首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The analysis of the stable nitrogen isotope compositions of individual amino acid stereoisomers through the use of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is presented. Nitrogen isotopic compositions of single amino acids or of their enantiomers is possible without the labor-intensive and time-consuming preparative-scale chromatographic procedures required for conventional stable isotope analysis. Following hydrolysis and derivatization, single-component isotope analysis is accomplished on nanomole quantities of each of the stereoisomers of an amino acid, utilizing the effluent stream of gas chromatographic separation. Nitrogen isotope fractionation is minimal during acylation of the amino acid, with no additional nitrogen being added stoichiometrically to the derivative. Thus, the isotopic composition of the nitrogen in the derivative is that of the original compound. Replicate stable nitrogen isotope analyses of 11 amino acids, and their trifluoroacetyl (TFA)/isopropyl (IP) ester derivatives, determined by both conventional isotope ratio mass spectrometry (IRMS) and GC/C/IRMS, indicate that the GC procedure is highly reproducible (standard deviations typically 0.3-0.4‰) and that isotopic differences between the amino acid and its TFA/IP derivative are, in general, less than 0.5‰.  相似文献   

2.
The use of highly enriched, uniformly labeled fatty acid ([U-13C]) with analysis by high-precision gas chromatography-combustion isotope ratio mass spectrometry (GCC-IRMS) has been evaluated as a metabolic tracer technique. 13C/12C ratios are routinely determined to precisions (SD) of less than 0.00001 (delta PDB less than 1/1000) for greater than 10 ng of fatty acid, and less than 0.001 (delta PDB less than 100/1000) for samples of 30 pg of fatty acid, the latter corresponding to a 100-fmol sample. Baseline fatty acid 13C/12C in human plasma fractions is shown to fluctuate not more than 0.000 04 (delta PDB 4/1000) over 10 h. 13C/12C enrichments greater than 0.001 (delta PDB 100/1000) are obtained in a fatty acid plasma fraction subsequent to a 10-mg dose of 42% 13C-labeled stearic acid to a 78-kg adult. Biokinetics are discerned over an 13C/12C enrichment range of less than 0.0002 (approximately 13/1000 in delta PDB units) in plasma. A means for correction of isotope ratio contamination due to carbon-containing derivatives is presented. High-precision GCC-IRMS used in concert with highly enriched tracers is shown to possess advantages versus organic GC/MS for stable isotopic tracer detection and is superior to radiotracer methods in terms of dose sizes and analysis efficiency.  相似文献   

3.
Rice AL  Quay PD 《Analytical chemistry》2006,78(18):6320-6326
Little is known about the isotopic composition of formaldehyde in the atmosphere, a chemical intermediate in hydrocarbon oxidation. Here, we present a promising new method to analyze the carbon (delta 13C) and hydrogen (delta D) isotopic composition of atmospheric formaldehyde. The direct isotopic analytical technique described uses continuous-flow gas chromatography-isotope ratio mass spectrometry, which provides flexibility for either isotopic analysis without correction for derivative functional groups. Current levels of precision of measurement are +/-1.1 and +/-50 per thousand (1 sigma) for delta 13C and delta D analyses, respectively. Concentration of formaldehyde in ambient air is also determined, coincident with isotopic measurement, to a precision of +/-15%. The method has the required sensitivity for analyses of formaldehyde in urban air on relatively small volume grab samples of whole air (10-70L STP), potentially providing high temporal resolution. This is particularly advantageous for studying formaldehyde given its short lifetime and large variability in the atmosphere.  相似文献   

4.
A new methodology for bromine stable isotope determination by continuous-flow isotope ratio mass spectrometry (CF-IRMS) was developed. The technique was tested on inorganic samples. Inorganic bromide was precipitated in the form of silver bromide by using silver nitrate in a standard methodology. Bromine stable isotope analysis was carried out on methyl bromide (CH3Br) after converting silver bromide to methyl bromide by reacting it with methyl iodide (CH3I). The system used in this study is an IsoPrime IRMS, with analytical capabilities of both dual-inlet and continuous-flow modes coupled with an Agilent 6890 GC equipped with a CTC Analytics CombiPAL autosampler. This new technique measures samples as small as 0.2 mg of AgBr (1 micromol of Br-). The bromine stable isotope analysis using continuous flow technology showed excellent precision and accuracy. The internal precision using pure methyl bromide gas is better than +/-0.03 per thousand (+/-SD); the external precision using seawater standard is better than +/-0.06 per thousand (+/-SD) for n = 12. Moreover, the sample analysis time is 16 min, as compared to 75 min needed in previous techniques. This allows for 50 samples to be analyzed in 1 day, as compared to 8 samples using the conventional techniques. A series of natural saline formation waters and brines from sedimentary and crystalline rock environments was measured by this new methodology to test the potential natural range of delta81Br. The bromine isotopic composition of the samples ranged from 0.00 to +1.80 per thousand relative to standard mean ocean bromide (SMOB). Initial trends and distinctive isotopic difference were noticed between crystalline shield brines and sedimentary formation brines.  相似文献   

5.
Liu R  Lv Y  Hou X  Yang L  Mester Z 《Analytical chemistry》2012,84(6):2769-2775
An accurate, simple, and sensitive method for the direct determination of proteins by nonspecies specific isotope dilution and external calibration high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) is described. The labeling of myoglobin (17 kDa), transferrin (77 kDa), and thyroglobulin (670 kDa) proteins was accomplished in a single-step reaction with a commercially available bis(2,2'-bipyridine)-4'-methyl-4-carboxybipyridine-ruthenium N-succinimidyl ester-bis(hexafluorophosphate) (Ru-NHS ester). Using excess amounts of Ru-NHS ester compared to the protein concentration at optimized labeling conditions, constant ratios for Ru to proteins were obtained. Bioconjugate solutions containing both labeled and unlabeled proteins as well as excess Ru-NHS ester reagent were injected onto a size exclusion HPLC column for separation and ICPMS detection without any further treatment. A (99)Ru enriched spike was used for nonspecies specific ID calibration. The accuracy of the method was confirmed at various concentration levels. An average recovery of 100% ± 3% (1 standard deviation (SD), n = 9) was obtained with a typical precision of better than 5% RSD at 100 μg mL(-1) for nonspecies specific ID. Detection limits (3SD) of 1.6, 3.2, and 7.0 fmol estimated from three procedure blanks were obtained for myoglobin, transferrin, and thyroglobulin, respectively. These detection limits are suitable for the direct determination of intact proteins at trace levels. For simplicity, external calibration was also tested. Good linear correlation coefficients, 0.9901, 0.9921, and 0.9980 for myoglobin, transferrin, and thyroglobulin, respectively, were obtained. The measured concentrations of proteins in a solution were in good agreement with their volumetrically prepared values. To the best of our knowledge, this is the first application of nonspecies specific ID for the accurate and direct determination of proteins using a Ru-NHS ester labeling reagent.  相似文献   

6.
The stability over time (repeatability) for the determination of site-specific 13C/12C ratios at natural abundance by quantitative 13C NMR spectroscopy has been tested on three probes: enriched bilabeled [1,2-13C2]ethanol; ethanol at natural abundance; and vanillin at natural abundance. It is shown in all three cases that the standard deviation for a series of measurements taken every 2-3 months over periods between 9 and 13 months is equal to or smaller than the standard deviation calculated from 5-10 replicate measurements made on a single sample. The precision which can be achieved using the present analytical 13C NMR protocol is higher than the prerequisite value of 1-2 per thousand for the determination of site-specific 13C/12C ratios at natural abundance (13C-SNIF-NMR). Hence, this technique permits the discrimination of very small variations in 13C/12C ratios between carbon positions, as found in biogenic natural products. This observed stability over time in 13C NMR spectroscopy indicates that further improvements in precision will depend primarily on improved signal-to-noise ratio.  相似文献   

7.
Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of (37)Cl/(35)Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ(37)Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1‰), to GC/qMS (1σ ≈ 0.2-0.5‰ for Agilent GC/qMS and 1σ ≈ 0.2-0.9‰ for Thermo GC/qMS). Nonetheless, δ(37)Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications.  相似文献   

8.
Conditions and systems for on-line combustion of effluents from capillary gas chromatographic columns and for removal of water vapor from product streams were tested. Organic carbon in gas chromatographic peaks 15 s wide and containing up to 30 nanomoles of carbon was quantitatively converted to CO2 by tubular combustion reactors, 200 x 0.5 mm, packed with CuO or NiO. No auxiliary source of O2 was required because oxygen was supplied by metal oxides. Spontaneous degradation of CuO limited the life of CuO reactors at T > 850 degrees C. Since NiO does not spontaneously degrade, its use might be favored, but Ni-bound carbon phases form and lead to inaccurate isotopic results at T < 1050 degrees C if gas-phase O2 is not added. For all compounds tested except CH4, equivalent isotopic results are provided by CuO at 850 degrees C, NiO + O2 (gas-phase mole fraction, 10(-3)) at 1050 degrees C and NiO at 1150 degrees C. The combustion interface did not contribute additional analytical uncertainty, thus observed standard deviations of 13C/12C ratios were within a factor of 2 of shot-noise limits. For combustion and isotopic analyses of CH4, in which quantitative combustion required T approximately 950 degrees C, NiO-based systems are preferred, and precision is approximately 2 times lower than that observed for other analytes. Water must be removed from the gas stream transmitted to the mass spectrometer or else protonation of CO2 will lead to inaccuracy in isotopic analyses. Although thresholds for this effect vary between mass spectrometers, differential permeation of H2O through Nafion tubing was effective in both cases tested, but the required length of the Nafion membrane was 4 times greater for the more sensitive mass spectrometer.  相似文献   

9.
A new, completely automated gas chromatography technique has been developed to separate the different gaseous compounds produced during underground coal gasification for their (13)C/(12)C and D/H isotope ratio measurements. The technique was designed for separation and collection of H(2), CO, CO(2), H(2)O, H(2)S, CH(4), and heavier hydrocarbons. These gaseous compounds are perfectly separated by the gas-phase chromatograph and quantitatively sent to seven combustion and collection lines. H(2), CO, CH(4), and heavier hydrocarbons are quantitatively oxidized to CO(2) and/or H(2)O. The isotopic analyses are performed by the sealed-tube method. The zinc method is used for reduction of both water and H(2)S to hydrogen for D/H analysis. Including all preparation steps, the reproducibility of isotope abundance values, for a quantity higher than or equal to 0.1 mL of individual components in a mixture (5 mL of gases being initially injected in the gas chromatograph), is ±0.1‰ for δ(13)C(PDB) and ±6‰ for δD(SMOW).  相似文献   

10.
Continuous-flow inlets from oxidation reactors are commonly used systems for biological sample introduction into isotope ratio mass spectrometers (IRMS) to measure 13C enrichment above natural abundance. Because the samples must be volatile enough to pass through a gas chromatograph, silylated derivatization reactions are commonly used to modify biological molecules to add the necessary volatility. Addition of a tert-butyldimethylsilyl (TBDMS) group is a common derivatization approach. However, we have found that samples do not produce the expected increment in measured 13C abundance as the TBDMS derivatives. We have made measurements of 13C enrichment of leucine and glutamate standards of known 13C enrichment using derivatives without silicon (N-acetyl n-propyl ester), with silicon (TBDMS), and an intermediate case. The measurements of 13C in amino acids derivatized without silicon were as expected. The 13C enrichment measurements using the TBDMS derivative were higher than expected but could be corrected to produce the expected 13C enrichment measurement by IRMS if one carbon was removed per silicon. We postulate that the silicon in the derivative forms silicon carbide compounds in the heated cupric oxide reactor, rather than forming silicon dioxide. Doing so reduces the amount of CO2 formed from the carbon in the sample. Silylated derivatives retain carbon with the silicon and must be used carefully and with correction factors to measure 13C enrichments by continuous-flow IRMS.  相似文献   

11.
Liao Z  Wan Y  Thomas SN  Yang AJ 《Analytical chemistry》2012,84(10):4535-4543
Accurate protein identification and quantitation are critical when interpreting the biological relevance of large-scale shotgun proteomics data sets. Although significant technical advances in peptide and protein identification have been made, accurate quantitation of high-throughput data sets remains a key challenge in mass spectrometry data analysis and is a labor intensive process for many proteomics laboratories. Here, we report a new SILAC-based proteomics quantitation software tool, named IsoQuant, which is used to process high mass accuracy mass spectrometry data. IsoQuant offers a convenient quantitation framework to calculate peptide/protein relative abundance ratios. At the same time, it also includes a visualization platform that permits users to validate the quality of SILAC peptide and protein ratios. The program is written in the C# programming language under the Microsoft .NET framework version 4.0 and has been tested to be compatible with both 32-bit and 64-bit Windows 7. It is freely available to noncommercial users at http://www.proteomeumb.org/MZw.html .  相似文献   

12.
The analysis of protein interactors in protein complexes can yield important insight into protein function and signal transduction. Thus, a reliable approach to distinguish true interactors from nonspecific interacting proteins is of utmost importance for accurate data interpretation. Although stringent purification methods are critical, challenges still remain in the selection of criteria that will permit the objective differentiation of true members of the protein complex from nonspecific background proteins. To address these challenges, we have developed a quantitative proteomic strategy combining stable isotope labeling with amino acids in cell culture (SILAC), affinity substrate trapping, and gel electrophoresis followed by liquid chromatography-tandem mass spectrometry (geLC-MS/MS) protein quantitation. ATP hydrolysis-deficient vacuolar protein sorting-associated protein 4B (Vps4B) was used as the "bait" protein which served as a substrate trap since its lack of ATP hydrolysis enzymatic activity allows the stabilization of its transiently associated interacting proteins. A significant advantage of our approach is the use of our new in-house-developed software program for SILAC-based mass spectrometry quantitation, which further facilitates the differentiation between the bait protein, endogenous bait-interacting proteins, and nonspecific binding proteins based on their protein ratios. The strategy presented herein is applicable to the analysis of other protein complexes whose compositions are dependent upon the ATP hydrolysis activity of the bait protein used in affinity purification studies.  相似文献   

13.
14.
15.
A new method for the quantification of benzoxazinone derivatives in extracts of wheat foliage and root samples using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) is described. Using this method, the characterization, separation, and quantitative detection of a mixture of six naturally occurring 1,4-benzoxazin-3(4H)-one derivatives, including the hydroxamic acids (DIMBOA, DIBOA), lactams (HBOA, and HMBOA), benzoxazilinones (BOA, MBOA), and two synthetic methoxylated variations of DIBOA and HBOA, was achieved. The application of a novel, highly modified reversed-phase LC column, the dodecyl (C12) TMS end-capped Synergi MAX-RP, enhanced the on-line chromatographic separation through improvements to component resolution, analyte stability and peak shape and also to the column lifetime. The complete ESI-MS-MS precursor-product ion fragmentation pathways for the benzoxazinone derivatives are described for the first time and used to deduce a generic fragmentation pattern for the compound class. Characteristic transitions for the benzoxazinones were thus used in the developed analytical method enabling reliable quantification with simultaneous screening for other potentially present derivatives, while eliminating interferences from other coeluting contaminants from the complex plant extract matrix. Quantitative analysis was done in the multiple reaction monitoring mode, using two specific combinations of a precursor-product ion transitions for each compound. The ESI-MS-MS detection method offered improvements to the sensitivity and selectivity, as compared with previously applied LC methods, with detection limits down to 0.002-0.023 ng/microL. The developed method was demonstrated by analyzing foliages and roots of six different wheat cultivars using pressurized liquid extraction-solid-phase extraction cleanup-LC-ESI-MS-MS. The analytes were detected in the range of 0.7-207 microg/g of dry weight.  相似文献   

16.
An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA.  相似文献   

17.
The H3 factor, K, is a parameter required in high-precision, mass spectrometric analyses of hydrogen isotopic abundances. When H2 is used as the sample gas, R* = R - Ki2, where R* is the true HD/H2 ratio, R is the observed (mass 3)/(mass 2) ion-current ratio, and i2 is the ion current at mass 2. Four different methods for the determination of K were defined and tested under conditions characteristic of isotope ratio monitoring systems. Three of these were peak-based. The fourth employed steady flows of H2 from a conventional inlet system. Results obtained using the latter method were more precise (standard deviation of K = 0.1 versus approximately 0.6 ppm mV(-1) for the peak-based methods). However, use of the resulting values of K for correction of isotope ratio monitoring GC/MS results led to systematic errors as large as 9 per thousand, whereas use of the peak-based values led to no systematic errors. Values of K were only weakly dependent on the pressure of He, declining approximately 5% for each 10-fold increase in P(He). Small variations in partial pressures of H2O and CH4, potential contaminants under isotope ratio monitoring conditions, had no significant effect on values of K.  相似文献   

18.
Tai SS  Welch MJ 《Analytical chemistry》2004,76(4):1008-1014
Cortisol is an important diagnostic marker for the production of steroid hormones, and accurate measurements of serum cortisol are necessary for proper diagnosis of adrenal function. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(3), was added to serum, followed by equilibration and solid-phase and ethyl acetate extractions to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) and liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analyses. (M + H)(+) ions at m/z 363 and 366 for cortisol and its labeled internal standard were monitored for LC/MS. The transitions of (M + H)(+) --> [(M + H)(+) - 2H(2)O] at m/z 363 --> 327 and 366 --> 330 were monitored for LC/MS/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for cortisol [Certified Reference Materials 192 and 193] with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added cortisol. The results of this method for total cortisol agreed with the certified values within 1.1%. The recovery of the added cortisol ranged from 99.8% to 101.0%. This method was applied to the determination of cortisol in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.3%-1.5% and between-set CVs of 0.04%-0.4% for both LC/MS and LC/MS/MS analyses. The correlation coefficients of all linear regression lines ranged from 0.998 to 1.000. The detection limits (at a signal-to-noise ratio of approximately 3-5) were 10 and 15 pg for LC/MS and LC/MS/MS, respectively. This method, which demonstrates good accuracy and precision, and is free from interferences from structural analogues, qualifies as a candidate reference method and can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared.  相似文献   

19.
We report the development of a method of carbon stable isotope ratio analysis based on 1-cm-1 resolution Fourier transform infrared (FT-IR) spectroscopy, deployable in both laboratory and field applications. We demonstrate the determination of the 13C/12C ratio of CO2 (i.e., delta 13CO2) in air with an analytical precision of the order of +/- 0.1/1000 (i.e., +/- 0.01%). The FT-IR method relies on calibration using synthetically calculated absorbance spectra and a multivariate calibration algorithm. The method requires no sample preparation other than optional drying of the sample and may be applied directly to ambient air samples containing approximately 350 mumol mol-1 CO2 (molar mixing ratio). It may also be applied to samples more concentrated in CO2, such as human breath, approximately 5% CO2. We demonstrate the utility of the technique to the analysis of delta 13CO2 in air during an experimental field campaign and to the laboratory-based analysis of human breath. A similar method could also be used to determine the H/D ratio in atmospheric water vapor.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏