首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 400 毫秒
1.
The efficacy of percutaneous CT-guided needle biopsies was investigated in 68 patients with pulmonary lesions and in 65 patients with mediastinal masses. In comparison with conventional multisectional CT, the time needed for the localization of the needle tip could be reduced by use of spiral CT. Comparing aspiration and cutting biopsy needle we achieved a higher accuracy of 94% in case of mediastinal masses and of 90% by using cutting needles. The rate of complications, such as pneumothoraces, is relatively low.  相似文献   

2.
OBJECTIVE: The purpose of our study was to assess the accuracy of CT-guided biopsy of musculoskeletal neoplasms with respect to technique, anatomic site, and histology. MATERIALS AND METHODS: During a 3-year period (January 1992 to December 1994), 176 core needle biopsies and 45 fine-needle aspirations were performed under CT guidance on patients with musculoskeletal neoplasms. To assess the accuracy of these procedures, we compared the diagnosis at biopsy with the final diagnosis as determined at the time of definitive treatment of the lesion. All biopsy findings were categorized as a primary malignancy (excluding round cell lesions), round cell lesion, local recurrence, or metastatic carcinoma. In addition, each lesion was analyzed according to which biopsy technique was used, whether frozen tissue section or rapid cytologic evaluation was used, and at which anatomic site the mass was found. RESULTS: The accuracy for needle biopsy was 93% and that for fine-needle aspiration was 80%. The complication rate for both techniques was less than 1%. Accuracy rates for the four categories of primary malignancy, round cell lesion, local recurrence, and metastatic carcinoma were 87%, 75%, 94%, and 100%, respectively. The mismatch rates were similar in soft-tissue lesions (5/52) and bone lesions (16/169). Diminished accuracy was associated with round cell lesions (20%) and lesions located in the spine or the perivertebral region (20%). Nondiagnostic and insufficient specimens were found in 18 (8%) of the 221 patients. CONCLUSION. CT-guided biopsy of musculoskeletal malignancies is a safe and effective procedure if performed by a team of clinicians, pathologists, and radiologists who possess subspecialty expertise.  相似文献   

3.
Since February 1987 percutaneous CT-guided spine biopsy was performed in 18 patients with spondylodiscitis at the X-ray Department of Bispebjerg Hospital. Eleven cases were spontaneous and seven followed spinal surgery. The infection was located in five cases in the thoracic spine and in 13 cases in the lumbar spine. Only one biopsy was performed during general anaesthesia, the rest under local anaesthesia. No complications were observed. The bioptic material was cultivated immediately beside the patient and incubated for 14 days. The infective organism was isolated in 12 cases (67%). Thus, material obtained through a fine needle was satisfactory for microbiological investigation. A biopsy is crucial for establishing a microbiological diagnosis and thereby enabling prompt adequate treatment.  相似文献   

4.
OBJECTIVE: The aim of this study was to investigate the results of ultrasound-guided fine needle biopsy of pancreatic masses in a large multicenter series. METHODS: This study collected the data of 510 patients who had a final diagnosis available and who had undergone ultrasound-guided fine needle biopsy of the pancreas. Retrieval rate, sensitivity, specificity, and overall diagnostic accuracy of the whole series, by three different bioptic procedures (cytology, histology, and cytology plus histology) were evaluated. The reliability of ultrasound-guided fine needle biopsy to allow a correct diagnosis in the different pancreatic pathologies was calculated. Finally, any complications were collected. RESULTS: For cytology, histology, and cytology plus histology, retrieval rate values were: 94%, 96%, and 97%; sensitivity was: 87%, 94%, and 94%, specificity: 100%; and diagnostic accuracy: 91%, 90%, and 95%, respectively. Ultrasound-guided fine-needle biopsy correctly diagnosed all the cases of pancreatic metastases or non-Hodgkin's lymphoma (23 of 510 cases as 5%; in eight of 23 it led to the first diagnosis of the primary tumor) and all the cases of abscesses, 97% of the cases of pseudocysts, 86% of pancreatic adenocarcinomas, 62% of cystic neoplasms, 35% of the cases of chronic pancreatitis (in this case, the bioptic procedures were reviewed), and 33% of neuroendocrine tumors. There were complications in one case of asymptomatic peripancreatic hematoma, three cases of vaso-vagal reactions, and 21 cases of pain. CONCLUSION: Ultrasound-guided fine needle biopsy of the pancreas is efficacious, without any difference between the various bioptic modalities (with the exception of chronic pancreatitis, in which histology is better). The technique is safe. Moreover, the procedure allows the identification of patients affected by pancreatic tumors other than adenocarcinoma (in our survey 5% of the total); in about one third of these patients it leads to the diagnosis of the primary tumor, thus avoiding inappropriate treatments.  相似文献   

5.
Bone biopsy is necessary for the diagnosis of ambiguous skeletal lesions. Although several merits of computed tomography (CT)-guided percutaneous needle biopsy have been documented, few radiologists have performed this procedure in Japan. We performed this procedure with a newly introduced bone biopsy needle (OSTYCUT, angiomed, Karlsruhe, Germany) under CT guidance and evaluated the results. CT-guided bone biopsy (pelvic[n = 11]vertebral[n = 10], femoral[n = 1], sternal[n = 1]) was performed in 19 consecutive patients. Seventeen patients were suspected metastatic disease, and the others were suspected primary bone tumor. All biopsies but one were diagnostic. Malignancy was proved in 11 lesions. Three patients with prostatic carcinoma were proved to show no malignancy of bone lesions after a series of hormonal and chemotherapies. In one patient with both malignant mesothelioma and cervical carcinoma, the biopsy specimen from thoracic vertebra proved metastasis from mesothelioma. CT-guided bone biopsy is useful to evaluate the presence of malignancy and the effect of therapy for it, and to determine the primary site.  相似文献   

6.
OBJECTIVE: This study was performed to compare two proposed algorithms used when evaluating an adrenal mass discovered during staging evaluation of a patient with a known malignancy. Such evaluation was meant to lead to determination of the relative charges associated with each algorithm. SUBJECTS AND METHODS: Fifty-four patients with known malignancies who required evaluation of an adrenal mass underwent both chemical shift imaging (CSI) and CT-guided for CSI. The hospital charges incurred for each procedure and any associated complications were normalized using national relative-value scale charges and conversion factors. A decision analysis was performed to compare the relative charges that would have been incurred if adrenal MR imaging had been performed in all patients, followed by CT-guided biopsy only in those patients with MR findings not diagnostic of adrenocortical adenoma, and the relative charges incurred if only CT-guided adrenal biopsy had been performed in every patient. RESULTS: Twenty-three (43%) of 54 adrenal masses were shown to be metastases by CT-guided biopsy. The sensitivity and specificity of CSI for the diagnosis of adrenocortical adenoma were 94% and 100%, respectively. The charges incurred by performing MR imaging as the initial examination with subsequent CT-guided biopsy only in those patients with CSI findings not diagnostic of adenoma would have been similar to those incurred by first performing CT-guided adrenal biopsy in every patient. CONCLUSION: CSI is an accurate, noninvasive technique for evaluating adrenal masses in patients with cancer. If CT-guided biopsy is used only when CSI is not diagnostic of adrenocortical adenoma, the associated charges would be virtually the same as when CT-guided biopsy is performed as the first test in every patient. Moreover, biopsies could have been avoided in 54% of these patients.  相似文献   

7.
We performed percutaneous vertebral biopsy on 18 patients (March 1978 to March 1992) using a Craig trephine needle under fluoroscopic control, a more reliable and safer procedure than open vertebral body biopsy. Material for histopathologic examination was obtained in 17 of the 18 patients and there were no complications. Possible complications involve mostly in the cervical and dorsal spine. They can be prevented by using very precise and delicate technique under reliable fluoroscopic control in the operating room.  相似文献   

8.
OBJECTIVE: Our objective was to determine the diagnostic and cost efficacy of sonographically guided mediastinal biopsy as an alternative to CT-guided mediastinal biopsy and to review our biopsy triage experience in switching from CT to sonography. CONCLUSION: Sonography is as safe and accurate as CT and is 25% less costly than CT. Sonography proved particularly valuable for identifying vessels and perfused tissue and for permitting upright biopsy positions in dyspneic patients. When using our triage criteria, radiologists should find sonographically guided mediastinal biopsy to be an attractive alternative to CT-guided mediastinal biopsy in most patients.  相似文献   

9.
RATIONALE AND OBJECTIVES: The purpose of this study was to determine whether laser-guided computed tomographic (CT) biopsy is more accurate than CT-guided biopsy with conventional freehand techniques. MATERIALS AND METHODS: Two independent operators performed an equal number of freehand and laser-guided needle passes at varying single and double angles (0 degree, 30 degrees, 60 degrees, 25 degrees/30 degrees, and 25 degrees/60 degrees) on targets within six pork and beef phantoms. A total of 180 biopsy passes were performed, and error distances of needle tip to target were tabulated. Data were analyzed by means of repeated measures analysis of variance (ANOVA) to compare the accuracy of laser guidance with freehand passes. ANOVA and correlation analysis were also used to confirm the relative equivalency of phantom targets and biopsy parameters. RESULTS: Overall, laser-guided passes were statistically significantly more accurate than freehand passes. Mean error with laser guidance was 5.01 mm (standard error [SE] = 0.41 mm), whereas mean error with freehand techniques was 10.58 mm (SE = 0.82 mm) (F = 52.0, df = 1.17, P = .0001). Ninety-three percent of laser-guided passes and 56% of freehand passes were within 1 cm of the intended target. Error increased for both laser-guided and freehand techniques with larger angles or double-angle biopsies, but the increases were greater with freehand technique. No statistically significant differences existed between the targets themselves or biopsy parameters for the two operators. CONCLUSION: Laser-guided CT biopsies were more accurate than freehand CT biopsies. Practical advantages of laser guidance over freehand CT biopsy methods may include decreased procedure times and reduced patient morbidity.  相似文献   

10.
RATIONALE AND OBJECTIVES: The authors evaluate the role of immediate cytologic evaluation (ICE) with fine-needle aspiration biopsy (FNAB) for lung lesions at highest risk for pneumothorax. METHODS: A prospective randomized study was conducted of 80 patients with lung lesions surrounded by aerated parenchyma undergoing FNAB with and without ICE (47 and 33 patients, respectively). An analysis of needle passes, procedure time, complications, specimen adequacy, diagnostic yield, and accuracy of procedure was made. RESULTS: There was an increased number of needle passes with ICE (> or = three passes: 23% [11 biopsies] versus 3% [1 biopsy]; P = 0.01). Fluoroscopic procedures took longer with ICE (median time: 15 versus 9 minutes; P = 0.002) with no difference in complication rates. Specimen adequacy was similar (74% and 64%) and the procedure was diagnostic in 79% (37 biopsies) with ICE and in 70% (33 biopsies) without ICE. There were no significant differences in the sensitivity, specificity, or accuracy of the biopsy. CONCLUSIONS: Immediate cytologic evaluation improved results marginally with increased procedure time and needle passes. Immediate cytologic evaluation may be most useful for lesions at lowest risk of complications to assure that a second procedure is not required.  相似文献   

11.
AIMS: We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. PATIENTS AND METHODS: Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. RESULTS: Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. CONCLUSIONS: Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.  相似文献   

12.
Using a computed tomography (CT)-guided technique we have been able to obtain fine needle spine biopsies directly from an affected vertebra or disk plate in 14 patients suspected of infectious spondylitis. The bioptic material was cultivated immediately and incubated for 14 days. Cultures from eight patients were positive. No single microbiological agent was predominant though coagulase-negative staphylococci were frequent. In no case were mycobacteria found. Bioptic material from six patients did not give rise to growth of microorganisms. We were able to successfully treat the eight patients with a culture-positive biopsy. We think that biopsies are crucial for establishing a microbiological diagnosis. The whole procedure takes less than one hour; it is performed under local anaesthesia and is thus not very stressful for the patient: The success rate for obtaining a positive spine biopsy was 57%.  相似文献   

13.
Two thyroidectomized patients with a history of differentiated thyroid carcinoma are presented who had nonmetastatic mediastinal 131I uptake following therapeutic doses of 131I. Chest CT scans in both patients demonstrated an anterior mediastinal mass. Surgical excision in one patient and a percutaneous CT-guided fine needle aspiration biopsy in the other disclosed normal thymus tissue. Iodine-131 uptake in the anterior mediastinum in patients thyroidectomized for follicular or papillary thyroid carcinoma may represent the thymus.  相似文献   

14.
OBJECTIVE: The purpose of this study is to examine the accuracy and complications of transthoracic needle aspiration biopsy (TTNA) to determine its optimal role in the evaluation of patients with lung tumors. MATERIALS AND METHODS: The charts of 130 consecutive patients who had undergone CT-guided TTNA were reviewed retrospectively. Thirty-two (25%) of these patients had subsequent surgery and 5 had subsequent transbronchial biopsy (TBB). Using the final surgical and TBB diagnosis as a reference, the accuracy, sensitivity, specificity, and prevalence of malignancy were calculated. Each case was also examined to determine the presence or absence of complications. RESULTS: Of the 130 biopsy results, 95 (73%) were malignant, 33 (25%) were nonspecific, and only 2 (2%) had a specific benign diagnosis. Thirty-two patients subsequently underwent surgical resection. The overall prevalence of malignancy after surgical diagnosis was 91%. The overall diagnostic accuracy of TTNA was 76%. The sensitivity of TTNA for the detection of malignancy was 74% and its specificity was 100%. When comparing TTNA results of small (<3 cm) and large (> or = 3 cm) tumors, the occurrence of nonspecific results was 36% and 16%, respectively. Fifty-six (43%) patients had a pneumothorax subsequent to TTNA. Twenty-four (43%) of these patients required a chest tube and remained hospitalized for a mean of 6 days. CONCLUSION: Patients who are surgical candidates and have a high clinical suspicion for malignancy should undergo surgical biopsy and resection of their lung tumors if indicated. Information gained from TTNAs performed on this patient population will rarely result in a change in their clinical management.  相似文献   

15.
OBJECTIVE: This investigation was performed to test the hypotheses that interactive guidance of MR image acquisition during needle-directed procedures using a clinical 0.2-T C-arm open MR imaging system integrated with a frameless optically linked stereotaxy system is feasible, and that procedure times can be sufficiently short to be well tolerated by the patient. SUBJECTS AND METHODS: One hundred six MR-guided procedures were performed in 86 patients (ranging in age from 5 months to 88 years) using a clinical C-arm imaging system supplemented with an in-room RF-shielded liquid crystal display monitor, a frameless stereotaxy system, rapid gradient-echo sequences for needle guidance, and MR-compatible monitoring and surgical lighting equipment. We performed 50 biopsies and aspirations of the head and neck in 37 patients, 23 biopsies of musculoskeletal lesions in 22 patients, 16 biopsies of abdominal sites in 10 patients, six biopsies of the thoracolumbar spine or sacrum in six patients, and 11 shoulder joint injections for MR arthrography in 11 patients, in addition to 38 MR arthrographic injections on the same imaging system described in a previous report. Tissue sampling included fine-needle aspiration (n = 90) and cutting needle core biopsy (n = 41). Thirty-five patients underwent both procedures. Procedures were evaluated for success of needle placement, procedure time, and complications. RESULTS: Needle placement was successful in all cases, and no complications occurred. Tissue was sufficient for pathologic diagnosis for all but eight patients. Passes per patient averaged 2.1. For fine-needle aspiration, instrument time averaged 7 min 42 sec per pass, cutting needle core biopsy averaged 6 min 24 sec, and shoulder injection averaged 8 min. CONCLUSION: MR imaging guidance for needle procedures on a clinical 0.2-T C-arm system with supplemental interventional accessories is feasible, with relatively rapid needle placement.  相似文献   

16.
17.
BACKGROUND: Radiologically guided needle biopsy and cytologic evaluation provide a reliable method of diagnosis for planning definitive therapy of patients with mediastinal lesions. MATERIALS AND METHODS: In this retrospective study of one of the largest series from a single institution, 141 consecutive mediastinal needle biopsies from 139 patients were reviewed during a 15-year period. RESULTS: Adequate material was obtained with a diagnosis achieved in 128 cases (92%). Of these, 33 cases (26%) had benign diagnoses; the remaining 95 (74%) had malignant diagnoses, including 81 carcinomas, 3 sarcomas, 8 lymphoproliferative lesions, 2 malignant germ cell tumors, and 1 malignant thymoma. All benign cases were diagnostically confirmed, and 94 of 95 malignant cases were classified correctly. The only discrepancy that occurred involved a malignant lymphoma diagnosed as a malignant germ cell tumor. Of the 13 inadequate samples, the major category included a nodular sclerosis variant of Hodgkin's disease (4 cases), 1 case of thymoma, 1 case of tuberculous lymphadenitis, and 7 cases for which no follow-up data were available. CONCLUSION: Needle biopsy is reaffirmed as a reliable and sensitive diagnostic tool for mediastinal lesions, with an overall cytologic diagnostic accuracy of 99% with adequate material. Sclerotic lesions may pose a limitation to this technique and require generous sampling before a more invasive diagnostic procedure is undertaken.  相似文献   

18.
The purpose of this paper is to establish diagnostic value of percutaneous needle biopsy in patients with vertebral tumours treated in Department of Neurosurgery in Poznań between 1975 and 1996. Radiological examinations: X-rays, plain X-rays, CT and MR, demonstrated vertebral destruction and allowed needle biopsy performance. The most frequent destruction was observed in thoracic region (45% of cases), rarely--in sacral bone (5%). In cases with single neoplastic focus, only in vertebral body, histological diagnosis by needle biopsy was achieved in 70% of cases. However in patients with paravertebral tumour positive results of needle biopsy were higher--82% of cases.  相似文献   

19.
PURPOSE: The diagnostic accuracy and rate of complications of CT-guided core biopsies (CB) from suspected tumors of the chest were compared to the accuracy a complications of fine-needle aspiration biopsies (FNAB). METHODS: The accuracy in the diagnosis of a benign or malignant lesion of 79 FNAB (19.5 G self-aspirating cutting needle) and of 83 CB (18 G automated core biopsy) and the rates of pneumothorax, pleural drainage and hemoptysis were retrospectively evaluated. RESULTS: With FNAB, the sensitivity for malignant lesions was 62.1% and the accuracy 68.4%. With CB the sensitivity amounted to 85.9% and accuracy to 86.7%. The rate of pneumothorax was 25.3% following FNAB, with a drainage rate of 5.1% compared to 19.3% and 6.0%, respectively, following CB. The rate of pneumothorax and drainage increased with increasing path length through aerated lung. In advanced emphysema, the pneumothorax rate did not increase; however, in pneumothoraces, pleural drainage was mandatory in 20% of FNAB and in 100% of CB. Hemoptysis without any therapeutic consequences occurred in 3.8% following FNAB and in 6.0% following CB. CONCLUSIONS: With CB diagnostic accuracy can be clearly increased without an obvious increase in the complication rate. However, in patients with obvious emphysema, the pleural drainage rate of pneumothorax may be higher following CB.  相似文献   

20.
We describe a technique for conducting a CT-guided biopsy of the brachial plexus region, report two illustrative cases, discuss potential complications, and conclude that, in selected cases, biopsy of lesions in the region of the brachial plexus can be performed safely with CT guidance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号