首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The slow development of cost-effective medical microdevices with strong analytical performance characteristics is due to a lack of selective and efficient analyte capture and signaling. The recently developed programmable bio-nano-chip (PBNC) is a flexible detection device with analytical behavior rivaling established macroscopic methods. The PBNC system employs ≈300 μm-diameter bead sensors composed of agarose "nanonets" that populate a microelectromechanical support structure with integrated microfluidic elements. The beads are an efficient and selective protein-capture medium suitable for the analysis of complex fluid samples. Microscopy and computational studies probe the 3D interior of the beads. The relative contributions that the capture and detection of moieties, analyte size, and bead porosity make to signal distribution and intensity are reported. Agarose pore sizes ranging from 45 to 620 nm are examined and those near 140 nm provide optimal transport characteristics for rapid (<15 min) tests. The system exhibits efficient (99.5%) detection of bead-bound analyte along with low (≈2%) nonspecific immobilization of the detection probe for carcinoembryonic antigen assay. Furthermore, the role analyte dimensions play in signal distribution is explored, and enhanced methods for assay building that consider the unique features of biomarker size are offered.  相似文献   

2.
In fluorescence‐based assays, usually a target molecule is captured using a probe conjugated to a capture surface, and then detected using a second fluorescently labeled probe. One of the most common capture surfaces is a magnetic bead. However, magnetic beads exhibit strong autofluorescence, which often overlaps with the emission of the reporter fluorescent dyes and limits the analytical performance of the assay. Here, several widely used magnetic beads are photobleached and their autofluorescence is reduced to 1% of the initial value. Their autofluorescence properties, including their photobleaching decay rates and autofluorescence spectra pre‐ and post‐photobleaching, and the stability of the photobleaching over a period of two months are analyzed. The photobleached beads are stable over time and their surface functionality is retained. In a high‐sensitivity LX‐200 system using photobleached magnetic beads, human interleukin‐8 is detected with a threefold improvement in detection limit and signal‐to‐noise ratio over results achievable with nonbleached beads. Since many contemporary immunoassays rely on magnetic beads as capture surfaces, prebleaching the beads may significantly improve the analytical performance of these assays. Moreover, nonmagnetic beads with low autofluorescence are also successfully photobleached, suggesting that photobleaching can be applied to various capture surfaces used in fluorescence‐based assays.  相似文献   

3.
Defined hierarchical materials promise cell analysis and call for application‐driven design in practical use. The further issue is to develop advanced materials and devices for efficient label‐free cell capture with minimum instrumentation. Herein, the design of hierarchical beads is reported for efficient label‐free cell capture. Silica nanoparticles (size of ≈15 nm) are coated onto silica spheres (size of ≈200 nm) to achieve nanoscale surface roughness, and then the rough silica spheres are combined with microbeads (≈150–1000 µm in diameter) to assemble hierarchical structures. These hierarchical beads are built via electrostatic interaction, covalent bonding, and nanoparticle adherence. Further, after functionalization by hyaluronic acid (HA), the hierarchical beads display desirable surface hydrophilicity, biocompatibility, and chemical/structural stability. Due to the controlled surface topology and chemistry, HA‐functionalized hierarchical beads afford high cell capture efficiency up to 98.7% in a facile label‐free manner. This work guides the development of label‐free cell capture techniques and contributes to the construction of smart interfaces in bio‐systems.  相似文献   

4.
Multiplexed bead-based assays, using fluorescent dye-encoded beads, are finding widespread use in various profiling studies. The need to measure multiple quantitative responses simultaneously, the development of less expensive commercial flow systems, and the ease and cost effectiveness of manufacturing bead profiling kits of varied composition have all contributed to the popularity of this assay format. Maximizing the level of multiplexing in these assays requires tight spacing of fluorescent bead populations, and this leads to some degree of overlap or "encroachment" between populations. The degree to which encroachment affects analyte signal determinations depends upon both the extent of overlap and the relative analyte signals associated with the populations. In the work reported here, the impact of encroachment upon analyte signal for a subset of beads belonging to a multiplexed cytokine assay has been modeled and empirically evaluated.  相似文献   

5.
The novel application of two‐dimensional (2D) single‐layer ternary chalcogenide nanosheets as “capture‐release” fluorescence‐based biomolecular nanosensors is demonstrated. Fluorescently labeled biomolecular probe is first captured by the ultrathin Ta2NiS5 nanosheets and then released upon adding analyte containing a target biomolecule due to the higher probe‐target affinity. Here, the authors use a nucleic acid probe for the model target biomolecule Plasmodium lactate dehydrogenase, which is an important malarial biomarker. The ultrathin Ta2NiS5 nanosheet serves as a highly efficient fluorescence quencher and the nanosensor developed from the nanosheet is highly sensitive and specific toward the target biomolecule. Apart from the specificity toward the target biomolecule in homogeneous solutions, the developed nanosensor is capable of detecting and differentiating the target in heterogeneous solutions consisting of either a mixture of biomolecules or serum, with exceptional specificity. The simplicity of the “capture‐release” method, by eliminating the need for preincubation of the probe with the test sample, may facilitate further development of portable and rapid biosensors. The authors anticipate that this ternary chalcogenide nanosheet‐based biomolecular nanosensor will be useful for the rapid detection and differentiation of a wide range of chemical and biological species.  相似文献   

6.
The development of a powerful immunoassay platform with capacities of both simplicity and high multiplexing is promising for disease diagnosis. To meet this urgent need, for the first time, a multiplexed luminescent oxygen channeling immunoassay (multi‐LOCI) platform by implementation of LOCI with suspension array technology is reported. As the microcarrier of the platform, a unique dual‐functional barcode with a host–guest structure composed of a quantum dot host bead (QDH) and LOCI acceptor beads (ABs) is designed, in which QDH provides function of high coding capacity while ABs facilitate the LOCI function. The analytes bridge QDH@ABs and LOCI donor beads (DBs) into a close proximity, forming a QDH@ABs–DBs “host–guest–satellite” superstructure that generates both barcode signal from QDH and LOCI signal induced by singlet oxygen channeling between ABs and DBs. Through imaging‐based decoding, different barcodes are automatically distinguished and colocalized with LOCI signals. Importantly, the assay achieves simultaneous detection of multiple analytes within one reaction, simply by following a “mix‐and‐measure” protocol without the need for tedious washing steps. Furthermore, the multi‐LOCI platform is validated for real sample measurements. With the advantages of robustness, simplicity, and high multiplexing, the platform holds great potential for the development of point‐of‐care diagnostics.  相似文献   

7.
Porous agarose microbeads, with high surface to volume ratios and high binding densities, are attracting attention as highly sensitive, affordable sensor elements for a variety of high performance bioassays. While such polymer microspheres have been extensively studied and reported on previously and are now moving into real-world clinical practice, very little work has been completed to date to model the convection, diffusion, and binding kinetics of soluble reagents captured within such fibrous networks. Here, we report the development of a three-dimensional computational model and provide the initial evidence for its agreement with experimental outcomes derived from the capture and detection of representative protein and genetic biomolecules in 290 μm porous beads. We compare this model to antibody-mediated capture of C-reactive protein and bovine serum albumin, along with hybridization of oligonucleotide sequences to DNA probes. These results suggest that, due to the porous interior of the agarose bead, internal analyte transport is both diffusion and convection based, and regardless of the nature of analyte, the bead interiors reveal an interesting trickle of convection-driven internal flow. On the basis of this model, the internal to external flow rate ratio is found to be in the range of 1:170 to 1:3100 for beads with agarose concentration ranging from 0.5% to 8% for the sensor ensembles here studied. Further, both model and experimental evidence suggest that binding kinetics strongly affect analyte distribution of captured reagents within the beads. These findings reveal that high association constants create a steep moving boundary in which unbound analytes are held back at the periphery of the bead sensor. Low association constants create a more shallow moving boundary in which unbound analytes diffuse further into the bead before binding. These models agree with experimental evidence and thus serve as a new tool set for the study of bioagent transport processes within a new class of medical microdevices.  相似文献   

8.
Virus detection and analysis are of critical importance in biological fields and medicine. Surface‐enhanced Raman scattering (SERS) has shown great promise in small molecule and even single molecule detection, and can provide fingerprint signals of molecules. Despite the powerful detection capabilities of SERS, the size discrepancy between the SERS “hot spots” (generally, <10 nm) and viruses (usually, sub‐100 nm) yields poor detection reliability of viruses. Inspired by the concept of molecular imprinting, a volume‐enhanced Raman scattering (VERS) substrate composed of hollow nanocones at the bottom of microbowls (HNCMB) is developed. The hollow nanocones of the resulting VERS substrates serve a twofold purpose: 1) extending the region of Raman signal enhancement from the nanocone surface (e.g., surface “hot spots”) to the hollow area within the cone (e.g., volume “hot spots”)—a novel method of Raman signal enhancement, and 2) directing analyte such as viruses of a wide range of sizes to those VERS “hot spots” while simultaneously increasing the surface area contributing to SERS. Using HNCMB VERS substrates, greatly improved Raman signals of single viruses are demonstrated, an achievement with important implications in disease diagnostics and monitoring, biomedical fields, as well as in clinical treatment.  相似文献   

9.
A new flow‐through method for rapid capture and detection of microorganisms is developed using optically‐flat microengineered membranes. Selective and efficient capture of Salmonella is demonstrated with antibodies coated on membranes (microsieves) having a pore size much larger than the microorganism itself. The silicon‐nitride membranes are first photochemically coated with 1,2‐epoxy‐9‐decene yielding stable Si–C and N–C linkages. The resultant epoxide‐terminated microsieves are subsequently biofunctionalized with anti‐Salmonella antibodies. The capture efficiency of antibody‐coated microsieves with different pore sizes (2.0–5.0 μm) is studied with Salmonella enterica enterica serotype Typhimurium suspensions (107 cfu mL–1). The antibody‐coated microsieves capture 52% (2 μm microsieves), 30% (3.5 μm microsieves), and 12% (5 μm microsieves) of Salmonella from the suspension. The influence of flow rate (0.8–16 μL min–1 mm–2) on the capture efficiency of antibody‐coated 3.5 μm microsieves is investigated. The capture efficiency increases from ≈30% to ≈70% when the flow‐rate decreases from 16 to 0.8 μL min–1 mm–2. Antibody‐coated 3.5 μm microsieves can capture Salmonella rapidly and directly from fresh milk suspension (capture 35% at concentration of 80 cfu mL–1). The use of antibody‐coated microsieves as microbial selective capture devices is thus shown to be highly promising for the direct capture of microorganisms.  相似文献   

10.
A novel electrochemical strategy that uses DNA-wrapped carbon nanotubes (CNTs) as electrochemical labels is developed for sensitive and selective detection of sequence-specific DNA. The presence of target DNA mediates the formation of a sandwiched complex between the DNA-wrapped CNT and a hairpin DNA capture probe immobilized on magnetic beads. This allows target-selective collection of the CNT labels by magnetic separation and transfer on the electrode surface modified with an insulating self-assembled monolayer (SAM). After treatment with N,N-dimethylformamide, the collected sandwiched complex releases the bare CNTs and facilitates the removal of magnetic beads from the electrode surface. The bare CNTs can then assemble on the SAM-modified electrode surface and mediate efficient electron transfer between the electrode and the electroactive species in the solution with a strong current signal generated. The results indicate that the developed strategy shows a sensitive response to target DNA with a desirable signal gain and a low detection limit of 0.9 pM. This strategy is also demonstrated to provide excellent differentiation of single-base mismatch in target DNA. It is expected that this electrochemical strategy may hold great potential as a novel platform for clinical diagnostics and genetic analysis.  相似文献   

11.
A sensor technique is described that captures analyte species on a preconcentrating minicolumn containing a selective solid-phase sorbent. In this approach, the sample is pumped through the column until the sorbent phase is fully equilibrated with the sample concentration, and the exit concentration equals the inlet concentration. On-column detection of the captured analytes using radiometric and spectroscopic methods is demonstrated. In trace level detection applications, this sensor provides a steady-state signal that is proportional to sample analyte concentration and is reversible. The method is demonstrated for the detection of Tc-99 using anion-exchange beads mixed with scintillating beads and light detection, Sr-90 using SuperLig 620 beads mixed with scintillating beads and light detection; and hexavalent chromium detection using anion-exchange beads with spectroscopic detection. Theory has been developed to describe the signal at equilibration and to describe analyte uptake as a function of volume and concentration, using parameters and concepts from frontal chromatography. It is shown that experimental sensor behavior closely matches theoretical predictions and that effective sensors can be prepared using low plate number columns. This sensor modality has many desirable characteristics for in situ sensors for trace level contaminant long-term monitoring where the use of consumable reagents for sensor regeneration would be undesirable. Initial experiments in groundwater matrixes demonstrated the detection of Tc-99 at drinking water level standards (activity of 0.033 Bq/mL) and detection of hexavalent chromium to levels below drinking water standards of 50 ppb.  相似文献   

12.
Resistive pulse sensing is used to monitor individual and aggregated rod-shaped nanoparticles as they move through tunable pores in elastomeric membranes. By comparing particles of similar dimensions, it is demonstrated that the resistive pulse signal of a rod is fundamentally different from that of a sphere. Rods can be distinguished using two measurements: the blockade event magnitude (Δi(p) ), which reveals the particle's size, and the full width at half maximum (FWHM) duration, which relates to the particle's speed and length. While the observed Δi(p) values agree well with simulations, the measured FWHM times are much larger than expected. This increase in dwell time, caused by rods moving through the pore in various orientations, is not observed for spherical particles. These differences are exploited in a new agglutination assay using rod-shaped particles. By controlling the surface chemistry and location of the capture ligand, rods are made to form either long "end-on-end" or wide "side-on" aggregates upon the addition of an analyte. This observation will facilitate multiplexed detection in agglutination assays, as particles with a particular aspect ratio can be distinguished by two measurements. This is first demonstrated with a biotinylated target and avidin capture probe, followed by the detection of platelet-derived growth factor (PDGF-BB) using an aptamer capture probe, with limits of detection down to femtomolar levels.  相似文献   

13.
Electronic DNA‐biosensor with a single nucleotide resolution capability is highly desirable for personalized medicine. However, existing DNA‐biosensors, especially single nucleotide polymorphism (SNP) detection systems, have poor sensitivity and specificity and lack real‐time wireless data transmission. DNA‐tweezers with graphene field effect transistor (FET) are used for SNP detection and data are transmitted wirelessly for analysis. Picomolar sensitivity of quantitative SNP detection is achieved by observing changes in Dirac point shift and resistance change. The use of DNA‐tweezers probe with high‐quality graphene FET significantly improves analytical characteristics of SNP detection by enhancing the sensitivity more than 1000‐fold in comparison to previous work. The electrical signal resulting from resistance changes triggered by DNA strand‐displacement and related changes in the DNA geometry is recorded and transmitted remotely to personal electronics. Practical implementation of this enabling technology will provide cheaper, faster, and portable point‐of‐care molecular health status monitoring and diagnostic devices.  相似文献   

14.
Analysis of monosaccharides is typically performed using analytical systems that involve a separation step followed by a detection step. The separation step is usually necessary because of the high degree of structural similarity between different monosaccharides. A novel sensing system for monosaccharides is described here in which living bacteria were designed to detect a model monosaccharide, L-arabinose, without the need for a separation step. In such sensing systems, analytes are detected by employing the selective recognition properties found in certain bacterial proteins. These systems are designed so that a reporter protein is expressed by the bacteria in response to the analyte. The concentration of the analyte can be related to the signal generated by the reporter protein. In the sensing system described here, the green fluorescent protein (GFP) was used as the reporter protein. L-Arabinose concentrations can be determined by monitoring the fluorescence emitted by the bacteria at 509 nm after excitation of GFP at 395 nm. The system can detect L-arabinose at concentrations as low as 5 x 10(-7) M and is selective over D-arabinose, the stereoisomer of the analyte, as well as over a variety of pentose and hexose sugars.  相似文献   

15.
In vivo molecular imaging of tumors targeting a specific cancer cell marker is a promising strategy for cancer diagnosis and imaging guided surgery and therapy. While targeted imaging often relies on antibody‐modified probes, peptides can afford targeting probes with small sizes, high penetrating ability, and rapid excretion. Recently, in vivo fluorescence imaging in the second near‐infrared window (NIR‐II, 1000–1700 nm) shows promise in reaching sub‐centimeter depth with microscale resolution. Here, a novel peptide (named CP) conjugated NIR‐II fluorescent probe is reported for molecular tumor imaging targeting a tumor stem cell biomarker CD133. The click chemistry derived peptide‐dye (CP‐IRT dye) probe afforded efficient in vivo tumor targeting in mice with a high tumor‐to‐normal tissue signal ratio (T/NT > 8). Importantly, the CP‐IRT probes are rapidly renal excreted (≈87% excretion within 6 h), in stark contrast to accumulation in the liver for typical antibody‐dye probes. Further, with NIR‐II emitting CP‐IRT probes, urethra of mice can be imaged fluorescently for the first time noninvasively through intact tissue. The NIR‐II fluorescent, CD133 targeting imaging probes are potentially useful for human use in the clinic for cancer diagnosis and therapy.  相似文献   

16.
The skin of springtails is well‐known for being able to repel water and organic liquids using their hexagonally arranged protrusions with reentrant structures. Here, a method to prepare 100 nm‐sized nanohoodoo arrays with quasi‐doubly reentrant structures over square centimeters through combining the nanosphere lithography and the template‐protected selective reactive ion etching technique is demonstrated. The top size of the nanohoodoos, the intra‐nanohoodoo distance, and the height of the nanohoodoos can be readily controlled by the plasma‐etching time of the polystyrene (PS) spheres, the size of the PS spheres used, and the reactive ion etching time of silicon. The strong structural control capability allows for the study of the relationship between the nanohoodoo structure and the wetting property. Superamphiphobic nanohoodoo arrays with outstanding water/organic liquid repellent properties are finally obtained. The superamphiphobic and liquid repellent properties endow the nanohoodoo arrays with remarkable self‐cleaning performance even using hot water droplets, anti‐fogging performance, and the surface‐enhanced Raman scattering sensitivity improvement by enriching the analyte molecules on the nanohoodoo arrays. Overall, the simple and massive production of the superamphiphobic nanohoodoo structures will push their practical application processes in diverse fields where wettability and liquid repellency need to be carefully engineered.  相似文献   

17.
Magnetic microparticles or “beads” are used in a variety of research applications from cell sorting through to optical force traction microscopy. The magnetic properties of such particles can be tailored for specific applications with the uniformity of individual beads critical to their function. However, the majority of magnetic characterization techniques quantify the magnetic properties from large bead ensembles. Developing new magnetic imaging techniques to evaluate and visualize the magnetic fields from single beads will allow detailed insight into the magnetic uniformity, anisotropy, and alignment of magnetic domains. Here, diamond‐based magnetic microscopy is applied to image and characterize individual magnetic beads with varying magnetic and structural properties: ferromagnetic and superparamagnetic/paramagnetic, shell (coated with magnetic material), and solid (magnetic material dispersed in matrix). The single‐bead magnetic images identify irregularities in the magnetic profiles from individual bead populations. Magnetic simulations account for the varying magnetic profiles and allow to infer the magnetization of individual beads. Additionally, this work shows that the imaging technique can be adapted to achieve illumination‐free tracking of magnetic beads, opening the possibility of tracking cell movements and mechanics in photosensitive contexts.  相似文献   

18.
Long X  Miró M  Hansen EH 《Analytical chemistry》2005,77(18):6032-6040
A new concept is presented for selective and sensitive determination of trace metals via electrothermal atomic absorption spectrometry based on the principle of bead injection (BI) with renewable reversed-phase surfaces in a sequential injection-lab-on-valve (SI-LOV) mode. The methodology involves the use of poly(styrene-divinylbenzene) beads containing pendant octadecyl moieties (C18-PS/DVB), which are preimpregnated with a selective organic metal chelating agent prior to the automatic manipulation of the beads in the microbore conduits of the LOV unit. By adapting this approach, the immobilization of the most suitable chelating agent can be effected irrespective of the kinetics involved, optimal reaction conditions can be used for implementing the chelating reaction of the target metal analyte with the immobilized re-agent, and an added degree of freedom is offered in selecting the most favorable elution mode in order to attain the highest sensitivity. The potential of the SI-BI-LOV scheme is demonstrated by taking Cr(VI) as a model analyte, using a 1,5-diphenylcarbazide (DPC)-loaded bead column as the active microzone. As this reaction requires the use of high acidity, it is also shown that the bead material exhibits excellent chemical stability at low pH values. On-line pH sample adjustment prevents alteration of the original distribution of chromium species while ensuring fast rates for the DPC-Cr(VI) reaction. The proposed procedure was successfully applied to the determination of trace levels of Cr(VI) in natural waters containing high levels of dissolved salts (such as seawater and hard tap water) without requiring any dilution step. Method validation was performed by determination of total chromium in an NIST standard reference material (NIST 1640, natural water) after Cr(III) oxidation, and the results were in good agreement with the certified value.  相似文献   

19.
A clinically relevant magneto‐optical technique (fd‐FRS, frequency‐domain Faraday rotation spectroscopy) for characterizing proteins using antibody‐functionalized magnetic nanoparticles (MNPs) is demonstrated. This technique distinguishes between the Faraday rotation of the solvent, iron oxide core, and functionalization layers of polyethylene glycol polymers (spacer) and model antibody–antigen complexes (anti‐BSA/BSA, bovine serum albumin). A detection sensitivity of ≈10 pg mL?1 and broad detection range of 10 pg mL?1 ? cBSA ? 100 µ g mL?1 are observed. Combining this technique with predictive analyte binding models quantifies (within an order of magnitude) the number of active binding sites on functionalized MNPs. Comparative enzyme‐linked immunosorbent assay (ELISA) studies are conducted, reproducing the manufacturer advertised BSA ELISA detection limits from 1 ng mL?1 ? cBSA ? 500 ng mL?1. In addition to the increased sensitivity, broader detection range, and similar specificity, fd‐FRS can be conducted in less than ≈30 min, compared to ≈4 h with ELISA. Thus, fd‐FRS is shown to be a sensitive optical technique with potential to become an efficient diagnostic in the chemical and biomolecular sciences.  相似文献   

20.
Development of molecular probes holds great promise for early diagnosis of aggressive prostate cancer. Here, 2‐[3‐(1,3‐dicarboxypropyl) ureido] pentanedioic acid (DUPA)‐conjugated ligand and bis‐isoindigo‐based polymer (BTII) are synthesized to formulate semiconducting polymer nanoparticles (BTII‐DUPA SPN) as a prostate‐specific membrane antigen (PSMA)‐targeted probe for prostate cancer imaging in the NIR‐II window. Insights into the interaction of the imaging probes with the biological targets from single cell to whole organ are obtained by transient absorption (TA) microscopy and photoacoustic (PA) tomography. At single‐cell level, TA microscopy reveals the targeting efficiency, kinetics, and specificity of BTII‐DUPA SPN to PSMA‐positive prostate cancer. At organ level, PA tomographic imaging of BTII‐DUPA SPN in the NIR‐II window demonstrates superior imaging depth and contrast. By intravenous administration, BTII‐DUPA SPN demonstrates selective accumulation and retention in the PSMA‐positive tumor, allowing noninvasive PA detection of PSMA overexpressing prostate tumors in vivo. The distribution of nanoparticles inside the tumor tissue is further analyzed through TA microscopy. These results collectively demonstrate BTII‐DUPA SPN as a promising probe for prostate cancer diagnosis by PA tomography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号