首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Selectivity of solid-phase extraction (SPE) was combined with the concentration power of dispersive liquid–liquid microextraction (DLLME) to obtain a sensitive, low solvent consumption method for high-performance liquid chromatography determination of diazinon and chlorpyrifos in rice. In this method, rice samples were extracted by ultrasound-assisted extraction followed by SPE. Then, the SPE eluent was used as a disperser solvent in the next dispersive liquid-liquid microextraction step for further purification and enrichment of diazinon and chlorpyrifos. Under the optimal conditions, the linear range was from 5.0 to 250 μg kg?1 for diazinon and from 2.5 to 250 μg kg?1 for chlorpyrifos. Limits of detection of diazinon and chlorpyrifos were 1.5 and 0.7 μg kg?1, respectively. Limits of quantitation of diazinon and chlorpyrifos were 5.5 and 3.0 μg kg?1, respectively. The precisions and recoveries also were investigated by spiking 10 μg kg?1 concentration in rice. The recoveries obtained were over 90 % with relative standard deviation (RSD%) below 9.0 %. The new approach was utilized to successfully detect trace amounts of diazinon and chlorpyrifos in different Iranian rice samples.  相似文献   

2.
In the present study, a new method based on microwave-assisted extraction and dispersive liquid–liquid microextraction (MAE–DLLME) followed by high-performance liquid chromatography (HPLC) was proposed for the separation and determination of oleuropein (Ole) and hydroxytyrosol (HyT) from olive pomace samples. The effective factors in the MAE–DLLME process such as microwave power, extraction time, the type and volume of extraction, and dispersive solvents were studied and optimized with the aid of response surface methodology (RSM) based on a central composite design (CCD) to obtain the best condition for Ole and HyT extraction. At the optimized conditions, parameter values were 220 W microwave power, 12 min extraction time, 60 μL extracting solvent, and 500 μL dispersive solvent. The calibration graphs of the proposed method were linear in the range of 10–500,000 μg L?1, with the coefficient of determination (R2) higher than 0.99 for Ole and HyT. Repeatability of the method, described as the relative standard deviation (RSD), was 4.12–5.63% (n?=?6). The limits of detection were 35 and 20 μg L?1 for Ole and HyT, respectively. The recoveries of these compounds in the spiked olive pomace sample were from 93 to 98%. The proposed method, MAE–DLLME–HPLC–UV, was an accurate, rapid, and reliable method when compared with previous methods.  相似文献   

3.
In this study, dispersive solid phase extraction (DSPE) combined with dispersive liquid–liquid microextraction (DLLME) method was developed for the determination of triazole fungicide residues in tea samples. DSPE with ODS C18, primary secondary amine, and florisil as sorbents was applied to clean up and minimize matrix interference from tea samples; it was followed with the enrichment of target compounds in the DLLME procedure and detection with liquid chromatography–tandem mass spectrometry (LC-MS/MS). The effects of various experimental parameters on the DSPE and DLLME procedures were studied systematically, such as the kinds and volume of sorbents, extraction and dispersive solvents, and extraction time. Under optimum conditions, the method was validated in a tea matrix. The matrix-matched calibration curves of three triazoles had good linearity in the range of 0.0125–50 μg kg?1, and the linear regression coefficients (r) ranged from 0.9998 to 0.9999. The limits of quantification (S/N?=?10) for penconazole, tebuconazole, and triadimenfon were 4.0, 7.8, and 31.6 ng kg?1, respectively. The intra-day and inter-day relative standard deviations varied from 3.6 to 18.6 %. Recoveries in three concentration levels were between 91 and 118 %. The obtained results show that the proposed DSPE-DLLME-LC-MS method has the potential to analyze trace fungicides in a complex sample matrix.  相似文献   

4.
In this study, a two-step extraction technique was developed for extraction and preconcentration of parabens from beverage samples using ionic liquid dispersive liquid–liquid microextraction (IL-DLLME) and magnetic solid-phase extraction (MSPE). In this IL-DLLME followed by MSPE method, ionic liquid (IL, 1-octyl-3-methylimidazolium hexafluorophosphate) formed hydrophobic microdroplets in beverage samples as an extractant of parabens; after the IL-DLLME process was completed, graphene modified Fe3O4 nanoparticles (Fe3O4@G) were placed to adsorb and isolate IL from the sample solution. After the supernatant was carefully moved, acetonitrile was added to elute the IL containing parabens from Fe3O4@G. The experimental variables affecting the extraction procedure have been systematically studied. Under optimal conditions, the detection limits were less than 1.53 ng/mL and the linear detection ranges were 2–500 ng/mL (R 2 ≥ 0.998) for these analytes. The recoveries for spiked samples were 58.8–89.2% and satisfactory precision (RSD ≤ 4.8%) were obtained.  相似文献   

5.
There has been a controversy regarding the use of exogenous oxytocin (OT) in milking cattle which may have toxicological consequences during nonphysiological exposure. In the present study, a new sensitive extraction method for OT was developed followed by enzyme immune assay (EIA) or high-performance liquid chromatography (HPLC) analysis. The extraction of OT in milk involves two steps: (1) TCA precipitation of milk proteins and (2) solid-phase extraction (SPE) cleanup process. Without these steps, analysis of OT in milk was not possible. Utilizing EIA as a quantitative tool the limit of detection (LOD) and limit of quantitation (LOQ) were found to be 7.74 and 10.3 pg?ml?1, precision in terms of intra- and interday coefficient of variation was below 13 % (%RSD, N?=?8), while percent recoveries were between 85 and 92 %. Utilizing UV-HPLC, the LOD, LOQ, precision, and recovery values were found to be 4.1 ng?ml?1, 9.8 ng?ml?1, 2–10 %, and 84–91 %, respectively. OT was found to be stable against adverse temperature (up to 100 °C) and pH (2 to 10) and simulated gastric fluid digestibility assay. Four milk samples collected from the market were analyzed, which showed that TCA precipitation and SPE steps are mandatory and the results were validated by LC-MS showing mass ion peak at 1 kD.  相似文献   

6.
Being susceptible to any matrix with pH >5, taking cabbage as an example, the low recovery of chlorothalonil residues adsorbed onto the cabbage matrix was almost completely improved by extracting with 1/1 (v/v) acetonitrile (containing 5 % acetic acid)/toluene. Under the optimized conditions, the recoveries of chlorothalonil in cabbage fortified at three concentrations of 0.5 to 10 mg kg?1 were 71–93 % with relative standard deviations (RSDs) lower than 6 %. The limit of detection (LOD) and the limit of quantification (LOQ) of the gas chromatography–mass spectrometry (GC–MS) method for chlorothalonil were 0.05 and 0.5 mg kg?1, respectively, which were much lower than the maximum residue limits (MRLs). The proposed analytical method demonstrated a potential for its application to monitor for chlorothalonil and to help assure food safety, especially base-sensitive-pesticide analysis.  相似文献   

7.
A dispersive liquid–liquid microextraction (DLLME) method coupled to high-performance liquid chromatography was developed for the analysis of α-tocopherol in grain samples. The DLLME parameters including the type and volume of extractants, the volume of disperser and the addition of salt were examined. The optimized DLLME procedure consisted in the formation of a cloudy solution promoted by the fast addition to the sample (5 mL of saponified sample solution diluted with 5 mL of water) of a mixture of carbon tetrachloride (extraction solvent, 80 μL) and ethanol (dispersive solvent, 200 μL) without the addition of salt, followed by shaking for 5 min and centrifuging for 3 min at 5,000 rpm. Intra- and inter-day repeatability expressed as % RSD were 3.5 and 7.6 %, respectively. The limit of detection and the limit of quantification were 1.9 and 6.3 μg?L?1. The comparison of this method with the national standardized extraction method, supercritical carbon dioxide extraction, accelerated solvent extraction, and conventional heat-reflux extraction indicates that the DLLME was accurate (no significant differences at the 0.05 % probability level), high efficient, low organic solvent-consuming, and low cost. This procedure was successfully applied to 42 samples of 14 types of purple wheat, for which the content of α-tocopherol exhibited a significantly negative correlation with the pigment content measured by a spectrophotometer. The recovery rates ranged from 90.5 to 103.7 %.  相似文献   

8.
A validated method based on solid-phase extraction and ultra high-performance liquid chromatography–triple quadrupole tandem mass spectrometry, with electrospray ionization operated in the positive ion mode and multiple reaction monitoring, was developed for the determination of nicotine in Solanaceae vegetables. Sample preparation involved liquid–solid extraction, centrifugation, filtration, and solid-phase extraction. Two kinds of solid-phase extraction adsorbents, based on different retention mechanisms, were investigated. Relatively higher recoveries were obtained with a hydrophilic–lipophilic-balanced cartridge. A deuterated internal standard was used for quantification. The limit of quantification (LOQ) of nicotine in different vegetables was found to be between 0.07 and 0.5 μg/kg. The nicotine levels in the vegetable samples were above the LOQs. The method described here is thus suitable for the analysis of large sample batches, because it provides accurate quantification, high sensitivity and rapid chromatographic separation with facile preparation. The solid-phase extraction cartridges and organic solvents used in this work are easy to obtain, enabling the application of this method in most analytical laboratories.  相似文献   

9.
In this paper, based on the mechanism of the quick, easy, cheap, effective, rugged and safe (QuEChERS) method, a novel graphene grafted silica-coated Fe3O4 (Fe3O4@SiO2@G) was synthesized and applied as the efficient magnetic solid-phase extraction (MSPE) adsorbent for rapid cleanup of vegetable samples prior to analyzing 16 preservative residues by gas chromatography–mass spectrometry (GC-MS). The method, which took advantages of the novel nanoparticle adsorbent and an external magnetic field separation targets from samples, not only could avoid the time consuming of the traditional solid-phase extraction, but also could be developed for simultaneous determination of 16 preservative residues in vegetables. Various experimental parameters that could affect the extraction efficiencies have been investigated. Under the optimum conditions, 16 preservatives showed good linearity over the range of 0.02–2.00 mg/L and correlation coefficients (R 2) of 0.9946–0.9998. The limits of detections (LODs) were in the range of 0.21–11.50 μg/kg. The recoveries of 16 preservatives ranged from 78.3 to 116.7 %, and the relative standard deviations (RSDs) ranged from 1.4 to 11.9 %.  相似文献   

10.
A vortex-assisted liquid–liquid microextraction (VALLME) method using hexanoic acid as extractant followed by high-performance liquid chromatography–diode array detection was developed for the extraction and determination of five phthalate esters (PAEs) including bis-methylglycol ester (DMEP), benzyl butyl phthalate (BBP), dicyclohexyl phthalate (DCHP), di-n-butyl phthalate (DBP), and di-n-octyl phthalate (DNOP) from liquor samples. In this method, hexanoic acid was employed as extraction solvent, because its density is lower than water. And vortex mixing was utilized as a mild emulsification procedure to reduce emulsification time and improve the effect of extraction. Under the studied conditions, five phthalate esters were successfully separated within 20 min and the limits of detection were 2.3 ng mL?1 for DMEP, 1.1 ng mL?1 for BBP, 1.9 ng mL?1 for DCHP, 1.2 ng mL?1 for DBP, and 1.5 ng mL?1 for DNOP, respectively. Recoveries of the PAEs spiked into liquor samples were ranged from 89 to 93 %. The precisions of the proposed method were varied from 1.6 to 2.6 % (RSD). The VALLME method has been proved to have the potential to be applied to the preconcentration of the target analytes. Moreover, the method is simple, high sensitivity, consumes much less solvent than traditional methods and environmental friendly.  相似文献   

11.
A fast and simple extraction and preconcentration method for some triazole pesticides has been developed using a homogeneous liquid–liquid extraction method performed in a narrow-bore tube. The extraction is based on phase separation of a water-miscible organic solvent from aqueous solution in the presence of a salting out agent. In this work, the homogeneous solution of water and acetonitrile (water-soluble extraction solvent) was broken by addition of 30 %, w/v, sodium chloride (salting out agent). After sonication, a small volume of acetonitrile was collected on top of the tube and the extracted analytes in the collected phase were determined by gas chromatography–flame ionization detection. The effect of various experimental parameters including kind and volume of the water-soluble organic solvent, amount of salt, length and diameter of tube, and pH of sample solution was investigated. Under the optimum conditions, calibration graphs were linear over the range of 3–5,000 μg L?1. Relative standard deviations were less than 5.4 % for six repeated determinations (C?=?100 μg L?1). Furthermore, the limits of detection (S/N?=?3) and quantification (S/N?=?10) were obtained in the ranges of 0.60–4.8 and 1.9–16 μg L?1, respectively. This method is very simple and rapid, requiring less than 10 min for sample preparation. It has been successfully utilized for the analysis of triazole pesticides in the grape juice samples.  相似文献   

12.
A rapid and effective analytical method for determination of pydiflumetofen residues in some foods of plant and animal origin (grapes, tomatoes, wheat, pork, milk, and eggs) was developed using a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation procedure followed by ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC–MS/MS). Acetonitrile was served as the extraction solvent, and an octadecylsilane-dispersive solid-phase extraction (C18-dSPE) was used to cleanup the analyte, and then detected by UPLC–MS/MS. Pydiflumetofen was eluted within 3.0 min from the HSS T3 chromatography column connected to an electrospray ionization source in positive mode. The linearity of the method was excellent (R2?≥?0.992) in the pydiflumetofen concentration range of 10–1000 μg kg?1. The recoveries of spiked pydiflumetofen (10, 100, and 1000 μg kg?1) from the matrices were satisfactory, being between 72.0 and 110.3%, and all with relative standard deviation values of <?15.1%. The limit of quantification for pydiflumetofen was 10 μg kg?1. This study provides a method for the routine monitoring of pydiflumetofen.  相似文献   

13.
A method for simultaneous analysis of six fungicides in grape was developed by using ultrasound-assisted dispersive liquid–liquid microextraction based on solidification of floating organic droplet method (UA-DLLME-SFO) combined with high-performance liquid chromatography equipped with UV detector (HPLC-UV). The extractant was obtained from grape samples using the modified QuEChERS (acronym of quick, easy, cheap, effective, rugged, and safe) method. Then the target fungicides were rapidly transferred from the acetonitrile extract to the phase of 100 μL of 1-undecanol, which is of low density, low toxicity, and proper melting point near room temperature using UA-DLLME-SFO. Experimental parameters affecting the extraction efficiency were studied and optimized. Under the optimum conditions, recovery tests were carried out at three different concentrations. The average recoveries ranged from 72.5 % to 100.6 % with relative standard deviations of 0.8 % to 7.3 % (n?=?5). The limits of quantifications of the method for all the target fungicides varied from 0.5 to 5 mg?kg?1, which were lower than the MRLs established by Codex Alimentarius Commission and USA. Compared with the conventional method, the proposed method is easy, fast, economic, and less toxic and avoids conventional concentration methods like rotary evaporation and nitrogen stream drying.  相似文献   

14.
A graphene-based magnetic nanocomposites (G-Fe3O4 MNPs) was synthesized and used as the adsorbent for the extraction of some triazole fungicides (triadimefon, paclobutrazol, hexaconazole, myclobutanil, diniconazole, propiconazole, and tebuconazole) in cucumber, cabbage, and tomato samples prior to gas chromatography–mass spectrometry detection. Various experimental parameters affecting the extraction efficiencies, such as the amount of G-Fe3O4 MNPs, extraction time, pH and salt concentration of the sample solution, and desorption conditions were investigated. Under the optimized experimental conditions, the enrichment factors of the method for the analytes were in the range from 461 to 697. The signal response was linear in the range of 0.5–35.0 ng g?1 for all the analytes with the correlation coefficients ranging from 0.9810 to 0.9986. The limits of detection (S/N?=?3) of the method for the analytes were between 0.01 and 0.10 ng g?1. The recoveries of the method for the seven triazoles were in the range from 84.4 to 108.2 % with RSDs between 3.4 and 10.6 %.  相似文献   

15.
In this study, a green, simple, and sensitive method was developed for the analysis of aliphatic aldehydes from fried meat by using a modified gas purge–microsyringe extraction (GP–MSE) system in combination with high-performance liquid chromatography (HPLC) with fluorescence detection. The modified GP–MSE system possessed two gas channels and showed better recoveries for compounds with diverse density in comparison with one gas channel GP–MSE system. Target compounds in fried meat were effectively extracted without the traditional solvent extraction and lipid removing process, while the HPLC sensitivity of aldehydes was enhanced by introducing 2-(12-benzo[b]acridin-5(12H)-yl)-acetohydrazide (BAAH) with excellent fluorescence property into the molecules. Parameters influencing the extraction efficiency and HPLC sensitivity were optimized. The limits of detection (LODs) ranged from 0.30 to 0.45 μg/kg, and the limits of quantification (LOQs) ranged from 1.0 to 1.5 μg/kg. The recoveries of the target compounds were in the range of 86.9 to 95.6%. The proposed method was successfully applied to the analysis of aldehydes in fried meat samples. Formaldehyde, acetaldehyde, pentanal, hexanal, heptanal, octanal, nonaldehyde, and decanal were all found in fried meat samples with concentrations ranging from 0.05 to 17.8 mg/kg.  相似文献   

16.
A highly selective sample cleanup procedure combining ionic liquid-based surfactant extraction (ILSE) and magnetic dispersive μ-solid phase extraction (MD-μ-SPE) was triumphantly developed for the synchronously extraction of four phthalate acid esters (PAEs) in packaging milk samples prior to high-performance liquid chromatography coupled with photodiode array detector (HPLC-DAD). In this ionic liquid (IL)-based surfactant method, 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM] [PF6]) was used as extraction solvent, anionic surfactant sodium linear alkylbenzene sulfonate (LAS) was used as auxiliary extraction solvent, and then sodium chloride (NaCl) was mixed to drive phase separation. The synthesized hydrophobic diatomaceous earth-supported Fe3O4 magnetic nanoparticles (DSMNPs) were applied as an efficient adsorbent to retrieve the analyte-containing IL and LAS. Under the optimal extraction situations, good linearity of the approach was obtained in the concentration range from 10 to 1000 ng/mL for target analytes, and the preconcentration process was rapidly accomplished in 5 min. The limits of detection (LODs) based on a signal-to-noise ratio (S/N = 3) were ranged from 1.42 to 3.57 ng/mL with the relative standard deviations (RSDs) over the range of 1.84–3.56% (n = 5). The above-mentioned method was applied to the trace analysis of four PAEs including benzyl butyl phthalate (BBP), dicyclohexyl phthalate (DCHP), di-n-butyl phthalate (DBP), and di-n-octyl phthalate (DNOP) in packaging milk samples, and recoveries were between 89.8 and 99.7%.  相似文献   

17.
A simple and rapid dispersive liquid?Cliquid microextraction (DLLME) method was applied to preconcentrate sulfite ions from aqueous samples as a prior step to its determination by fiber optic-linear array detection spectrophotometry. The procedure is based on the color reaction of sulfite with o-phthaldialdehyde (OPA) in the presence of ammonia to form isoindole and extraction of the formed isoindole derivative using the DLLME technique. The conditions for the microextraction performance were investigated and optimized. The calibration graph was linear in the range of 2?C100???g?L?1with a detection limit of 0.2???g?L?1. The relative standard deviation for five replicate measurements of 10 and 50???g?L?1of sulfite were 2.8 and 2.0?%, respectively. Under the optimized conditions, the enrichment factor of ~133 was obtained from a sample volume of 10?mL. The proposed method was successfully applied to the sulfite determination in drinking water and in food samples.  相似文献   

18.
A simple and rapid method based on magnetic solid-phase extraction (MSPE) combined with high-performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC–MS/MS) was used for the determination of 15 sulfonamides from milk samples. The extraction and cleanup used a graphene oxide-based magnetic nanocomposite (Fe3O4@GO) as an adsorbent. Various experimental parameters that could affect the extraction efficiencies, such as the amount of Fe3O4@GO, the extraction time, the ionic strength of sample solution, and the type of eluent, were investigated. Under optimized experimental conditions, good linearity was observed in the range of 2.0 to 100.0 μg L?1 for all of the analytes, with correlation coefficients (R2) ranging from 0.994 to 0.999. The limits of detection for the method ranged between 0.02 and 0.13 μg L?1. Mean values of the relative standard deviation of intraday and interday precision ranging from 1.0 to 7.3 % and from 1.7 to 8.1 % were obtained, respectively. The average recoveries were between 73.4 and 97.4 % at three different spiked levels. It was confirmed that the Fe3O4@GO nanocomposite was an effective MSPE material for use in sulfonamide analyses in milk samples.  相似文献   

19.
A method was developed for the analysis of four polycyclic aromatic hydrocarbons regulated in the European Union, namely, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene in edible oils. Multi-walled carbon nanotubes were applied for dispersive solid-phase extraction of analytes from the oils after dilution with n-hexane followed by elution of analytes with toluene under reflux conditions. Gas chromatography coupled to tandem mass spectrometry was used for quantitative determination of the analytes. The efficiency of four nanotube-based sorbents was evaluated. The performance characteristics of the method permitted reliable measurement of four regulated polycyclic aromatic hydrocarbons in oil samples according to the criteria stated in the Commission Regulation No. 836/2011 and considering the maximum levels (MLs) stated in the Commission Regulation (EU) No. 835/2011. The concentrations of the selected analytes in real-world samples determined by our developed method and by previously validated gel permeation chromatography method were found to be in a good agreement.  相似文献   

20.
Olives, the fruit of the Olea europaea tree, are highly appreciated in olive oil and table olives (20 % of crops) not only for their flavor but also for their nutritional properties, especially for antioxidant compounds such as squalling (SQ), α-tocopherol (TH) and β-carotene (BC). This paper presents a new analytical method for simultaneously determining SQ, TH and BC in table olives by using solid phase extraction (SPE) and high performance-liquid chromatography with diode array detection (HPLC-DAD), avoiding the classic saponification process. The correlation coefficients of calibration curves of the analyzed compounds ranged from 0.998 to 0.999, and the recoveries were in the range of 89.4–99.6 %. The validated method was used to analyze 30 table olive samples from Italy for their content of SQ (537–1,583 mg kg?1), TH (21–90 mg kg?1) and BC (0.4–2.6 mg kg?1). Finally, experiments with HPLC-MS were conducted to compare this novel method with the classic saponification procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号