共查询到20条相似文献,搜索用时 15 毫秒
1.
Non-steady state simulation of BOM removal in drinking water biofilters: applications and full-scale validation 总被引:2,自引:0,他引:2
A biofilter model called "BIOFILT" was used to simulate the removal of biodegradable organic matter (BOM) in full-scale biofilters subjected to a wide range of operating conditions. Parameters that were varied included BOM composition, water temperature (3.0-22.5 degrees C), and biomass removal during backwashing (0-100%). Results from biofilter simulations suggest a strong dependence of BOM removal on BOM composition. BOM with a greater diffusivity or with faster degradation kinetics was removed to a greater extent and also contributed to shorter biofilter start-up times. In addition, in simulations involving mixtures of BOM (i.e. readily degradable and slowly degradable components), the presence of readily degradable substrate significantly enhanced the removal of slowly degradable material primarily due to the ability to maintain greater biomass levels in the biofilters. Declines in pseudo-steady state BOM removal were observed as temperature was decreased from 22.5 to 3 degrees C and the magnitude of the change was significantly affected by BOM composition. However, significant removals of BOM are possible at low temperatures (3-6 degrees C). Concerning the impact of backwashing on biofilter performance, BOM removal was not affected by backwash resulting in biomass removals of 60% or less. This suggests that periodic backwashing should not significantly impact biofilter performance as observed biomass removals from full-scale biofilters were negligible. In general, the simulation results were in good qualitative and quantitative agreement with experimental results obtained from full-scale biofilters. 相似文献
2.
Tetrazolium reduction assays, phospholipid analysis, and 16S rRNA (rDNA) sequence analysis were applied to assess the distribution, composition and activity of microbial communities developing in biofilters treating non-ozonated and ozonated drinking water. The response of media-attached biomass to both operating temperature (3 degrees C vs. > 12 degrees C) and ozone application point was assessed. As judged by 2-(p-iodo-phenyl)-3-(p-nitrophenyl)-s-phenyl tetrazolium chloride (INT) reduction, the dehydrogenase activity in biofilter systems that were operated with non-ozonated water was 55% lower than in identical filters operating with ozonated water. There was no significant difference between the microbiological activity measured in a biofilter series treating ozonated water and an identical series where ozonated water was introduced at an intermediate point. The biomass levels in biofilter systems that were operated with ozonated water were 47% higher on average than identical systems operated with non-ozonated water. Operating temperature had no significant impact on total biomass levels; however, specific dehydrogenase activity was 70% higher in systems operated at ambient temperatures (> 12 degrees C) than in systems held at 3 degrees C. Phospholipid and rDNA analysis suggests that there was a community structure response to ozone application and operating temperature, but no response to different ozone application points. 相似文献
3.
Measurement of biomass activity in drinking water biofilters using a respirometric method 总被引:18,自引:0,他引:18
A simple respirometric method was developed and applied for the measurement of biomass activity in bench-scale drinking water biofilters. The results obtained with the new method, i.e. biomass respiration potential (BRP), indicated a high sensitivity allowing the quantification of the activity of low amounts of biomass. The analysis of duplicate samples showed a reasonable reproducibility, i.e. average coefficient of variation of 14% (n = 19). The calculation of the ratio between biomass activity and the amount of viable biomass (phospholipid) at different filter depths indicated a substantial increase of this ratio with filter depth. This indicated an increased biomass activity per unit amount of viable biomass deeper in the biofilters, where biofilm thickness is low. The comparison of the filter profiles of biomass activity and dissolved biodegradable organic matter (BOM), expressed as theoretical oxygen demand, showed a high correlation between these profiles. Consequently, BRP results appear to be good indicators of the BOM removal capacity of the filter biomass. Therefore, BRP results can potentially be used in certain cases instead of BOM measurements for the assessment of the BOM removal capacity of drinking water biofilters, operated under different conditions. This is important because of the relative complexity of the measurements of BOM surrogates, e.g. assimilable organic carbon and biodegradable dissolved organic carbon, and BOM components. 相似文献
4.
5.
Characterisation of the behaviour of particles in biofilters for pre-treatment of drinking water 总被引:1,自引:0,他引:1
Persson F Långmark J Heinicke G Hedberg T Tobiason J Stenström TA Hermansson M 《Water research》2005,39(16):3791-3800
Biofiltration of surface water was examined using granular activated carbon (GAC) and expanded clay (EC). Particle removal was 60-90%, measured by flow cytometry, which enabled discrimination between total- and autofluorescent particles (microalgae) in size ranges of 0.4-1 and 1-15 microm, and measured by on-line particle counting. Total particles were removed at a higher degree than autofluorescent particles. The biofilters were also challenged with 1 microm fluorescent microspheres with hydrophobic and hydrophilic surface characteristics and bacteriophages (Salmonella typhimurium 28B). Added microspheres were removed at 97-99% (hydrophobic) and 85-89% (hydrophilic) after 5 hydraulic residence times (HRT) and microspheres retained in the biofilter media were slowly detaching into the filtrate for a long time after the addition. Removal of bacteriophages (5 HRT) was considerably lower at 40-59%, and no long-lasting detachment was observed. A comparison of experimental data with theoretical predictions for removal of particles in clean granular media filters revealed a similar or higher removal of particles around 1 microm in size than predicted, while bacteriophages were removed at a similar or lesser extent than predicted. The results highlight the selectivity and dynamic behaviour of the particle removal processes and have implications for operation and microbial risk assessment of a treatment train with biofilters as pre-treatment. 相似文献
6.
Chlorination of model drinking water biofilm: implications for growth and organic carbon removal 总被引:1,自引:0,他引:1
The influence of chlorine on biofilm in low organic carbon environments typical of drinking water or industrial process water was examined by comparing biomass and kinetic parameters for biofilm growth in a chlorinated reactor to those in a non-chlorinated control. Mixed-population heterotrophic biofilms were developed in rotating annular reactors under low concentration, carbon-limited conditions (< 2 mg/L as carbon) using three substrate groups (amino acids, carbohydrates and humic substances). Reactors were operated in parallel under identical conditions with the exception that chlorine was added to one reactor at a dose sufficient to maintain a free chlorine residual of 0.09-0.15 mg/L in the effluent. The presence of free chlorine resulted in development of less biofilm biomass compared to the control for all substrates investigated. However, specific growth and organic carbon removal rates were on the average five times greater for chlorinated biofilm compared to the control. Observed yield values were less for chlorinated biofilm. Although chlorinated biofilm's specific organic carbon removal rate was high, the low observed yield indicated organic carbon was being utilized for purposes other than creating new cell biomass. The impacts of free chlorine on mixed-population biofilms in low-nutrient environments were different depending upon the available substrate. Biofilms grown using amino acids exhibited the least difference between control and chlorinated kinetic parameters; biofilm grown using carbohydrates had the greatest differences. These findings are particularly relevant to the fundamental kinetic parameters used in models of biofilm growth in piping systems that distribute chlorinated, low-carbon-concentration water. 相似文献
7.
Organic arsenic removal from drinking water 总被引:2,自引:0,他引:2
Arsenic occurs in both inorganic and organic forms in water. Although various methods have been adopted to remove inorganic species of arsenic from drinking water, not much emphasis has been given to the removal of organic species of arsenic. In the present study column studies were conducted using manganese greensand (MGS), iron oxide-coated sand (IOCS-1 and IOCS-2) and ion exchange resin in Fe3+ form, to examine the removal of organic arsenic (dimethylarsinate) spiked to required concentrations in tap water. Batch studies were conducted with IOCS-2, and the results showed that the organic arsenic adsorption capacity was 8 μg/g IOCS-2. Higher bed volumes (585 BV) and high arsenic removal capacity (5.7 μg/cm3) were achieved by the ion exchange resin among all the media studied. Poor performance was observed with MGS and IOCS-1. 相似文献
8.
Biological filters combining microbial activity and rapid sand filtration are used in drinking water treatment plants for enhanced biodegradable organic matters (BOM) removal. Biofilms formed on filter media comprised of bacteria enclosed in a polymeric matrix are responsible for the adsorption of BOM and attachment of planktonic microorganisms. This study investigated the removal of Escherichia coli cells injected into laboratory-scale biofilters and the role of biofilm in retaining the injected E. coli. Green fluorescent protein was used as a specific marker to detect and quantify E. coli in the biofilms. About 35% of the total injected E. coli cells were observed in the filter effluents, when initial cell concentrations were measured at 7.4 x 10(6) CFU/mL and 1.6 x 10(7) CFU/mL in two separate experiments. The results from real-time PCR and plate count analysis indicated that 95% of the E. coli retained inside the filters were either non-viable or could not be recovered by colony counting techniques. Injected cells were unevenly distributed inside the filter with more than 70% located at the top 1/5 of the filter. Images obtained from an epifluorescent microscope showed that E. coli cells were embedded inside the biofilm matrix and presented mainly as microcolonies intertwined with other microorganisms, which was consistent with findings from standard plate count methods and qPCR. 相似文献
9.
《Water research》1996,30(9):1973-1978
10.
A procedure for the selective removal of uranium traces dissolved in drinking water has been studied. Plate module membrane filtration equipment was operated to evaluate the performance and selectivity of three different nanofiltration flat-sheet membranes. Experiments were carried out using various commercial mineral waters with distinct physicochemical compositions. The membranes were first discriminating by their ability to reject uranium in the presence of the main cations found in mineral waters, using a 2 mg L(-1) (2000 ppb) concentration of uranium. The rejection of U(VI) was dependent on the uranyl speciation and the ionic strength. Second, removal of uranium traces (0.02 mg L(-1), 20 ppb) was performed using the nanofiltration membrane showing the highest selectivity for uranium toward alkaline and alkaline-earth ions. The results showed a high performance of the nanofiltration membrane, Osmonics DL, for selective uranium rejection at low pressure (1 bar), illustrating the advantage of nanofiltration for the selective removal of uranium from drinking water. 相似文献
11.
Treated drinking water samples from 12 water utilities in the Midwestern United States were collected during Fall 2003 and Spring 2004 and were analyzed for selected neutral degradates of chloroacetamide herbicides, along with related compounds. Target analytes included 20 neutral chloroacetamide degradates, six ionic chloroacetamide degradates, four parent chloroacetamide herbicides, three triazine herbicides, and two neutral triazine degradates. In the fall samples, 17 of 20 neutral chloroacetamide degradates were detected in the finished drinking water, while 19 of 20 neutral chloroacetamide degradates were detected in the spring. Median concentrations for the neutral chloroacetamide degradates were ∼2-60 ng/L during both sampling periods. Concentrations measured in the fall samples of treated water were nearly the same as those measured in source waters, despite the variety of treatment trains employed. Significant removals (average of 40% for all compounds) were only found in the spring samples at those utilities that employed activated carbon. 相似文献
12.
Transparent exopolymer particle removal in different drinking water production centers 总被引:1,自引:0,他引:1
Van Nevel S Hennebel T De Beuf K Du Laing G Verstraete W Boon N 《Water research》2012,46(11):3603-3611
Transparent exopolymer particles (TEP) have recently gained interest in relation to membrane fouling. These sticky, gel-like particles consist of acidic polysaccharides excreted by bacteria and algae. The concentrations, expressed as xanthan gum equivalents L−1 (μg Xeq L−1), usually reach hundred up to thousands μg Xeq L−1 in natural waters. However, very few research was performed on the occurrence and fate of TEP in drinking water, this far. This study examined three different drinking water production centers, taking in effluent of a sewage treatment plant (STP), surface water and groundwater, respectively. Each treatment step was evaluated on TEP removal and on 13 other chemical and biological parameters. An assessment on TEP removal efficiency of a diverse range of water treatment methods and on correlations between TEP and other parameters was performed. Significant correlations between particulate TEP (>0.4 μm) and viable cell concentrations were found, as well as between colloidal TEP (0.05-0.4 μm) and total COD, TOC, total cell or viable cell concentrations. TEP concentrations were very dependent on the raw water source; no TEP was detected in groundwater but the STP effluent contained 1572 μg Xeq L−1 and the surface water 699 μg Xeq L−1. Over 94% of total TEP in both plants was colloidal TEP, a fraction neglected in nearly every other TEP study. The combination of coagulation and sand filtration was effective to decrease the TEP levels by 67%, while the combination of ultrafiltration and reverse osmosis provided a total TEP removal. Finally, in none of the installations TEP reached the final drinking water distribution system at significant concentrations. Overall, this study described the presence and removal of TEP in drinking water systems. 相似文献
13.
Effects of water chemistry on arsenic removal from drinking water by electrocoagulation 总被引:1,自引:0,他引:1
Wei WanTroy J. Pepping Tuhin BanerjiSanjeev Chaudhari Daniel E. Giammar 《Water research》2011,45(1):384-392
Exposure to arsenic through drinking water poses a threat to human health. Electrocoagulation is a water treatment technology that involves electrolytic oxidation of anode materials and in-situ generation of coagulant. The electrochemical generation of coagulant is an alternative to using chemical coagulants, and the process can also oxidize As(III) to As(V). Batch electrocoagulation experiments were performed in the laboratory using iron electrodes. The experiments quantified the effects of pH, initial arsenic concentration and oxidation state, and concentrations of dissolved phosphate, silica and sulfate on the rate and extent of arsenic removal. The iron generated during electrocoagulation precipitated as lepidocrocite (γ-FeOOH), except when dissolved silica was present, and arsenic was removed by adsorption to the lepidocrocite. Arsenic removal was slower at higher pH. When solutions initially contained As(III), a portion of the As(III) was oxidized to As(V) during electrocoagulation. As(V) removal was faster than As(III) removal. The presence of 1 and 4 mg/L phosphate inhibited arsenic removal, while the presence of 5 and 20 mg/L silica or 10 and 50 mg/L sulfate had no significant effect on arsenic removal. For most conditions examined in this study, over 99.9% arsenic removal efficiency was achieved. Electrocoagulation was also highly effective at removing arsenic from drinking water in field trials conducted in a village in Eastern India. By using operation times long enough to produce sufficient iron oxide for removal of both phosphate and arsenate, the performance of the systems in field trials was not inhibited by high phosphate concentrations. 相似文献
14.
15.
Ljiljana Zlatanovic Andreas Moerman Jan Peter van der Hoek Jan Vreeburg Mirjam Blokker 《Urban Water Journal》2017,14(10):1031-1037
Domestic drinking water supply systems (DDWSs) are the final step in the delivery of drinking water to consumers. Temperature is one of the rate-controlling parameters for many chemical and microbiological processes and is, therefore, considered as a surrogate parameter for water quality processes. In this study, a mathematical model is presented that predicts temperature dynamics of the drinking water in DDWSs. A full-scale DDWS resembling a conventional system was built and run according to one year of stochastic demands with a time step of 10 s. The drinking water temperature was measured at each point-of-use in the systems and the data-set was used for model validation. The temperature model adequately reproduced the temperature profiles, both in cold and hot water lines, in the full-scale DDWS. The model showed that inlet water temperature and ambient temperature have a large effect on the water temperature in the DDWSs. 相似文献
16.
Molly J. Rihn Xueqing Zhu Makram T. Suidan Byung J. Kim Byung R. Kim 《Water research》1997,31(12):2997-3008
In response to the growing concern over volatile organic compounds (VOCs), biofiltration is becoming an established economical air pollution control technology for removing VOCs from waste air streams. Current research efforts are concentrating on improving control over key parameters that affect the performance of gas phase biofilters. This study utilized diethyl ether as a substrate, nitrate as the sole nutrient nitrogen source within two co-currently operated trickle-bed biofilters, for over 200 days. The two pelletized medium biofilters were operated at a low empty bed contact time of 25 s, inlet gas flow rates of 8.64 m3/day, nutrient liquid flow rates of 1 liter/day, and COD loading rates of 1.8 and 3.6 kg/m3 per day, respectively. Operational parameters including contaminant concentration in the gas phase, nutrient nitrate concentration in the aqueous phase, and the frequency of biomass removal were considered. Special attention was given to the effect and the role of nitrate on VOC removal. Throughout the experiment, nitrate persisted in the liquid effluent and the ether removal efficiencies improved with increasing influent nitrate concentration, which suggest that the nitrate diffusion into the biofilms is rate determining. By increasing the concentration of oxygen in the feed to this biofilter from 21% (ambient air) to 50 and 100%, while maintaining an influent ether concentration of 133 ppmv and a feed nitrate concentration of 67 mg-N/liter, the performance of the biofilter was not significantly affected. These results suggest that nitrogen was rate limiting as a growth nutrient rather than as an electron acceptor for the respiration of ether. The results also indicated that removal of excess biomass is necessary to maintain long-term performance. However, the required frequency of biomass removal depends on operating parameters such as loading. 相似文献
17.
The influence of different treatment processes on the mutagenic activity (Ames test) and some chemical parameters in water were investigated in a few waterworks. Application of a chlorine treatment generally increased the direct and promutagenic activity, but the extent increase proved to be dependent on the type of water chlorinated. The use of ozone in the preparation of drinking water decreased the mutagenic activity in the water. The extent reduction was also dependent on the type of water ozonated. Dune filtration greatly reduced the mutagenic activity. Slow sand filtration could not be evaluated, because of the toxicity of the organic concentrates for the bacterial strains. Granular activated carbon filters, in operation for about 1 year, reduced the mutagenic activity below the detection level. A similar filter which has operated for more than 1.5 years in a pilot plant, showed a breakthrough of mutagenic activity, suggesting that carbon filters are able to remove organic mutagens for a limited period. The results of the chemical parameters measured before and after the different treatment processes showed that none of these parameters were a reliable indicator for the mutagenic activity. 相似文献
18.
Application of carbon nanotube technology for removal of contaminants in drinking water: A review 总被引:1,自引:0,他引:1
Venkata K.K. Upadhyayula Shuguang Deng Martha C. Mitchell Geoffrey B. Smith 《The Science of the total environment》2009,408(1):1-13
Carbon nanotube (CNT) adsorption technology has the potential to support point of use (POU) based treatment approach for removal of bacterial pathogens, natural organic matter (NOM), and cyanobacterial toxins from water systems. Unlike many microporous adsorbents, CNTs possess fibrous shape with high aspect ratio, large accessible external surface area, and well developed mesopores, all contribute to the superior removal capacities of these macromolecular biomolecules and microorganisms. This article provides a comprehensive review on application of CNTs as adsorbent media to concentrate and remove pathogens, NOM, and cyanobacterial (microcystin derivatives) toxins from water systems. The paper also surveys on consideration of CNT based adsorption filters for removal of these contaminants from cost, operational and safety standpoint. Based on the studied literature it appears that POU based CNT technology looks promising, that can possibly avoid difficulties of treating biological contaminants in conventional water treatment plants, and thereby remove the burden of maintaining the biostability of treated water in the distribution systems. 相似文献
19.
用氧化铝改性沸石制备了一种除氟材料,其最佳制备工艺参数为:在200℃下焙烧1.5 h对沸石进行预处理的基础上,用pH=9的Al(OH)3悬浮液对沸石进行覆盖沉淀改性,并在400 ℃下焙烧1 h涂层,最后用质量分数为4%的Al2(SO4)3溶液浸渍12 h.改性后的沸石对氟离子的吸附量可达0.84 mg/g.改性前后除氟性能的对比试验结果表明,活性氧化铝成分与氟离子的络合作用对氟的去除起主要作用. 相似文献
20.
The use of ozone as a pre-oxidant or intermediate oxidant in drinking-water treatment is becoming increasingly common. The ozonation of natural source waters containing natural organic matter produces biodegradable by-products such as organic acids, aldehydes, and ketoacids. These organic by-products serve as carbon source for bacteria, potentially causing regrowth problems in distribution systems. The measurement of biodegradable dissolved organic carbon (BDOC) provides quantitative insight into the amount of BDOC that is present. In drinking-water treatment, removal of BDOC can also reduce the formation potential of chlorination disinfection by-products such as trihalomethanes and haloacetic acids. Removal of BDOC was optimal at an applied ozone:DOC ratio of 2:1 (mg/mg) for source waters containing DOC levels ranging from 3 to 6 mg/liter. The use of biotreatment resulted in a 40–50% decrease in DOC, a 90–100% reduction in aldehydes, and a 40–60% reduction in trihalomethane formation potential. No removal of bromate ion and dibromoacetic acid was observed. A positive correlation was obtained between BDOC and assimilable organic carbon; both parameters indicate a tendency to plateau at an applied ozone/DOC weight ratio of 2:1. 相似文献