial H2O2 concentrations (300 and 400 mg L−1) and 10 mg L−1 of Fe2+. The pre-treated effluents with the antibiotic intermediates as sole carbon source were used as feed for the biological reactor. The SBBR was operated under aerobic conditions to mineralize the organic carbon, and the Hydraulic Retention Time (HRT) was optimized down to 8 h reaching a removal of 75.7% of the initial Total Organic Carbon (TOC). The total denitrification of the NO3 generated along the chemical-biological treatment was achieved by means of the inclusion of a 24-h anoxic stage in the SBBR strategy. In addition, the Activated Sludge Model No. 1 (ASM1) was successfully used to complete the N balance determining the N fate in the SBBR.The characterization and the good performance of the SBBR allow presenting the assessed combination as an efficient way for the treatment of wastewaters contaminated with biorecalcitrant pharmaceuticals as the SMX.  相似文献   

13.
I. Michael 《Water research》2010,44(18):5450-5462
Two different technical approaches based on advanced oxidation processes (AOPs), solar Fenton homogeneous photocatalysis (hv/Fe2+/H2O2) and heterogeneous photocatalysis with titanium dioxide (TiO2) suspensions were studied for the chemical degradation of the fluoroquinolone ofloxacin in secondary treated effluents. A bench-scale solar simulator in combination with an appropriate photochemical batch reactor was used to evaluate and select the optimal oxidation conditions of ofloxacin spiked in secondary treated domestic effluents. The concentration profile of the examined substrate during degradation was determined by UV/Vis spectrophotometry. Mineralization was monitored by measuring the dissolved organic carbon (DOC). The concentrations of Fe2+ and H2O2 were the key factors for the solar Fenton process, while the most important parameter of the heterogeneous photocatalysis was proved to be the catalyst loading. Kinetic analyses indicated that the photodegradation of ofloxacin can be described by a pseudo-first-order reaction. The rate constant (k) for the solar Fenton process was determined at different Fe2+ and H2O2 concentrations whereas the Langmuir-Hinshelwood (LH) kinetic expression was used to assess the kinetics of the heterogeneous photocatalytic process. The conversion of ofloxacin depends on several parameters based on the various experimental conditions, which were investigated. A Daphnia magna bioassay was used to evaluate the potential toxicity of the parent compound and its photo-oxidation by-products in different stages of oxidation. In the present study solar Fenton has been demonstrated to be more effective than the solar TiO2 process, yielding complete degradation of the examined substrate and DOC reduction of about 50% in 30 min of the photocatalytic treatment.  相似文献   

14.
In this work it is demonstrated that Fenton's reagent can be electroproduced with abundant and cheap feedstock: oxygen saturated wastewater and solar energy. Experiments were carried out in a divided electrochemical flow cell using two electrodes: a three dimensional reticulated vitreous carbon cathode and stainless steel anode. Fenton's reagent is produced by oxygen reduction on the cathode in the presence of 1 mM Fe2+. The influence of electrolyte nature and its concentration and potential difference on the current efficiency, as well as the rate of Fenton's reagent electroproduction is discussed and it is concluded that over this extended range of conditions the current efficiency, for Fenton's reagent production, fell within the range 50-70%. It is possible to electroproduce a stoichiometric amount of Fenton reagent for the oxidation of 0.061 mM Reactive Black 5 (in tap water + 0.05 M Na2SO4, ≈pH 2.8). Similar results were obtained for solutions containing 0.1 mM Acid Green 25. Some practical applications in the field of water treatment are included. The energy required for drive electrochemical reaction is supplied to the flow cell by means of a commercial solar panel.  相似文献   

15.
Complete degradation of a pesticide mixture by a combination of a photo-Fenton pretreatment and an activated-sludge batch reactor is demonstrated. Four commercial pesticides, Laition, Metasystox, Sevnol and Ultracid were chosen for this experiment. The active ingredients are, respectively, dimethoate, oxydemeton-methyl, carbaryl and methidathion. The original pesticide concentration was 200 mg L−1. Biotreatment began after 31% photocatalytic mineralization, which after 5 h in a 6-L stirred batch-mode tank reactor with non-acclimated activated sludge, leaves the photo-Fenton effluent completely degraded. This biotreatment time is shorter than commonly found in municipal wastewater treatment plants (∼8-10 h). Therefore, the combined process is effective for rapid pesticide degradation in wastewater with complete removal of parent compounds and the associated DOC concentration. Nonetheless, assessment of this technology should take into account higher pesticide concentrations and how this factor affects both the photocatalytic and the biological oxidation.  相似文献   

16.
W.H. Chin  J.L. Harris 《Water research》2009,43(16):3940-3947
Greywater treatment by UVC/H2O2 was investigated with regard to the removal of chemical oxygen demand (COD). A COD reduction from 225 to 30 mg l−1 (overall removal of 87%) was achieved after settling overnight and subsequent irradiation for 3 h with 10 mM H2O2. Most of the contaminants were removed by oxidation since only 13% COD was removed by settlement.The removal of COD in the greywater followed a second-order kinetic equation, r = 0.0637[COD][H2O2], up to 10 mM H2O2. A slightly enhanced COD removal was observed at the initial pH of 10 compared with pH 3 and 7. This was attributed to the dissociation of H2O2 to O2H. The treatment was not affected by total concentration of carbonate (cT) of at least 3 mM, above which operation between pH 3 and 5 was essential. The initial biodegradability of the settled greywater (as BOD5:COD) was 0.22. After 2 h UVC/H2O2 treatment, a higher proportion of the residual contaminants was biodegradable (BOD5:COD = 0.41) which indicated its potential as a pre-treatment for a biological process.  相似文献   

17.
The present study provides results describing the degradation performance of the Sulfamethazine (SMT) antibiotic via photo-Fenton treatment. Experiments were carried out using 1 L solution samples of SMT (50 mg L−1) under different conditions. HPLC results reveal that both Fenton and photo-Fenton reactions were able to completely remove SMT antibiotic from the studied samples in less than 2 min treatment. Half-life times and kinetic parameters (assuming a pseudo-first-order kinetics at reaction initial stage, far from the equilibrium) for SMT degradation were determined and discussed. Hence, appropriate Fenton reagent loads are given to attain different targets proposed. TOC and HPLC data also revealed the presence of reaction intermediates; thus toxicity assays were performed regarding bacterial growth rate. The toxicity of an SMT solution was shown to increase during its degradation by means of photo-Fenton reactions.  相似文献   

18.
The efficiency of classical Fenton (CF) and modified Fenton (MF) as well as photo-Fenton processes in real wastewater treatment of pulp and paper (P&P) mill was investigated in this study. The chemical oxygen demand (COD) was chosen as the reference measurement for evaluating the treatment's efficiency. After determining the optimum parameters for each process, the effect of adding ultrasound (US) on improving treatment efficiency was examined. In addition, kinetic study and phytotoxicity analysis were conducted under optimum conditions for all processes. With pH 4, reaction time 50 min, 1.2 g/L Fe2+ and 8 g/L H2O2 dosages, the best removal efficiency (RE) of COD was determined to be 82.18% in CF process, and this rate rose to 90.1% when US was added. The best RE in MF process was 84.16% with the application of UV-C, pH 4, reaction time 50 min, 1 g/L Fe0 and 8 g/L H2O2 doses, although it increased to 93.4% when US was applied. The greatest results in the seed germination test were achieved in US processes with 100% of germination percentage (GP) for spinach and tomato and 90% for cress. In the economic evaluation, when conducting the treatment without US, the estimated relative cost decreased in a 15 and 16%, for CF/UV-C and CF processes respectively, whereas the CF process was 64% cheaper than the MF process in all applications. The US contributed to enhanced water treatment efficiency by having a significant synergistic impact on Fenton applications. Hence, the combination of photo-Fenton and ultrasound to treat effluent from P&P mills proved to be an effective and promising technique.  相似文献   

19.
Pilot-scale struvite crystallization tests using anaerobic effluent from potato processing industries were performed at three different plants. Two plants (P1 & P2) showed high phosphate removal efficiencies, 89 ± 3% and 75 ± 8%, resulting in final effluent levels of 12 ± 3 mg PO43−-P L−1 and 11 ± 3 mg PO43−-P L−1, respectively. In contrast, poor phosphate removal (19 ± 8%) was obtained at the third location (P3). Further investigations at P3 showed the negative effect of high Ca2+/PO43−-P molar ratio (ca. 1.25 ± 0.11) on struvite formation. A full-scale struvite plant treating anaerobic effluent from a dairy industry showed the same Ca2+ interference. A shift in the influent Ca2+/PO43−-P molar ratio from 2.69 to 1.36 resulted in average total phosphorus removal of 78 ± 7%, corresponding with effluent levels of 14 ± 4 mg Ptotal L−1 (9 ± 3 mg PO43−-P L−1). Under these conditions high quality spherical struvite crystals of 2-6 mm were produced.  相似文献   

20.
An integrated treatment method based on magnesium salt extraction followed by chemical oxidation was used for the treatment of a veterinary antibiotic, oxytetracycline (OTC) contaminated cow manure since animal manure can be an important source for antibiotic pollution in the environment. Pretreatment with magnesium salt enhanced the efficiencies of subsequent oxidation processes by extracting 63.9% of OTC from the manure thereby making it more favorable for oxidation with the hydroxyl radicals produced by the Fenton and ozone oxidation processes. Both the 24 h Fenton oxidation process with 434 mM H2O2 and 43.4 mM Fe2+ doses and the 1-h ozonation process with an applied ozone dose of 2.5 mg min− 1 provided more than 90% OTC removal from the manure slurry. However, the second-order OTC removal rate constant of Fenton process (119 M− 1s− 1) was remarkably lower than that obtained with the ozonation process (548 M− 1s− 1). The oxidant dose was a significant factor for the efficiency of the Fenton treatment but not for the ozone treatment. The efficiencies of both the Fenton and ozone oxidation processes were not affected by the pH adjustment of the manure slurry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号