首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 218 毫秒
1.
目的 建立纸质食品接触材料中亚甲基双硫氰酸酯迁移量的高压液相色谱测定方法。方法 食品模拟物(水、3%乙酸-水溶液、10%乙醇-水溶液和橄榄油)中的亚甲基双硫氰酸酯通过高压液相色谱进行分离, 采用二极管阵列检测器进行测定。水基食品模拟物直接进样, 油基食品模拟物经乙腈萃取后进样, 外标法定量。结果 3种水基食品模拟物中, 亚甲基双硫氰酸酯在0.5~50 mg/L范围内线性关系良好, 定量下限为0.5 mg/L, 平均回收率为88.2%~97.4%, 相对标准偏差为0.44%~6.54%; 油基食品模拟物中, 亚甲基双硫氰酸酯在1.0~20 mg/kg范围内线性关系良好, 定量下限为1.0 mg/kg, 平均回收率为99.3%~104.7%, 相对标准偏差为0.75%~3.15%。结论 该方法准确、简便、快速, 可用于纸质食品接触材料中亚甲基双硫氰酸酯迁移量的实际检验工作。  相似文献   

2.
目的 建立液相色谱-串联质谱外标法测定食品接触材料中双酚F和双酚S迁移量的分析方法。方法 样品经水、4%乙酸、10%乙醇、20%乙醇、50%乙醇、95%乙醇和橄榄油等7种食品模拟液浸泡试验后,浸泡液经过滤后进样,以甲醇-水为流动相,经过T3色谱柱分离,用外标法在负离子模式下以电喷雾电离多反应监测模式进行定量分析。 结果 6种食品模拟物(除橄榄油外)中双酚F和双酚S分别在10.0~200 μg/L和0.500~10.0 μg/L浓度范围内有好的线性,相关系数r均大于0.9995,方法检出限分别为0.002 mg/kg和0.0001mg/kg,定量限分别为0.01mg/kg和0.0005mg/kg,在食品模拟物橄榄油中双酚F和双酚S分别50.0~750 μg/kg和2.50~37.5 μg/kg浓度范围内线性很好,相关系数r均为0.9999,检出限分别为0.01mg/kg和0.0005mg/kg,定量限分别为0.05mg/kg和0.0025mg/kg。在三个浓度水平双酚F加标回收率为90.4%~108%,相对标准偏差(n=6)在0~5.27%之间,双酚S加标回收率为84.4%~107%,相对标准偏差(n=6)在0~4.60%之间。结论 该方法操作简便、灵敏度高、准确性好,能满足食品接触材料中双酚F和双酚S的迁移量的检测。  相似文献   

3.
目的 建立食品接触材料及制品电饭煲内胆中一种氟迁移量的快捷、准确的检测方法。方法 样品经4%(体积分数)乙酸、95%(体积分数)乙醇这两种模拟液进行迁移实验后,建立了离子选择电极法测定电饭煲内胆中氟迁移量的含量。结果 目标物氟迁移量在两种模拟液0.005~0.1 μg/mL[数字与单位间空格]范围内线性良好,r2≥0.9979;3个添加水平:0.05 mg/kg[]、0.15 mg/kg、0.5 mg/kg进行加标回收实验,回收率在80.0~94.0%之间,相对偏差RSD (Relative Standard Deviation[文中首次出现的英文简称需要有中英文全称,请补充,下同])在1.02%~3.07%之间。结论该方法具有简单、快捷、灵敏度高、选择性好并且准确等优点,适用于食品接触材料及制品电饭煲内胆中氟迁移量的测定。  相似文献   

4.
目的建立食品接触材料中12种丙烯酸酯单体迁移量的高效液相色谱检测方法。方法依据欧盟指令(EU)No.10/2011,采用水性模拟物3%乙酸、10%乙醇、20%乙醇、50%乙醇和油性模拟物异辛烷浸泡食品接触材料,将得到的模拟物通过C18色谱柱(150 mm×4.6 mm,5μm)分离,保留时间定性,峰面积定量。结果 12种单体在0.3~60.0 mg/L(水性模拟物)及0.6~120.0 mg/L(异辛烷模拟物)的浓度范围内呈良好线性,相关系数r2大于0.9993。加标回收率在88.2%~109.3%之间,相对标准偏差为1.19%~7.48%,方法的检出限和定量限分别在0.01~0.12 mg/L和0.03~0.24 mg/L之间。结论该方法前处理简便,分离度好,分析灵敏度高,满足食品接触材料中12种丙烯酸酯单体迁移量的分析要求,并用该方法测定了6批次食品接触材料中丙烯酸酯类单体的迁移水平,甲基丙烯酸甲酯为主要检出。  相似文献   

5.
总迁移量是指食品包装迁移到食品(或食品模拟物)中所有不挥发物质的总量。为了研究食品接触用硅橡胶密封垫圈总迁移量的迁移规律,从生产企业抽取5个食品接触容器硅橡胶密封垫圈,用水、醋、酒和油模拟液进行三次迁移试验。结果表明:硅橡胶密封垫圈三次迁移试验均有不挥发物质析出,其中第一次总迁移量最大,第二、第三次逐次减少。油模拟液浸泡后的总迁移量远远高于其它三种模拟液的总迁移量。  相似文献   

6.
目的 建立了高效液相色谱-串联质谱(HPLC-MS/MS)法同时测定从聚对苯二甲酸乙二醇酯/聚乙烯(polyethylene glycol terephthalate/ polyethylene, PET/PE)复合食品接触材料迁移至超纯水、3%乙酸、10%乙醇和橄榄油这4种食品模拟物中16种抗氧化剂的特定迁移量。方法 考察了不同实验条件对橄榄油食品模拟物中16种抗氧化剂的提取效果。采用ODS色谱柱梯度洗脱分离,以甲醇和水作为流动相梯度洗脱,在正、负离子模式下以电喷雾电离多反应监测(MRM)模式进行定性和定量分析,外标法定量。结果 该方法测定的16种目标化合物在相应的浓度范围内具有良好的线性关系,相关系数均大于0.995,水性食品模拟物(超纯水、3%乙酸、10%乙醇)的定量限为0.1~1.3 ng/mL,橄榄油食品模拟物的定量限为0.5~3.0 μg/kg。在0.5~10.0 ng/mL和2.0~25.0 μg/kg加标水平下的平均回收率为81.0%~112.5%,相对标准偏差(RSD)为0.4%~9.1%。结论 该方法灵敏度高,定量限低,满足PET/PE复合食品接触材料中抗氧化剂特定迁移量的检测要求。  相似文献   

7.
建立了一种采用超高效液相色谱等度洗脱法(Ultra performance liquid chromatography-isocratic elution,UPLC-IE)分析无烟气烟草制品及卷烟烟丝中8种重要羰基化合物的方法。使用4%乙酸水溶液于80℃水浴振荡萃取主要羰基化合物,采用0.1%甲酸水溶液-0.1%甲酸乙腈溶液(50︰50,V/V)为流动相,使用超高效液相色谱等度洗脱法进行分离。结果表明:(1)8种羰基化合物在0.02~10.00 mg/L范围内线性关系良好(R~20.999),加标回收率在80%~103%之间,平均相对标准偏差(RSD)小于9.0%,检出限(LOD)为0.14~0.25 mg/kg。(2)该方法检测时间显著缩短。(3)该方法更符合绿色分析要求。(4)4个无烟气烟草制品中甲醛、乙醛和丙酮均有检出,丙烯醛在部分样品中有检出,丙醛、巴豆醛、丁酮和丁醛在CRP1、CRP2和CRP3中均未检出;11个卷烟烟丝中8种羰基化合物均有不同程度检出。  相似文献   

8.
利用超高效液相色谱-串联质谱,建立了食品接触纸中多菌灵、戊唑醇、丙环唑、环丙唑醇等10种杀菌剂迁移量的测定方法。结果表明,此方法对10种杀菌剂迁移量的水基食品模拟物方法检出限为0.0005~0.025 mg/L,橄榄油方法检出限为0.0004~0.02 mg/kg;平均回收率为71.7%~117.7%,相对标准偏差为0.3%~5.2%。此方法灵敏度高,具有较好的准确性和精密度,对食品接触纸的安全风险监测有一定的意义。  相似文献   

9.
气相色谱法分析卷烟烟气中的醛类化合物   总被引:5,自引:1,他引:5       下载免费PDF全文
本文研究了采用毛细管气相色谱仪分析卷烟烟气中醛类化合物的方法。在标准条件下吸烟,使卷烟烟气通过装有2,4-二硝基苯肼(DNPH)衍生化试剂酸性溶液的捕集装置,烟气中的醛类化合物与DNPH反应,生成稳定的2,4-二硝基苯腙衍生物,经三氯甲烷萃取,并在氮气保护下浓缩后,采用配备氮-磷检测器(NPD)的毛细管气相色谱仪进行分析。本文评价了该方法测定卷烟烟气中甲醛、乙醛和丙烯醛的重复性及回收率,并采用内标法定量测定了9种牌号卷烟烟气中的甲醛、乙醛和丙烯醛的输送量以及卷烟滤嘴对甲醛的截滤效率。采用气/联用仪(GC/S)和标样加入法鉴定出卷烟烟气中的12种醛类化合物。该方法操作简便,重复性好,回收率高,适用于卷烟烟气中醛类化合物的分析。   相似文献   

10.
目的建立气相色谱-质谱法测定食品接触材料中润滑剂(油酸酰胺、硬脂酰胺、芥酸酰胺、山嵛酰胺)在脂类食品模拟物中迁移量的方法。方法采用异辛烷、95%乙醇、改性聚苯醚3种试验介质替代脂类食品试验,用三氟乙酸酐衍生后,采用气相色谱-质谱法测定。结果油酸酰胺、硬脂酰胺在0.2~20 mg/L范围内线性良好,芥酸酰胺、山嵛酰胺在1.0~30 mg/L范围内线性良好,方法定量限为0.026~0.14 mg/L,加标回收率为76.2%~97.3%,相对标准偏差(RSD)为1.2%~6.3%。结论本法简便、快速、准确,灵敏度及精密度较高,适用于食品接触材料中润滑剂在脂类食品模拟物中迁移量的测定。  相似文献   

11.
目的建立食品塑料包装材料中限用紫外吸收剂(UV-0、UV-9、UV-71、UV-326、UV-327、UV-234)和抗氧化剂(2246、425、TH-1790、3114和1076)迁移量的超高效液相色谱(ultra performance liquid chromatography,UPLC)测定方法。方法优化仪器条件及模拟液萃取条件,考察超纯水、3%乙酸水(V:V)溶液、10%乙醇水(V:V)溶液及95%乙醇水(V:V)溶液等4种食品模拟物中紫外吸收剂和抗氧化剂的迁移量,并将建立的方法用于市售样品迁移量的检测。结果 11种目标物质在相应的浓度范围内线性关系良好,相关系数r~2大于0.9992,方法检出限为0.5~2.0 mg/L;平均加标回收率为81.2%~113.2%,相对标准偏差(n=6)为2.8%~8.5%。结论该检测方法灵敏、准确,满足欧盟指令(EU)No.10/2011和GB 9685-2008对食品塑料接触材料及制品中紫外吸收剂和抗氧化剂特定迁移量(SML)的限量要求,适用于食品塑料包装材料中紫外吸收剂和抗氧化剂的迁移量的测定。  相似文献   

12.
采用溶剂提取-气相质谱联用法(Solvent extraction-gas chromatography/mass spectrometry,solvent extraction-GC/MS)测定食品接触用硅橡胶中八甲基环四硅氧烷(Octamethylcyclotetrasiloxane,D4)、十甲基环五硅氧烷(Decamethylcyclopentasiloxane,D5)和十二甲基环六硅氧烷(Dodecamethylcyclohexasiloxane,D6)等3种环硅氧烷的含量,并研究硅橡胶烤盘中D4~D6向油性食品模拟物中的迁移规律。采用衰减全反射-傅里叶变换红外光谱(Attenuated total reflectance-Fourier transform infrared spectroscopy,ATR-FTIR)分析方法确定硅橡胶的材质,以优化的提取溶剂正己烷和超声提取时间30 min,通过GC/MS检测3种不同用途的9个硅橡胶品牌产品中D4~D6的含量。以其中一种硅橡胶烤盘进行单面迁移试验。结果表明:D4~D6在0.5~20.0 μg/mL质量浓度范围内线性良好,决定系数R2大于0.9961,且D4~D6的检出限均小于为11.2 ng/mL,定量限均小于37.2 ng/mL。通过加标验证,D4~D6的平均回收率为85.20%~98.12%,相对偏差RSD为2.17%~4.27%(n=6)。硅橡胶奶嘴和高压锅密封圈中D4~D6含量较少,而硅橡胶烤盘中含量最多,其D4~D6的均值分别为175.08、824.12和901.17 mg/kg。通过迁移试验,发现硅橡胶烤盘在60 ℃油性食品模拟物95%乙醇中达到迁移平衡时,D4~D6的迁移率分别为71.36%、57.03%和49.31%。这表明D4~D6会迁移到油性食品中,且分子量较小的D4更易迁出,其安全性不可忽视。  相似文献   

13.
Polyadipate plasticizers can be present in the polyvinylchloride (PVC) gaskets used to seal the lids of glass jars. As the gaskets can come into direct contact with the foodstuffs inside the jar, the potential exists for polyadipate migration into the food. The procedure and performance characteristics of a test method for the analysis of polyadipates in food simulants (3% aqueous acetic acid and 10% aqueous ethanol) and the volatile test media used in substitute fat tests (isooctane and 95% aqueous ethanol) are described. The PVC gaskets were exposed to the food simulants or their substitutes under standard test conditions. Studies were initially carried out using direct measurement of the polyadipate oligomers by liquid chromatography with time-of-flight mass spectrometric detection (LC-TOF-MS) but this was not practical due to the number of peaks detected. Instead, the migrating polyadipates were hydrolysed to adipic acid and measured by liquid chromatography with tandem mass spectrometric detection (LC–MS/MS). The amount of polyadipate that this measurement of adipic acid represents was then calculated. Method performance was assessed by analysis of gaskets from two types of jar lids by single-laboratory validation. Linearity, sensitivity, repeatability, intermediate reproducibility and recovery were determined to be suitable for checking compliance with the 30 mg/kg specific migration limits for polyesters of 1,2-propane diol and/or 1,3- and/or 1,4-butanediol and/or polypropylene-glycol with adipic acid, which may be end-capped with acetic acid or fatty acids C12–C18 or n-octanol and/or n-decanol. The method was found to be much quicker than previous methods involving extraction, clean-up, hydrolysis, esterification, derivatisation and GC measurement, consequently saving time and money.  相似文献   

14.
目的 探讨高压液相色谱法测定食品接触材料水性模拟液中2,4-二羟基二苯甲酮的方法。方法 食品接触材料经水、10%乙醇(v/v)、20%乙醇(v/v)、50%乙醇(v/v)以及3%乙酸(w/v)5种不同水性模拟液提取后, 以Agilent HC-CN为分析柱, 甲醇: 水(55: 45, v/v)为流动相, 经UV检测器(?=290 nm) 进行定量分析。结果 5种不同水性模拟液中2,4-二羟基二苯甲酮在0.5~10.0 mg/L浓度范围内线性关系均良好(r=0.9999), 检测限(S/N=3)均为0.02 mg/L。在低、中、高3个不同添加水平下进行加标回收实验, 2,4-二羟基二苯甲酮的平均回收率为84.0%~96.9%, RSD(n=6)为0.85%~4.60%。结论 本方法简单、快速、准确, 完全能够满足食品接触材料日常检验的需要。  相似文献   

15.
目的建立高效液相色谱法测定5种食品模拟物中偏苯三甲酸酐迁移量的分析方法。方法以4%(V:V)乙酸溶液、10%(V:V)乙醇溶液、20%(V:V)乙醇溶液、50%(V:V)乙醇溶液、橄榄油分别模拟酸性、水性、酒精类以及油脂类食品,通过高效液相色谱法(high performance liquid chromatography HPLC)测定食品模拟物中的偏苯三甲酸的含量,采用外标法定量,计算出偏苯三甲酸酐的迁移量。结果各模拟物中加标回收率为96.7%~104.0%,相对标准偏差为0.2%~3.7%,水基食品模拟物中该方法的检出限和定量限分别为0.2、0.5 mg/L,橄榄油食品模拟物中该方法的检出限和定量限分别为0.2、0.5 mg/kg。结论该方法具有良好的准确度和精密度,可以准确测定各种食品接触材料中偏苯三甲酸酐的迁移量。  相似文献   

16.
本文建立了超声萃取结合液相色谱测定馅料和米面食品中二氧化硫脲的方法。用光谱扫描的方式,确定了二氧化硫脲的检测波长为274 nm;用HILIC-Z的柱子和0.2%(V/V)乙酸水溶液、乙腈为流动相,梯度洗脱可实现对目标物的较好分离;优化确定样品中二氧化硫脲的提取条件:0.1%(V/V)的乙酸水溶液为提取液,采用冰水浴的条件超声30 min。二氧化硫脲在0~250 mg/L的浓度范围内,线性关系良好,相关系数R2=0.9999,检出限0.2 mg/L,定量限0.5 mg/L,空白样品在三个水平(0.5 mg/kg、1 mg/kg、5 mg/kg)的加标回收实验中,回收率95.67%~100.37%,相对标准偏差(RSD)0.53%~4.45%,回收率和RSD均符合方法学要求。样品检测中,紫薯馅料和绿豆馅料中都检出了二氧化硫脲,含量分别是8.30 mg/kg、236.36 mg/kg。本方法具有操作简便,重现性好和准确度高的优点,可用于检测分析食品中二氧化硫脲。  相似文献   

17.
Besides aliphatic gasoline, ethanol-blended gasoline intended for use in small utility engines was recently introduced on the Swedish market. For small utility engines, little data is available showing the effects of these fuels on exhaust emissions, especially concerning aldehydes and ketones (carbonyls). The objective of the present investigation was to study carbonyl emissions and regulated emissions from a two-stroke chain saw engine using ethanol, gasoline, and ethanol-blended gasoline as fuel (0%, 15%, 50%, 85%, and 100% ethanol). The effects of the ethanol-blending level and mechanical changes of the relative air/fuel ratio, lambda, on exhaust emissions was investigated, both for aliphatic and regular gasoline. Formaldehyde, acetaldehyde, and aromatic aldehydes were the most abundant carbonyls in the exhaust. Acetaldehyde dominated for all ethanol-blended fuels (1.2-12 g/kWh, depending on the fuel and lambda), and formaldehyde dominated for gasoline (0.74-2.3 g/kWh, depending on the type of gasoline and lambda). The main effects of ethanol blending were increased acetaldehyde emissions (30-44 times for pure ethanol), reduced emissions of all other carbonyls exceptformaldehyde and acrolein (which showed a more complex relation to the ethanol content), reduced carbon monoxide (CO) and ntirogen oxide (NO) emissions, and increased hydrocarbon (HC) and nitrogen dixodie (NO2) emissions. The main effects of increasing lambda were increased emissions of carbonyls and nitrogen oxides (NOx) and reduced CO and HC emissions. When the two types of gasoline are considered, benzaldehyde and tolualdehyde could be directly related to the gasoline content of aromatics or olefins, but also acrolein, propanal, crotonaldehyde, and methyl ethyl ketone mainly originated from aromatics or olefins, while the main source for formaldehyde, acetaldehyde, acetone, methacrolein, and butanal was saturated aliphatic hydrocarbons.  相似文献   

18.
面制品中过氧化苯甲酰和苯甲酸的测定及热稳性研究   总被引:2,自引:0,他引:2  
建立一种同时测定面制品中过氧化苯甲酰(BPO)和苯甲酸(BA)的高效液相色谱法,采用液氮冷冻干燥,将面制品预处理后采用无水乙醇进行提取BPO及BA后,用Tech Mate C_(18)色谱柱(5μm,250 mm×4.6 mm),以乙腈-乙酸(pH2.8)水溶液等度洗脱,检测波长233 nm,该方法在0.05~200mg/L范围内具有良好的线性特征(R_(BPO)=0.99987,R_(BA)=0.99994)。通过基质加标,BPO回收率介于90.2%~96.5%之间,相对标准偏差介于1.5%~3.4%之间,BA回收率介于91.5%~101.3%之间,相对标准偏差介于1.1%~3.6%之间,LODBA值为0.5 mg/kg,LOD_(BPO)值为0.8 mg/kg,说明该方法可行。同时,模拟样品在煮沸情况下BPO和BA的变化情况,得出BPO热稳性较差,在一定条件下分解产生BA。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号