首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bioluminescent bacteria-based assays can be used for influent wastewater toxicity monitoring for biological wastewater treatment systems. The most thoroughly studied bioluminescent bacteria-based test is the Microtox? assay. However, the response to toxicants of Photobacterium phosphoreum, the marine bacterial strain used in this assay, is different from that of the activated sludge microorganisms. We developed a continuous influent wastewater monitoring system based on the bioluminescent bacterium Shk1, a genetically modified Pseudomonad isolated from the activated sludge in an industrial wastewater treatment plant. The Shk1 toxicity data were correlated with the Microtox? toxicity data for 79 organic compounds and the two toxicity assays were compared. The Shk1 assay is less sensitive than the Microtox? assay and could therefore be more suitable for influent wastewater toxicity monitoring.  相似文献   

2.
Ionic liquids have become leading candidates for replacing many common organic solvents used in the chemical process industry. There is, however, a general lack of toxicology data relevant to wastewater treatment facility microbes for these compounds. In this study, we performed three bacterial-based toxicity assays on several imidazolium-derived compounds as well as the precursor compound 1-methylimidazole. Two of the assays, the Shk1 and Microtox assays, are used as surrogate assays for toxicity to bacterial respiration in activated sludge wastewater treatment plants. The third assay was a direct measure of the effect of toxicity on mixed bacterial culture respiration, using a commercially available consortium of naturally occurring bacteria to obtain IC50 values for direct comparison to the EC50 values from the surrogate assays. The Shk1 assay is based on a genetically engineered bioluminescent Pseudomonas bacterium and is more highly correlated with the respiration inhibition than the Microtox assay. The Shk1 assay gave EC50 values more similar to IC50 values from the bacterial respiration inhibition assay for the compounds tested in this work. The Shk1 EC50 values were similar to that of 1-butanol, an alcohol with an alkyl chain length similar to that of the cation of the tested compounds, which were 1-butyl-3-methylimidazolium bromide ([bmim][Br]), 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim][PF6]), 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, ([bmim][Tf2N]), and the precursor compound 1-methylimidazole, and were generally smaller than those typical of aromatic organic solvents.  相似文献   

3.
The potential benefits prefermentation can provide to biological nutrient removal are measured and compared to the costs of excess oxygen consumption and sludge production incurred by an activated sludge system that utilizes prefermentation, instead of primary clarification. Prefermentation was found to produce superior performance in regards to enhanced biological phosphorus removal. A lower soluble orthophosphorus effluent value [3.2?mg/L for the prefermented activated sludge (PAS) train versus 4.6?mg/L for the control train with primary clarification (PCAS)] and a higher percent phosphorus (% P) content of the biomass (9.0% for the PAS train versus 7.8% for the PCAS train) were both found to be statistically significant (P values of 4.26×10?5 and 0.0082, respectively). In addition statistically significant improvements in denitrification rates and reduced observed yields were observed due to prefermentation. However statistically significant increases in solids inventory and in particular oxygen uptake rates offset these improvements. Waste activated sludge production was slightly higher in the PAS train but was not found to be statistically significant.  相似文献   

4.
Models ranging through simple, intermediate, and International Water Association complex activated sludge models (ASMs) were evaluated to compare their ability to describe biomass growth and substrate removal in an activated sludge system. A membrane-activated sludge bench-scale system was used to treat a complex synthetic wastewater over a wide range of operating conditions, ranging from 1 to 15 days solids retention time and 4 to 12 h hydraulic retention time. Total suspended solids, volatile suspended solids (VSSs), and total and soluble chemical oxygen demands (CODs) were monitored in the influent, the reactor, and the effluent. A variety of substrate removal formulations were used with the simple and intermediate models. Although all models provide excellent prediction of biomass growth, the intermediate model was best. Prediction of substrate removal was good with models that incorporated a nonbiodegradable component in the influent. ASM3 was the best model for predicting effluent soluble COD, but overall, the intermediate model was judged best for prediction of mixed liquor VSS and effluent soluble COD.  相似文献   

5.
A novel municipal wastewater treatment system, consisting of a combination of an upflow anaerobic sludge blanket (UASB) and down-flow hanging sponge (DHS) posttreatment unit, was continuously evaluated for more than three years with raw sewage as an influent. The system was installed at a sewage treatment site and operated at 25±3°C. This paper reports on the results of a long term monitoring of the system. The whole experimental period was divided into three distinct phases with different operating conditions. Organic pollutants were only partially removed in anaerobic UASB pretreatment unit. The remaining organics as well as nitrogenous compounds were almost completely removed by the DHS posttreatment unit. In all phases the system demonstrated removal efficiency consistently over 95% for unfiltered biochemical oxygen demand (BOD), 80% for unfiltered-chemical oxygen demand and 70% for suspended solids. The system produced an excellent effluent quality with only 4–9?mg/L of residual unfiltered BOD. Dissolved oxygen in the final effluent was 5–7?mg/L although no aeration was provided to DHS system. Moreover, excess sludge production from DHS was negligible thus eliminating secondary sludge that is troublesome to dispose off. The system also exhibited substantial stability against twofold hydraulic shock load and fourfold organic shock load. The results suggested that the proposed system may be a competitive solution for municipal sewage treatment under variable conditions.  相似文献   

6.
Color removal from cotton textile processing wastewater by addition of powdered activated carbon (PAC) into a lab-scale activated sludge system was examined. The activated sludge system was continuously operated in different sludge ages (SRTs) and hydraulic retention times (HRTs). SRT = 30?d and HRT = 1.6?d operation resulted in up to 36% color removal and 94% COD removal. PAC was added 100, 200, and 400 mg/L into the activated sludge system under these operating conditions. The results indicated that 100 mg/L PAC was sufficient to remove the maximum color measured (up to 50 m?1) from the wastewater. The addition of PAC did not affect chemical oxygen demand (COD) removal significantly. Oxygen uptake rate (OUR) tests were also performed to investigate the microbial activities controlling the system performance. The average OUR was 74.1 mg/L/h without PAC addition while it was 70 mg/L/h with PAC addition. Adsorbable organic halogens of the effluent wastewater decreased from 400 to 50 μg/L with the addition of PAC. Toxicity dilution factor decreased from 2 to 1.5 with the PAC addition into the activated sludge system.  相似文献   

7.
Toxicity Estimation of Phenolic Compounds by Bioluminescent Bacterium   总被引:1,自引:0,他引:1  
Phenolic compounds are environmentally important due to their extensive use in various industries, presence in wastewaters, and potential toxicity. When phenolic compounds reach the activated sludge processes of publicly owned treatment works, they can cause upsets in the operations of the treatment plants. A continuous toxicity testing system was developed based on the bioluminescent bacterium Shk1. The toxicities of 23 phenolic compounds to Shk1 were studied and the 5 min EC50 values were obtained. Quantitative structure-activity relationship models based on the logarithm of the octanol-water partitioning coefficient [log(Kow)] were established for estimating the toxicity of phenolic compounds and the model validity was verified.  相似文献   

8.
This study demonstrated the use of batch bioreactor experiments as an evaluation tool to determine appropriate influent medium composition and concentration for effective startup of an upflow anaerobic sludge blanket (UASB) reactor. Using seed sludge from a domestic treatment plant, the weight ratio of glucose and volatile fatty acids (VFA) present in the influent synthetic medium was varied and the batch performance was assessed in terms of pH variation during the course of the experiment, chemical oxygen demand (COD) reduction, specific substrate uptake rates, methanogenic activity, and methane yield. The performance was also evaluated by increasing the concentration of influent COD. Medium composition with glucose to VFA weight ratio at or below 2:8 and COD concentration at 11?g/L was determined to be optimum for effective startup of the UASB reactors. Utilization of the optimized influent medium provided a pH variation from 6.5 to 7.8 over the length of the UASB reactor and resulted in granule formation, high methanogenic activity, and methane yield. The evaluation method provided a practical approach to determine the applicability of seed sludge from a particular source and the desired influent characteristics for reduced startup duration in UASB processes.  相似文献   

9.
This study investigated the potential of four full-scale oxidation ditches to accomplish enhanced biological phosphorus removal (EBPR). Despite the fact that none of the tested oxidation ditches were designed to perform EBPR, mixed liquors from all four ditches showed good specific phosphorus release and uptake rates, a typical characteristic of a typical EBPR biomass. The specific phosphorus release rates ranged from 0.042- to 0.254-mg P/mg VSS-d and the specific phosphorus uptake rates ranged from 0.023- to 0.125-mg P/mg VSS-d for the tested full-scale plants. The EBPR potential of one of the full-scale plants (Central Davis Sewer District) was further studied by changing the aeration patterns in the ditch. The mixed liquor in this full-scale plant exhibited good phosphorus release and uptake trends and dissolved phosphorus, as low as 1.26 mg/L, could be accomplished in the final effluent of this plant as a result of this optimization. The long-term feasibility of the EBPR in this full-scale was tested by running a bench-scale EBPR reactor, in which the anaerobic phase was replaced with aerated-anaerobic phase to simulate the mixed liquor environment that exists in Central Davis mixed liquor and, in general, in all oxidation-ditch-type activated sludge configurations. The bench-scale reactor showed consistent EBPR activity in the absence of an anaerobic environment and more than 85% phosphorus removal could be maintained in the reactor for more than 400 days. The intrafloc microanaerobic/anoxic zones, which may be present in the mixed liquor, did not seem to add to the EBPR efficiency under aerated-anaerobic conditions. Cloning and sequencing using Rhodocyclus specific forward primer RHC439 showed the abundance of organisms most closely falling in Rhodocyclaceae family but not related to Candidatus Accumulibacter phosphatis. Simultaneous 4′-6–Diamidino-2–phenylindole (DAPI) staining and fluorescent in situ hybridization (FISH) using RHC439 probe clearly demonstrated the participation of polyphosphate accumulating organism (PAOs) targeted by RHC439 (i.e., in Rhodocyclaceae family). Microautoradiography assisted FISH using RHC439 further confirmed the participation of PAOs in Rhodocyclaceae family.  相似文献   

10.
A hybrid-loop bioreactor system consisting of a packed column biofilm and an aerated tank bioreactor with an effluent recycle was used for biological treatment of 2,4,6 tri-chlorophenol (TCP) containing synthetic wastewater. The effects of sludge age (solids retention time) on chemical oxygen demand (COD), TCP, and toxicity removal performance of the system were investigated for sludge ages between 5 and 30?days, while the feed COD (2600±100?mg?L?1), TCP (370±10?mg?L?1), and the hydraulic residence time (25?h) were constant. Percent TCP, COD, and toxicity removals increased with increasing sludge age resulting in nearly complete COD, TCP, and toxicity removal at sludge ages above 20?days. Biomass concentrations in the packed column and in the aeration tank increased with increasing sludge age resulting in low reactor TCP concentrations, and therefore, high TCP, COD, and toxicity removals. More than 95% of COD, TCP, and toxicity removal took place in the packed column reactor. Volumetric rates of TCP and COD removal increased due to increasing biomass and decreasing effluent TCP and COD concentrations with increasing sludge age. The specific rate of TCP removal was maximum (120?mg?TCP?gX?1?day?1) at a sludge age of 20?days. TCP inhibition was eliminated by operation of the system at sludge age above 20?days to obtain nearly complete COD, TCP, and toxicity removal.  相似文献   

11.
采用"搅拌-曝气-搅拌"间歇曝气运行模式,探索好氧颗粒污泥(AGS)在低碳氮比(1~6)废水中的形成规律及其对污染物的降解效果,旨在为低碳氮比污水的高效处理提供技术支持.当进水碳氮比为1~2.25时,接种污泥表现出明显的不适应,污泥量及颗粒化率增长缓慢,化学需氧量(COD)、总无机氮(TIN)及总磷(TP)的去除率较低...  相似文献   

12.
Carbon tetrachloride (CT) in a synthetic wastewater was effectively degraded in a 2?l upflow anaerobic sludge blanket reactor during the granulation process by increasing the chemical oxygen demand (COD) and CT loadings. The effect of operational parameters such as influent CT concentrations, COD, CT loading, food to mass (F/M) ratio, and specific methanogenic activity (SMA) were also detected during granulation. Over 97% of CT was removed at 37°C, at a COD loading rate of 10?g/L?day. Chemical oxygen demand and CT removal efficiencies of 92 and 88% were achieved when the reactor was operating at CT and COD loading rates of 17.5?mg/L?day and 12.5?g/L?day, respectively. This corresponds to an hydraulic retention time of 0.28?day and an F/M ratio of 0.57?g?COD/g?volatile?suspended?solids?(VSS)?day. In 4?weeks, the seed sludge developed the CT degrading capability that was not very sensitive to shocks. The granular sludge cultivated had a maximum diameter of 2.5?mm and SMA of 1.64?g?COD/g?VSS?day. Glucose biodegradation by CT acclimated anaerobic granules was expressed with competitive inhibition. However the competitive inhibition was not significant since the competitive inhibition coefficient (Ki) was as high as 18.72?mg/L. Kinetic coefficients of k (maximum specific substrate utilization rate), Ks (half velocity coefficient), Y (growth yield coefficient), and b (decay coefficient) were determined as 0.6/day, 1.1?mg/L, 0.23?g?VSS/g glucose-COD, and 0.01/day, respectively, based on growth substrate glucose–COD during CT biotransformation. The CT was treated via biodegradation and this contributed to 89% of the total removal. The removal contributions from biomass adsorption, abiotic transformation, and volatilization were negligible. Adsorption and volatilization accounted for only 0.8 and 0.5% of the total removal, respectively.  相似文献   

13.
Influent and effluent samples originating from two wastewater treatment plants (WWTPs) (treating hospital wastewater and domestic wastewater, Belgium) have been analyzed in order to estimate their steroid hormone content. The natural estrogens estrone (E1), 17β-estradiol (E2), and the synthetic 17α-ethinylestradiol (EE2) together with other steroid hormones progesterone (P) and testosterone (T) metabolites were detected in these samples. The hormone concentrations in both the hospital and the domestic WWTP samples were not significantly different and ranged from <0.2?ng EE2/L to 114?ng EE2/L, from <0.2?ng E1/L to 58?ng E1/L and from <0.2?ng P/L to >100?ng P/L. E2 was detected once at a concentration of 17?ng/L. In the domestic WWTP which comprises a conventional activated sludge treatment in parallel with a membrane bioreactor, no differences in estrogen removal efficiency could be observed for both treatments. In comparison to chemical analysis data, the Yeast Estrogen Screen (YES) appears to underestimate the influent estrogen concentrations, probably due to influent toxicity for the YES. Effluent estrogen concentrations, on the other hand, were overestimated by the YES test, probably due to the presence of other estrogenic compounds in the effluent.  相似文献   

14.
Anaerobic pretreatment followed by aerobic posttreatment of municipal wastewater is being used more frequently. Recent investigations in this field using an anaerobic fluidized bed reactor/aerobic solids contact combination demonstrated the technical feasibility of this process. The investigation presented herein describes the use of a combined upflow anaerobic sludge bed (UASB)/aerobic solids contact system for the treatment of municipal wastewater and attempts to demonstrate the technical feasibility of using the UASB process as both a pretreatment unit and a waste activated sludge digestion system. The results indicate that the UASB reactor has a total chemical oxygen demand removal efficiency of 34%, and a total suspended solids removal efficiency of about 36%. Of the solids removed by the unit, 33% were degraded by the action of microorganisms, and 4.6% accumulated in the reactor. This low solids accumulation rate allowed operating the UASB reactor for three months without sludge wasting. The long solids retention time in this unit is comparable to the one normally used in conventional sludge digestion units, thus allowing the stabilization of the waste activated sludge returned to the UASB reactor. Particle flocculation was very poor in the UASB reactor, and therefore, it required postaeration periods of at least 100?min to proceed successfully in the aerobic unit. Polymer generation, which is necessary for efficient biological flocculation, was practically nonexistent in the anaerobic unit; therefore, it was necessary to maintain dissolved oxygen levels greater than 1.5?mg/L in the aerobic solids contact chamber for polymer generation to proceed at optimum levels. Once these conditions were attained, the quality of the settled solids contact chamber effluent always met the 30?mg BOD/L, 30?mg SS/L secondary effluent guidelines.  相似文献   

15.
A bench-scale study used nonwoven geotextiles as a compact biomass host media to treat wastewater from a combined sewer system. The geotextile coupons were used as baffles and suspended in an aerated reactor. Each baffle was offset in succession to form a sinuous channel with permeable boundaries. Filtering the total suspended solids (TSS) and micro-organisms formed a biomass floc in the interior of the baffles, which grew to emerge on the surface. Suspended and nonsettleable colloidal solids in the influent wastewater were captured by both filtration and adsorption from the channel flow. This bench-scale setup, named the geotextile baffle contact system, consistently provided secondary treatment to influent concentrations up to 318 mg/l of TSS and 114 mg/l of biological oxygen demand. Ammonia (NH3–N) concentrations were reduced over 90%, and mineralization of the nitrate (NO3–N) was also observed when the biofilm aged and thickened. Some of the influent TSS and sloughed biomass from the baffles settled to the bottom of the tank.  相似文献   

16.
In this study, oxidation-reduction potential (ORP) was employed to regulate oxygen dosing for online sulfide toxicity control during anaerobic treatment of high sulfate wastewater. The experiment was conducted in an upflow anaerobic filter, which was operated at a constant influent total organic carbon of 6,740 mg/L [equivalent to a chemical oxygen demand (COD) of 18,000 mg/L], but with different influent sulfates of 1,000, 3,000, and 6,000 mg/L. The reactor was initially run at natural ORP (the system’s ORP without oxygenation) of about ?290 to ?300?mV and then was followed by oxygenation to raise ORP by +25?mV above the natural level for each influent sulfate level. At 6,000 mg/L sulfate under the natural ORP, methanogenesis was severely inhibited due to sulfide toxicity, and the anaerobic process was almost totally upset. Upon oxygenation by raising ORP to ?265?mV, the dissolved sulfide was quickly reduced to 12.2 mg S/L with a concomitant improvement in methane yield by 45.9%. If oxygen was not totally used up by sulfide oxidation, the excess oxygen was consumed by facultative bacteria which had been found to stabilize about 13.5% of the influent COD. Both sulfide oxidation and facultative activity acted as a shield to protect the anaerobes from an excessive oxygen exposure. This study showed that direct oxygenation of the recirculated biogas was effective to oxidize sulfide, and the use of ORP to regulate the oxygen dosing was practical and reliable during anaerobic treatment of high sulfate wastewater.  相似文献   

17.
In ice-covered rivers, dissolved oxygen (DO) might fall below critical levels for aquatic biota in the absence of surface aeration, combined with low winter flow conditions and reduced photosynthesis rates. Open-water zones, however, can be created downstream of a diffuser by warm effluent discharges, resulting in an increase in surface aeration. In this study, we modeled the behavior of the effluent plume and the resulting open-water lead development in the Athabasca River, Alberta, Canada downstream of a pulp mill diffuser. The DO was found to increase by 0.26?mg/L due to surface aeration of an open-water lead of 6.07?km. We also evaluated oxygen injection into the effluent pipeline to increase the DO in the river. At an injection rate of 3,500 and 5,000?lb/day of liquid oxygen, the DO was increased by 0.16 and 0.21?mg/L, which corresponded to an absorption efficiency of about 50%. The artificial aeration technique evaluated here appears to be an effective alternative to increase DO levels in ice-covered rivers. The results of this study are important in developing accurate DO models for ice-covered rivers and in evaluating oxygen injection systems.  相似文献   

18.
This study investigates the potential of primary sludge fermentation for the generation of readily biodegradable substrate. Experimental evaluation indicates that uncontrolled fermentation converted 22% of the initial volatile suspended solids in the sludge into soluble biodegradable chemical oxygen demand (COD). More than 85% of the soluble COD generated was associated with the formation of short chain volatile fatty acids (VFAs). The recoverable fraction of the fermented sludge supernatant may potentially increase the biodegradable COD content of the primary effluent by 5%. The VFA composition predominantly involved acetic and propionic acids as reported in the literature. Due to the high VFA content, activated sludge Model No. 1 could not predict the COD fractionation in the primary sludge; activated sludge Model No. 3 provided a better interpretation of the oxygen uptake profile through initial storage of the VFAs in the sludge.  相似文献   

19.
采用SBR工艺处理稀土矿区低碳氨氮废水, 对活性污泥进行驯化培养并考察了曝气量、曝气时间及碳氮比对短程硝化系统的影响。试验结果表明:温度为(28±1) ℃、曝气量为65 L/h, pH值为8的条件下, 经过69 d的驯化培养后, 系统对氨氮的去除率达92%, 亚硝态氮积累率稳定在90%以上, 对短程硝化过程启动前后样品进行高通量测序, 结果表明:污泥中微生物种类减少, 多样性降低, 亚硝化单胞菌属成为优势种群, 占比达11.5%。提高曝气量至120 L/h并在此条件下运行7 d后, 亚硝态氮积累率下降至82%;维持C/N在3.5~7.6之间, 系统中NH4+-N的去除率均能稳定在95%左右, NO2--N积累率也均可达93%以上;过度曝气会破坏短程硝化系统, 过度曝气至第8天, 亚硝态氮的积累率降至48.89%。   相似文献   

20.
Cell immobilized lipase-producing bacteria on three different matrices were incorporated in a fat-, oil-, and grease (FOG) trap system for restaurant wastewater treatment. During a 16-day laboratory-scale experiment for the treatment of synthetic FOG wastewater containing soybean oil, no significant difference (two-tailed t test at 95% confidence interval) in the FOG removal between two systems was observed at FOG influent ≤ 1,000?mg/L. However, the typical trap showed lower FOG removal efficiency than the matrix-based system when the influent FOG concentration was increased to ≥ 5,000?mg/L. In addition, the matrix-based trap system was able to sustain a stable high FOG removal, with <100?mg/L effluent, even at 10,000 mg/L influent FOG. Based on FOG heights measured and mass balance calculations, 97.4 and 99.5% of the total FOG load for 16 days were removed in a typical trap and matrix-based system, respectively. About 93.6% of the removal in the matrix-based was accounted to biodegradation. The 30-day full-scale operations demonstrated a distinguishably better performance in the matrix-based system (92.7±9.06% of 1,044.8±537.27?mg FOG/L) than in the typical trap system (74.6±27.13% of 463.4±296.87?mg FOG/L) for the treatment of barbeque restaurant wastewater. Similarly, matrix-based system revealed higher chemical oxygen demand removal (85.9±11.99%) than the typical trap system (60.4±31.26%). Characterizations of the influent, emulsified, adsorbed and effluent FOG indicated that straight saturated fatty acids constituted the cause of clogging problems in the FOG-trap and piping system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号