首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the local anesthetic-sparing efficacy of epidural sufentanil by its effect on the MLAC of bupivacaine. METHODS: In this double-blind, randomized, prospective study, 147 parturients at < or = 7 cm cervical dilation who requested epidural analgesia were allocated to one of four study groups. After a lumbar epidural catheter was placed, study participants received 20 ml bupivacaine (n = 38), bupivacaine with sufentanil 0.5 microg/ml (n = 38), bupivacaine with sufentanil 1 microg/ml (n = 33), or bupivacaine with sufentanil 1.5 microg/ml (n = 38). The concentration of bupivacaine was determined by the response of the previous patient using up-down sequential allocation. The analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min defined as effective. RESULTS: The MLAC of bupivacaine alone was 0.104% wt/vol (95% CI, 0.090-0.117). The addition of sufentanil at doses of 0.5 microg/ml, 1 microg/ml, and 1.5 microg/ml resulted in significant reductions (P < 0.0001) in the MLAC of bupivacaine to 0.048% wt/vol (95% CI, 0.030- 0.065), 0.021% wt/vol (95% CI, 0-0.055), and 0.009% wt/vol (95% CI, 0-0.023), respectively. CONCLUSIONS: This study showed a significant (P < 0.0001) dose-dependent reduction in the MLAC ofbupivacaine by sufentanil.  相似文献   

2.
PURPOSE: To determine the efficacy and safety of patient-controlled epidural analgesia of morphine or fentanyl in combination with bupivacaine for postoperative pain relief. METHODS: Forty ASA I-II patients scheduled for major abdominal surgery were studied. After insertion of a lumbar epidural catheter, patients were given a non-opioid general anaesthetic. After surgery patients complaining of pain, received a loading dose of 2 mg morphine (Group I) or 50 micrograms fentanyl (Group II). For continuing pain, 1 mg morphine in 4 ml bupivacaine 0.125% (0.25 mg.ml-1 morphine and 1 mg.ml-1 bupivacaine, Group I) or 20 micrograms fentanyl in 4 ml bupivacaine 0.125% (5 micrograms.ml-1 fentanyl and 1 mg.ml-1 bupivacaine Group II) were administered. Blood pressure, heart rate, respiratory rate and SpO2 were monitored. Assessments of pain (VAS), nausea-vomiting, motor block, pruritus and sedation were recorded for 24 hr. RESULTS: No difference in pain or sedation was observed between groups. The 24 hr postoperative opioid consumption was 15.50 +/- 7.53 mg morphine and 555.10 +/- 183.85 micrograms fentanyl. Total bupivacaine 0.125% consumption was 58.00 +/- 30.14 ml in Group I and 101.05 +/- 36.77 ml in Group II. One patient in Group II complained of motor weakness in one leg. The incidence of nausea (Group I 45%, Group II 10% P < 0.05) and pruritus (Group I 30%, Group II 5% P < 0.05) was less in patients receiving fentanyl. CONCLUSION: Both methods were effective in the prevention of pain but, because of fewer side effects, fentanyl may be preferable to morphine.  相似文献   

3.
The purpose of this study is to clarify the volume effect of epidural saline injection 20 min after spinal anesthesia. Thirty patients undergoing combined spinal and epidural anesthesia for orthopedic surgery were randomly divided into two groups: a control group (n = 15) and a saline group (n = 15). In the control group, 2% lidocaine 3 ml with 0.4% tetracaine was injected into the subarachnoid space from L 4-5 interspace using Durasafe (Becton Dickinson, USA) and saline was not injected into the epidural space. In the saline group, saline 10 ml was injected through an epidural catheter 20 min after spinal anesthesia. The levels of analgesia 20 min after spinal anesthesia were not significantly different between the groups. However, the levels of analgesia 3, 5, 10, 40 and 100 min after epidural saline injection in the saline group were significantly higher than those in the control group (P < 0.05). The highest analgesic level was obtained 10 min after epidural saline injection and reached to T 4.3 +/- 1.1. In conclusion, epidural saline injection increases the analgesic level 20 min after spinal anesthesia because of the volume effect.  相似文献   

4.
OBJECTIVE: To compare the intensity of postoperative pain after thoracotomy with 2 anesthetic techniques: 1) thoracic epidural block with bupivacaine administered before surgery (combined anesthesia with isoflurane) and 2) conventional balanced anesthesia with isoflurane and endovenous fentanyl. PATIENTS AND METHODS: Thirty patients scheduled for thoracotomy by lateral incision (T5-T6) were randomly divided into 2 groups of 15. Group A received 8 ml of 0.5% bupivacaine with adrenalin 1:200.000 30 min before start of surgery while group B received 8 ml saline solution through an epidural catheter inserted to T4-T8. Combined anesthesia (4 ml 0.5% bupivacaine through an epidural catheter 150 min after the first dose and isoflurane in 100% oxygen) was used in group A. Group B received balanced anesthesia with endovenous fentanyl 2.5 micrograms/kg and isoflurane in 100% oxygen. The difference in pain intensity during postoperative recovery was assessed by way of the following variables: number of boluses administered by epidural patient-controlled analgesia (bupivacaine 0.0625% and fentanyl 6 micrograms/ml); score on a visual analog scale of 10 at baseline and at 1, 3, 7, 11, 19 and 43 hours after surgery; and need for additional analgesia (diclofenac) during the 43 hours of study. Arterial gases were measured during the preoperative period and at 1, 3, 7, 19 and 43 hours after surgery. RESULTS: No significant differences in pain intensity measured on the visual analog scale, by the number of boluses per patients or by need for additional analgesia were found between the 2 groups. The total number of boluses administered and additional analgesic requirements were greater in the group receiving bupivacaine, although the difference was not significant (p = 0.095 and p = 0.056, respectively). Nor were there significant differences in pH and PaCO2 levels for the 2 groups. CONCLUSIONS: Analgesic efficacy after thoracotomy was similar for our 2 groups receiving either combined anesthesia (epidural bupivacaine at 0.5% and isoflurane) or balanced anesthesia with isoflurane and endovenous fentanyl.  相似文献   

5.
OBJECTIVES: To determine the efficacy and complications of continuous epidural perfusion of bupivacaine, adrenaline and fentanyl in the relief of pain during first and second stage labour during vaginal birth. PATIENTS AND METHODS: Between January 1990 and March 1993 we used continuous epidural perfusion for control of pain during labor in 1307 women. The solution administered through an epidural catheter and maintained until expulsion was one 10 ml bolus of bupivacaine 0.25% with adrenaline 1:200,000 and fentanyl 25 micrograms followed by continuous perfusion of bupivacaine 0.0625% with adrenaline 1:200,000 and fentanyl 2 micrograms/ml at an infusion rate of 12 ml/h. When analgesia was insufficient, a bolus of local anesthetic was administered or a pudendal block was carried out. RESULTS: Ninety-two percent of the birthing women reported good analgesic effect during the first stage; for 7% the effect was fair and for 0.55% it was poor. During the second stage 88% reported satisfactory analgesia, and 8% fair or poor. Assessment was not possible for the remaining women, who underwent cesarean sections. Complications were few and easily controllable. CONCLUSIONS: Maintenance of epidural perfusion with 0.0625% bupivacaine with adrenaline 1:200,000 and fentanyl 2 micrograms/ml provides sufficient analgesia during all stages of childbirth.  相似文献   

6.
We designed this double-blinded, randomized, controlled study to evaluate the effect of small-dose ketamine IV in combination with epidural morphine and bupivacaine on postoperative pain after renal surgery. An epidural catheter was inserted, and the administration of morphine and bupivacaine was started before surgery. Forty patients were assigned to one of two groups (ketamine or control). The ketamine group was administered a ketamine bolus and infusion during surgery. The median visual analog pain scale (VAS) scores at rest were significantly lower in the ketamine group during the first 6 h (P < 0.01). VAS pain scores on coughing were also significantly lower in the ketamine group (P < 0.01). Cumulative postoperative total analgesic consumption was less in the ketamine group on Days 1 and 2 (P < 0.001). The first analgesic demand time was shorter in the control group (9.2 +/- 11.5 min) than in the ketamine group (22.3 +/- 17.1 min) (P < 0.0001). The incidence of nausea and pruritus was more frequent in the control group (P < 0.05). In conclusion, postoperative analgesia was more effective when spinal cord and brain sensitization were blocked by a combination of epidural morphine/bupivacaine and IV ketamine. IMPLICATIONS: Renal nociception conducted multisegmentally by both the spinal nerves (T10 to L1) and the vagus nerve cannot be blocked by epidural analgesia alone. We demonstrated that IV ketamine had an improved analgesic or opioid-sparing effect when it was combined with epidural bupivacaine and morphine after renal surgery.  相似文献   

7.
The purpose of our study was to find out whether patient-controlled epidural administration (PCEA) of a mixture containing a low-dose local anaesthetic, opioid and alpha 2-agonist provides as good or better postoperative analgesia as continuous epidural administration of the same analgetic solution. METHODS: 30 patients (ASA I-III), scheduled for major abdominal surgery, were randomly divided into 2 groups. 90 minutes after induction of general anaesthesia all patients received a continuous epidural infusion of 5 ml/h of the analgetic solution (50 micrograms sufentanil + 150 micrograms clonidine in 50 ml 0.125% bupivacaine) until the end of surgery. Immediately postoperatively the patients of group A received a continuous infusion of the study solution (5-8 ml/h), the patients of group B received a baseline continuous epidural infusion (3 ml/h), additionally they could self-administer 5 ml boli via a PCEA device. Measurements included the total dose of infused drug solution, pain at rest and on exercise by a visual analogue scale, cardiorespiratory data and side effects within the first 24 hours postoperatively. A standardised interview on analgesia and side effects was held 2 days after surgery. RESULTS: The PCEA group demanded less epidural analgesics (gr. B: 112 +/- 33 ml vs. gr. A: 135 +/- 20 ml) p < 0.01). Both continuous epidural infusion and patient-controlled administration provided very good analgesia at rest (gr. A: VAS 0.4 +/- 0.4 and gr. B: VAS 0.4 +/- 0.5) (n.s.). On exercise continuous epidural infusion of analgesics resulted in significantly lower pain scores (gr. A: 1.9 +/- 1.1) than patient-controlled application (gr. B: 3.4 +/- 1.1) (p < 0.01). We did not notice severe side effects such as respiratory depression or drop of heart rate or blood pressure. CONCLUSION: In patients at rest both continuous and patient-controlled epidural administration of analgesics provides excellent analgesia after major abdominal surgery. Contrariwise, patients on exercise who could use a PCA-device experienced more pain compared to those with a continuous epidural infusion technique. On the other hand the patients of the PCA-group consumed less epidural analgesics. We did not notice any severe side effects such as respiratory depression or cardiovascular instability during the study.  相似文献   

8.
BACKGROUND: Basic pharmacological research indicates that there are synergistic antinociceptive effects at the spinal cord level between adrenaline, fentanyl and bupivacaine. Our clinical experience with such a mixture in a thoracic epidural infusion after major surgery confirms this. The objectives of the present study were to evaluate the effects on postoperative pain intensity, pain relief and side effects when removing adrenaline from this triple epidural mixture. METHODS: A prospective, randomised, double-blind, cross-over study was carried out in 24 patients after major thoracic or abdominal surgery. Patients with only mild pain when coughing during a titrated thoracic epidural infusion of about 10 ml.h-1 of bupivacaine 1 mg.ml-1, fentanyl 2 micrograms.ml-1, and adrenaline 2 micrograms.ml-1 were included. On the 1st and 2nd postoperative days each patient was given a double-blind epidural infusion, at the same rate, with or without adrenaline. The effect was observed for 4 h or until pain when coughing became unacceptable in spite of a rescue analgesic procedure. Rescue analgesia consisted of up to two epidural bolus injections per hour and i.v. morphine if necessary. All patients received rectal paracetamol 1 g, every 8 h. Fentanyl serum concentrations were measured with a radioimmunoassay technique at the start and end of each study period. Main outcome measures were extent of sensory blockade and pain intensity at rest and when coughing, evaluated by a visual analogue scale, a verbal categorical rating scale, the Prince Henry Hospital pain score, and an overall quality of pain relief score. RESULTS: The number of hypaesthetic dermatomal segments decreased (P < 0.001) and pain intensity at rest and when coughing increased (P < 0.001) when adrenaline was omitted from the triple epidural mixture. This change started within the first hour after removing adrenaline. After 3 h pain intensity when coughing had increased to unacceptable levels in spite of rescue analgesia (epidural bolus injections and i.v. morphine). Within 15-20 min after restarting the triple epidural mixture with adrenaline, pain intensity was again reduced to mild pain when coughing. Serum concentration of fentanyl doubled from 0.22 to 0.45 ng.ml-1 (P < 0.01), and there was more sedation during the period without adrenaline. CONCLUSIONS: Adrenaline increases sensory block and improves the pain-relieving effect of a mixture of bupivacaine and fentanyl infused epidurally at a thoracic level after major thoracic or abdominal surgery. Serum fentanyl concentrations doubled and sedation increased when adrenaline was removed from the epidural infusion, indicating more rapid vascular absorption and systemic effects of fentanyl.  相似文献   

9.
AIM OF STUDY: Intrathecal sufentanil has recently been used in labour as part of a combined spinal epidural technique. This study was conducted to compare its use in combination with bupivacaine for caesarean section with fentanyl added to bupivacaine and bupivacaine alone. METHODS: Sixty ASA I and II patients for non-emergency caesarean section under spinal anaesthesia were divided into three groups to receive 15 micrograms fentanyl added to 7.5 mg bupivacaine, 10 micrograms sufentanil added to 7.5 mg bupivacaine and 7.5 mg bupivacaine. Onset time of sensory blockade, side effects, surgical conditions, neonatal outcome and quality of the anaesthetic was assessed. On the first postoperative day, duration of effective analgesia, side effects and patient satisfaction were noted. RESULTS: The duration of effective analgesia of bupivacaine alone was prolonged with the addition of sufentanil and fentanyl by 358% and 256% respectively. No patient in the sufentanil and fentanyl groups required additional intra-operative analgesics compared with 17.6% of patients in the bupivacaine alone group. There was an increase in incidence of desaturation in the sufentanil group (45%) and fentanyl group (5.6%) compared with the bupivacaine only group (0%). The incidence of pruritus was 35% with sufentanil, 27.8% with fentanyl against 0% with bupivacaine alone. CONCLUSION: The addition of 10 micrograms of sufentanil and 15 micrograms of fentanyl to 7.5 mg of bupivacaine prolonged the duration of effective analgesia and improved intra-operative analgesia. However, the incidence of pruritus and episodes of desaturation were increased more with 10 micrograms sufentanil than with 15 micrograms fentanyl.  相似文献   

10.
The effectiveness of two epidural analgesic regimens on the ability to ambulate was compared in women in labor by a prospective, randomized, double-blind design. One group of patients received epidural fentanyl, a 75-micrograms bolus and an infusion of fentanyl 2.5 micrograms/mL at 15 mL/h (FENT, n = 53). A second group received ultra low-dose bupivacaine (0.04%), epinephrine (1.7 micrograms/mL), and fentanyl (1.7 micrograms/mL) (BEF, n = 77), a 15-mL bolus followed by an infusion at 15 mL/h. Adequate analgesia was rapidly obtained in 90.6% of patients in the FENT group and 92.2% of patients in the BEF group (P = 0.89). Seventy percent of patients in the FENT group ambulated versus 68% in the other group. The BEF mixture provided analgesia of longer duration (287 +/- 171 min versus 156 +/- 72 min, P = 0.0001). The number of patients delivering during administration of only their study drug (without needing higher doses of local anesthetics) was 52% for BEF and 21% for FENT (P = 0.0005). Hip flexion weakness precluding ambulation occurred in 17% (P = 0.002) of BEF patients and orthostatic hypotension in 9% (P = 0.08). Neither problem occurred in FENT patients. Neonatal outcome was similar in both groups. Approximately 70% of women receiving epidural analgesia with fentanyl or ultra low-dose bupivacaine, epinephrine, and fentanyl may ambulate safely during labor.  相似文献   

11.
In this prospective study we investigated the efficacy of microcatheter spinal anaesthesia in comparison with a combined spinal-epidural technique in trauma patients. METHODS: After institutional approval 60 patients undergoing urgent lower-limb surgery randomly received either CSA (22 G Sprotte needle, 28 G nylon catheter) in group 1 or CSE (18 G Tuohy needle, 22 G epidural catheter and 25 G pencil-point needle) in group 2. An initial subarachnoid bolus of 2 ml of plain bupivacaine 0.5% was injected in both groups. Difficulties with the lumbar puncture or catheter insertion, the time required for performance of either technique and the onset of analgesia at T12 were documented. If analgesia did not reach T12 within 20 min, supplemental bupivacaine was injected either intrathecally or epidurally up to a maximum of 5 ml in the CSA group or 16 ml in the CSE group. RESULTS: The number of lumbar punctures (CSA: n = 1.8 +/- 1.5; CSE: n = 2.6 +/- 1.8; P = 0.05) and the incidence of technical problems (CSA: 13%, CSE: 47%; P = 0.012) was higher in the CSE group. In contrast to CSA, performance of CSE was more time consuming (CSA: 8 +/- 3 min, CSE: 15 +/- 8 min; P = 0.0003), and the total dose of local anaesthetics was higher in the CSE group (CSA: 3.2 +/- 1 ml, CSE: 9.7 +/- 5 ml; P < 0.0001). CONCLUSIONS: Because of the higher incidence of technical problems, more time was required for the performance of CSE. As a consequence, microcatheter CSA might be preferred over CSE in trauma patients.  相似文献   

12.
The clinical value of the analgesic effect of opioids administered peripherally (except for intraarticular administration) has not been clearly demonstrated. The aim of this study was to test the hypothesis that fentanyl, added to a local anesthetic for wound infiltration, can enhance postoperative analgesia via a peripheral mechanism. Patients with inguinal herniorrhaphy performed under spinal anesthesia were randomly assigned to one of two groups (n = 10 each). At the end of surgery, the wound was infiltrated with 10 mL of lidocaine 0.5% and fentanyl 0.001% (10 microg) in one group; in the other group, the wound was infiltrated with 10 mL of lidocaine 0.5% alone (and fentanyl 10 microg IM contralaterally). The following variables were determined in a double-blind manner: the duration of anesthesia (response to a von Frey filament), the duration of analgesia (time to mild postoperative pain), postoperative meperidine consumption, intensity visual analog scale of spontaneous and movement-associated pain 24 h after surgery, and wound pain threshold 24 h after surgery (pressure algometry). The addition of fentanyl for wound infiltration enhanced the duration of anesthesia (130+/-37 vs 197+/-27 min; P < 0.001) and decreased the intensity of spontaneous (50+/-17 vs 19+/-18 mm; P < 0.002) and movement-associated (56+/-15 vs 26+/-21 mm; P < 0.002) pain 24 h postoperatively. Differences between groups for other variables were not statistically significant. Fentanyl added to a local anesthetic for wound infiltration after spinal anesthesia can enhance postoperative analgesia by a peripheral mechanism. IMPLICATIONS: Fentanyl can enhance analgesia by a peripheral mechanism. Added to a local anesthetic for wound infiltration, it may be of benefit for the relief of postoperative pain.  相似文献   

13.
Clinical picture of development of segmental blocking after subarachnoidal injection of hyperbaric solutions of 0.75% bupivacaine, 5% ultracaine, and isobaric 0.5% bupivacaine is studied. A total of 152 patients operated on the lower part of the body and the lower limbs were examined under conditions of single, prolonged subarachnoidal, and combined spinal epidural anesthesia. Ultracaine and bupivacaine in different concentrations with different barism provided anesthesia equivalent by the efficacy, depth, and dissemination of sensory block. Segmental blocking with 5% ultracaine was characterized by the shortest latent period (3.14 +/- 0.16 min, p < 0.05) but was no shorter (124.1 +/- 3.37 min) than operative analgesia with 0.75% hyperbaric bupivacaine (120.0 +/- 5.10 min). Isobaric bupivacaine provided the longest effective analgesia (215.0 +/- 45.0 min, p < 0.05). Microcatheter technique improved the safety and control of subarachnoidal anesthesia in comparison with a single injection, and combined spinal epidural anesthesia shortened the latent period of segmental blocking and ensured intraoperative anesthesia and postoperative analgesia at the expense of the epidural component.  相似文献   

14.
BACKGROUND: Intrathecal injection of local anesthetic agents is associated frequently with hypotension. Conversely, intrathecal administration of neostigmine increases blood pressure by enhancing the accumulation of acetylcholine in the spinal cord. The current study examined directly the interaction of intrathecal injection of bupivacaine and neostigmine on splanchnic sympathetic efferent nerve activity. METHODS: Experiments were performed in rats with intrathecal catheters implanted for the long-term. Rats were anesthetized with ketamine (40 mg/kg, intramuscularly) and alpha-chloralose (60 mg/kg, intraperitoneally). The skin incision sites were infiltrated with 1% lidocaine. Sympathetic efferent activity was recorded from the left greater splanchnic nerve. Sympathetic nerve activity was measured continuously before and after intrathecal injection of saline, 430 nmol (140 microg) of bupivacaine, 25 nmol (7.6 microg) of neostigmine, and a combination of bupivacaine and neostigmine all in volumes of 5 microl. Each group consisted of six animals. RESULTS: Compared with baseline nerve activity, intrathecal injection of neostigmine increased splanchnic sympathetic nerve activity significantly by (mean +/- SEM) 112 +/- 29% after an onset latency of 6.8 +/- 0.9 min. In contrast, bupivacaine decreased splanchnic nerve activity significantly (-65 +/- 13%) after a latency of 3.3 +/- 0.5 min after intrathecal administration. Similar to the effect of saline, intrathecal coadministration of bupivacaine and neostigmine did not alter the splanchnic sympathetic nerve activity significantly. CONCLUSIONS: The current study provides electrophysiologic evidence that intrathecal injection of neostigmine increases whereas bupivacaine decreases sympathetic nerve activity. Further, addition of neostigmine effectively counteracts the inhibitory effect of spinal bupivacaine on the sympathetic nerve activity.  相似文献   

15.
BACKGROUND: Clonidine produces analgesia by actions on alpha 2-adrenoceptors and enhances both sensory and motor blockade from epidural injection of local anaesthetics. Low-dose clonidine has been used so far for caudal injection in children. Our aim was to study the perioperative effects of high-dose caudal clonidine when added to low concentration of bupivacaine for combined epidural and general anaesthesia in children. METHODS: After induction of general anaesthesia caudal block was performed either with 1 ml.kg-1 bupivacaine 0.175% with the addition of clonidine 5 micrograms.kg-1 (n = 20), or with 1 ml.kg-1 bupivacaine 0.175% (n = 20). The intraoperative anaesthetic requirements, the perioperative haemodynamic effects, respiratory rate, sedation score, postoperative pain scores and side effects were assessed by a blinded observer. A patient-controlled analgesia system was used for postoperative pain relief. The quality of postoperative pain relief was assessed using Smiley's pain analogue scale. RESULTS: Intraoperative haemodynamic responses did not differ between the groups. However, during emergence from general anaesthesia children in the clonidine group had significantly lower heart rates and blood pressure compared to children in the control group. In addition, heart rates and blood pressures were also lower in the clonidine group in the early postoperative period (P < 0.05). Postoperative analgesia was significantly better in the clonidine group as evidenced by the total number of requests (3 vs 12, P < 0.05) and the total amount of tramadol (20.5 mg vs 72.8 mg, P < 0.05) administered. The duration of the caudal analgesia was significantly longer in the clonidine group (20.9 +/- 7.4 h vs 14.4 +/- 10.9 h, P < 0.05). CONCLUSION: Our results suggest that caudal clonidine 5 micrograms.kg-1 enhances and prolongs caudal blockade with bupivacaine (1.175% in children. It also blocks sympathoadrenergic responses during emergence from anaesthesia. Sedation and cardiovascular effects are observed up to 3 h into the postoperative period.  相似文献   

16.
Very small doses of intrathecal (i.t.) morphine (25-200 microg) have been used in an effort to provide effective postoperative pain relief while minimizing side effects after cesarean delivery. We performed a double-blinded study in 40 patients presenting for elective cesarean delivery in which i.t. morphine was administered along with oral hydrocodone/acetaminophen and other medications commonly administered after cesarean delivery. We administered i.t. morphine by up-down sequential allocation of doses. For the purposes of this study, adequate postoperative analgesia was defined as comfort not requiring i.v. morphine for 12 h after spinal anesthesia with bupivacaine, fentanyl, and morphine. In addition, a time and cost comparison was performed for study patients receiving intrathecal morphine compared with a historical group of patients receiving patient-controlled analgesia with i.v. morphine. We were unable to determine with meaningful precision a dose of i.t. morphine to provide analgesia in this context. However, very small doses of i.t. morphine combined with oral hydrocodone/acetaminophen and other medications commonly prescribed after cesarean delivery provided postoperative pain relief with no more time commitment than patient-controlled analgesia (148 +/- 61 vs 150 +/- 57 min) and with significantly less acquisition cost ($15.13 +/- $4.40 vs $34.64 +/- $15.55). Implications: When used along with oral analgesics, very small doses of spinal morphine provide adequate pain relief after cesarean delivery. Spinal anesthetics, oral analgesics, and other medications commonly prescribed to treat side effects after cesarean delivery contribute significantly to this analgesia. When small doses of spinal morphine are used in this setting, they provide adequate analgesia and patient satisfaction that is time- and cost-effective.  相似文献   

17.
STUDY OBJECTIVE: Part 1: To measure ropivacaine levels in the mother and infant at delivery after continuous lumbar epidural infusion. Part 2: To compare epidural ropivacaine to epidural bupivacaine for labor analgesia in regard to effectiveness, motor blockade, and maternal and neonatal effects. DESIGN: Part 1: Open-labelled, non-blind study. Part 2: Randomized, double-blind study. SETTING: Labor and delivery units of two academic hospitals. PATIENTS: Part 1: 20 ASA physical status I and II parturients in active labor. Part 2: 81 ASA physical status I and II parturients in active labor. INTERVENTIONS: For Part 1, 8 to 12 ml of 0.25% ropivacaine was administered through a lumbar epidural catheter to achieve a T10 dermatomal sensory level. An infusion of 0.25% ropivacaine, 8 to 10 ml/hr, maintained this sensory level. Maternal and umbilical cord blood samples obtained at delivery were analyzed for ropivacaine concentration. For Part 2, anesthetic management was similar to that previously described except patients were randomized to receive either 0.25% ropivacaine or 0.25% bupivacaine. Onset, regression, maximal spread of sensory block, and onset and degree of motor blockade were measured. Contraction pain as assessed using a visual analog scale (VAS), maternal blood pressure, and heart rate were determined every 5 minutes until a stable VAS-contraction score was achieved, and every 30 minutes thereafter. Neonatal assessment included Apgar scores and neurologic and adaptive capacity scores (NACS) at 15 minutes, 2 hours, and 24 hours. MEASUREMENTS AND MAIN RESULTS: For Part 1, the total and free maternal arterial concentrations of ropivacaine at delivery were 0.64 +/- 0.14 microgram/ml and 0.10 +/- .02 microgram/ml, respectively; the umbilical venous total and free concentrations were 0.19 +/- 0.03 microgram/ml and 0.12 +/- 0.07 microgram/ml, respectively (n = 12). The umbilical arterial and venous concentrations did not differ for both the free and total concentrations. For Part 2, there was no difference between ropivacaine and bupivacaine in the variables measured. Umbilical cord gases and Apgar scores were not different between the two groups; NACS were higher at 15 minutes and 2 hours in the ropivacaine group (p < 0.05) than the bupivacaine group. CONCLUSION: Both ropivacaine and bupivacaine produced excellent analgesia for labor with no major adverse effect on the mother or neonate.  相似文献   

18.
BACKGROUND: The purpose of the study was to compare the analgesic and side effects of two epidurally administered mixtures of bupivacaine and fentanyl with the same drug ratios. METHODS: One hundred patients scheduled for colorectal surgery were randomized to receive a thoracic epidural infusion of either bupivacaine 0.12% with fentanyl 2 micrograms/ml or bupivacaine 0.24% with fentanyl 4 micrograms/ml during 48 h postoperatively. The pumps were adjusted to keep the visual analogue scale (VAS) pain score at 3 or less (on a scale of 0-10) with a minimum of adverse effects. RESULTS: There were no statistically significantly differences between the two groups in VAS pain scores. The average VAS pain score resting varied between 0.5 and 1, and coughing between 1.9 and 3.4. One case of respiratory depression with breathing frequency 7 occurred in each group, but none of the patients required naloxone. One patient in the low concentration group developed partial motor weakness in both legs 36 h postoperatively. Equal drug amounts--bupivacaine 10.8-11 mg/h and fentanyl 18-18.4 micrograms/h--were given in both groups throughout the study. CONCLUSIONS: Both groups had low pain scores with few and comparable adverse effects. It thus seems that the volume is not important when mixtures of bupivacaine and fentanyl in the studies concentrations are infused epidurally at a low thoracic level. Practical reasons favour the higher concentration mixture.  相似文献   

19.
Epidural analgesia for pain relief during labour has certain disadvantages including slow onset. However, intrathecal sufentanil provides rapid onset and well-controlled analgesia lasting 1-4 h. The aim of this study was to compare the analgesia and the side effects of intrathecal sufentanil with epidural bupivacaine during labour. In a randomized, double-blind and controlled trial 58 parturient women requesting analgesia during labour were studied. The patients received either intrathecal sufentanil 10 micrograms and epidural saline, or intrathecal saline and epidural bupivacaine 20 mg. Visual analogue scores (VAS) for pain, blood pressure, heart rate, respiratory rate, level of sedation and the incidence of pruritus and nausea were recorded. Pain scores were significantly lower between 5 and 90 min after injection in patients receiving intrathecal sufentanil. Pruritus was significantly more frequent among those receiving intrathecal sufentanil. The rapid onset and effective analgesia of intrathecal sufentanil may in certain situations be advantageous.  相似文献   

20.
The effect of epidural infusions containing fentanyl on maternal gastric emptying in labour was examined using the rate of paracetamol absorption. Women were randomly allocated to receive one of two epidural infusions, bupivacaine 0.125% alone or bupivacaine 0.0625% with fentanyl 2.5 micrograms.ml-1 at a rate of 10-12 ml.h-1. Paracetamol 1.5 g was given orally to women after either 30 ml of the infusion solution had been given (mean time 2.5 h, study A) or 40-50 ml (mean time 4.5 h. study B). Six venous blood samples were taken over the next 90 min for measurement of plasma paracetamol concentration. There were no significant differences in maximum plasma paracetamol concentration, time to maximum paracetamol concentration and area under the concentration-time curve between the two groups for study A. In study B the time to maximum plasma paracetamol concentration was significantly delayed in women receiving > 100 micrograms fentanyl compared with controls (p < 0.05). We conclude that the dose of fentanyl that may delay gastric emptying when given by epidural infusion is greater than 100 micrograms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号