首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A comparative analysis is presented of a novel plate‐type isothermal heat pump dryer and a conventional adiabatic heat pump dryer. The energy performance and drying capacity of each dryer type is investigated subject to operational constraints on the maximum acceptable relative humidity and temperature of air passing over the product. The analysis demonstrates that for applicable products, a significant opportunity exists for improving the energy efficiency of heat pump drying, by a factor of 2–3 times compared with current adiabatic heat pump dryers. The moisture extraction rate is also increased in the contact heat pump dryer, by a similar factor. However, these improvements are shown to be sensitive both to the impact of product thickness on heat transfer and to the relative humidity constraint. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
In this study, olive leaves were dried in a pilot‐scale heat pump (HP) belt conveyor dryer as a thin layer. Drying experiments were carried out at the drying air temperature range of 45–55°C with the drying air velocity range of 0.5–1.5 m s−1. The performance of the system and the process was evaluated using exergy analysis method. The exergy loss and flow diagram (the so‐called Grassmann diagram) of the dryer system was presented to give quantitative information regarding the proportion of the exergy input that is dissipated in the various system components. Effects of the drying air temperature and the velocity on the performance of the drying process were discussed. The actual coefficient of performance values were obtained to be 2.37 for the HP unit and 2.31 for the overall system, respectively. The most important component of the system for improving the efficiency was determined to be the compressor. Exergetic efficiencies of the drying of olive leaves were in the range of 67.45–81.95%. It was obtained that they increased as the drying air temperature decreased and the drying air velocity increased. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
The experimental and predicted performance data of a heat pump dryer system is reported. Chopped alfalfa was dried in a cabinet dryer in batches and also by emulating continuous bed drying using two heat pumps operating in parallel. Results showed that alfalfa was dried from an initial moisture content of 70% (wb) to a final moisture content of 10% (wb). The batch drying took about 4.5 h while continuous bed drying took 4 h to dry the same amount of material. The average air velocity inside the dryer was 0.36 m s?1. Low temperatures (30–45°C) for safe drying of specialty crops were achieved experimentally. The heat pump drying system used in this study was about 50% more efficient in recovering the latent heat from the dryer exhaust compared to the conventional dryers. Specific moisture extraction rate (SMER) was maximum when relative humidity stayed above 40%. The dryer was shown to be capable of SMER of between 0.5 and 1.02 kg kW?1 h?1. It was concluded that continuous bed drying is potentially a better option than batch drying because high process air humidity ratios at the entrance of the evaporator and constant moisture extraction rate and specific moisture extraction rate values can be maintained. An uncertainty analysis confirmed the accuracy of the model. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

4.
This research is concerned with the technology of heat pump assisted drying of specialty crops. A simplified procedure for modelling the performance of a low temperature heat pump dryer was developed. The system modelled consists of a vapour compression heat pump coupled to a continuous cross flow bed dryer. The model takes into account the detailed heat and mass transfer phenomena taking place in the heat pump and dryer circuits. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

5.
6.
Thermal performance parameters for a solar-assisted heat pump (SAHP) drying system with underground thermal energy storage (TES) tank and heat recovery unit (HRU) are investigated in this study. The SAHP drying system is made up of a drying unit, a heat pump, flat plate solar collectors, an underground TES tank, and HRU. An analytical model is developed to obtain the performance parameters of the drying system by using the solution of heat transfer problem around the TES tank and energy expressions for other components of the drying system. These parameters are coefficient of performances for the heat pump (COP) and system (COPs), specific moisture evaporation rate (SMER), temperature of water in the TES tank, and energy fractions for energy charging and extraction from the system. A MATLAB program has been prepared using the expressions for the drying system. The obtained results for COP, COPs, and SMER are 5.55, 5.28, and 9.25, respectively, by using wheat mass flow rate of 100 kg h−1, Carnot efficiency of 40%, collector area of 100 m2, and TES tank volume of 300 m3 when the system attains periodic operation duration in fifth year onwards for 10 years of operation. Annual energy saving is 21.4% in comparison with the same system without using HRU for the same input data.  相似文献   

7.
叙述了城市污泥干燥处理的必要性,对采用热泵形式进行干燥进行了理论分析,并对理论分析进行了实验验证。  相似文献   

8.
建立耦合双级热泵制热系统,即设定空气源热泵作为一级预热机组,水源热泵机组作为二级制热机组,从而实现双级耦合制热。实验对空气源热泵在各种实际工况下运行的COP值进行测量与分析,当环境温度在-5℃时,若循环制热温度20℃左右.其COP值仍能够达到4;水-风式水源热泵机组在15~20℃水源循环进水温度时,能耗比(COP)值平均超过4;同时,实验还在对建型的耦合双级热泵装置进行实际测量的基础上.得出客观结论.即使在寒冷的气候条件下,双级热泵仍能够保持较高的节能效果和使用效果。  相似文献   

9.
热泵干燥系统运行特性的有效能研究   总被引:11,自引:0,他引:11  
热泵干燥能源消耗少,环境污染小,干燥品质高,适用范围广,是一种性能优良的种子干燥机械。从热力学第一、第二定律两方面分析了热泵干燥系统的节能优势所在,得出采用辅助冷凝器是闭式热泵干燥系统的理想方式;而且热泵干燥系统存在一个最佳的蒸发温度,可使系统除湿率和效率最大。  相似文献   

10.
节能环保型热泵干燥装置   总被引:8,自引:1,他引:8  
介绍一种具有回热循环的闭路式热泵干燥装置,其除效率高,能量利用率高,且封闭循环,是较理想的节能,环保型干燥装置。  相似文献   

11.
A solar assisted heat pump dryer has been designed, fabricated and tested. This paper presents the performance of the evaporator-collector and the air collector when operated under the same meteorological conditions. ASHRAE standard procedure for collector testing has been followed. The evaporator-collector of the heat pump is acting directly as the solar collector, and the temperature of the refrigerant at the inlet to the evaporator-collector always remained below the ambient temperature. Because of the rejection of sensible and latent heats of air at the dehumidifier, the temperature at the inlet to the air collector is lower than that of the ambient air. Hence, the thermal efficiency of the air collector also increases due to a reduction of losses from the collector. The efficiencies of the evaporator-collector and the air collector were found to vary between 0.8–0.86 and 0.7–0.75, respectively, when operated under the meteorological conditions of Singapore.  相似文献   

12.
In this study heat pump systems having different heat sources were investigated experimentally. Solar‐assisted heat pump (SAHP), ground source heat pump (GSHP) and air source heat pump (ASHP) systems for domestic heating were tested. Additionally, their combination systems, such as solar‐assisted‐ground source heat pump (SAGSHP), solar‐assisted‐air source heat pump (SAASHP) and ground–air source heat pump (GSASHP) were tested. All the heat pump systems were designed and constructed in a test room with 60 m2 floor area in Firat University, Elazig (38.41°N, 39.14°E), Turkey. In evaluating the efficiency of heat pump systems, the most commonly used measure is the energy or the first law efficiency, which is modified to a coefficient of performance for heat pump systems. However, for indicating the possibilities for thermodynamic improvement, inadequate energy analysis and exergy analysis are needed. This study presents an exergetic evaluation of SAHP, GSHP and ASHP and their combination systems. The exergy losses in each of the components of the heat pump systems are determined for average values of experimentally measured parameters. Exergy efficiency in each of the components of the heat pump systems is also determined to assess their performances. The coefficient of performance (COP) of the SAHP, GSHP and ASHP were obtained as 2.95, 2.44 and 2.33, whereas the exergy losses of the refrigerant subsystems were found to be 1.342, 1.705 and 1.942 kW, respectively. The COP of SAGSHP, SAASHP and GSASHP as multiple source heat pump systems were also determined to be 3.36, 2.90 and 2.14, whereas the exergy losses of the refrigerant subsystems were approximately 2.13, 2.996 and 3.113 kW, respectively. In addition, multiple source heat pump systems were compared with single source heat pump systems on the basis of the COP. Exergetic performance coefficient (EPC) is introduced and is applied to the heat pump systems having various heat sources. The results imply that the functional forms of the EPC and first law efficiency are different. Results show that Exloss,total becomes a minimum value when EPC has a maximum value. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
A numerical simulation model is developed to predict the forced convection performance of a dryer. This model takes into account the shrinkage phenomenon of the products during the drying process. The experimental results of the potato drying are obtained in climatic conditions similar to conditions found in natural open‐air drying when the dryer is fed by air heated by a solar air flat plate collector. After a study of the influence of parameters of the drying air on the product during the drying process, we expose the experimental results and compare them with those calculated by the theoretical model. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

14.
Ground source heat pump systems are becoming more and more popular, even though their high initial cost is an obstacle to their wider penetration of the heating and cooling market. The purchase of the heat pump itself is one of the dominant costs, and the heat pump selection also influences the operation costs through its coefficient of performance (COP) value. However, few studies are available on this topic. Based on 23 water–water heat pump models available on the market, a correlation was developed to estimate their purchase cost as a function of the nominal cooling load of the heat pump. These heat pumps can be used in geothermal applications as well as in other heating, ventilating, air conditioning and refrigeration (HVAC&R) systems. The correlation is valid for a nominal cooling load between 20 and 841 kW. The nominal COP of the heat pumps was found to have virtually no effect on their purchase costs. Also, two correlations were developed to relate variations of cooling power and COP to the temperature levels on both sides of the heat pump. The heating mode is also considered. The correlations are useful to estimate the required nominal size of a heat pump given design operating conditions and to optimize ground source heat pump systems from a techno‐economical standpoint. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
This paper presents a consideration of micro‐heat exchangers design optimization for the aim of process intensification. Two examples are discussed to illustrate different ways of heat transfer intensification in micro‐heat exchangers. To solve the key issue of the link between the micro‐scale and the macro‐scale, a multi‐scale design optimization method using fractal and constructal approaches is introduced. The concept of a novel constructal heat exchanger is also proposed. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

16.
参数变化对LiBr吸收式热泵性能的影响   总被引:1,自引:0,他引:1  
针对溴化锂吸收式热泵的特点,在一定参数变化范围内研究驱动热源、冷媒水以及冷却水进出口变化对其性能的影响。结果表明,不同参数对COP及具体设备的热负荷、传热温差造成不同程度的影响,在热泵的设计过程中应综合考虑各参数的取值以获得最佳的效果。研究结果为热泵系统的优化设计提供理论支持和参考。  相似文献   

17.
地表水源热泵系统的设计   总被引:11,自引:0,他引:11  
介绍了地表水源热泵系统的2种形式及其特点;研究了湖水传热的方式,并给出了湖水换热器的设计方法,包括循环介质流量、换热器类型、换热器的长度、换热器管径的确定。  相似文献   

18.
This paper presents experimental and simulated performance of a PV-ventilated solar greenhouse dryer for drying of peeled longan and banana. The dryer consists of a parabolic roof structure covered with polycarbonate plates on a concrete floor. Three fans powered by a 50-W PV module ventilate the dryer. To investigate the experimental performances of the solar greenhouse dryer for drying of peeled longan and banana, 10 full scale experimental runs were conducted. Of which five experimental runs were conducted for drying of peeled longan and another five experimental runs were conducted for drying of banana. The drying air temperature varied from 31 °C to 58 °C during drying of peeled longan while it varied from 30 °C to 60 °C during drying of banana. The drying time of peeled longan in the solar greenhouse dryer was 3 days, whereas 5-6 days are required for natural sun drying under similar conditions. The drying time of banana in the solar greenhouse dryer was 4 days, while it took 5-6 days for natural sun drying under similar conditions. The quality of solar dried products in terms of colour and taste was high-quality dried products. A system of partial differential equations describing heat and moisture transfer during drying of peeled longan and banana in the solar greenhouse dryer was developed and this system of non-linear partial differential equations was solved numerically using the finite difference method. The numerical solution was programmed in Compaq Visual FORTRAN version 6.5. The simulated results reasonably agreed with the experimental data for solar drying of peeled longan and banana. This model can be used to provide the design data and is also essential for optimal design of the dryer.  相似文献   

19.
In evaluating the efficiency of heat pump (HP) systems, the most commonly used measure is the energy (or first law) efficiency, which is modified to a coefficient of performance (COP) for HP systems. However, for indicating the possibilities for thermodynamic improvement, energy analysis is inadequate and exergy analysis is needed. This study presents an exergetic assessment of a ground‐source (or geothermal) HP (GSHP) drying system. This system was designed, constructed and tested in the Solar Energy Institute of Ege University, Izmir, Turkey. The exergy destructions in each of the components of the overall system are determined for average values of experimentally measured parameters. Exergy efficiencies of the system components are determined to assess their performances and to elucidate potentials for improvement. COP values for the GSHP unit and overall GSHP drying system are found to range between 1.63–2.88 and 1.45–2.65, respectively, while corresponding exergy efficiency values on a product/fuel basis are found to be 21.1 and 15.5% at a dead state temperature of 27°C, respectively. Specific moisture extraction rate (SMER) on the system basis is obtained to be 0.122 kg kW?1 h?1. For drying systems, the so‐called specific moisture exergetic rate (SMExR), which is defined as the ratio of the moisture removed in kg to the exergy input in kW h, is also proposed by the authors. The SMExR of the whole GSHP drying system is found to be 5.11 kg kW?1 h?1. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

20.
The multi‐stage fluidized bed can be used to preheat the combustion air by recovering the waste heat from the exhaust gas from industrial furnaces. The dilute‐phase fluidized bed may be formed to exclude the excessive pressure drop across the multi‐stage fluidized bed. But, in this case, the solid particles do not reach to the thermal equilibrium due to relatively short residence time in each layer of fluidized bed. In this study, a theoretical analysis on the dilute phase multistage fluidized bed heat exchanger was performed. A parameter related to the degree of thermal equilibrium between gas and solid particles at the dilute‐phase fluidized beds was derived. Using this parameter, a relatively simple expression was obtained for the thermal efficiencies of the multi‐stage fluidized bed heat exchanger and air preheater. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号