1.
卢明伟 《净水技术》2007,26(5):68-70
主要研究用固相萃取法富集和高效液相色谱法测定水中甲萘威的可行性,此法测定水中甲萘威的最低检测限为0.005 mg/L,相对标准偏差为RSD(n=7)≤3%,平均加标回收率为98.0%,适合于地表水及生活饮用水中甲萘威的检测。  相似文献   

2.
李辉  石志红 《广东化工》2010,37(6):106-106,122
文章采用固相萃取结合高效液相色谱法测定了高温炮制药材中的丙烯酰胺含量。该方法使用水提取样品中的丙烯酰胺,用Oasis HLB固相萃取柱萃取,Bond Elut PRS柱净化,HC-75H+色谱柱分离,紫外检测器于210nm测定其含量。方法检出限为35μg·kg-1,回收率在98%~101%之间,样品平行测定结果的相对标准偏差小于6.7%。实验结果表明文章所建立的方法具有操作简单、准确可靠、干扰少等特点,已成功地用于15种高温炮制药材中丙烯酰胺的检测。  相似文献   

3.
高效液相色谱法测定化妆品中的保泰松   总被引:1,自引:0,他引:1  
建立了化妆品中保泰松的高效液相色谱分析法.采用甲醇超声提取样品,氨基固相小柱净化富集,以C18色谱柱(4.6 mm×250 mm,5μm)分离,流动相为20 mmol/L乙酸铵水溶液、甲醇和乙腈,流速1.0 mL/min,检测波长270 nm,柱温25℃,进样量10 μL.该方法的检出限为2.0 mg/kg,线性范围0.2~100.0μg/mL,加标回收率86.1% ~90.5%,相对标准偏差为5.79%~9.21%.  相似文献   

4.
固相萃取和高效液相色谱法测定水果中的糖   总被引:6,自引:0,他引:6  
研究了高效液相色谱法测定水果中的糖。水果样品的糖提取液用WatersSep Pak C1 8固相萃取小柱预分离 ,以WatersSugar Pak- 1 钙型阳离子交换柱为固定相 ,0 .0 5 g·L- 1 EDTA钙钠水溶液为流动相分离 ,示差折光仪为检测器检测。蔗糖、葡萄糖和果糖的检测限分别为 2mg/L、4mg/L和 4mg/L ,相对标准偏差在 0 .76%~1.8%之间 ,标准回收率在 97%~ 10 3 %之间。方法用于几种水果样品的测定 ,结果满意。  相似文献   

5.
建立了不同基质化妆品中15种卡因类局麻药物含量测定的固相萃取-高效液相色谱分析方法.不同基质样品经不同溶剂提取,MCX固相萃取净化,经C18色谱柱(250?mm×4.6?mm×5μm)分离,流动相采用甲醇-0.01?moL/L磷酸氢二钠水溶液(磷酸调pH 7.0)梯度洗脱,流速1.0?mL/min,检测波长230?nm...  相似文献   

6.
固相萃取-反相高效液相色谱法测定地钱中的芹菜素   总被引:5,自引:0,他引:5  
建立了地钱中芹菜素含量的测定方法。样品用80%乙醇水溶液提取后,用以硅胶为固定相的固相萃取柱纯化,洗去杂质后的流出液作为反相高效液相色谱法测定用的供试液。结果表明,在1 60~12 80mg·L-1范围内,芹菜素进样量与峰面积响应值呈良好的线性关系,r=0 9995;回收率为98 71%~103 20%,RSD为1 6%(n=5)。该法简便快速,结果准确可靠,重复性好,可用于地钱中芹菜素的质量测定。  相似文献   

7.
建立了饮用水中呋喃丹含量的测定-固相萃取高效液相色谱法,最佳仪器条件为流动相甲醇和水44∶55,波长:210 nm;柱流量为0.90 m L/min。检测方法线性方程相关系数0.9992,最低检出浓度0.0358μg/L,平均加标回收率85.0%~130%。该方法操作简单,适用于水中呋喃丹的测定。  相似文献   

8.
利用反相高效液相色谱法建立了同时测定化妆品中13种防晒剂含量的检测方法。样品首先用5 mL二氯甲烷进行溶解,超声提取30min,经过硅胶固相萃取柱(500 mg,6 mL)净化,用5 mL正己烷-二氯甲烷(1∶1,V/V)洗脱淋洗,收集淋洗液上机。以Diamonsil C18柱(250 mm×4.6mm,5μm)为分离色谱柱,甲醇和0.5%(v/v)甲酸水溶液为流动相,梯度洗脱,以311 nm和254 nm为检测波长进行定性,外标法定量。各组分在0.5~1000 mg/L范围内成线性关系,相关系数0.99,平均回收率在84.96%~108.62%,相对标准偏差(n=6)为1.39%~7.65%。该方法样品分离效果好、成本低、回收率和重现性好,适用于化妆品中13种防晒剂的同时测定。  相似文献   

9.
吴海鹏 《净水技术》2013,(6):56-59,78
采用固相萃取-高效色谱法测定水中酚类。通过正交试验和验证试验探讨固相萃取技术富集水中7种酚类各种因素的影响,优化固相萃取的条件。优化得到的固相萃取条件:样品的pH为2、选择Oasis HLB固相萃取色谱小柱、流速为5mL/min、洗脱溶剂为四氢呋喃、洗脱体积为2mL,分2次洗脱。使用该方法的加标回收率为94.2%~105.1%,相对标准偏差为1.2%~3.9%,检出限为0.1~0.5μg/L。固相萃取-高效液相色谱法不仅各组分的回收率和灵敏度高,而且具有操作简便、溶剂用量少的特点,符合水中酚类测定的要求。  相似文献   

10.
建立了以固相萃取(SPE萃取盘)-液相色谱法测定生活饮用水中莠去津的方法.该方法在0.05 mg/L~5.00 mg/L内线性良好,R值为0.9999,相对标准偏差为1.9%~3.0%,方法检出限为0.003μg/L,加标回收率为96.0%~98.0%,精密度良好,可以很好地对莠去津进行分离.因此,此法可以基本满足生活...  相似文献   

11.
高效液相色谱法测定水中痕量丙烯酰胺   总被引:2,自引:0,他引:2  
建立旋转蒸发浓缩固相萃取与高效液相联用测定水中痕量丙烯酰胺的方法。水样经旋转蒸发浓缩活性炭固相萃取柱净化后进行高效液相色谱分析,流动相为甲醇:水(10∶90),流速为0.8 mL/min,进样量为20μL,检测波长为210 nm,丙烯酰胺标准溶液介质为超纯水。试验表明:在同等条件下采用超纯水配制标准丙烯酰胺溶液进行高效液相测定的灵敏度比用甲醇配制的高5倍,线性范围为5~250μg/Lr,=0.999 8;在浓缩100倍的条件,丙烯酰胺回收率为83% ̄95%,水样最低检测限为50 ng/L。该方法经济、简单、灵敏、准确,可向常规实验室推广。  相似文献   

12.
高效液相色谱法测定化妆品中的苯氧异丙醇   总被引:2,自引:0,他引:2  
以超声辅助提取法对不同基质类型的化妆品样品进行预处理,采用高效液相色谱法测定化妆品中的苯氧异丙醇,色谱条件为:Kromasil C18色谱柱(250 mm×4.6 mm i.d.,5μm),流动相为V(水)∶V(乙腈)∶V(甲醇)∶V(四氢呋喃)=60∶25∶10∶5的混合溶液,流速1.2 mL/min,检测波长268 nm,柱温30℃。结果表明,在此条件下苯氧异丙醇在1.0~200.0μg/mL范围内与相应的峰面积具有良好的线性关系(相关系数r=0.999 9),线性回归方程为A=74 280ρ-23 780,回收率为95.6%~102.4%,RSD为0.66%~1.05%。  相似文献   

13.
Herein, we report a magnetic molecularly imprinted polymers (m‐MIPs) using Fe3O4 as a magnetic component, carvedilol as a template molecule for the solid‐phase extraction (MISPE) as the sample clean‐up technique combined with high‐performance liquid chromatography (HPLC) and for the controlled release of carvedilol at different pH values of 1.0 (simulated gastric fluid), 6.8 (simulated intestinal fluid), and 7.4 (simulated biological fluid). The adsorption kinetics was modeled with the pseudo‐first‐order and pseudo‐second‐order kinetics, and the adsorption isotherms were fitted with Langmuir and Freundlich models. The performance of the m‐MIPs for the controlled release of carvedilol was assessed and results indicated that the magnetic MIPs also have potential applications in controlled drug release. Furthermore, the m‐MIPs were applied to the extraction of carvedilol from human blood plasma samples. Carvedilol can be quantified by this method in the 2–350 μg L?1 concentration range. The limit of detection and limit of quantification in plasma samples are 0.13 and 0.45 μg L?1. The results from HPLC showed good precision (3.5% for 50.0 μg L?1) and recoveries (between 85 and 93) using m‐MIP from human plasma samples. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014 , 131, 41209.  相似文献   

14.
建立了高效液相色谱—二极管阵列检测器(HPLC-DAD)测定化妆品中肌肽含量的方法。样品在破乳剂存在的条件下,用纯水经超声波提取30 m i n,在3 000 r/m i n条件下离心1 0 m in,采用Prevail~(TM)Carbohydrate ES色谱柱(250 mm×4.6 mm,5μm),以甲醇与乙酸水溶液(pH 3.5)作为流动相,以1.0 mL/min进行等度洗脱,检测波长为210 nm,柱温25℃。结果显示,肌肽在0.2~20.0 mg/L呈良好的线性关系,相关系数为0.999 9,保留时间和峰面积的相对标准偏差均小于0.5%,加标回收率为93.33%~108.64%,检出限为0.02mg/L,定量限为0.07mg/L。  相似文献   

15.
采用反相高效液相色谱法测定化妆品中巯基乙酸的含量。色谱条件为:Kromasil C18(250 mm×4.6 mm,5μm)色谱柱,流动相为V(乙腈)∶V(0.01 mol/L KH2PO4溶液(磷酸调pH=2.5))=10∶90的混合溶液,流速1.0 mL/min,检测波长215 nm,柱温30℃,进样量20μL。结果表明,此条件下巯基乙酸在5.0~150.0μg/mL质量浓度范围内与峰面积线性良好,线性回归方程为Y=5 100X-13 400(r=0.999 8),平均回收率在98.4%~100.8%,RSD为0.09%~0.84%。  相似文献   

16.
采用反相高效液相色谱法测定化妆品中的3-O-乙基维生素C,色谱条件:SH IMADZU Sh im-pack VP-C18ODS(150 mm×4.6 mm,5μm)色谱柱;C18ODS保护柱芯;流动相V(甲醇)∶V(0.025 mol/L KH2PO4)=20∶80;流速:1.0 mL/m in;柱温:30℃;紫外检测器检测,检测池温度:40℃,波长:254 nm。结果表明,在此条件下,3-O-乙基维生素C在0~100 mg/L与相应的峰面积具有良好的线性关系(r=0.999 2),线性回归方程为A=31.170 3,ρ回收率在97.75%~100.60%,方法精密度RSD约为2.6%(n=5)。  相似文献   

17.
用反相高效液相色谱法测定卷柏提取物中的穗花杉双黄酮。结果表明:穗花杉双黄酮在质量浓度为41.2mg/L~206mg/L时,峰面积Y与其质量浓度X的线性关系良好,回归方程为Y=547.028X 15.4895(r=0.9999),最低检测限为2.0μg/L;穗花杉双黄酮的平均回收率为99.42%(n=3),相对标准偏差RSD为0.79%;连续进样、日内进样和日间进样所得检测结果的RSD分别为0.12%、0.11%和0.11%。  相似文献   

18.
高效液相色谱法测定化妆品中苯扎氯铵   总被引:2,自引:0,他引:2  
采用高效液相色谱法测定化妆品中苯扎氯铵的含量。色谱条件为:Agilent Zorbax CN柱(250 mm×4.6 mm i.d.,5μm),流动相为V(乙腈)∶V(0.1 mol.L-1醋酸铵缓冲溶液(冰醋酸调pH=5.0))=70∶30的混合溶液,流速1.0 mL.min-1,检测波长260 nm,柱温25℃,进样量20μL。结果表明,该方法的检出限为130μg.g-1,线性范围为5~100 mg.L-1,回收率为92.0%~110.6%,RSD为0.32%~2.10%。  相似文献   

19.
建立了测定化妆品中4种防腐剂(脱氢乙酸、氯苯甘醚、4-羟基苯甲酸苯酯和4-羟基苯甲酸苄酯)的高效液相色谱分析方法。采用Diamonsil C18柱(250 mm×4.6 mm,5μm),以甲醇-0.1%甲酸水溶液作为流动相进行梯度洗脱,样品经甲醇-水超声提取30 min后用紫外可见可变波长检测器检测。结果表明,4种防腐剂在12.5 min内基线分离,相关系数r0.998,平均回收率为88.5%~102.7%,日内精密度RSD3.1%,日间精密度RSD3.7%。该方法可用于化妆品中4种防腐剂的分析。  相似文献   

20.
采用高效液相色谱测定化妆品中6种四环素类抗生素(盐酸美满霉素、二水土霉素、盐酸四环素、盐酸金霉素、盐酸多西环素、氯霉素)。结果表明,在ZORBAX SB-C18(4.6 mm×150 mm,5μm)色谱柱上,以乙腈、甲醇和10 mmol/L三氟乙酸作为流动相,检测波长268 nm,流速为1.0 mL/min,柱温30℃,可以较好的分离和测定化妆品中6种四环素类抗生素。该方法检测出的6种四环素类抗生素的相对标准偏差为0.22%~2.1%,回收率为90%~99%。  相似文献   