The most serious accidents with 120/240-V appliances are probably those involving electric shock and fire. To aid in the investigation of such incidents, some fundamental concepts are presented for the accident investigator. For electric shock cases a knowledge of the effects of electricity on the human body and the electrical parameters related to these effects is important. Since most shock cases involve a question as to the path of current to ground or whether the grounding was proper, present day grounding procedures are described for appliances. To aid in investigations of accidents involving older equipment or systems, a history of the National Electrical Code's (NEC) grounding requirements and allowable use of double insulation for cord- and plug-connected equipment is included. In the investigation of fires of possible electrical origin, the investigator is usually confronted with arc damage that either caused the fire or was caused by the fire. A discussion of the fundamentals of electric arcs and of circuit protection is presented to aid in this determination. 相似文献
2.
3.
对几台240MVA/220kV双绕组升压变压器的空载损耗、空载电流和短路阻抗这几个重要参数的试验数据和设计计算值进行了比较与分析,得出了这些参数的一些经验系数. 相似文献
4.
略论240MVA/330KV变压器短路事故及变压器轴向失稳 总被引:7,自引:2,他引:5
分析了240MVA/330KV自耦变压器“轴向失稳”的事故原因,提出了提高变压器抗短路能力的建议。 相似文献
5.
6.
文章在分析电压互感器二次回路压降特征基础上,阐述了对二次回路进行改造、维护以达到减小二次回路压降的技术措施。 相似文献
7.
针对继电保护工作中经常出现的未执行互感器二次回路反事故措施的问题,探讨了执行反事故措施的必要性及对反事故措施的一些理解和新的看法。 相似文献
8.
互感器二次负荷调查统计与分析 总被引:1,自引:0,他引:1
国网公司系统连续发生多起220~500 kV电力互感器损坏事故,对电网安全运行带来了十分严重的影响。针对这些事故,国网公司开展互感器二次负荷调查统计工作,共涉及9个省市电力公司的18个220 kV至500 kV变电站。通过现场实测数据统计分析,表明互感器二次负荷绝大部分运行在25%额定负载之下,二次绕组额定容量不满足各种相关技术规程。分析论证了选择过大的二次绕组额定容量,将严重影响互感器计量、测量、保护等性能,同时导致互感器体积和重量过于偏大,造价偏高,不符合环保和绿色电力的要求,而且造成互感器的综合特性变差,包括电气性能和机械性能下降。最后提出了降低二次负荷及减少二次绕组的设计选型原则,并建议对互感器相关标准和规范开展修订研究。 相似文献
9.
10.
11.
探讨了电流互感器的二次回路在实际接线和运行维护中存在的诸多困惑和误区,指出了正确接入电流互感器二次回路的方法和日常维护的必要性。 相似文献
12.
Seung-Yo Lee Pfaelzer A.G. van Wyk J.D. 《Industry Applications, IEEE Transactions on》2007,43(2):520-530
In this paper, thermal analysis for a 42-V/14-V bidirectional dc/dc converter with integrated inductors is performed. An interleaved dc/dc converter system with four channels was chosen for the automotive-converter topology with 42-V/14-V dual-output voltages. Coupled inductors were designed and used for the four-channel dc/dc converter. A 3-D thermal model based on finite-element modeling using I-DEAS is presented and the thermal behavior of the dc/dc converter system is simulated and analyzed. The thermal model includes a printed circuit board, integrated inductors, a heat sink, and switching devices (MOSFETs). The analyzed thermal result can help to design a converter system under severe ambient-temperature conditions 相似文献
13.
互感器二次压降及二次负荷直接关系到电能计量的误差,是电力系统必须定期检定的项目。本文研制了一套用于电力技术人员培训用的模拟测试系统,采用三相电压电流源来模拟互感器的二次侧输出,用电阻、电抗序列模拟互感器的二次负荷及压降,接线方式包括三相三线制和三相四线制两种。以数字信号处理器(TMS320F206)为核心控制器,来控制各个模拟设备的参数,并通过A/D转换和运算放大等电路来采集电压、电流、功率因数等参数,整个系统由上位机软件进行控制,采用RS485串口通讯协议。实践表明该系统具有较好的稳定性和可靠性,模拟测试的各项指标符合现场测试的技术要求。 相似文献
14.
介绍高压直流输电系统中二次谐波的传递过程以及由此可能引发的谐波不稳定性。实验研究变压器绕组中直流电流导致的二次谐波电流,得出了励磁电流各次谐波分量、峰值与绕组中直流电流的关系。结果表明,二次谐波分量与直流呈线性关系。 相似文献
15.
16.
电流法能够有效检查电流互感器的变比情况。以下几例变比异常现象就是采用升电流的试验方法有效地找出了故障的原因。
对如下试品作变比核定试验。试品型号:LB6-110W2;额定电压:110kV;额定频率:50Hz;额定电流比:2×600/5A;额定绝缘水平:126/230/550kV:额定短时热电流:50kM3s:额定动稳定电流:125kA:一次联结:并联。 相似文献
17.
介绍了电流互感器实际二次阻抗的现场测试、计算方法。该方法所需设备少、重量轻,操作简便;不需新增专用设备,不需三相电源;通用性强,适用于各种形式接线的电流互感器。 相似文献