首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Three ways to approximate a proximity relation $R$ (i.e., a reflexive and symmetric fuzzy relation) by a $T$ -transitive one where $T$ is a continuous Archimedean $t$-norm are given. The first one aggregates the transitive closure $overline{R}$ of $R$ with a (maximal) $T$-transitive relation $B$ contained in $R$ . The second one computes the closest homotecy of $overline{R}$ or $B$ to better fit their entries with the ones of $R$. The third method uses nonlinear programming techniques to obtain the best approximation with respect to the Euclidean distance for $T$ the $Lstrok$ukasiewicz or the product $t$-norm. The previous methods do not apply for the minimum $t$-norm. An algorithm to approximate a given proximity relation by a ${rm Min}$-transitive relation (a similarity) is given in the last section of the paper.   相似文献   

2.
Motivated by questions in robust control and switched linear dynamical systems, we consider the problem checking whether all convex combinations of $k$ matrices in $R^{n times n}$ are stable. In particular, we are interested whether there exist algorithms which can solve this problem in time polynomial in $n$ and $k$. We show that if $k= lceil n^{d} rceil $ for any fixed real $d>0$, then the problem is NP-hard, meaning that no polynomial-time algorithm in $n$ exists provided that $P ne NP$, a widely believed conjecture in computer science. On the other hand, when $k$ is a constant independent of $n$ , then it is known that the problem may be solved in polynomial time in $n$. Using these results and the method of measurable switching rules, we prove our main statement: verifying the absolute asymptotic stability of a continuous-time switched linear system with more than $n^{d}$ matrices $A_{i} in R^{n times n}$ satisfying $0 succeq A_{i} + A_{i}^{T}$ is NP-hard.   相似文献   

3.
A micromachining process has been developed to create high aspect ratio coplanar waveguides (HARCs). The process creates tall Si mesas using deep reactive-ion etching and converts them into solid $hbox{SiO}_{2}$ mesas using thermal oxidation. Tall Au conductors are deposited using electroplating and planarized using lapping and chemical-mechanical planarization. The solid $hbox{SiO}_{2}$ mesas form the dielectric gap between the tall Au conductors, resulting in HARCs with a planar surface. The tall conductor sidewalls created from the high aspect ratio process reduce the transmission line resistance, which allows the lines to have lower loss at low impedances compared to conventional transmission lines. Transmission lines with characteristic impedances of 16–21 $Omega$ have been fabricated on high-resistivity Si. Transmission line characteristics were measured from 1 to 50 GHz and showed an attenuation of 1.0–1.4 dB/cm at 10 GHz. Measurements were compared to HFSS simulations and showed reasonable agreement over the frequency range. $hfill$[2009-0132]   相似文献   

4.
We investigate the $ {cal L}_{2}$ gain of periodic linear switched systems under fast switching. For systems that possess a suitable notion of a time-average system, we characterize the relationship between the ${cal L}_{2}$ gain of the switched system and the ${cal L}_{2}$ gain of its induced time-average system when the switching rate is sufficiently fast. We show that the switched system ${cal L}_{2}$ gain is in general different from the average system ${cal L}_{2}$ gain if the input or output coefficient matrix switches. If only the state coefficient matrix switches, the input-output energy gain for a fixed ${cal L}_{2}$ input signal is bounded by the ${cal L}_{2}$ gain of the average system as the switching rate grows large. Additionally, for a fixed ${cal L}_{2}$ input, the maximum pointwise in time difference between the switched and average system outputs approaches zero as the switching rate grows.   相似文献   

5.
This paper presents the design, fabrication, and characterization of a new serial digital actuator, achieving an improvement in range-to-precision and range-to-voltage performance. We propose a weight-balanced design for the serial actuators with serpentine springs with a serial arrangement of unit digital actuators. We have measured the displacement range, precision, and drive voltage of unit and serial actuation at 1 Hz. The serial digital actuators produce a full-range displacement of $28.44 pm 0.02 muhbox{m}$ , accumulating unit displacements of $2.8 pm 0.5 muhbox{m}$ at an operating voltage of 4.47 $pm$ 0.07 V. In addition, the serial digital actuators that have a displacement precision of 37.94 $pm$ 6.26 nm do not accumulate the displacement errors of the unit actuators, i.e., 36.0 $pm$ 17.7 nm. We experimentally verify that the serial digital actuators achieve a range-to-squared-voltage ratio of 1.423 $muhbox{m/V}^{2}$ and a range-to-precision ratio of 749.6.$hfill$ [2009-0020]   相似文献   

6.
Analytical Model of Valveless Micropumps   总被引:2,自引:0,他引:2  
The flow driven by a valveless micropump with a single cylindrical pump chamber and two diffuser/nozzle elements is studied theoretically using a 1-D model. The pump cavity is driven at an angular frequency $omega$ so that its volume oscillates with an amplitude $V_{rm m}$. The presence of diffuser/nozzle elements with pressure-drop coefficients $zeta_{+}$, $zeta_{-}( ≫ zeta_{+})$ and throat cross-sectional area $A_{1}$ creates a rectified mean flow. In the absence of frictional forces the maximum mean volume flux (with zero pressure head) is $Q_{0}$ where $Q_{0}/V_{rm m}omega = (zeta_{-} -break zeta_{+})pi/16(zeta_{-}+zeta_{+})$, while the maximum pressure that can be overcome is $Delta P_{max}$ where $ Delta P_{max}A_{1}^{2}/V_{rm m}^{2} omega^{2} !=! (zeta_{-} -break zeta_{+})/16$. These analytical results agree with numerical calculations for the coupled system of equations and compare well with the experimental results of Stemme and Stemme.$hfill$ [2008-0244]   相似文献   

7.
This paper describes a decentralized $H_{infty }$ filter design for discrete-time interconnected fuzzy systems based on piecewise-quadratic Lyapunov functions. The systems consist of $J$discrete-time interconnected Takagi–Sugeno (T–S) fuzzy subsystems, and a decentralized $H_infty$ filter is designed for each subsystem. It is shown that the stability of the overall filtering-error system with $H_{infty }$ performance can be established if a piecewise-quadratic Lyapunov function can be constructed. Moreover, the parameters of filters can be obtained by solving a set of linear matrix inequalities that are numerically feasible. Two simulation examples are given to show the effectiveness of the proposed approach.   相似文献   

8.
This paper describes the development of aluminum nitride (AlN) resonant accelerometers that can be integrated directly over foundry CMOS circuitry. Acceleration is measured by a change in resonant frequency of AlN double-ended tuning-fork (DETF) resonators. The DETF resonators and an attached proof mass are composed of a 1- $muhbox{m}$ -thick piezoelectric AlN layer. Utilizing piezoelectric coupling for the resonator drive and sense, DETFs at 890 kHz have been realized with quality factors $(Q)$ of 5090 and a maximum power handling of 1 $muhbox{W}$. The linear drive of the piezoelectric coupling reduces upconversion of $1/f$ amplifier noise into $1/f^{3}$ phase noise close to the oscillator carrier. This results in lower oscillator phase noise, $-$96 dBc/Hz at 100-Hz offset from the carrier, and improved sensor resolution when the DETF resonators are oscillated by the readout electronics. Attached to a 110-ng proof mass, the accelerometer microsystem has a measured sensitivity of 3.4 Hz/G and a resolution of 0.9 $hbox{mG}/surdhbox{Hz}$ from 10 to 200 Hz, where the accelerometer bandwidth is limited by the measurement setup. Theoretical calculations predict an upper limit on the accelerometer bandwidth of 1.4 kHz.$hfill$ [2008-0190]   相似文献   

9.
In this paper, we use Zadeh's extension principle to extend Kosko's definition of the fuzzy subsethood measure $S(G,H)$ to type-2 fuzzy sets defined on any set $X$ equipped with a measure. Subsethood is itself a fuzzy set that is a crisp interval when $G$ and $H$ are interval type-2 sets. We show how to compute this interval and then use the result to compute subsethood for general type-2 fuzzy sets. A definition of subsethood for arbitrary fuzzy sets of type- $n ≫ 2$ is then developed. This subsethood is a type-( $n-1$) fuzzy set, and we provide a procedure to compute subsethood of interval type-3 fuzzy sets.   相似文献   

10.
An 8-pixel micromachined quartz crystal resonator array with a fundamental resonance frequency of 66 MHz has been designed, fabricated, and tested. A compact impedance-spectrum-analyzer electronic interface has been developed and combined with the quartz resonator array to form the biosensing system. The sensor array was calibrated using water–glycerol solutions, and the performance was found to be exactly as expected. Measurement of the crosstalk between the sensor pixels showed an isolation of $sim$ 30 dB. Selective functionalization of the pixels was achieved through the use of aqueous 3, 3 $^{prime}$-Dithiobis (sulfosuccinimidylpropionate) (DTSSP) molecules. The adsorption of avidin on DTSSP gave a frequency signal of 60 kHz in comparison to unfunctionalized pixels. The specific adsorption of avidin on functionalized pixels was confirmed through fluorescence microscopy. Comparing the performance of the micromachined quartz crystal microbalance (QCM) with a commercial 5-MHz device, we found that the micromachined QCM has a 4.25 times higher signal-to-noise ratio. Based on the measurement of the noise and using three times the frequency noise as the limit for the detection of avidin molecules, we expect to resolve a minimum of $sim$1/960 of a monolayer of avidin corresponding to an aerial mass density resolution of 0.7 $hbox{ng/cm}^{2}$ .$hfill$[2008-0196]   相似文献   

11.
Liquid-metal (LM) droplet-based MEMS switches have mostly been restricted to slow applications until now due to the following reasons: 1) a relatively large switching gap (distance) needed to accommodate imprecise volumes and locations of droplets on the device and 2) lack of high-speed actuation to move the droplets quickly across the switching gap. To combat these problems, we explore switching by sliding the solid–LM–gas triple contact line rather than the entire droplet. This new approach allows us to use a microframe, which not only consistently positions the LM droplet but also makes the switching gap less sensitive to the errors in the deposited-droplet volume, allowing us to design microswitches with very small switching gaps (e.g., 10 $muhbox{m}$ for 600 $muhbox{m}$-diameter droplets). Furthermore, a study of electrowetting-on-dielectric identifies a regime of fast contact-line sliding at the onset of droplet spreading. By moving the contact line fast across a small switching distance, we demonstrate a low-latency LM switch with 60 $muhbox{s}$ switch-on latency ( $sim$20 times better than other LM-switch technologies) and better than 5 $muhbox{s}$ signal rise/fall time, while boasting no contact bounce, as expected from an LM switch. High power-handling capability and long-term reliability are also discussed. $hfill$[2008-0135]   相似文献   

12.
Two versions of microdischarge-based pressure sensors, which operate by measuring the change, with pressure, in the spatial current distribution of pulsed dc microdischarges, are reported. The inherently high temperatures of the ions and electrons in the microdischarges make these devices amenable to high-temperature operation. The first sensor type uses 3-D arrays of horizontal bulk metal electrodes embedded in quartz substrates with electrode diameters of 1–2 mm and 50–100-$muhbox{m}$ interelectrode spacing. These devices were operated in nitrogen over a range of 10–2000 torr, at temperatures as high as 1000 $^{circ}hbox{C}$. The maximum measured sensitivity was 5420 ppm/torr at the low end of the dynamic range and 500 ppm/torr at the high end, while the temperature coefficient of sensitivity ranged from $-$925 to $-$550 ppm/K. Sensors of the second type use planar electrodes and have active areas as small as 0.13 $hbox{mm}^{2}$. These devices, when tested in a chemical sensing system flowing helium as a carrier gas, had a maximum sensitivity of 9800 ppm/torr, a dynamic range of 25–200 torr, and a temperature coefficient of sensitivity of approximately $-$1412 ppm/K.$hfill$ [2008-0262]   相似文献   

13.
Inchworm microactuators are popular in micropositioning applications for their long ranges. However, until now, they could not be considered for applications such as in vivo biomedical applications because of their high input voltages. This paper reports on the modeling, design, fabrication, and testing of a new family of pull-in-based electrostatic inchworm microactuators which provides a solution to this problem. Actuators with only 7-V operating voltage are achieved with a $pm 18hbox{-}muhbox{m}$ total range and a $pm 30hbox{-}muhbox{N}$ output force. Larger operating voltage (16 V) actuators show even better results in force ($pm 110 mu hbox{N}$) and range $(pm 35 muhbox{m})$. The actuator has an in-plane angular deflection conversion which provides a force-displacement tradeoff and allows us to set step sizes varying from few nanometers to few micrometers with a minor change in design. In this paper, we designed 1- and 4-$muhbox{m}$ step-size devices. The actuator step size may change during the operation because of the slipping of the shuttle and the beam bending; however, our model successfully explains the reasons. One of our actuator prototypes has survived more than 25 million cycles without performance deterioration. The device is fabricated using the silicon-on-insulator-based multiuser MEMS process.$hfill$[2007-0146]   相似文献   

14.
A 30-mm-long multimode waveguide, 40 $muhbox{m}$ wide and 40 $muhbox{m}$ high, is fabricated on a silicon wafer using polymer SU-8 as the core and liquid buffer as the cladding. Antibodies are successfully immobilized on the SU-8 surface designated for binding target antigens dispersed in the buffer solution. Evanescent-wave spectroscopy is performed by exciting the fluorescently labeled antigens, bound to the waveguide surface within its evanescence field, and measuring the emission light intensity. This evanescent-wave biosensor detects specific molecular interaction. The optical output as a function of the antigen concentration can be described by Langmuir equation. Antigen concentration as low as 1.5 $muhbox{g}/hbox{mL}$ is detected; concentrations higher than 100 $muhbox{g}/hbox{mL}$ lead to sensor saturation. $hfill$[2008-0058]   相似文献   

15.
We present a new temperature compensation system for microresonator-based frequency references. It consists of a phase-locked loop (PLL) whose inputs are derived from two microresonators with different temperature coefficients of frequency. The resonators are suspended within an encapsulated cavity and are heated to a constant temperature by the PLL controller, thereby achieving active temperature compensation. We show repeated real-time measurements of three 1.2-MHz prototypes that achieve a frequency stability of $pm$ 1 ppm from $-20 ^{circ}hbox{C}$ to $+80 ^{circ}hbox{C}$, as well as a technique to reduce steady-state frequency errors to $pm$0.05 ppm using multipoint calibration.$hfill$[2009-0074]   相似文献   

16.
A measurement of head-related transfer functions (HRTFs) with high spatial resolution was carried out in this study. HRTF measurement is difficult in the proximal region because of the lack of an appropriate acoustic point source. In this paper, a modified spark gap was used as the acoustic sound source. Our evaluation experiments showed that the spark gap was more like an acoustic point source than others previously used from the viewpoints of frequency response, directivity, power attenuation, and stability. Using this spark gap, high spatial resolution HRTFs were measured at 6344 spatial points, with distances from 20 to 160 cm, elevations from $-$40$^circ$ to 90 $^circ$, and azimuths from 0$^circ$ to 360$^circ$. Based on these measurements, an HRTF database was obtained and its reliability was confirmed by both objective and subjective evaluations.   相似文献   

17.
We present a new two-axis spiral-shaped micromirror manipulator developed for free-space optical switching. The actuator is an electrostatic actuator, which is composed of two different parts that are fabricated using conventional surface-micromachining processes and are then assembled. Instead of conventional monolithic self-assembling design approaches, these two parts are fabricated on two different chips and assembled using a spatial–mechanical approach. The design utilizes the increased flexibility of the spiral-shaped electrode and the zipping-effect technique in order to increase the maximum rotation angle. The footprint of the assembled device is $600 muhbox{m} times 600 muhbox{m}$, and the height of the micropyramid is 200 $muhbox{m}$. The switch is simulated using an energy method and a coupled electromechanical model. Its performance is measured statically using a reflection measurement approach. A continuous rotational actuation of 17$^{ circ}$ has been achieved with an actuation voltage of 235 V.$ hfill$[2008-0319]   相似文献   

18.
This paper describes the design, microfabrication, and testing of a novel polycrystalline-diamond (poly-C)-based microprobe for possible applications in neural prosthesis. The probe utilizes undoped poly-C with a resistivity on the order of $10^{5} Omegacdothbox{cm}$ as a supporting material, which has a Young's modulus in the range of 400–1000 GPa and is biocompatible. Boron-doped poly-C with a resistivity on the order of $10^{-3} Omegacdot hbox{cm}$ is used as an electrode material, which provides a chemically stable surface for both chemical and electrical detections in neural studies. The probe has eight poly-C electrode sites with diameters ranging from 2 to 150 $muhbox{m}$; the electrode capacitance is approximately 87 $muhbox{F/cm}^{2}$. The measured water potential window of the poly-C electrode spans across negative and positive electrode potentials and typically has a total value of 2.2 V in 1 M KCl. The smallest detectable concentration of norepinephrine (a neurotransmitter) was on the order of 10 nM. The poly-C probe has also been successfully implanted in the auditory cortex area of a guinea pig brain for in vivo neural studies. The recorded signal amplitude was 30–40 $muhbox{V}$ and had a duration of 1 ms. $hfill$[2008-0195]   相似文献   

19.
This paper presents a contactless droplet manipulation system that relies on thermally generated Marangoni flows. Programmable 2-D control of aqueous microdroplets suspended in an oil film on a plain featureless glass substrate is achieved using a 128-pixel heater array suspended 100–500 $mu hbox{m}$ above the oil layer. The heaters generate surface temperature perturbations $(≪ 25 ^{circ}hbox{C})$, resulting in local Marangoni flows that can move droplets in either a push or a pull mode. Programmed movement is achieved by the sequential activation of the heaters, with digital control circuitry and a graphical interface providing addressable control of each heater. Droplets with diameters of 300–1000 $muhbox{m}$ are manipulated and merged at speeds up to 140 $muhbox{m/s}$. Evaporation rates can be reduced by almost two orders of magnitude by using a two-layer-oil medium, and the choice of an optimum carrier fluid can achieve fluid velocities over 17 000 $mu hbox{m/s}$. The system provides a contactless platform for parallel droplet-based assays. As such, it circumvents the challenges of sample contamination and loss that occur when a droplet interacts with a solid surface.$hfill$[2008-0272]   相似文献   

20.
N-channel 6H-SiC depletion-mode junction field-effect transistors (JFETs) have been fabricated, and characterized for use in high-temperature differential sensing. Electrical characteristics of the JFETs have been measured and are in good agreement with predictions of an abrupt-junction long-channel JFET model. The electrical characteristics were measured across a 2-in wafer for temperatures from 25 $^{ circ}hbox{C}$ to 450 $^{circ}hbox{C}$, and the extracted pinchoff voltage has a mean of 11.3 V and a standard deviation of about 1.0 V at room temperature, whereas pinchoff current has a mean of 0.41 mA with standard deviation of about 0.1 mA. The change in pinchoff voltage is minimal across the measured temperature range, whereas pinchoff current at 450 $^{circ}hbox{C}$ is about half its value at room temperature, consistent with the expected change in the $nmu_{n}$ product. The characterization of differential pairs and hybrid amplifiers constructed using these differential pairs is also reported. A three-stage amplifier with passive loads has a differential voltage gain of 50 dB, and a unity-gain frequency of 200 kHz at 450 $^{circ}hbox{C}$, limited by test parasitics. A two-stage amplifier with active loads has reduced sensitivity to off-chip parasitics and exhibits a differential voltage gain of 69 dB with a unity-gain frequency of 1.3 MHz at 450 $^{circ}hbox{C}$.$hfill$[2009-0029]   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号