首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Application of mass spectrometry imaging (MS imaging) analysis to single cells was so far restricted either by spatial resolution in the case of matrix-assisted laser desorption/ionization (MALDI) or by mass resolution/mass range in the case of secondary ion mass spectrometry (SIMS). In this study we demonstrate for the first time the combination of high spatial resolution (7 μm pixel), high mass accuracy (<3 ppm rms), and high mass resolution (R = 100?000 at m/z = 200) in the same MS imaging measurement of single cells. HeLa cells were grown directly on indium tin oxide (ITO) coated glass slides. A dedicated sample preparation protocol was developed including fixation with glutaraldehyde and matrix coating with a pneumatic spraying device. Mass spectrometry imaging measurements with 7 μm pixel size were performed with a high resolution atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) imaging source attached to an Exactive Orbitrap mass spectrometer. Selected ion images were generated with a bin width of Δm/z = ±0.005. Selected ion images and optical fluorescence images of HeLa cells showed excellent correlation. Examples demonstrate that a lower mass resolution and a lower spatial resolution would result in a significant loss of information. High mass accuracy measurements of better than 3 ppm (root-mean-square) under imaging conditions provide confident identification of imaged compounds. Numerous compounds including small metabolites such as adenine, guanine, and cholesterol as well as different lipid classes such as phosphatidylcholine, sphingomyelin, diglycerides, and triglycerides were detected and identified based on a mass spectrum acquired from an individual spot of 7 μm in diameter. These measurements provide molecularly specific images of larger metabolites (phospholipids) in native single cells. The developed method can be used for a wide range of detailed investigations of metabolic changes in single cells.  相似文献   

2.
A novel ionization source for biological mass spectrometry is described that combines atmospheric pressure (AP) ionization and matrix-assisted laser desorption/ionization (MALDI). The transfer of the ions from the atmospheric pressure ionization region to the high vacuum is pneumatically assisted (PA) by a stream of nitrogen, hence the acronym PA-AP MALDI. PA-AP MALDI is readily interchangeable with electrospray ionization on an orthogonal acceleration time-of-flight (oaTOF) mass spectrometer. Sample preparation is identical to that for conventional vacuum MALDI and uses the same matrix compounds, such as alpha-cyano-4-hydroxycinnamic acid. The performance of this ion source on the oaTOF mass spectrometer is compared with that of conventional vacuum MALDI-TOF for the analysis of peptides. PA-AP MALDI can detect low femtomole amounts of peptides in mixtures with good signal-to-noise ratio and with less discrimination for the detection of individual peptides in a protein digest. Peptide ions produced by this method generally exhibit no metastable fragmentation, whereas an oligosaccharide ionized by PA-AP MALDI shows several structurally diagnostic fragment ions. Total sample consumption is higher for PA-AP MALDI than for vacuum MALDI, as the transfer of ions into the vacuum system is relatively inefficient. This ionization method is able to produce protonated molecular ions for small proteins such as insulin, but these tend to form clusters with the matrix material. Limitations of the oaTOF mass spectrometer for singly charged high-mass ions make it difficult to evaluate the ionization of larger proteins.  相似文献   

3.
Room-temperature ionic liquids are useful as solvents for organic synthesis, electrochemical studies, and separations. We wished to examine whether their high solubalizing power, negligible vapor pressure, and broad liquid temperature range are advantageous if they are used as matrixes for UV-MALDI. Several different ionic matrixes were synthesized and tested, using peptides, proteins, and poly(ethylene glycol) (PEG-2000). All ionic liquids tested have excellent solubilizing properties and vacuum stability compared to other commonly used liquid and solid matrixes. However, they varied widely in their ability to produce analyte gas-phase ions. Certain ionic matrixes, however, produce homogeneous solutions of greater vacuum stability, higher ion peak intensity, and equivalent or lower detection limits than currently used solid matrixes. Clearly, ionic liquids and their more amorphous solid analogues merit further investigation as MALDI matrixes.  相似文献   

4.
A rapid, simple, and reliable gender determination of human DNA samples was successfully obtained using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Detection sensitivity reached 0.01 ng or less for DNA samples.  相似文献   

5.
The significance and epidemiological effects of metals to life necessitate the development of direct, efficient, and rapid method of analysis. Taking advantage of its simple, fast, and high-throughput features, we present a novel approach to metal ion detection by matrix-functionalized magnetic nanoparticle (matrix@MNP)-assisted MALDI-MS. Utilizing 21 biologically and environmentally relevant metal ion solutions, the performance of core and matrix@MNP against conventional matrixes in MALDI-MS and laser desorption ionization (LDI) MS were systemically tested to evaluate the versatility of matrix@MNP as ionization element. The matrix@MNPs provided 20- to >100-fold enhancement on detection sensitivity of metal ions and unambiguous identification through characteristic isotope patterns and accurate mass (<5 ppm), which may be attributed to its multifunctional role as metal chelator, preconcentrator, absorber, and reservoir of energy. Together with the comparison on the ionization behaviors of various metals having different ionization potentials (IP), we formulated a metal ionization mechanism model, alluding to the role of exciton pooling in matrix@MNP-assisted MALDI-MS. Moreover, the detection of Cu in spiked tap water demonstrated the practicability of this new approach as an efficient and direct alternative tool for fast, sensitive, and accurate determination of trace metal ions in real samples.  相似文献   

6.
A novel matrix application protocol for direct tissue mass spectrometry is presented. Matrix-assisted laser desorption/ionization is a popular ionization procedure for direct tissue analysis and imaging mass spectrometry. Usually, matrixes are applied by dispensing droplets through either pipettes or automated dispensing machines, or by airbrushing. These techniques are very simple, but it was difficult to obtain uniform matrix crystals on the tissue surface, and nonuniform crystals degrade the spectrum qualities. Here we report a new matrix application protocol, which is a combination of spraying and dispensing droplets, and we have succeeded in overcoming these problems in conventional matrix applications on tissue surfaces. We call our new technique the "spray-droplet method". In this technique, tiny matrix crystals formed by spraying act as seeds for crystal growth. Our technique leads to matrix spots that are filled homogeneously with minute crystals. Such matrix crystals dramatically improve peak intensity and signal-to-noise ratio. In an example on a rat brain section, the number of detectable peaks was increased and signal intensity of m/z 5440 in our method was approximately 30.6 times higher than that in conventional methods. We used this spray-droplet method with a chemical ink-jet technology for matrix deposition to succeed in MALDI imaging of signals, which were undetectable from the conventional matrix applications.  相似文献   

7.
Many different laboratories are currently developing mass-spectrometric techniques to analyze and identify microorganisms. However, minimal work has been done with mixtures of bacteria. To demonstrate that microbial mixtures could be analyzed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), mixed bacterial cultures were analyzed in a double-blind fashion. Nine different bacterial species currently in our MALDI-MS fingerprint library were used to generate 50 different simulated mixed bacterial cultures similar to that done for an initial blind study previously reported (Jarman, K. H.; Cebula, S. T.; Saenz, A. J.; Petersen, C. E.; Valentine, N. B.; Kingsley, M. T.; Wahl, K. L. Anal. Chem. 2000, 72, 1217-1223). The samples were analyzed by MALDI-MS with automated data extraction and analysis algorithms developed in our laboratory. The components present in the sample were identified correctly to the species level in all but one of the samples. However, correctly eliminating closely related organisms was challenging for the current algorithms, especially in differentiating Serratia marcescens, Escherichia coli, and Yersinia enterocolitica, which have some similarities in their MALDI-MS fingerprints. Efforts to improve the specificity of the algorithms are in progress.  相似文献   

8.
Cai Y  Jiang Y  Cole RB 《Analytical chemistry》2003,75(7):1638-1644
The formation and decomposition (postsource decay, PSD) of anionic adducts in negative ion matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry have been studied. Chloride, a small inorganic anion, has been found to form stable anionic adducts with a variety of neutral oligosaccharides that can survive the MALDI process to give readily identifiable signals (with characteristic isotope patterns) allowing subpicomole detection in the best cases. The matrixes that can aid the formation of chloride adducts of oligosaccharides have gas-phase acidities lower than or close to that of HCl (1373 kJ/mol). In PSD experiments, precursor chloride adducts of oligosaccharides yield fragment ions that retain the charge on the sugar molecule rather than solely forming Cl-, and these fragments can provide structurally informative product ions. In negative ion MALDI, highly acidic oligosaccharides do not form adducts with chloride anions, but mildly acidic saccharides (e.g., containing a carboxylic acid group) form both deprotonated molecules and chloride adducts, and each may provide structural information concerning the oligosaccharide upon decomposition.  相似文献   

9.
D(4)-α-Cyano-4-hydroxycinnamic acid (D(4)-CHCA) has been synthesized for use as a matrix for matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) and MALDI-MS imaging (MSI) of small molecule drugs and endogenous compounds. MALDI-MS analysis of small molecules has historically been hindered by interference from matrix ion clusters and fragment peaks that mask signals of low molecular weight compounds of interest. By using D(4)-CHCA, the cluster and fragment peaks of CHCA, the most common matrix for analysis of small molecules, are shifted by + 4, + 8 and + 12 Da, which expose signals across areas of the previously concealed low mass range. Here, obscured MALDI-MS signals of a synthetic small molecule pharmaceutical, a naturally occurring isoquinoline alkaloid, and endogenous compounds including the neurotransmitter acetylcholine have been unmasked and imaged directly from biological tissue sections.  相似文献   

10.
Automation of data collection in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry using a correlative analysis algorithm is demonstrated. This algorithm was employed to compensate for mass spectral jittering in MALDI data collection (e.g., peak shifts along the m/z axis, signal intensity deviations, etc.). Several important parameters for performing correlative analysis, such as the minimum correlation coefficient to be used and number of mass spectra to acquire prior to correlation, have been investigated and optimized. In addition, the correlation algorithm improved mass resolution of low- and high-molecular-weight compounds by as much as a factor of 4. Signal reproducibility in MALDI quantitative analysis also is improved when correlation is employed for data collection. This data collection algorithm can be used in conjunction with other instrumental optimization programs to allow for fully automated MALDI analysis, which is required for the routine applications carried out in many analytical laboratories.  相似文献   

11.
The aim of this contribution is the application of matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI) in the area of photolithographic structuring. As proof of concept, this method was used to image an UV exposed negative photoresist layer, which is generally used to manufacture printed circuit boards (PCB) for electronic components. The negative photoresist layer consisting of the main component novolac, benzophenone as the active component, and the solvent tetrahydrofuran was mixed with the matrix dithranol and the salt additive LiTFA and spin-coated onto an ITO-conductive glass slide. To imprint an image on the created surface, a transparency with a printed wiring diagram was placed on top of it and irradiated by UV light for 15 min. The inspection of the efficient imprinting of the microstructure onto the photoresist layer was performed by MALDI-MSI. This unique application represents a further step toward the surface analysis of polymer films by this emerging life science imaging technique.  相似文献   

12.
Chen H  He M  Pei J  He H 《Analytical chemistry》2003,75(23):6531-6535
Quantitative analyses of synthetic polymers were accomplished using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). Many factors have hindered the development of quantitative measurement of polymers via MALDI TOF MS, e.g., laser power, matrix, cation salt, and cocrystallization. By probing the optimal conditions, two sets of polymers were studied. Fair repeatability of the samples ensures acceptable results. In set 1, two poly(ethylene glycols) with different end groups showed equal desorption/ionization efficiencies. Two synthetic polymers in set 2 with different chemical properties resulted in different MALDI responses. Good linearity was achieved by plotting the relationship between the sample concentration ratio and the total signal intensity ratio in both sets.  相似文献   

13.
The implantation of low-velocity massive gold clusters is shown to be a method of choice for homogeneous incorporation of a metallic matrix into the near-surface region of a solid biopolymer for subsequent laser desorption/ionization (LDI) MS analysis. Matrix implanted (MI)LDI spectra from cluster-implanted pure test peptide or tissue exhibit molecular ion peaks similar to those observed by matrix-assisted LDI. Moreover, the ion emission is very reproducible from any spot on the surface of these test samples. MILDI promises to be a powerful technique for mass spectrometric analysis of native biological samples as demonstrated by the first results on rat brain tissues.  相似文献   

14.
Current methods for the identification of mycobacteria in culture are time-consuming, requiring as long as 12 weeks for positive identification. One potential approach to rapid mycobacterial identification is to utilize proteomic profiling of cultures by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). In this report, we have applied MALDI-TOF MS to proteomic profiling of cultured microorganisms representing six species of the genus Mycobacterium. We find that analysis of acetonitrile/trifluoroacetic acid cellular extracts produces data similar to that of the analysis of deposited whole cells, while minimizing human contact with the microorganisms and rendering them nonviable. A matrix composition of alpha-cyano-4-hydroxycinnamic acid with fructose yields highly reproducible MALDI-TOF spectra. Statistical analysis of MALDI-TOF MS data allows differentiation of each individual mycobacterial species on the basis of unique mass fingerprints. The methodology allows identification of a number of unique (potentially diagnostic) biomarkers as targets for protein identification by MS/MS experiments. In addition, we observe a number of signals common to all mycobacterial species studied by MALDI-TOF MS, which may be genus-specific biomarkers. The potentially genus-specific biomarkers occur at low mass (<2 kDa) and are likely to be lipids and cell wall components such as mycolic acids. This study demonstrates the potential for mass spectrometry-based identification/classification of mycobacteria.  相似文献   

15.
The analysis of hydrophobic and hydrophilic peptides in an aqueous medium using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. The key development allowing for simultaneous analysis of both hydrophobic and hydrophilic components of the sample mixture is the use of surfactants to solubilize the hydrophobic components in the MALDI matrix solution. A wide variety of anionic, cationic, zwitterionic, and nonionic surfactants were evaluated for their ability to assist in the generation of an abundant pseudomolecular ion from a model hydrophobic peptide ([tert-butoxycarbonyl]Glu[gamma-O-benzyl]-Ala-Leu-Ala[O-phenacyl ester]). The results indicate that the most successful surfactant among those studied for analyzing the model hydrophobic peptide is sodium dodecyl sulfate (SDS). SDS exhibited no interfering surfactant background ions, little to no loss of the acid-labile protecting groups from the model hydrophobic peptide, and an abundant pseudomolecular ion of the analyte. In addition, the use of surfactants is shown to be compatible with hydrophilic peptides as well. Mixtures of hydrophobic and hydrophilic peptides were characterized using surfactant-aided (SA) MALDI-MS, and it is demonstrated that all components are detectable once the surfactant is included in the sample solution. We conclude that the key benefit of using SA-MALDI-MS is its ability to simultaneously analyze hydrophobic and hydrophilic peptides from a single sample mixture, including synthetic peptides containing acid- and base-labile protecting groups.  相似文献   

16.
Schaaff TG 《Analytical chemistry》2004,76(21):6187-6196
Positive and negative ions generated by laser-based ionization methods from three gold:thiolate cluster compounds are mass analyzed by time-of-flight mass spectrometry. The three compounds have similar inorganic core masses ( approximately 29 kDa, approximately 145 Au atoms) but different n-alkanethiolate ligands associated with each cluster compound (Au:SR, R = butane, hexane, dodecane). Irradiation of neat films (laser desorption/ionization) and films generated by dilution of the cluster compounds in an organic acid matrix (matrix-assisted laser desorption/ionization) with a nitrogen laser (337 nm) produced distinct ion abundances that are relevant to different structural aspects of the cluster compound. Laser desorption/ionization of neat Au:SR compound films produces ions consistent with the inorganic core mass (i.e., devoid of original hydrocarbon content). Matrix-assisted laser desorption/ionization produces either ions with m/z values consistent with the core mass of the cluster compounds or ions with m/z values consistent with the approximate molecular weight of the cluster compounds, depending on ionization conditions. The ion abundances, and ionization conditions under which they are detected, provide insight into desorption/ionization processes for these unique cluster compounds as well as other analytes typically studied by matrix-assisted laser desorption/ionization.  相似文献   

17.
Peptides containing the tripeptide sequence Arg-Gly-Asp (RGD) have the ability to bind to members of the integrin superfamily of cell-surface receptors and direct cellular adhesion and haptotaxis. The goal of this work is the development of a rapid and effective method for the quantitative submonolayer spatial composition mapping of surfaces displaying molecular assemblies of RGD-containing organomercaptan peptides on a Au surface using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-MS). Quantitation of the RGD peptide is achieved by determining the peak intensity of the protonated molecular ion, (M + H)+, relative to the (M + H)+ peak for an internal standard, which is similar chemically but with glutamic acid (E) substituted for aspartic acid (D). Using optimized sample preparation procedures, a bilinear calibration was obtained between the quantitative peak intensity ratio and the mole fraction of the RGD-containing peptide. Quantitative compositions were determined with relative standard deviations of <10%, even in the presence of 10x spot-to-spot variations in the absolute signal intensities, by using this internal standard approach. This MALDI-MS quantitative analysis method was employed to probe variable-width two-component counterpropagating electrochemically generated gradients of the two peptides, prepared by coupling in-plane electrochemical potential gradients with the electrosorption reactions of organothiols to vary the composition laterally. The measured lateral composition profiles match the quasi-linear potential gradient model and yield profiles that overlap to a high degree of fidelity in potential space. Thus, MALDI-MS spatial composition mapping should become a powerful tool for the preparation of designed surfaces facilitating the study of cellular adhesion and motility and cell-cell interactions.  相似文献   

18.
Ng KM  Liang Z  Lu W  Tang HW  Zhao Z  Che CM  Cheng YC 《Analytical chemistry》2007,79(7):2745-2755
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was developed for spatial profiling of phytochemicals and secondary metabolites in integrated herbal tissue without solvent extraction. Abundant alkaloid ions, including (+)-menisperine (m/z 356), magnoflorine (m/z 342), stepharanine (m/z 324), protonated sinomenine (m/z 330), protonated sinomendine (m/z 338), and a metabolite at m/z 314, could be directly desorbed from alpha-cyano-4-hydroxycinnamic acid- (CHCA-) coated stem tissue of Sinomenium acutum upon N2 laser (337 nm) ablation, while the ion signals desorbed from sinapinic acid- (SA-) coated and 2,5-dihydroxybenzoic acid- (DHB-) coated stem tissue were at least 10 times weaker. Solvent composition in the matrix solution could have significant effects on the ion intensity of the metabolites. Under optimized conditions that maximize the ion intensity and form homogeneous matrix crystals on the tissue surface, spatial distributions of the metabolites localized in different tissue regions, including cortex, phloem, xylem, rim, and pith, and their relative abundances could be semiquantitatively determined. The three metabolites detected at m/z 356, 342, and 314 showed specific distributions in the herbal samples collected from different growing areas, while others were not. By applying principal component analysis (PCA), the characteristic metabolites in specific tissue regions could be easily determined, allowing unambiguous differentiation of the herbal samples from different geographic locations.  相似文献   

19.
A new high-pressure matrix-assisted laser desorption/ionization (HP-MALDI) source for FTMS has recently been described (O'Connor et al. J. Am. Soc. Mass Spectrom., in press). Improvements to the source design, including the incorporation of a new high-pressure gas channel plate, resulted in ions devoid of metastable fragmentation and also in increased sensitivity compared to the HP-MALDI prototype source design. The focus of this contribution is the evaluation of the current HP-MALDI FTMS configuration. The use of nonconductive sample surfaces, such as Parafilm and Teflon, was explored, and spectra from 30 amol of peptide applied to these surfaces were routinely obtained. In addition, the current limit of detection for this configuration is demonstrated to be 300 zmol for the phosphopeptide RRREEE(pS)EEEAA using multishot accumulation of the ions from 15 laser shots in the hexapole and 1 scan. In addition, the performance of the new HP-MALDI FTMS configuration and its potential application for high-throughput proteomics analyses are discussed.  相似文献   

20.
Microcystins (MCs) are a growing problem in drinking water supplies worldwide. Common analytical techniques used to determine MC concentrations have several shortcomings, including extensive sample handling and lengthy analysis times. A simple, rapid method for quantitation of MCs by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented. Four potential internal standards were tested, including an 15N-labeled MC. For MC-LR in mixed standard solutions, a linear range of 0.11-5.0 microM (R2 = 0.98) was achieved, with a method detection limit (MDL) of 0.015 microM. Matrix effects due to extracted cell components decreased the MC-LR linear range slightly to 0.19-5.0 microM (R2 = 0.99), with MDL = 0.058 microM. Extensive analysis of possible internal standards indicates that nodularin was preferred over [15N]10-microcystin-YR or angiotensin I. The ionization efficiency and analyte-analyte suppression for four MCs of varying polarity are presented; the three polar congeners exhibited good ionization efficiency and acceptable levels of analyte-analyte suppression. These results indicate that MALDI-TOF MS represents a viable alternative for the quantitative measurement of MCs in field samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号