首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The real-time uptake of serotonin, a neurotransmitter, by rat leukemia mast cell line RBL-2H3 and 5-hydroxytryptophan by Chinese hamster V79 cells has been studied by fluorescence lifetime imaging microscopy (FLIM), monitoring ultraviolet (340 nm) fluorescence induced by two-photon subpicosecond 630 nm excitation. Comparison with two-photon excitation with 590 nm photons or by three-photon excitation at 740 nm shows that the use of 630 nm excitation provides optimal signal intensity and lowered background from auto-fluorescence of other cellular components. In intact cells, we observe using FLIM three distinct fluorescence lifetimes of serotonin and 5-hydroxytryptophan according to location. The normal fluorescence lifetimes of both serotonin (3.8 ns) and 5-hydroxytryptophan (3.5 ns) in solution are reduced to approximately 2.5 ns immediately on uptake into the cell cytosol. The lifetime of internalized serotonin in RBL-2H3 cells is further reduced to approximately 2.0 ns when stored within secretory vesicles.  相似文献   

2.
We describe the theory and implementation of a frequency‐domain fluorescence lifetime confocal microscope using switched diode laser illumination. Standard, communications‐type, radio‐frequency electronics are used to provide inexpensive modulation references and to perform phase‐sensitive detection. This allows the rapid acquisition of fluorescence intensity and lifetime images and their display in real time. We show fluorescence lifetime images of bead objects and fluorescence lifetime images of biological specimens from a single confocal scan.  相似文献   

3.
We develop a multidimensional fluorescence imaging technique by implementing a wide-field time-gated fluorescence lifetime imaging into digital scanned laser light-sheet microscopy (FLIM-DSLM) to measure 3D fluorescence lifetime distribution in mesoscopic specimens with high resolution. This is achieved by acquiring a series of time-gated images at different relative time delays with respect of excitation pulses at different depths. The lifetime is determined for each voxel by iteratively fitting to single exponential decay. The performance of the developed system is evaluated with the measurements of a lifetime reference Rhodamine 6G solution and a subresolution fluorescent bead phantom. We also demonstrate the application performances of this system to ex vivo and in vivo imaging of Tg(kdrl:EGFP) transgenic zebrafish embryos, illustrating the lifetime differences between the GFP signal and the autofluorescence signal. The results show that FLIM-DSLM can be used for sample size up to a few millimetres and can be utilised as a powerful and robust method for biomedical research, for example as a readout of protein–protein interactions via Förster resonance energy transfer.  相似文献   

4.
A scanning microscope utilizing two-photon excitation in combination with fluorescence lifetime contrast is presented. The microscope makes use of a tunable femtosecond titanium:sapphire laser enabling the two-photon excitation of a broad range of fluorescent molecules, including UV probes. Importantly, the penetration depth of the two-photon exciting (infra)red light is substantially greater than for the corresponding single-photon wavelength while photobleaching is significantly reduced. The time structure of the Ti:Sa laser can be employed in a straightforward way for the realization of fluorescence lifetime imaging. The fluorescence lifetime is sensitive to the local environment of the fluorescent molecule. This behaviour can be used for example to quantify concentrations of ions, such as pH and Ca2+, or pO2 and pCO2. In the set-up presented here the fluorescence lifetime imaging is accomplished by time-gated single photon counting. The performance and optical properties of the microscope are investigated by a number of test measurements on fluorescent test beads. Point-spread functions calculated from measurements on 230-nm beads using an iterative restoration procedure compare well with theoretical expectations. Lifetime imaging experiments on a test target containing two different types of test bead in a fluorescent buffer all with different lifetimes (2.15 ns, 2.56 ns and 3.34 ns) show excellent quantitative agreement with reference values obtained from time correlated single photon counting measurements. Moreover, the standard deviation in the results can be wholly ascribed to the photon statistics. Measurements of acridine orange stained biofilms are presented as an example of the potential of two-photon excitation combined with fluorescence lifetime contrast. Fluorescence lifetime and intensity images were recorded over the whole sample depth of 100 μm. Fluorescence intensity imaging is seriously hampered by the rapid decrease of the fluorescence signal as a function of the depth into the sample. Fluorescence lifetime imaging on the other hand is not affected by the decrease of the fluorescence intensity.  相似文献   

5.
Two-photon fluorescence lifetime imaging microscopy was used noninvasively to monitor a fluorescent antigen during macrophage-mediated endocytosis, intracellular vacuolar encapsulation, and protease-dependent processing. Fluorescein-conjugated bovine serum albumin (FITC–BSA) served as the soluble exogenous antigen. As a relatively nonfluorescent probe in the native state, the antigen was designed to reflect sequential intracellular antigen processing events through time-dependent changes in fluorescence properties. Using two-photon lifetime imaging microscopy, antigen processing events were monitored continuously for several hours. During this time, the initial fluorescein fluorescence lifetime of 0.5 ns increased to α 3.0 ns. Control experiments using fluorescein conjugated poly- l -lysine and poly- d -lysine demonstrated that the increase in fluorescence parameters observed with FITC–BSA were due to intracellular proteolysis since addition of the inert d -isomer did not promote an increase in fluorescence lifetime or intensity. Comparisons of intravacuolar and extracellular FITC–dextran concentration suggested active localization of dextran in the vacuoles by the macrophage. In addition, the kinetics of degradation observed using two-photon microscopy were similar to results obtained on the flow cytometer, thus validating the use of flow cytometry for future studies.  相似文献   

6.
We demonstrate the possibility to increase substantially the number of simultaneously detected fluorophores by utilizing both spectral and lifetime information. Using a two-detector confocal scanning laser microscope, experiments confirm that four different fluorophores can be detected with good channel separation. The signal-to-noise ratio (SNR) of the recorded images is investigated both theoretically and experimentally. It is found that in order to obtain a high SNR fluorophore lifetimes should differ by approximately an order of magnitude.  相似文献   

7.
It is demonstrated that fluorescence lifetimes in the nanosecond and picosecond time-scale range can be observed with the recently proposed double-pulse fluorescence lifetime imaging technique (Müller et al. , 1995, Double-pulse fluorescence lifetime imaging in confocal microscopy. J. Microsc 177, 171–179).
A laser source with an optical parametric amplifier (OPA) system is used to obtain short pulse durations needed for high time resolution, wavelength tunability for selective excitation of specific fluorophores and high pulse energies to obtain (partial) saturation of the optical transition.
It is shown that fluorescence lifetimes can be determined correctly also with nonuniform saturation conditions over the observation area.
A correction scheme for the effect on the measurements of laser power fluctuations, which are inherently present in OPA systems, is presented. Measurements on bulk solutions of Rhodamine B and Rhodamine 6G in different solvents confirm the experimental feasibility of accessing short fluorescence lifetimes with this technique.
Because signal detection does not require fast electronics, the technique can be readily used for fluorescence lifetime imaging in confocal microscopy, especially when using bilateral scanning and cooled CCD detection.  相似文献   

8.
Cheng  Pan  Shih  Kim  Liou  Park 《Journal of microscopy》1998,189(3):199-212
A new generation of efficient two-photon absorbing fluorescent molecules has been developed and used effectively for two-photon laser scanning microscopy. Several examples of the use of these new fluorophores have been presented. In addition, issues relating to the two-photon absorption cross-section, excitation power, sample properties and resolution in two-photon laser scanning microscopy are discussed.  相似文献   

9.
Three-dimensional confocal imaging of polymer samples was achieved by the use of two-photon excited fluorescence in both positive and negative contrast modes. The fluorophore was a new and highly efficient two-photon induced upconverter, resulting in improved signal strength at low pumping power. Because of the relatively long wavelength of the excitation source (798 nm from a mode-locked Ti:Sap-phire laser), this technique shows a larger penetration depth into the samples than provided by conventional single-photon fluorescence confocal microscopy. Single-photon and two-photon images of the same area of each sample show significant differences. The results suggest the possibility of using two-photon confocal microscopy, in conjunction with highly efficient fluorophores, as a tool to study the surface, interface, and fracture in material science applications.  相似文献   

10.
Multiple frequency fluorescence lifetime imaging microscopy   总被引:3,自引:0,他引:3  
The experimental configuration and the computational algorithms for performing multiple frequency fluorescence lifetime imaging microscopy (mfFLIM) are described. The mfFLIM experimental set‐up enables the simultaneous homodyne detection of fluorescence emission modulated at a set of harmonic frequencies. This was achieved in practice by using monochromatic laser light as an excitation source modulated at a harmonic set of frequencies. A minimum of four frequencies were obtained by the use of two standing wave acousto‐optic modulators placed in series. Homodyne detection at each of these frequencies was performed simultaneously by mixing with matching harmonics present in the gain characteristics of a microchannel plate (MCP) image intensifier. These harmonics arise as a natural consequence of applying a high frequency sinusoidal voltage to the photocathode of the device, which switches the flow of photoelectrons ‘on’ and ‘off’ as the sinus voltage swings from negative to positive. By changing the bias of the sinus it was possible to control the duration of the ‘on’ state of the intensifier relative to its ‘off’ state, enabling the amplitude of the higher harmonic content in the gain to be controlled. Relative modulation depths of 400% are theoretically possible from this form of square‐pulse modulation. A phase‐dependent integrated image is formed by the sum of the mixed frequencies on the phosphor of the MCP. Sampling this signal over a full period of the fundamental harmonic enables each harmonic to be resolved, provided that the Nyquist sampling criterion is satisfied for the highest harmonic component in the signal. At each frequency both the phase and modulation parameters can be estimated from a Fourier analysis of the data. These parameters enable the fractional populations and fluorescence lifetimes of individual components of a complex fluorescence decay to be resolved on a pixel‐by‐pixel basis using a non‐linear fit to the dispersion relationships. The fitting algorithms were tested on a simulated data set and were successful in disentangling two populations having 1 ns and 4 ns fluorescence lifetimes. Spatial invariance of the lifetimes was exploited to improve the accuracy significantly. Multiple frequency fluorescence lifetime imaging microscopy was then successfully applied to resolve the fluorescence lifetimes and fluorescence intensity contributions in a rhodamine dye mixture in solution, and green fluorescent protein variants co‐expressed in live cells.  相似文献   

11.
In the femtoliter observation volume of a two-photon microscope, multiple fluorophores can be present and complex photophysics can take place. Combined detection of the fluorescence emission spectra and lifetimes can provide deeper insight into specimen properties than these two imaging modalities taken separately. Therefore, we have developed a detection scheme based on a frequency-modulated multichannel photomultiplier, which measures simultaneously the spectrum and the lifetime of the emitted fluorescence. Experimentally, the efficiency of the frequency domain lifetime measurement was compared to a time domain set-up. The performance of this spectrally and lifetime-resolved microscope was evaluated on reference specimens and living cells labeled with three different stains targeting the membrane, the mitochondria, and the nucleus.  相似文献   

12.
A theoretical analysis of a new technique for fluorescence lifetime measurement, relying on (near steady state) excitation with short optical pulses, is presented. Application of the technique to confocal microscopy enables local determination of the fluorescence lifetime, which is a parameter sensitive to the local environment of fluorescent probe molecules in biological samples. The novel technique provides high time resolution, since it relies on the laser pulse duration, rather than on electronic gating techniques, and permits, in combination with bilateral confocal microscopy and the use of a (cooled) CCD, sensitive signal detection over a large dynamic range. The principle of the technique is discussed within a theoretical framework. The sensitivity of the technique is analysed, taking into account: photodegradation, the effect of the laser repetition rate and the effect of non-steady-state excitation. The features of the technique are compared to more conventional methods for fluorescence lifetime determination.  相似文献   

13.
Optimal resolution by stimulated emission depletion (STED) microscopy requires precise alignment of the donut‐shaped depletion focus to the excitation focus. In this article, we demonstrate that fluorescence lifetime distribution can be implemented to align the STED system. Different from the traditional aligning methods in which a scattering imaging module is often equipped, the lifetime‐based method is free from probable mismatches between the scattering mode and the fluorescent mode, drift errors caused by separate imaging and complex fitting methods. Based on this method, a spatial resolution of 38 nm by time‐gated detection has been achieved. Microsc. Res. Tech. 77:935–940, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

14.
The imaging performance in single-photon (1-p) and two-photon (2-p) fluorescence microscopy is described. Both confocal and conventional systems are compared in terms of the three-dimensional (3-D) point spread function and the 3-D optical transfer function. Images of fluorescent sharp edges and layers are modelled, giving resolution in transverse and axial directions. A comparison of the imaging properties is also given for a 4Pi confocal system. Confocal 2-p 4Pi fluorescence microscopy gives the best axial resolution in the sense that its 3-D optical transfer function has the strongest response along the axial direction.  相似文献   

15.
We demonstrate the potential of fluorescence lifetime imaging by time-correlated single-photon counting as a method for monitoring the transdermal diffusion pathway and diffusion rate of pharmaceuticals in human skin. The current application relies on observing subtle changes in the fluorescence lifetime of the intrinsic fluorophores present in the intracellular region between corneocytes of the stratum corneum. We have comprehensively characterized the measured fluorescence lifetimes from intracorneocyte junctions in three skin section types (dermatomed skin, epidermal membranes and stratum corneum) revealing statistically significant differences of the short lifetime component between each of the types, which we attribute to the sample preparation and imaging method. We show using epidermal membrane sections that application of a drug/solvent formulation consisting of ethinyl estradiol and spectroscopic grade ethanol to the surface gives rise to a slight but statistically significant shortening of the fluorescence lifetime of the long-lived emitting species present in the sample, from approximately 2.8 ns to 2.5 ns. The method may be useful for future studies where the kinetics and pathways of a variety of applied formulations could be investigated.  相似文献   

16.
Inspired by a multiresolution community detection based network segmentation method, we suggest an automatic method for segmenting fluorescence lifetime (FLT) imaging microscopy (FLIM) images of cells in a first pilot investigation on two selected images. The image processing problem is framed as identifying segments with respective average FLTs against the background in FLIM images. The proposed method segments a FLIM image for a given resolution of the network defined using image pixels as the nodes and similarity between the FLTs of the pixels as the edges. In the resulting segmentation, low network resolution leads to larger segments, and high network resolution leads to smaller segments. Furthermore, using the proposed method, the mean‐square error in estimating the FLT segments in a FLIM image was found to consistently decrease with increasing resolution of the corresponding network. The multiresolution community detection method appeared to perform better than a popular spectral clustering‐based method in performing FLIM image segmentation. At high resolution, the spectral segmentation method introduced noisy segments in its output, and it was unable to achieve a consistent decrease in mean‐square error with increasing resolution.  相似文献   

17.
In this work, we proposed and built a multimodal optical setup that extends a commercially available confocal microscope (Olympus VF300) to include nonlinear second harmonic generation (SHG) and third harmonic generation (THG) optical (NLO) microscopy and fluorescence lifetime imaging microscopy (FLIM). We explored all the flexibility offered by this commercial confocal microscope to include the nonlinear microscopy capabilities. The setup allows image acquisition with confocal, brightfield, NLO/multiphoton and FLIM imaging. Simultaneously, two‐photon excited fluorescence (TPEF) and SHG are well established in the biomedical imaging area, because one can use the same ultrafast laser and detectors set to acquire both signals simultaneously. Because the integration with FLIM requires a separated modulus, there are fewer reports of TPEF+SHG+FLIM in the literature. The lack of reports of a TPEF+SHG+THG+FLIM system is mainly due to difficulties with THG because the present NLO laser sources generate THG in an UV wavelength range incompatible with microscope optics. In this article, we report the development of an easy‐to‐operate platform capable to perform two‐photon fluorescence (TPFE), SHG, THG, and FLIM using a single 80 MHz femtosecond Ti:sapphire laser source. We described the modifications over the confocal system necessary to implement this integration and verified the presence of SHG and THG signals by several physical evidences. Finally, we demonstrated the use of this integrated system by acquiring images of vegetables and epithelial cancer biological samples. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

18.
Fluorescence lifetime imaging (FLIM) is a powerful microscopy technique for providing contrast of biological and other systems by differences in molecular species or their environments. However, the cost of equipment and the complexity of data analysis have limited the application of FLIM. We present a mathematical model and physical implementation for a low cost digital frequency domain FLIM (DFD-FLIM) system, which can provide lifetime resolution with quality comparable to time-correlated single photon counting methods. Our implementation provides data natively in the form of phasors. On the basis of the mathematical model, we present an error analysis that shows the precise parameters for maximizing the quality of lifetime acquisition, as well as data to support this conclusion. The hardware and software of the proposed DFD-FLIM method simplifies the process of data acquisition for FLIM, presents a new interface for data display and interpretation, and optimizes the accuracy of lifetime determination.  相似文献   

19.
Ulrich V  Fischer P  Riemann I  Königt K 《Scanning》2004,26(5):217-225
An inverted fluorescence microscope was upgraded into a compact three-dimensional laser scanning microscope (LSM) of 65 x 62 x 48 cm dimensions by means of a fast kHz galvoscanner unit, a piezodriven z-stage, and a picosecond (ps) 50 MHz laser diode at 405 nm. In addition, compact turn-key near infrared femtosecond lasers have been employed to perform multiphoton fluorescence and second harmonic generation (SHG) microscopy. To expand the features of the compact LSM, a time-correlated single photon counting unit as well as a Sagnac interferometer have been added to realize fluorescence lifetime imaging (FLIM) and spectral imaging. Using this unique five-dimensional microscope, TauMap, single-photon excited (SPE), and two-photon excited (TPE) cellular fluorescence as well as intratissue autofluorescence of water plant leaves have been investigated with submicron spatial resolution, <270 ps temporal resolution, and 10 nm spectral resolution.  相似文献   

20.
Wang C  Qiao L  He F  Cheng Y  Xu Z 《Journal of microscopy》2011,243(2):179-183
We experimentally demonstrate, for the first time to the best of our knowledge, two-photon fluorescence imaging with a femtosecond optical parametric amplifier. In particular, we systematically compare the imaging depths of two-photon fluorescence microscopes based on three different excitation sources, including a femtosecond oscillator, a femtosecond regenerative amplifier and the optical parametric amplifier. The results show that the optical parametric amplifier can greatly extend the penetration depth by approximately 227% as compared with that obtained with the femtosecond oscillator due to effective suppression of scattering at longer wavelength and enhanced excitation efficiency enabled by higher pulse energy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号